首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A male in his 70s was found lying dead in the living room of his house. A gunshot entrance wound was observed in the left orbit, with a lead slug and wadding left in the skull, which exhibited fatal cranio‐cerebral trauma. A cartridge had been discharged from a handmade launcher, or zip gun, that had been fixed to a spare gun barrel on a pipe chair, by heating the launcher from the side using a gas burner. The deceased had owned guns for hunting in the past and had returned the license, but he had retained a spare barrel and live cartridges at home. In this unique case of suicide, a zip gun was discharged by heating with a gas burner.  相似文献   

2.
The location of the gun following suicidal gunshot wound was studied by reviewing 574 such deaths in which the scene was investigated by a medical examiner investigator and the body was examined at the Bexar County Medical Examiner's Office in San Antonio, Texas. The position of the gun could not be established in 76 cases. In the remaining 498 cases, the gun remained in the deceased's hand in 24% of the cases. In 69% of the cases, the gun was on or near the body but not in the hand (i.e., touching the body or within 30 cm of the body). The gun was found >30 cm from the body in the remaining 7% of cases. In the case of handguns, the gun was found in the hand in 25.7% of individuals. For individuals using long guns, the firearm was in the hand of the decedent in 19.5% of cases. The gun had a greater chance of remaining in the deceased's hand if the person was lying or sitting when the gunshot wound was received. Variables such as gender of the individual, wound location, and caliber of handgun were not significant in predicting whether the gun stayed in the hand after a suicidal gunshot wound.  相似文献   

3.
A study of the chemical contents and sizes of gunshot residue originating from 9×18mm PM ammunition, depositing in the vicinity of the shooting person was performed by means of scanning electron microscopy and energy dispersive X-ray spectrometry. Samples of the residue were collected from targets placed at various distances in the range 0-100cm as well as from hands and clothing of the shooting person. Targets were covered by fragments of white cotton fabric or black bovine leather. In the case of cotton targets microtraces were collected from circles of 5 and 10cm in radius. Results of the examinations in the form of numbers of particles, proportions of their chemical classes and dimensions revealed a dependence on the distance from the gun muzzle, both in the direction of shooting and in the opposite one, i.e., on the shooting person. The parameters describing gunshot residue differed also depending on the kind of the target substrate. The kind of obtained information gives rise to understanding the general rules of the dispersion of gunshot residue in the surroundings of the shooting gun. Thus, it may be utilised in the reconstruction of shooting incidences, especially in establishing the mutual positions of the shooter and other participants of the incident.  相似文献   

4.
Blank firing guns are readily accessible in most countries due to an absence of legal regulations. These weapons are capable of causing lethal injuries. We report a rare case of secondary (unplanned) complex suicide committed with a knife and blank cartridge pistol. A 59‐year‐old man was found dead with three superficial incisions in his neck and a gunshot wound to the chest. The external examination revealed an entrance wound in the left chest region consistent with contact shooting. The appearance of a muzzle imprint suggested two discharges. The autopsy showed a slightly hemorrhaged but otherwise intact pericardium, blood in the pericardial sac, and a channel‐like defect in the anterior wall of the left cardiac ventricle. The cause of death was attributed to cardiac tamponade. To the best of our knowledge, this is the first reported case of unplanned complex suicide involving an unmodified blank firing gun.  相似文献   

5.
Three cases of planned complex suicide in a 3-year period are reported. A 40-year-old man was found dead, in his garage, hanging by his neck, with a gunshot in the head from a pen gun. A 50-year-old man was found dead in the sea with a gunshot to his head. A third man was found in a field hanging by a tree and burned. The investigation of the scenes and the methods used pointed toward a suicidal etiology. The main difference between planned complex suicide and those cases defined in medicolegal literature as combined suicides lies in the complex mechanism used by the victim as a protection against the failure of one of the mechanisms.  相似文献   

6.
In case of suicide, the presence of multiple entrance wounds is always suspicious. We report the case of a man who committed suicide by shooting himself three times in the chest and the skull with a submachine gun. The weapon seems to have been initially pointed in the precordium area with a lethal lesion of the proximal aorta. Two other projectiles were fired by the weapon and hit the neck and the skull of the deceased. The presence of three entrance wounds despite a first fatal wound could finally be explained by the characteristics of the weapon and wounds. Most suicides related to multiple gunshot wounds are explained by a first nonlethal shot but the use of an automatic weapon can also be found. In these last cases, medicolegal and criminalistics aspects become important in differentiating suicide and homicide.  相似文献   

7.
Zip guns and the atypical gunshot wounds they produce are rare in forensic pathology. Because of this, investigators and forensic pathologists may be unfamiliar with their construction, appearance, and the wounds associated with them. A 43-year-old mechanic, with a history of depression was found dead in a washroom stall at work with an atypical gunshot wound of the head. Upon initial investigation, no weapon was found at the scene. Due to the nature of the scene, and the unusual characteristics of the wound, the manner of death was at first thought to be a homicide. Subsequently, a simple zip gun, which had been overlooked during the scene investigation, was discovered by a co-worker while he was cleaning the stall. Examination of the wound revealed evidence of contact range firing. A markedly deformed bullet was recovered from the head, consistent with the use of the home-made gun. These findings, along with further police investigation and review of the past medical history, indicated that the manner of death was a suicide.  相似文献   

8.
Abstract:  Home-made guns are imitations of typical firearms and usually have handgun characteristics. This article presents an unusual case of a suicide carried out by means of a fatal gunshot wound to the head using a home-made zip gun. A 49-year-old male, with a history of paranoid psychosis was found dead in the dwelling place of a family house. The investigation at the crime scene did not lead to suspicion of a gunshot wound because of the unusual nature of the firearm used. A medical examiner diagnosed an opened head injury as the primary cause of the victim's death. The autopsy findings provided immediate grounds for further inspection of the crime scene. Subsequently, a simple zip gun, which had been overlooked during the scene investigation, was discovered. An undeformed projectile recovered from the victim's head was consistent with the use of the home-made firearm. Following the completion of the investigations and autopsy, the death was classified as a suicide.  相似文献   

9.
利用颅骨枪弹创骨折类型推断射击方向和顺序的实验   总被引:1,自引:0,他引:1  
建立利用颅骨枪弹创骨折类型推断射击方向和顺序的方法。使用国产五四式7.62mm口径手枪及五六式7.62mm口径半自动步枪,以3m的距离2次射击16具尸体的头颞部及枕部,造成颅脑贯通创,制成颅骨枪弹射入、出口各32例,并根据定位标记进行观察。结果显示:颅骨枪弹创骨折形态可分为带有斜面的孔状骨折,锁孔状骨折,放射状骨折和环状隆起骨折4种类型,其出现多见于低速枪射击,并与射击方向和顺序有直接关系。根据颅骨枪弹创骨折类型可推断射击方向和顺序。  相似文献   

10.
《Science & justice》2023,63(3):396-405
The subject of this research was the inorganic gunshot residue component collected from shooting patterns obtained on woven cotton cloth using a Pietro Beretta model 70 pistol, cal. 7.65 mm and Serbian ammunition for the following muzzle-to-target distances: 25, 50, 75, 100 and 125 cm. For each distance, three rounds of shooting were performed. Particles were lifted within a 10 cm radius of the projectile entrance and automatically analyzed using a scanning electron microscope coupled with an energy dispersion X-ray spectrometry. The obtained data on the populations of particles were analyzed taking into account their numbers, chemical classes and sizes. The results showed an apparent maximum incidence within all particles containing barium at about 50 cm distance. Also, lead particles revealed a distinct behaviour, being dominant at a 25 cm distance, falling below the other chemical classes, and finally becoming dominant again at 125 cm. The analysis of the frequency of occurrence of particles sorted according to their sizes confirmed that the small particle population is the largest, and their distribution in function of the equivalent circle diameter is exponential-like. The obtained results provided knowledge on the distribution of particles in the vicinity of the tested firearm and ammunition cal. 7.65 mm which generally corroborates with similarly studied GSR distributions obtained for the use of pistols cal. 9 mm. This information, together with the examinations of gunshot damages and other types of residues such as soot or unburned propellant grains may support qualitative inferences on shooting distance estimation, especially in cases, when the firearm and cartridges are not available to perform test shooting. In such cases even roughly estimated shooting distance can be helpful, e.g. for confirming or excluding the possibility of self-inflicted injuries or suicide and infer on the mutual position of the shooting stage actors. An example of casework that illustrates intermediate shooting distance estimation is presented.  相似文献   

11.
目的研究79式微型冲锋枪发射子弹的排序。方法对已知顺序实弹射击取样,扩大观察弹头、弹壳上发射过程中形成的痕迹,通过统计、归纳,从中发现与排序有关的痕迹特征。结果壳体肩部圆点痕,弹底边缘压擦痕、拉壳钩痕与发射顺序有关。结论壳体肩部圆点痕、弹底边缘压擦痕等痕迹的有无、位置及轻重程度,对判断79式微型冲锋枪弹壳发射顺序有较可靠的参考价值。  相似文献   

12.
The second part of the paper on suicides by gunshots to the head in the presence of witnesses focuses on relevant morphological autopsy findings such as entrance site, signs of close range or contact shots, bullet path etc. and also discusses selected aspects of ascertaining gunshot residues. For the identification of the shooter an integral medicolegal assessment of all the facts including the investigation results and the autopsy findings is essential. However, the morphological findings alone do not allow safe diagnosis, as for example in a homicide the temporal region, which was affected in all our cases, may have been deliberately chosen by the perpetrator as a localization typical of suicide. Thus methods to ascertain gunshot residues on the firing hand (by means of adhesive films and the polyvinyl-alcohol collection method--PVAL) are of great practical importance. In seven cases adhesive films and/or the polyvinyl-alcohol collection method were used. In one case the gunshot residues (GSR) were analysed by means of tape lifts and subsequent scanning electron microscopy (SEM). It was found that especially the combined application of topographical (adhesive tape/PVAL) and cumulative (SEM) methods allowed for the doubtless identification of the shooter, thus usually confirming the suicide. By the example of one case it is demonstrated that without the immediate collection of evidence at the scene objective reconstruction of the event becomes impossible. On the basis of the reported cases recommendations are finally given for a differentiated approach in the medicolegal evaluation of alleged witnessed suicide by gunshot (to the head).  相似文献   

13.
When a gun is fired, it leaves marks on cartridge cases that are thought to be unique to the gun. In current practice, firearms examiners inspect cartridge cases for “sufficient agreement,” in which case they conclude that they come from the same gun, testifying in courts as such. A 2016 President's Council of Advisors on Science and Technology report questioned the scientific validity of such analysis (President's Committee of Advisors on Science and Technology, Washington, DC, Executive Office of the President). One recommendation was to convert firearms analysis to an objective method. We propose a fully automated, open‐source method for comparing breechface marks on cartridge cases using 2D optical images. We improve on existing methodology by automating the selection of marks, and removing the effects of circular symmetry. We propose an empirical computation of a “random match probability” given a known database, which can be used to quantify the weight of evidence. We demonstrate an improvement in accuracy on images from controlled test fires.  相似文献   

14.
Abstract: In this report, the authors present a case of suicide committed by a 66-year-old man, inside a grave at the local cemetery, with two gunshot wounds to the head. A multiple-paged, handwritten suicide note was found in an army type bag inside the victim’s car, while a second one was found in his house. Medicolegal examination of the body revealed two typical contact gunshot entrance wounds and one exit wound to the head. Toxicological analysis of the femoral blood was negative for alcohol and drugs. The history, scene and autopsy findings, along with further police investigation, indicated an obvious case of suicide. The literature is reviewed and discussed. We report this case as the place of suicide is extremely uncommon and as there is no mention of a gunshot suicide inside a grave in the current literature.  相似文献   

15.
目的利用环境控制扫描电镜/能谱仪(SEM/EDX)研究枪弹创射入口周围射击残留物与射击距离的关系,探讨其能否用于射击距离的判断。方法采用""5.4""式手枪分别在5、10、15、20、30、40、50、60、70、80、90、120cm处射击乳猪皮肤,利用SEM/EDX观察创口周围GSR的分布和成分,并建立回归方程。结果射击距离和GSR颗粒数量之间总体表现为直线关系,并建立了相应的回归方程。当射击距离为10~90cm时,用该方程推断射击距离效果较好。结论检测创口周围GSR可望用于判断“5.4”式手枪的射击距离。  相似文献   

16.
The study was made of gunshot perforating fractures of calvarial bones in cases of lethal perforating head wounds in long distance shots from a 9-mm Makarov gun. Morphological characteristics of inlet and outlet perforating fractures and bone fragments were found to differ. Gunshot fractures in calvarial bones inflicted by bullets from a 9-mm Makarov gun were studied in experiments with different kinetic energy. In low kinetic energy, bullets make oval holes on the outer table of the skull and round holes on the inner table with radial prominences on the walls of bullet channels, large bone fragments; in moderate kinetic energy--make round holes in the outer table and oval on the inner table with skew prominences on the walls of the outlet part of the channels, large and middle-sized flat bone fragments; in high kinetic energy injuries on both tables were round, prominences were cross, bone fragments were flat, small and middle-sized.  相似文献   

17.
A remarkable case of complex suicide with poisoning and multiple self-inflicted gunshot wounds to the head is reported. After ingestion of a liquid insecticide, the victim shot himself twice in the head, once in each temple. Self-manufactured wooden dowels were used as projectiles in combination with conventional blank cartridges. The dowels had been glued on top of the blank cartridges and expelled by propellant gases. Moreover, the blank revolver used had been extensively manipulated in a rarely observed manner. Several occlusive devices had been removed from the barrel and the cylinder chamber to enable the expulsion of the wooden projectiles. The investigation of the methods used and the circumstances found at the scene pointed towards a planned complex suicide. A remarkable case with unusual projectiles, i.e., wooden dowels, fired by an extensively manipulated blank gun is reported, emphasizing the importance of close collaboration between the police firearm laboratory and forensic pathology in practical casework.  相似文献   

18.
Experimental shots from a No. 16 calibre single-barrelled gun using commercial cartridges in the plastic cartridge cases supplied by wad containers with Nos. 1 and 2 shots revealed that lesions that had typical morphologic structure which were characteristic of wad container action were produced at close distances (less than 2 meters). Therefore preliminary experimental shots are necessary before making concrete decisions on characteristic features of an injuring projectile and shot distance.  相似文献   

19.
Many Americans own guns to protect themselves against other people, but there is evidence that both victimization and gun access increase suicide risk. We conducted qualitative interviews with informants of 17 suicide cases in New Orleans of the 60 who died between January 2015 and April 2016 to understand the relationship between past trauma, gun access and storage, and suicide. Nine cases had experienced a past trauma, including three who had recently had a family member killed by homicide. Eight died via firearm; of those, seven owned the guns they used to take their lives and stored them locked (but loaded) at home or in their cars. Preventing community violence and addressing its sequelae may be important for reducing suicides. A multi‐pronged strategy consisting of policies, education, and marketing will likely be needed to address the risk of suicide conferred by gun access.  相似文献   

20.
During the period of one year, the Police of the State of Espírito Santo in Brazil analyzed 1,431 cartridge cases obtained from crime scenes and seizures. The cartridges were subjected to a development sequence (cyanoacrylate fuming + gun bluing + fluorescent dying), and panoramic images of the developed fingermarks were generated based on the photographs taken during the rotation of the cartridges. Ridge details were observed in 50 cartridges, but only in 5 cartridges, the marks were considered with value for identification. The fingermarks were searched in the Automated Fingerprint Identification System (AFIS) of the Brazilian Federal Police and, in one case, it was possible to obtain the suspect's identification. In our knowledge, this is the first case in Brazil of identification of a suspect based on a fingermark recovered from a fired cartridge case.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号