首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 30 毫秒
1.
目的研制适用于数据库样本荧光STR直接复合扩增体系。方法针对常规血卡、FTA和903血卡样本,配制扩增缓冲液基准母液,采用不同配方的扩增缓冲体系进行直接扩增及检测。考察不同种类增强剂、4种商业化DNA聚合酶、不同复性温度和终延伸时间对检材的检测效果,并验证优化体系的适应性。结果采用本文所建体系对各类血卡样本进行检验,均可获得样本清晰、完整的STR分型。体系选择BSA\Tween20\DMSO\甘油等增强剂组合、Typer热启动聚合酶1.5U/10μL、57~59℃复性温度、30~50min终延伸时间,采用10μL体系即可对直径1.2mm FTA卡血样进行有效分型。结论本文所研制的缓冲体系能够满足常规血卡、FTA和903血卡样本直接扩增检验的需要。  相似文献   

2.
A continual challenge in the field of forensic DNA analysis is the amplification and interpretation of degraded and low-copy number (LCN) DNA obtained from amounts of limited biological evidence. It has been well established that DNA profiles obtained from the amplification of low quality, degraded, and/or LCN DNA samples are often of limited value due to the frequent occurrence of preferential amplification during polymerase chain reaction (PCR). The by-products of preferential PCR amplification are often observed as inter- and intra-locus peak imbalance, allelic dropout, and/or locus dropout. These are all artifacts that are identified during the interpretation phase of analysis rather than by improving the quality of the DNA present. While it is theoretically possible to obtain a complete DNA profile from a single cell, in reality, profiles obtained from suboptimal amounts of DNA are difficult to interpret and frequently inconsistent when replicated. Inspired by advances in next-generation sequencing techniques, we propose a methodology for simultaneously normalizing the abundance of PCR products across all short tandem repeat (STR) loci using the DNA exonuclease, duplex-specific nuclease (DSN). DSN is an enzyme isolated from the hepatopancreas of Red King (Kamchatka) crab that possesses a strong affinity for digesting double stranded DNA (dsDNA) and has limited activity toward single stranded DNA (ssDNA). Degraded DNA known to display peak imbalance and allele dropout was amplified using AmpFlSTR® Identifiler® Plus for 28 cycles. Following amplification, samples were denatured at 99.9 °C for 5 min and incubated with one unit of DSN at 62 °C in a 28 μl volume for 1 min. Nuclease activity was terminated through the addition of equal volume of 10 mM EDTA and 95 °C incubation for 2 min. Following DSN treatment, 21 of 30 alleles within the known profile exhibited some improvement in peak height balance. The findings obtained support the potential use of DSN treatment as a method for normalizing STR profiles and improving the quality of data from degraded and low quantity DNA samples.  相似文献   

3.
The AmpF?STR Yfiler PCR Amplification (Yfiler) kit continues to be improved for a better analytical efficiency in cases of highly degraded DNA. The authors endeavored to determine whether coupling of the Yfiler kit with supplemental multiplex amplification of some Y‐STR loci is a more efficient analytical mode for poorly preserved human femurs (n = 15) discovered at Korean archeological sites. To reveal locus profiles not easily obtained by Yfiler analysis, custom‐designed primers were adopted for the DYS390, DYS391, DYS392, DYS438, DYS439, and DYS635 loci. The success rate for 16 Y‐STR locus profiles obtained from the 15 femurs was improved from 18.33% (in the use of Yfiler kit only) to 49.17% (the coupled use of Yfiler and custom‐designed primers). In this study, the authors established that the custom‐designed primers offer a markedly improved success rate for obtainment of Y‐STR profiles from degraded aDNA not easily identified by sole use of the Yfiler assay.  相似文献   

4.
FTA Cards (GE Healthcare) have been used for more than 4 years in Denmark for the collection of buccal cells as reference samples in crime cases. Semi-automated protocols for STR typing of DNA on punches of FTA Cards are routinely used. In average, full STR profiles were generated from approximately 95% of the FTA Cards with a standard punching protocol, while partial or no STR profile were obtained from 5% of the samples. Here, the Qiagen BioRobot® EZ1 Workstation (Qiagen) and the EZ1 DNA Investigator Kit (Qiagen) was used to extract DNA from 29 FTA Cards from which a complete STR profile was not generated with the standard punching protocol. All 29 samples were successfully typed with the AmpF?STR® Identifiler™ PCR Amplification Kit (Applied Biosystems) and with the SNPforID 49plex SNP assay. The lowest amount of DNA that resulted in complete STR and SNP profiles was 80 pg. The STR and SNP profiles were identical to those generated from another sample collected from each of the 29 individuals.  相似文献   

5.
AGCU免提取STR荧光检测试剂盒的验证   总被引:4,自引:1,他引:3  
目的考察AGCU免提取STR荧光检测试剂盒.对保存在滤纸片或FTA卡上血液样本的直接扩增检测情况。方法使用人GCU免提取STR荧光检测试剂盒,对未经提取的滤纸片血液样本、FTA卡血液样本675份进行直接扩增和18个基因座的DNA分型,并对结果的可靠性进行研究。结果18个基因座检测结果与PP16和ID试剂盒分型结果一致,2000年数据库样本成功率92.3%,2001年数据库样本成功率92.6%,2004以后年数据样本及案件样本、亲子鉴定样本成功率在99%以上。结论AGCU试剂盒可以成功地对滤纸片、FTA卡样本的18个STR基因座进行直接扩增检测,检验结果稳定,分型准确。  相似文献   

6.
目的研制一种能够配合非直接扩增试剂应用的PCR缓冲增强剂,实现对FTA卡保存样本的直接扩增。方法基于常规STR复合扩增试剂盒的扩增体系及引物组,加入增强剂对FTA卡类样本进行直接扩增。结果获得样本STR分型结果清晰、完整、平衡性好,无明显抑制现象存在。结论所研制的FTA卡直扩增强剂能达到FTA卡保存样本的直接扩增检验要求,可应用于法医STR检验。  相似文献   

7.
The 1.2 mm Electric Coring Tool (e-Core™) was developed to increase the throughput of FTA sample collection cards used during forensic workflows and is similar to a 1.2 mm Harris manual micro-punch for sampling dried blood spots. Direct short tandem repeat (STR) DNA profiling was used to compare samples taken by the e-Core tool with those taken by the manual micro-punch. The performance of the e-Core device was evaluated using a commercially available PowerPlex™ 18D STR System. In addition, an analysis was performed that investigated the potential carryover of DNA via the e-Core punch from one FTA disc to another. This contamination study was carried out using Applied Biosystems AmpflSTR™ Identifiler™ Direct PCR Amplification kits. The e-Core instrument does not contaminate FTA discs when a cleaning punch is used following excision of discs containing samples and generates STR profiles that are comparable to those generated by the manual micro-punch.  相似文献   

8.
Abstract: The identification of missing casualties of the Korean War (1950–1953) has been performed using mitochondrial DNA (mtDNA) profiles, but recent advances in DNA extraction techniques and approaches using smaller amplicons have significantly increased the possibility of obtaining DNA profiles from highly degraded skeletal remains. Therefore, 21 skeletal remains of Korean War victims and 24 samples from biological relatives of the supposed victims were selected based on circumstantial evidence and/or mtDNA‐matching results and were analyzed to confirm the alleged relationship. Cumulative likelihood ratios were obtained from autosomal short tandem repeat, Y‐chromosomal STR, and mtDNA‐genotyping results, and mainly confirmed the alleged relationship with values over 105. The present analysis emphasizes the value of mini‐ and Y‐STR systems as well as an efficient DNA extraction method in DNA testing for the identification of old skeletal remains.  相似文献   

9.
The DNA purification step has been thought to be essential for typing of STR DNA. However, this process is time-consuming, and there is a risk of unexpected cross-contamination during purification. We report a new method for direct short tandem repeat (STR) amplification using a newly developed direct PCR buffer, AnyDirect, which can amplify STR loci from whole blood and blood- or saliva-spotted FTA cards without DNA purification. The autosomal and Y chromosomal STR loci were analyzed for whole blood and blood or saliva spots of random individuals, followed by comparison of the results with those of corresponding purified DNA. The results from whole blood and blood spots showed perfect concordance with those from purified DNA without allele or locus drop-out. However, in the case of saliva spots, no amplification or locus drop-out was observed in some of the samples, which offers a topic for further study. Additionally, some commercial hot-start DNA polymerases other than AmpliTaq Gold DNA polymerase were also found to be compatible with this buffer system. Therefore, this direct PCR buffer was demonstrated to be useful for fast forensic DNA analysis or criminal DNA databases for which there is no need to store DNA samples.  相似文献   

10.
Forensic DNA analysis is a multi-step process involving extraction of DNA, quantification of human DNA in the extract, amplification using multiplex STR systems, separation of products, and data analysis. The backlog of forensic casework is increasing worldwide. Automation is one significant way to alleviate the bottleneck of sample processing in forensic labs. The HID EVOlution™ Combination System described here is a robust, reliable sample processing platform, easily adapted to forensic laboratory workflows. Using a variety of forensic sample types including: blood stained FTA paper, cotton fabric and denim, dried blood spiked with known PCR inhibitors, saliva on cotton swabs, and semen stains, we found that yields of human DNA and STR profiles obtained with AmpFlSTR® Idenitfiler® kits were complete, highly reproducible, and equivalent to results obtained using the manual PrepFiler™ reagent extraction method. Automated operation was clean, and no cross-contamination was detected between extraction blanks and interspersed high DNA content samples.  相似文献   

11.
Abstract: The Quantifiler® Duo DNA Quantification kit enables simultaneous quantification of human DNA and human male DNA as well as detection of inhibitors of PCR in a single real-time PCR well. Pooled human male genomic DNA is used to generate standard curves for both human (ribonuclease P RNA component H1) and human male (sex determining region Y) specific targets. A shift in the cycle threshold (CT) values for the internal positive control monitors the presence of PCR inhibitors in a sample. The assay is human specific and exhibits a high dynamic range from 0.023 to 50 ng/μL. In addition, the multiplex assay can detect as little as 25 pg/μL of human male DNA in the presence of a 1000-fold excess of human female DNA. The multiplex assay provides assessment of the DNA extract and guidance for the selection of the appropriate AmpFℓSTR® Amplification Kit to obtain interpretable short tandem repeat profiles.  相似文献   

12.
Most commercially available STR amplification kits have never been fully validated for low template DNA analysis, highlighting the need for testing different PCR kits and conditions for improving single-cell profiling. Here, current strategies rely mainly on adjusting PCR cycle number and analytical threshold settings, with a strong preference for using 30 amplification cycles and thresholds at 30–150 RFU for allele detection. This study aimed to (1) determine appropriate conditions for obtaining informative profiles utilizing a dilution series, and (2) test the outcome on single cells using the DEPArray™ technology. Four routinely applied forensic STR kits were compared by using three different amplification volumes and DNA dilutions down to 3.0 pg, while two well-performing kits were used for single/pooled leucocyte and sperm cell genotyping. Besides reduced costs, the results demonstrate that a 50%–75% PCR volume reduction was beneficial for peak height evaluation. However, this was counteracted by an increased artifact generation in diluted DNA volumes. Regarding profile completeness, the advantage of volume reduction was only prominent in samples processed with Fusion 6C. For single and pooled cells, ESIFast and NGMDetect provided a solid basis for consensus profiling regarding locus failure, although locus dropouts were generally observed as stochastic events. Amplification volume of 12.5 μL was confirmed as appropriate in terms of peak heights and stutter frequencies, with increased stutter peaks being the main artifact in single-cell profiles. Limitations associated with these analyses are discussed, providing a solid foundation for further studies on low template DNA.  相似文献   

13.
Forensic analysts routinely encounter samples containing DNA mixtures from male and female contributors. To obtain interpretable Short Tandem Repeat (STR) profiles and select the appropriate STR analysis methodology, it is desirable to determine relative quantities of male and female DNA, and detect PCR inhibitors. We describe a multiplex assay for simultaneous quantification of human and human male DNA using the ribonuclease P RNA component H1 (RPPH1) human target and the sex determining region Y (SRY) male-specific target. A synthetic oligonucleotide sequence was co-amplified as an internal PCR control. Standard curves were generated using human male genomic DNA. The SRY and RPPH1 assays demonstrated human specificity with minimal cross-reactivity to DNA from other species. Reproducible DNA concentrations were obtained within a range of 0.023-50 ng/μl. The assay was highly sensitive, detecting as little as 25 pg/μl of human male DNA in the presence of a thousand-fold excess of human female DNA. The ability of the assay to predict PCR inhibition was demonstrated by shifted IPC Ct values in the presence of increasing quantities of hematin and humic acid. We also demonstrate the correlation between the multiplex assay quantification results and the strength of STR profiles generated using the AmpF?STR®PCR Amplification kits.  相似文献   

14.
The PE‐Swab direct STR amplification workflow was developed to process low‐level “touch DNA” samples. In this workflow, a forensic sample is first collected on a 4‐mm PE‐Swab (a novel sample collection device); two 2‐mm punches containing collected samples are then generated from the PE‐Swab and directly amplified for STR typing. Compared to the conventional STR workflow, which involves DNA extraction, purification, and elution volume reduction, the PE‐Swab direct STR amplification workflow does not require sample preparation and takes <60 sec before a touch sample is ready for STR amplification. Because there is no DNA loss due to sample preparation, the PE‐Swab workflow is more sensitive than the conventional STR workflow. The average peak height per sample obtained by the PE‐swab workflow is 3 times higher than that from the conventional workflow with both low‐level single source and two‐contributor mixture samples tested in this study.  相似文献   

15.
The onus of proof in criminal cases is beyond any reasonable doubt, and the issue on the lack of complete internal validation data can be manipulated when it comes to justifying the validity and reliability of the X-chromosomal short tandem repeats analysis for court representation. Therefore, this research evaluated the efficiency of the optimized 60% reduced volumes for polymerase chain reaction (PCR) amplification using the Qiagen Investigator® Argus X-12 QS Kit, as well as the capillary electrophoresis (CE) sample preparation for blood samples on Flinder's Technology Associates (FTA) cards. Good-quality DNA profile (3000–12,000 RFU) from the purified blood sample on FTA card (1.2 mm) were obtained using the optimized PCR (10.0 μL of PCR reaction volume and 21 cycles) and CE (9.0 μL Hi-Di™ Formamide and 0.3 μL DNA Size Standard 550 [BTO] and 27 s injection time) conditions. The analytical and stochastic thresholds were 100 and 200 RFU, respectively. Hence, the internal validation data supported the use of the optimized 60% reduced PCR amplification reaction volume of the Qiagen Investigator® Argus X-12 QS Kit as well as the CE sample preparation for producing reliable DNA profiles that comply with the quality assurance standards for forensic DNA testing laboratories, while optimizing the analytical cost.  相似文献   

16.
Accurate quantification of DNA samples is an important step in obtaining accurate and reproducible short tandem repeat (STR) profiles. Quantitative real-time-PCR has improved the speed and accuracy of DNA quantification over earlier methods, albeit at significantly greater cost per reaction. Here, the performance of reduced volume (10 microL) DNA quantification assays using the Quantifiler Human DNA Quantification Kit was evaluated using commercial standards and single source biological stains (e.g., venous blood, saliva, and semen). In addition, casework-type samples including those subjected to environmental contaminants containing PCR inhibitors and samples having undergone extensive DNA degradation were also quantified. The concentration of DNA in various forensic samples ranged from 0 to 2.9 ng/microL depending on sample source and/or environmental insult. Compared to full-scale reactions, reduced volume assays displayed equivalent to improved amplification efficiency and sample-to-sample reproducibility (+/-0.01-0.17 C(T FAM)). Furthermore, the use of data from reduced-scale Quantifiler reactions facilitated the accurate determination of the amount of sample DNA extract needed to generate quality STR profiles. The use of 10 microL-scale Quantifiler reaction volumes has the practical benefit of increasing the effective number of reactions per kit by 250%; thereby reducing the cost per assay by 60% while consuming less sample. This is particularly advantageous in cases of consumptive testing.  相似文献   

17.
The quantity of mitochondrial DNA (mtDNA) template added for amplification and subsequent dye terminator reactions is critical for obtaining quality sequence data. Validation of a human mtDNA real‐time quantitative PCR (qPCR) assay demonstrated its high degree of reproducibility and precision as well as an extremely sensitive threshold of detection (0.0001 pg/μL or approximately six human mtDNA copies/μL). A study of 35 nonprobative bone and teeth evidence samples revealed that 20 pg of mtDNA template is recommended for successful HV1 and HV2 sequence analysis; however, as little as 0.013 pg can generate a full mtDNA profile when using enhanced amplification reactions. The assay can also detect PCR inhibition and is useful for identifying samples that may benefit from re‐purification. Overall, the assay is an excellent method to quantify mtDNA and is useful for determining the best analytical approach for successful sequencing.  相似文献   

18.
目的测试DNA TyperTM15 plus直扩试剂盒的技术性能指标,评价其在DNA数据库建设中的应用价值。方法采用DNA TyperTM15 plus试剂盒,并使用IdentifilerTM和DNA TyperTM15试剂盒进行比较,设定不同体系和引物量、不同退火温度和循环次数以进行方法验证;设定不同模板量标准品、不同比例混合样本,取猪、狗、兔等动物的血液样品,血痕、骨骼、唾液斑等常见检材样本以及不同建库样本,以验证试剂盒灵敏度、特异性、稳定性以及混合样本、常见检材及建库样本的检测能力。结果直扩试剂盒分型结果准确,重复性好,灵敏度可达0.125ng,不同批次间试剂检测结果稳定,对不同检材有很好的适应性。10μL扩增体系时FTA卡和加强型血液采集卡取样直径应为0.5mm,而血滤纸、血液采集卡样本和经典型血液采集卡取样直径应为1.0mm。结论 DNA TyperTM15 plus直扩试剂盒的性能可以满足DNA数据库建设及检案的需要,可在相关实验中选择使用。  相似文献   

19.
Abstract:  Evidentiary traces may contain low quantities of DNA, and regularly incomplete short tandem repeat (STR) profiles are obtained. In this study, higher capillary electrophoresis injection settings were used to efficiently improve incomplete STR profiles generated from low-level DNA samples under standard polymerase chain reaction (PCR) conditions. The method involves capillary electrophoresis with higher injection voltage and extended injection time. STR peak heights increased six-fold. Inherent to the analysis of low-level DNA samples, we observed stochastic amplification artifacts, mainly in the form of allele dropout and heterozygous peak imbalance. Increased stutter ratios and allele drop-in were rarely seen. Upon STR typing of 10:1 admixed samples, the profile of the major component did not become overloaded when using higher injection settings as was observed upon elevated cycling. Thereby an improved profile of the minor component was obtained. For low-level DNA casework samples, we adhere to independent replication of the PCR amplification and boosted capillary electrophoresis.  相似文献   

20.
When using non-FTA cards in commercial multiplex STR kits for direct PCR, pretreatment steps with specific buffers are recommended. Here, we designed a rapid direct PCR method utilizing a non-FTA card, Oral Cell Sampling Kit, by omitting the pretreatment step involving Prep-n-Go™ Buffer, and it showed compatibility with the GlobalFiler™ Express PCR Amplification Kit, GlobalFiler™ PCR Amplification Kit, and PowerPlex® Fusion system. To optimize the PCR conditions, we tested the method with different final PCR volumes and cycles. Finally, we conducted a performance test using 50 Korean buccal samples and confirmed the high performance of the method, detecting more than 90% of the samples with full profiles when using GlobalFiler™ PCR Amplification Kit and PowerPlex® Fusion system at 29 cycles in a 10 μL final PCR volume. Thus, we report a simple direct PCR set-up to analyze reference samples collected using a non-FTA card manufactured in Korea.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号