首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 734 毫秒
1.
Currently, no established methodology exists to determine degradation patterns of latent fingermarks by visual means. This article is the second in a series of reports exploring quantifiable degradation‐related parameters, which focuses on color contrast changes between fingermark ridges and furrows over time. Experiment variables included type of secretion (eccrine and sebaceous), substrate (glass and plastic), and exposure to natural light (dark, shade, and direct light). Fingermarks were sequentially visualized with titanium dioxide powder and photographed. Image histogram profiles were evaluated and combined with statistical analysis of color data values. Results indicate that sebaceous depositions on glass were generally less degraded by the effect of environmental conditions compared with those on plastic. In addition, aging in darkness was not always the best condition for preservation, and direct exposure to light seemed to inhibit visual degradation under certain conditions. Overall, the technique provided sufficient sensitivity to discern degradation patterns of fingermarks.  相似文献   

2.
This fourth article of the series is taking an in‐depth analysis at the visible aging of latent fingermarks regarding changes in ridge widths over time. The objective is to quantify and statistically describe significant ridge size variations under controlled indoor conditions. The effect of three environmental variables are examined: type of secretion (sebaceous‐ and eccrine‐rich) and type of substrate (glass and polystyrene) when aged in three light conditions (direct natural light, shade, and dark). Prior to width measurements, fresh and aged fingermarks were powdered with titanium dioxide (TiO2) and sequentially photographed at predetermined times over 6 months. Three independent observers measured the ridges from thirty predetermined locations using strategically placed intersecting lines on the print. Results indicate that fingermarks deposited on glass are more resilient to degradation compared with those deposited on plastic. The presence of direct natural light plays a negligible role on degradation compared to secretion and substrate types.  相似文献   

3.
This article is the third in a series of reports exploring quantifiable visual parameters of the aging process of latent fingermarks. On this occasion, research is focused on the occurrence of ridge discontinuities (i.e. breakages) as a function of time. Experiment variables included type of secretion (eccrine and sebaceous), substrate (glass and plastic), and exposure to natural light (dark, shade, and direct light) over a 6 months period. Fingermarks were sequentially visualized with titanium dioxide powder, photographed, and the number of naturally occurring ridge discontinuities subsequently evaluated. A semi‐quantitative value, named Discontinuity Index, was used to better characterize this aging parameter. Results indicated that ridges of sebaceous depositions on glass were generally less affected by the environmental conditions compared with those on plastic surface. In addition, aging in darkness was not always the best condition for preservation, and the direct exposure to light seemed not to affect the degradation under certain conditions.  相似文献   

4.
Corrosion of α‐phase brass by sebaceous sweat fingerprint deposits produced identifiable impressions in a majority of samples (n = 40) 4 days after deposition. Combining sebaceous with eccrine sweat yielded a greater percentage of identifiable fingerprint deposits, although this increase was not statistically significant. Production of identifiable fingerprints from eccrine sweat deposits was dependent on the sampling time of year with deposits taken during summer months giving similar percentages of identifiable fingerprints to sebaceous deposits. A statistically significant positive correlation was found between elapsed days after deposition and identifiable eccrine (ρ = 0.787, p < 0.05), sebaceous (ρ = 0.724, p < 0.05), and eccrine/sebaceous mixture (ρ = 0.908, p < 0.01) fingerprints deposited during summer months. The summer increase in the percentage of identifiable eccrine sweat deposits was statistically significant compared to winter eccrine deposits (p < 0.0001). Observations were consistent with results obtained from artificial sebaceous and eccrine sweat.  相似文献   

5.
One of the crucial factors determining the cyanoacrylate deposit quality over latent fingerprints appeared to be the extent of the humidity. This work focuses on the enhancement/refreshment of age‐degraded latent fingerprints by irradiating the samples with UV, X‐ray, or thermal neutrons prior to the cyanoacrylate (CA) fuming. Age degradation of latent fingerprints deposited on glass surfaces was examined through the decrease in the number of characteristic minutiae counts over time. A term “critical day” was introduced for the time at which the average number of identifiable minutiae definitions drops to one‐half. Fingerprints older than their “critical day” were exposed to either UV, X‐ray, or thermal neutrons. Identical reference samples were kept unexposed. All samples, both reference and irradiated, were developed during a single CA fuming procedure. Comparative latent fingerprint analysis showed that exposure to ionizing radiation enhances the CA fuming, yielding a 20‐30% increase in average minutiae count.  相似文献   

6.
The thermal development of latent fingerprints on paper surfaces is a simple, safe, and chemicals‐free method, based on the faster heating of the substrate underlying the print residue. Microwave heating is proposed for the first time for the development of latent fingerprints on cellulose‐based substrate, in order to add to the thermal development mechanism the further characteristic of being able to heat the fingerprint residues to a different extent with respect to the substrate, due to the intrinsic difference in their dielectric properties. Numerical simulation was performed to confirm and highlight the selectivity of microwaves, and preliminary experimental results point out the great potentialities of this technique, which allowed developing both latent sebaceous‐rich and latent eccrine‐rich fingerprints on different porous surfaces, in less than 30 sec time with an applied output power of 500 W. Microwaves demonstrated more effectiveness in the development of eccrine‐rich residues, aged up to 12 weeks.  相似文献   

7.
Research has been conducted to establish the effect that changes in relative humidity have on both the effectiveness of the cyanoacrylate fuming technique and the microstructures formed by the polymerisation reaction during the development of the marks. The study investigated 'natural' fingermarks and deliberately groomed eccrine and sebaceous marks, all exposed to relative humidity levels in the range 60-100%. It was found that the optimum level of relative humidity for the development of the most high quality marks is approximately 80%, in accord with current recommendations for operational implementation which are based on previous unpublished work. The eccrine constituents of the fingerprints are most influenced by humidity changes. Three humidity regimes were identified, each giving different polycyanoacrylate microstructures. Humidity levels of 60% give flat, film-like structures whereas in the range 70-90% the characteristic noodle-like structure is formed. At higher humidities, thin, flat thread-like growth is observed with some 'collapsed sphere' structures observed close to pores and significant background development. The noodle-like structures are thought to scatter more light and retain fluorescent dye better than the structures formed at other humidity levels. Sebaceous marks produce a very different polymer microstructure, resembling a flat film with some fine nodular structures.  相似文献   

8.
In this work we present our observations on the interaction between metallic (copper, aluminum, iron, brass, zinc) and non-metallic (glass and plastic) surfaces bearing latent fingermarks and several aqueous electrolytic solutions. Good quality fingermarks could be observed on some of the metallic and even on non-metallic surfaces after such treatment. The influence of factors such as time interval from deposition, pH of the electrolytes, wiping the latent marks prior to processing and the presence of a second metal on the quality and permanence of the developed impressions have been studied. As a rule, sebaceous marks provided much better quality impressions on all the surfaces. Initial explanations based on electrochemical processes are suggested.  相似文献   

9.
We have studied the degradation of sebaceous fingerprints on brass surfaces using silver electroless deposition (SED) as a visualization technique. We have stored fingerprints on brass squares either (i) in a locked dark cupboard or (ii) in glass‐filtered natural daylight for periods of 3 h, 24 h, 1 week, 3 weeks, and 6 weeks. We find that fingerprints on brass surfaces degrade much more rapidly when kept in the light than they do under dark conditions with a much higher proportion of high‐quality prints found after 3 or 6 weeks of aging when stored in the dark. This process is more marked than for similar fingerprints on black PVC surfaces. Identifiable prints can be achieved on brass surfaces using both SED and cyanoacrylate fuming (CFM). SED is quick and straightforward to perform. CFM is more time‐consuming but is versatile and can be applied to a wider range of metal surfaces than SED, for example brass surfaces which have been coated by a lacquer.  相似文献   

10.
《Science & justice》2021,61(5):635-648
A variety of suspended silica and metal nanoparticles have been used over the last 20 years to enhance latent fingermarks. This study quantitatively evaluates enhancement of natural and sebum-enriched fingermarks from three adult subjects acquired with a consistent applied force on glass with a fingermark press using suspended commercially available polystyrene (PS) particles. Images of the enhanced fingermarks acquired with total internal reflection (TIR), or standard overhead white light (WL), illumination are compared with fingermarks enhanced with conventional methods including cyanoacrylate fuming. The different enhancement and illumination methods are quantified based on the brightness and contrast of the fingermark images, as well as the number of minutiae that can be identified and matched to those on an inked manually acquired “template” fingermark using automatic fingerprint identification system (AFIS) software. Enhanced fingermarks acquired with the press are shown to be more consistent than manually acquired fingermarks based on these metrics. The results demonstrate that TIR illumination from a large-area illuminator built in house gives enhanced fingermark images with more matched minutiae and contrast superior to that for WL illumination for all types of enhancement. “Wet-powdering” with PS particles gives fingermark images that are for the most part comparable in terms of the number of matched minutiae to fingermarks enhanced with more conventional methods, suggesting that this novel enhancement method has a performance comparable to conventional enhancement methods. Interestingly, the age of the fingermark appears to have almost no effect on this new type of enhancement; sebum-enriched fingermarks ranging in age from 12 h to 435 days appear to have statistically identical numbers of matched minutiae.  相似文献   

11.
Abstract: Few techniques offer “in situ” methods of friction ridge skin mark development. “In situ” development reduces mark transportation, degradation, and often cost. The effectiveness of cyanoacrylate fuming using the SUPERfume® and dusting with aluminum powder for latent fingermark development on several nonporous surfaces, stored in various temperature environments for time periods up to 52 weeks, was investigated. Five thousand and four hundred latent fingermarks were deposited under controlled conditions and graded. The results suggested that cyanoacrylate fuming (SUPERfume®, Foster and Freeman, U.K.) was more effective at developing latent fingermarks on textured and smooth plastic surfaces and for marks stored in temperatures of 37°C, whereas aluminum powder was more effective on glass, enameled metal paint, and varnished wood, and for storage temperatures below 20°C. There were no significant benefits to using either technique for marks older than 24 h, but it was possible to develop fingermarks following 52 weeks of storage using both techniques.  相似文献   

12.
目的 建立NaYF4∶Er,Yb微粒悬浮液显现手印技术方法并界定适用范围与条件.方法 用NaYF4∶Er,Yb微粒悬浮液显现瓷砖、玻璃等19种(各50枚)不同客体上皮脂汗手印,并对结果进行分析比较.结果 该方法对背景复杂的非渗透性客体上的油汗手印显现良好,其效果优于普通ZnO小颗粒悬浮液.结论 该方法操作简便、适用客体广泛、背景干扰少,适合进一步研究推广.  相似文献   

13.
The ability of two mass spectrometric methods, surface-assisted laser desorption/ionization-time of flight-mass spectrometry (SALDI-TOF-MS) and direct analysis in real time (DART-MS), to detect the presence of seven common explosives (six nitro-organic- and one peroxide-type) in spiked latent fingermarks has been examined. It was found that each explosive could be detected with nanogram sensitivity for marks resulting from direct finger contact with a glass probe by DART-MS or onto stainless steel target plates using SALDI-TOF-MS for marks pre-dusted with one type of commercial black magnetic powder. These explosives also could be detected in latent marks lifted from six common surfaces (paper, plastic bag, metal drinks can, wood laminate, adhesive tape and white ceramic tile) whereas no explosive could be detected in equivalent pre-dusted marks on the surface of a commercial lifting tape by the DART-MS method due to high background interference from the tape material. The presence of TNT and Tetryl could be detected in pre-dusted latent fingermarks on a commercial lifting tape for up to 29 days sealed and stored under ambient conditions.  相似文献   

14.
The study presented in this paper aims at assessing how printed fingermarks can be used to generate realistic latent marks bearing varying quantities of materials to be detected. Considering dilution series of artificial sweat (eccrine secretion) and 1,2-indanedione/zinc as amino acid reagent, we assessed how printed marks behave in comparison to natural fingermarks provided by a set of 30 donors. The results were assessed in terms of relative intensity (contrast, luminescence) and expert grading (ridge details, overall quality). With regards to the set of 30 donors, this study brought a quantitative look to the influence of intra- and inter-variability on the relative intensity values observed when processing natural fingermarks. This provided new data to further understand the concept of “donorship”. With regards to the use of printed marks, it has been illustrated how dilution series of a concentrated solution allows covering a range of cases: unnatural marks (intensity values well above those obtained with donors), rich marks (corresponding to fingermarks left by good donors), and faint marks (associated with the kind of results observed with poor donors). Such a range of detection performance offers the possibility to generate fine-tuned detection exercises of varying difficulty levels. Printed items made of artificial sweat could hence constitute a valuable alternative to natural secretions in the context of education and proficiency testing.  相似文献   

15.
We have carried out experiments to investigate the aging of latent fingerprints deposited on black PVC over a period of 4–15 weeks. A thumbprint was used in each case and before deposition of the print the donor rubbed their thumb around their nose to add sebaceous deposits. We have studied the effect of heat, light, and moisture and we find that moisture is the most significant factor in the degradation of the latent print. We have attempted to enhance these latent prints by dusting with valine powder or powders composed of valine mixed with gold or red fluorescent commercial fingerprint powders. To make a direct comparison between “treated” and “untreated” prints, the prints were cut in half with one‐half being “treated” and one‐half not. Our studies show the best results being obtained when powders of valine and red fluorescent powders are applied prior to cyanoacrylate fuming.  相似文献   

16.
Abstract: Photo‐ and thermal‐degradation studies on eccrine fingerprint components are presented herein. Dilute distinct solutions of urea, lactic acid, and seven amino acids were deposited on steel coupons and Teflon® disks, exposed to artificial sunlight or heat, extracted, and analyzed. This aim of this study was to determine whether the investigated eccrine components, previously determined to be Raman active for a parallel study, experienced photo‐ or thermally induced degradation, and if so, to determine the rate and identify any detectable products. Neither the amino acids nor urea exhibited photo‐degradation; however, when heated for a period of three minutes, the onset of thermal‐degradation was initiated at 100°C for the amino acids and 100°C for urea. Lactic acid, the major polymerization initiator of superglue fuming, showed photochemical and thermal‐degradation. These results could be used for future development of new latent fingerprint visualization methods, especially when lactic acid is degraded.  相似文献   

17.
Abstract

THIS STUDY is about second‐year students’ self‐assessment in law. Its aims were to test how closely the assessment by the students of their own work matched that of their tutor, to give the students an insight into the “marking process” (which research has shown improves learning), to help the students excel in their examination, to find out whether the male students did better than the female students in their assignment and subsequent examination, and to see how far staff time could be saved. The following were found: there was a high level of agreement between the students’ own marks and those of the tutor, there was generally no significant over‐estimation of assignment marks by the students, the participants did better than the non‐participants in the subsequent examination, the female students did much better than the male students in the assignments as well as the examination (although the participants in general did not do better in their examination than they did in their assignment) and considerable staff time was saved. The findings are discussed in the light of previous research.  相似文献   

18.
As part of the Forensic Ear Identification (FearID) research project, which aims to obtain estimators for the strength of evidence of earmarks found on crime scenes, a large database of earprints (over 1200 donors) has been collected. Starting from a knowledge-based approach where experts add anatomical annotations of minutiae and landmarks present in prints, comparison of pairs of prints is done using the method of Vector Template Matching (VTM). As the annotation process is subjective, a validation experiment was performed to study its stability. Comparing prints on the basis of VTM, it appears that there are interoperator effects, individual operators yielding significantly more consistent results when annotating prints than different operators. The operators being well trained and educated, the observed variation on both clicking frequency and choice of annotation points suggests that implementation of the above is not the best way to go about objectifying earprint comparison. Processes like the above are relevant for any forensic science dealing with identification (e.g., of glass, tool marks, fibers, faces, fingers, handwriting, speakers) where manual (nonautomated) processes play a role. In these cases, results may be operator dependent and the dependencies need to be studied.  相似文献   

19.
In recent studies, the evidential value of the similarity of minutiae configurations of fingermarks and fingerprints, for example expressed by automated fingerprint identification systems (AFIS), is determined by likelihood ratios (LRs). The paper explores whether there is an effect on LRs if conditioning takes place on specified fingers, fingerprints, or fingermarks under competing hypotheses: In addition, an approach is explored where conditioning is asymmetric. Comparisons between fingerprints and simulated fingermarks with eight minutiae are performed to produce similarity score distributions for each type of conditioning, given a fixed AFIS matching algorithm. Both similarity scores and LRs are significantly different if the conditioning changes. Given a common‐source scenario, “LRs” resulting from asymmetric conditioning are on average higher. The difference may reach a factor of 2000. As conditioning on a suspect's finger(print) is labor‐intensive and requires a cooperating suspect, it is recommended to just condition on the number of minutiae in the fingermark.  相似文献   

20.
Recent challenges and errors in fingerprint identification have highlighted the need for assessing the information content of a papillary pattern in a systematic way. In particular, estimation of the statistical uncertainty associated with this type of evidence is more and more called upon. The approach used in the present study is based on the assessment of likelihood ratios (LRs). This evaluative tool weighs the likelihood of evidence given two mutually exclusive hypotheses. The computation of likelihood ratios on a database of marks of known sources (matching the unknown and non-matching the unknown mark) allows an estimation of the evidential contribution of fingerprint evidence. LRs are computed taking advantage of the scores obtained from an automated fingerprint identification system and hence are based exclusively on level II features (minutiae). The AFIS system attributes a score to any comparison (fingerprint to fingerprint, mark to mark and mark to fingerprint), used here as a proximity measure between the respective arrangements of minutiae. The numerator of the LR addresses the within finger variability and is obtained by comparing the same configurations of minutiae coming from the same source. Only comparisons where the same minutiae are visible both on the mark and on the print are therefore taken into account. The denominator of the LR is obtained by cross-comparison with a database of prints originating from non-matching sources. The estimation of the numerator of the LR is much more complex in terms of specific data requirements than the estimation of the denominator of the LR (that requires only a large database of prints from an non-associated population). Hence this paper addresses specific issues associated with the numerator or within finger variability. This study aims at answering the following questions: (1) how a database for modelling within finger variability should be acquired; (2) whether or not the visualisation technique or the choice of different minutiae arrangements may influence that modelling and (3) what is the magnitude of LRs that can be expected from such a model. Results show that within finger variability is affected by the visualisation technique used on the mark, the number of minutiae and the minutiae configuration. They also show that the rates of misleading evidence in the likelihood ratios obtained for one of the configurations examined are low.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号