1.
化学显色法快速筛选饮料及尿液中γ-羟基丁酸和γ-丁内酯   总被引:1,自引:0,他引:1  
Zhang SY  Huang ZP 《法医学杂志》2006,22(6):424-427,F0004
目的建立化学显色法快速筛选饮料及尿液中γ-羟基丁酸(GHB)及其前体γ-丁内酯(GBL)的方法。方法在酸性条件下GHB转化为GBL,GBL和盐酸羟胺在碱性条件下生成γ-羟基丁酰羟胺,γ-羟基丁酰羟胺在酸性条件下和三氯化铁反应,生成紫红色的络合物。结果饮料中GHB最低检出浓度为0.5~2mg/mL,低于常见滥用质量浓度。该方法也可以用于尿液分析,最低检出质量浓度为0.5mg/mL。考察了常见有机溶剂和麻醉镇静药物的干扰。结论该方法简单、安全、快速,为临床和法庭科学实验室快速筛选GHB和GBL提供了便利。  相似文献   

2.
A simple method of detection was developed for gamma-hydroxybutyrate (GHB). The method involves the derivatization of GHB using a hexyl-chloroformate procedure in aqueous media (such as water or urine), extraction of the derivatization product directly from the sample using solid-phase microextraction, and subsequent separation and detection with gas chromatography quadrupole ion trap mass spectrometry. The deuterated form of GHB (GHB-D6) is used as an internal standard for quantitation. The method was linear for GHB-spiked pure water samples from 2 to 150 microg/mL GHB with a detection limit of 0.2 microg/mL. Spiked urine samples showed linearity from 5 to 500 microg/mL GHB with a detection limit of 2 microg/mL. The SPME-GC/MS method is applied to actual case samples, and the results are compared to those values obtained using a conventional GC/MS method. Sensitivity and linearity are comparable to those seen using traditional methods of separation, yet the SPME method is superior due to the simplicity, speed of analysis, reduction in solvent waste, and ability to differentiate between GHB and gamma-butyrolactone (GBL).  相似文献   

3.
Abstract: A new screening method for detecting gamma-hydroxybutyric acid (GHB) in drink matrices, using the IonSense, Inc. (Saugus, MA) direct analysis in real time (DART) ion source coupled to a JEOL exact mass time-of-flight mass spectrometer (AccuTOF), was validated and compared with the current screening methodology. The DART ion source allows for analysis of samples under ambient conditions with little to no sample preparation. Fifty drink specimens were spiked at levels of 1, 2, 3, and 4 mg/mL GHB, and analyzed on the AccuTOF-DART. Positive detection of GHB occurred for each of the samples at each concentration level, giving 100% accuracy for the samples tested. Twenty-five of the 50 drink specimens were spiked at 1 mg/mL GHB and tested using a color test known as the GHB Color Test #3. Only two of these 25 specimens tested positive for the presence of GHB, giving only 8% accuracy. Implementation of this new methodology as a screening tool for GHB analysis will quickly eliminate negative specimens allowing the examiner to focus analysis time on those that screened positive.  相似文献   

4.
A 1H nuclear magnetic resonance (1H NMR) method for the determination of gamma-hydroxybutyric acid (GHB) and gamma-hydroxybutyrolactone (GBL) in human serum and urine using spiked samples has been developed. The method gives linear responses (correlation coefficients of 0.99 or greater) over the concentration range 0.01 mg/mL to 4.0 mg/mL in urine and 0.3 mg/mL to 2.0 mg/mL in serum. No sample pretreatment is required. Studies of the chemical interconversion of GBL and GHB showed hydrolysis of GBL to be rapid at pH 11.54, slower and less complete (30% hydrolysis) at pH 2.54 and slowest at pH 7.0, reaching 30% hydrolysis in about 40 days. No esterification of GHB was observed at any pH.  相似文献   

5.
A new microcrystal test for the detection of gamma-hydroxybutyrate (GHB) is described. The silver/copper reagent consists of an aqueous solution of 0.1 g of cupric nitrate and 0.1 g of silver nitrate in 10.0 mL water. While some crystals form upon evaporation of the reagent, the test forms distinctive crystals for GHB and does not form crystals with some commonly encountered controlled substances. The reagent was also tested against some controlled substances that have similar biological activity to GHB, including flunitrazepam, and some barbiturates. No crystals were observed with these compounds. A blind test was performed to determine if GHB could be discriminated from the other compounds. Two of ten unknowns were correctly identified as GHB--one solid, one liquid. One GHB sample was not identified as GHB and the remaining seven non-GHB samples were not identified as GHB. The reagent is therefore selective for GHB, but not extremely sensitive.  相似文献   

6.
An enhancement of the microcrystalline test for the detection of gamma-hydroxybutyrate (GHB) is described. The original test used a silver/copper reagent which consisted of 0.1 g of silver nitrate and 0.1 g of copper nitrate in 10 mL water. The enhanced test utilizes lanthanum nitrate in place of copper nitrate. A detection limit of 0.5 mg/mL was achieved and the visual discrimination was improved because of larger sized crystals. Transient crystals were observed between 0.1 and 0.4 mg/mL. Silver nitrate alone appeared to be suitable for GHB detection but was not specific as other hydroxyl acids, such as glycolic acid, produced a similar crystal pattern. Tests conducted on chemical precursors of GHB and substances with similar biological activity highlight the specificity of the enhanced test. The reagent is therefore selective and sensitive for GHB in aqueous solutions. However, in beverage testing, crystal formation appeared to be inhibited for some drinks. Citric acid was identified as a possible interference depending on its concentration relative to GHB.  相似文献   

7.
A rapid colorimetric test for the detection of gamma-hydroxybutyric acid (GHB) is described. The ferric hydroxamate test for ester detection has been adapted to detect GHB in human urine samples from a healthy female and a healthy male subject. The assay can be performed within 5 min and with a GHB detection limit of 0.5 mg/ml when 0.3 ml of human urine is used and a GHB detection limit of 0.1 mg/ml when 1 ml of human urine is used. The colored complex indicating the presence of GHB is purple according to the assay conditions. Test results are free from the interference by alcohol, phenolic compounds and other biological chemicals under the assay conditions. In addition, the colorimetric test is free from the potential false-positive test result that could result from physiological concentrations of GHB.  相似文献   

8.
Liu W  Shen M  Xiang P  Bu J  Wu HJ 《法医学杂志》2007,23(2):120-2, 129
OBJECTIVE: To establish an analytical method for the determination of GHB in beverages using GC/MS and LC/MS/MS. METHODS: After beverage samples with GHB-d6 as the internal standard were extracted with ethyl acetate, then the extracts were derivatized with N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA), at last the derivateized extracts analyzed by gas chromatography- mass spectrometry. After beverage samples with GHB-d6 as the internal standard were diluted by mobile phase then directly analyzed by LC/MS/MS. Results The limit of detection was 0.2 microg/mL and both relative standard deviations for between-day and within-day assays were < 8.54% in GC/MS. The limit of detection was 2 microg/mL and both relative standard deviations for between-day and within-day assays were <8.62% in LC/MS/MS. Conclusion These methods of qualitative and quantitative analysis were found to be sensitive, accurate, rapid and suitable for the forensic toxicology to test of GHB in real cases.  相似文献   

9.
Gamma-hydroxybutyric acid (GHB) can cause problems in interpretation of toxicological findings due to its endogenous nature, significant production in tissues after death and potential formation in stored samples. Our study was designed to determine the influence of storage conditions on GHB levels and its possible in vitro formation in blood and urine in cases where no exogenous use of GHB or its precursors was suspected. The samples were prepared by validated method based on liquid-liquid reextraction with adipic acid internal standard and MSTFA derivatization and assayed on a GC-MS operating in EI SIM mode. The first part of the study was performed with pooled blood and urine samples obtained from living and deceased subjects stored with and without NaF (1% w/v) at 4 and -20 degrees C over 8 months. In ante-mortem samples (both blood and urine) no significant GHB production was found. After 4 months of storage, the substantial GHB rise up to 100 mg/Lwas observed in post-mortem blood stored at 4 degrees C without NaF with subsequent gradual decrease in following months. The inhibition of GHB production was apparent during storage in NaF treated frozen blood samples. In post-mortem urine only slight temporary GHB levels were ascertained (up to 8 mg/L). The second part of our study was aimed to analyse 20 individual post-mortem blood samples stored at 4 degrees C for 16-27 days between autopsy and analysis without preservation followed by storage at 4 degrees C with NaF for 4 months. The temporary GHB production with maximum of 28 mg/Lwas detected in some samples.  相似文献   

10.
We report a case of fatal intoxication from 1,4‐butanediol (1,4‐BD), which was ingested by a young and “naïve” gamma‐hydroxybutyrate (GHB) consumer during a party with the co‐ingestion of alcohol, cannabis, and methylene‐dioxy‐methamphetamine. The following drug concentrations were found using gas chromatography coupled with mass spectrometry on autopsy samples and on a cup and a glass found at the scene: 20,350 mg/L (bottle) for 1,4‐BD; 1020 mg/L (femoral blood), 3380 mg/L (cardiac blood), 47,280 mg/L (gastric content), and 570 mg/L (vitreous humor) for GHB. The concentration of GHB is difficult to interpret in forensic cases due to the possibility of an endogenous production of GHB. The variable tolerance of the user may also modify the peri‐ and postmortem GHB concentrations. This case underscores the need to have many different sources of toxicology samples analyzed to avoid the hypothesis of endogenous production of GHB.  相似文献   

11.
Abstract:  Gamma-hydroxybutyrate (GHB) is best known as a recreational depressant drug, whose use has also been implicated in drug facilitated sexual assault cases. It is also available as a therapeutic agent (Xyrem®) used for the treatment of daytime sleepiness or cataplexy associated with narcolepsy. This is a report of a case of a 53-year-old woman undergoing treatment with Xyrem® for narcolepsy. The decedent was also prescribed tramadol, gabapentin, cetirizine, modafinil, carisoprodol, and Xyrem®. Toxicological analysis of the blood revealed GHB 165.6 mg/L, and 90.7 mg/L in the urine. Blood GHB concentrations in the range 156–260 mg/L have been reported to induce moderately sound sleep. The combined use of central nervous system depressant drugs, together with her problematic sleep apnea, and snoring (both contraindications for GHB use) were determined to have caused this subject's death. The manner of death was determined to be accidental.  相似文献   

12.
Gamma-hydroxybutyric acid (GHB) and its precursor gamma-butyrolactone (GBL) are regularly implicated in instances of surreptitious drug administration, particularly in beverages (so-called "spiked drinks"). In order to assist in the interpretation of cases where analysis of the actual beverage is required, over 50 beverages purchased in the UK were analysed for the presence of GHB and GBL. It was found that naturally occurring GHB and GBL were detected in those beverages involving the fermentation of white and particularly red grapes. No GHB or GBL was detected in other drinks such as beer, juice, spirits or liqueurs. GHB/GBL was detected in red wine vermouth (8.2 mg/L), sherry (9.7 mg/L), port (GBL), red wine (4.1-21.4 mg/L) and white wine (<3-9.6 mg/L). The presence of GHB/GBL did not appear to be influenced by the alcohol content or the pH of the beverage. In addition, the concentration in wines did not appear to be related to the geographical origin of the grape type. This is believed to be the first published data concerning the endogenous presence of GHB and GBL in the beverages described.  相似文献   

13.
Two hundred and forty-seven serum samples which have been collected by police during roadside testing and have been found positive for amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA) and/or 3,4-methylenedioxyethamphetamine (MDE) were analyzed for gamma-hydroxybutyrate (GHB). Serum samples were spiked with deuterated GHB as internal standard and acetonitrile was added to achieve dilution and protein precipitation. Samples were analyzed with a LC-MS/MS system operated in the multiple reaction monitoring mode (MRM) using a TurboIonSpray source. Chromatographic separation was achieved using a Synergi Polar RP column applying a gradient elution with a runtime of 15 min. To differentiate between endogenous and exogenously administered GHB a cut-off concentration of 10 microg/mL was applied. Five samples exceeded this concentration and were found positive for GHB. These samples were only found positive for amphetamine but no other amphetamine derivatives were detected, while in three samples THC and in one sample cocaine, benzoylecgonine and ethanol were found.  相似文献   

14.
Several assays for gamma-hydroxybutyrate (4-hydroxybutyrate, GHB) have been developed based on the enzyme gamma-hydroxybutyrate dehydrogenase (GHB-DH). Enzymatic oxidation of GHB by NAD+ is coupled to diaphorase-mediated reduction of pro-dye to yield colored product. GHB-DH from Ralstonia eutropha was cloned and expressed as a stable fusion protein easily purified by affinity chromatography. Quantitative initial velocity and endpoint versions of the assay in solution are described. Michaelis-Menten parameters for oxidation of GHB and ethanol were estimated. A semi-quantitative "dipstick" version of the assay on paper also is described. Both solution endpoint and "dipstick" assays are sensitive to about 0.05 mg GHB/mL using 10 microL of sample. Ethanol at concentrations possible in urine and agents used to stabilize physiological fluids for forensics analysis do not interfere significantly. The "dipstick" assay also allows detection of GHB in alcoholic beverages after evaporation of about one-fourth drop of beverage before testing. The enzymatic assay for GHB is reliable, sensitive, inexpensive and rapid.  相似文献   

15.
The endogenous nature of the drug of abuse gamma hydroxybutyric acid (GHB) has caused various interpretative problems for toxicologists. In order to obtain data for the presence of endogenous GHB in humans and to investigate any factors that may affect this, a volunteer study was undertaken. The GHB concentrations in 119 urine specimens from GHB-free subjects and 25 urine specimens submitted for toxicological analysis showed maximal urinary GHB concentrations of 3mg/l. Analysis of 15 plasma specimens submitted for toxicological analysis detected no measurable GHB (less than 2.5mg/l). Studies in a male and female volunteer in which different dietary food groups were ingested at weekly intervals, showed significant creatinine-independent intra-individual fluctuation with overall urine GHB concentrations between 0 and 2.55, and 0 and 2.74mg/l, respectively. Urinary concentrations did not appear to be affected by the particular dietary groups studied.The concentrations measured by gas chromatography with flame ionisation detection (GC-FID) and gas chromatography with mass spectrometry (GC-MS) lend further support to the proposed urinary and plasma interpretative cut-offs of 10 and 4mg/l, respectively, where below this it is not possible to determine whether any GHB detected is endogenous or exogenous in nature.  相似文献   

16.
The in vitro production of GHB was observed in freshly collected, untreated whole blood samples using glass BD-Vacutainers and polypropylene S-monovettes. GHB concentrations were determined daily over a period of one week and after 3, 6 and 9 weeks again. Furthermore, the GHB concentration in 40 untreated random whole blood samples stored at 4°C for a longer period of time (10 samples 12 month, 10 samples 24 month and 20 samples 36 month) was also determined. For comparison, the in vitro production of GHB in freshly collected and prepared serum samples was observed. GHB serum concentrations were determined three times over a period of one week and once again after six weeks. Sample preparation was performed by means of methanolic extraction following the precipitation of whole blood and serum samples. A methanolic standard calibration was done in a low range of 0.005-0.1 μg/mL (LOD: 0.004, LLOQ: 0.013). For quantification a spiked blood bank serum with a determined GHB concentration of 0.09 μg/mL was used. Corrected calibrations in the range of 0.09-5.09 μg/mL were used (LOD: 0.08 μg/mL, LLOQ: 0.30 μg/mL), recovery: 91.3% (high level: 4.09 μg/mL) 50.5% (low level: 0.19 μg/mL). RESULTS: Relevant elevation of GHB was observed in all whole blood samples stored in liquid form (4°C or room temperature). In two of the 40 whole blood samples stored over a longer period of time at 4°C, GHB concentrations in the range of 13 μg/mL were even determined. These findings constitute grounds for caution. Even a GHB cut-off level of 5 μg/mL cannot be considered as "absolutely positive" proof of a case of exogenous administration, at least in untreated liquid blood samples in long time storage. However, no significant elevations of GHB were otherwise observed in any of the serum samples independently of storage temperature nor in the whole blood samples that were frozen for storage. CONCLUSIONS: The results suggest that the cut-off for exogenous GHB of 5 μg/mL could be lowered significantly, with the consequence of winning valuable time for the potential victim, but only if serum is collected for GHB determination or if the whole blood sample is frozen immediately after collection and the procedure well documented.  相似文献   

17.
Gamma-hydroxybutyric acid's (GHB's) natural presence in the body has made the interpretation of its levels a challenging task for the forensic toxicologist. This study was designed to measure endogenous GHB levels in antemortem urine and blood samples. The range detected in urine was from 34 to 575 microg/dl and in blood from 17 to 151microg/dl. The results indicate that the concentration of endogenous GHB in urine and blood concur with the suggested cut-off levels at 1000 and 500 microg/dl, respectively.  相似文献   

18.
In forensic evidence, gamma-hydroxybutyric acid (GHB) has frequently been encountered in one of its salt forms (gamma-hydroxybutyrate), but has also been encountered in its free acid form (GHB). Owing to the physical properties, encounters of the free acid have been largely restricted to forensic exhibits comprising aqueous solutions, such as acidic beverages that have been "spiked" or formulated with GHB salts or gamma-butyrolactone (GBL). The analysis of GHB free acid presents particular difficulties including the potential for altering the original proportions of GHB free acid, GHB carboxylate, and GBL in the course of analysis, and discrimination between GHB free acid and carboxylate forms. In this work, the formation of GHB free acid in aqueous solutions (water and/or D2O) was studied as a function of solution pH. Proton nuclear magnetic resonance (1HNMR) and Fourier-transform infrared spectrometry (FT-IR) measurements were obtained on freshly prepared mixtures of NaGHB and HCl stock solutions representing a series of points along the GHB titration curve. Both 1HNMR and FT-IR were shown to track the changing proportions of GHB free acid and carboxylate forms as a function of pH, while simultaneously monitoring for the formation of the lactone (GBL). The results were consistent with acid-base conversion behavior for a carboxylic acid. 1HNMR was shown to provide an ideal means for analysis of aqueous-based GHB/GBL forensic exhibits based on simple dilution of the neat liquid exhibit, without altering the original proportions of GHB free acid, carboxylate, and GBL in the samples.  相似文献   

19.
In this work, the interconversion of GHB and GBL in a variety of aqueous media was studied. The effects of solution pH and time were determined by spiking GHB or GBL into pure water and buffered aqueous solutions, and determining the GHB and GBL contents at various time intervals. The degree of GBL hydrolysis to GHB was determined for several commercial aqueous-based GBL products, and further studied as a function of time. The effects of temperature and time were also determined for five commercial beverages spiked with GHB or GBL. GHB and GBL contents were determined using high performance liquid chromatography (HPLC). GHB and/or GBL confirmations were made using gas chromatography-mass spectrometry (GC-MS) and/or infrared spectroscopy (IR). Solution pH, time, and storage temperature were determined to be important factors affecting the rate and extent of GBL hydrolysis to GHB. Under strongly alkaline conditions (pH 12.0), GBL was completely converted to GHB within minutes. In pure water, GBL reacted to form an equilibrium mixture comprising ca. 2:1 GBL:GHB over a period of months. This same equilibrium mixture was established from either GHB or GBL in strongly acidic solution (pH 2.0) within days. A substantial portion of GBL (ca. 1/3) was hydrolyzed to GHB in aqueous-based GBL products, and in spiked commercial beverages, after ambient storage for a period ranging from several weeks to several months. Heat increased and refrigeration decreased the rate of GBL hydrolysis relative to ambient conditions. These studies show that hydrolysis of GBL to GHB does occur in aqueous-based solutions, with samples and time frames that are relevant to forensic testing. Implications for forensic testing and recommendations are discussed.  相似文献   

20.
There is no toxicological analysis of gamma-hydroxybutyrate (GHB) applied routinely in cases of driving under influence (DUI); therefore the extent of consumption of this drug might be underestimated. Its consumption is described as occurring often concurrently with amphetamine or ecstasy. This study examines 196 serum samples which were collected by police during road side testing for GHB. The samples subject to this study have already been found to be positive for amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA) and/or 3,4-methylenedioxyethamphetamine (MDEA). Analysis has been performed by LC/MS/MS in the multiple reaction monitoring (MRM) mode. Due to its polarity, chromatographic separation of GHB was achieved by a HILIC column. To differentiate endogenous and exogenous levels of GHB, a cut-off concentration of 4μg/ml was applied. Of the 196 samples, two have been found to be positive for GHB. Of these samples, one sample was also positive for amphetamine and one for MDMA. Whilst other amphetamine derivates were not detected in these samples, both samples were found to be positive for cannabinoids. These results suggest that co-consumption of GHB with amphetamine or ecstasy is relatively low (1%) for the collective of this study.  相似文献   