首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In addition to having blast mitigation properties, aqueous foam concentrate AFC-380 blast suppression foam is designed to capture aerosolized chemical, biological, and radioactive particles during render-safe procedures of explosive devices. Exposure to aqueous environments and surfactants may negatively affect forensic evidence found at the scene, but the effects of AFC-380 foam and aqueous gel on the preservation and subsequent analysis of forensic evidence have not previously been investigated. Sebaceous finger and palm prints and DNA samples on paper, cardboard, tape, and various metal and plastic items, along with hairs, carpet and yarn fibers, and inks and documents, were exposed to AFC-380 foam. Similar mock evidence was also exposed to a superabsorbent gel of the type found in aqueous gel blocks used for shrapnel containment. Exposure to foam or aqueous gel was associated with a dilution effect for recovered DNA samples, but quality of the samples was not substantially affected. In contrast, exposure to AFC-380 foam or gel was detrimental to development of latent finger and palm prints on any substrate. Neither the hair nor the fiber samples were affected by exposure to either the foam or gel. Indented writing on the document samples was detrimentally affected by foam or gel exposure, but not inks and toners. The results from this study indicate that most types of forensic evidence recovered after being exposed to aqueous gel or blast suppression foam can be reliably analyzed, but latent finger and palm prints may be adversely affected.  相似文献   

2.
文检仪显现同种同色掩盖字迹条件的初探   总被引:1,自引:0,他引:1  
目的研究运用文检仪显现同种同色掩盖字迹的显出条件。方法以黑色签字笔为例,依据不同型号笔的油墨在不同光源下的荧光性质和红外吸收能力的差异,利用文检仪进行分析检验。结果只有在一定条件下被掩盖字迹才能被显出。结论在LUMI=IR红外荧光(兰光)下,只能显现激发荧光的油墨掩盖不能激发荧光的油墨的字迹和激发荧光能力弱的油墨掩盖激发荧光能力强的油墨的字迹;在红外吸收光和365nm长波紫外表面光下,只能显现颜色浅的油墨掩盖颜色深的油墨的字迹。  相似文献   

3.
A new type of erasable gel pen ink is becoming increasingly popular because of the modifiable characteristics for writing on documents. This study attempts to distinguish 12 types of blue and black erasable gel pens produced by mainstream stationery manufacturers using infrared (IR) visual analysis, Fourier transform infrared (FTIR) analysis, fluorescence analysis, and microspectrophotometry. The results demonstrate that IR visual, FTIR, and fluorescence analysis can be used to help distinguish each type of erasable gel ink. While microspectrophotometry can be used to effectively differentiate the blue gel inks in this study, there are limitations with respect to distinguishing black erasable gel pens. When these four optical analyses methods were used in combination, the gel inks could be accurately distinguished.  相似文献   

4.
In this study, the potential of attenuated total reflectance-Fourier transform infrared (ATR-FTIR) spectral imaging as a technique to determine the sequence of line crossings was examined. The technique was successful in determining the sequence of heterogeneous line intersections produced using ballpoint pens and laser printers. By imaging at characteristic frequencies, it was possible to form spectral images showing the spatial distribution of the materials. By examining the spectral images from the inks, it was possible to determine whether the ink was above or below the toner. In blind testing, ATR-FTIR spectral imaging results were directly compared to those obtained by eight experienced forensic document examiners using methods regularly employed in casework. ATR-FTIR spectral imaging was shown to achieve a 100% success rate in the blind tests, whereas some incorrect sequence determinations were made by the forensic document examiners when using traditional techniques. The technique was unable to image ink-jet printing, gel pens, roller ball pens, and felt-tip pens, and was also unable to determine the sequence of intersecting ballpoint pen lines.  相似文献   

5.
Utilizing a database of standards for forensic casework is a valuable resource. Undoubtedly, as more standards (and corresponding information about the specimens) are collected, there is a greater certainty of identification when a questioned and a known item cannot be distinguished after a series of analyses. The United States Secret Service and the Internal Revenue Service National Forensic Laboratory jointly maintain the largest known forensic collection of writing inks in the world, which is comprised of over 8500 ink standards collected worldwide, dating back to the 1920s. This study was conducted to evaluate the reliability of matching arbitrarily purchased pens with known inks from a database. One hundred pens were randomly obtained from a variety of sources and their respective ink compositions were compared with standards. Eighty-five of the inks were determined to be suitable for comparison utilizing optical examinations and thin-layer chromatography. Three of the inks did not match any of the specimens on record; one of these inks was similar to an ink from an identical brand of pen that was in the database, but had a modified formulation.  相似文献   

6.
Bloodstain evidence is a highly valued form of physical evidence commonly found at scenes involving violent crimes. However, painting over bloodstains will often conceal this type of evidence. There is limited research in the scientific literature that describes methods of detecting painted-over bloodstains. This project employed a modified digital single-lens reflex camera to investigate the effectiveness of infrared (IR) photography in detecting latent bloodstain evidence beneath a layer or multiple layers of paint. A qualitative evaluation was completed by comparing images taken of a series of samples using both IR and standard (visible light) photography. Further quantitative image analysis was used to verify the findings. Results from this project indicate that bloodstain evidence can be detected beneath up to six layers of paint using reflected IR; however, the results vary depending on the characteristics of the paint. This technique provides crime scene specialists with a new field method to assist in locating, visualizing, and documenting painted-over bloodstain evidence.  相似文献   

7.
Inks from seven black and eight blue ballpoint pens were separated by a high-performance liquid chromatography (HPLC) method utilizing a photodiode array detection (PDA). A classifier flowchart was designed for the chromatographic data based on the presence or absence of certain peaks at different wavelengths to qualitatively discriminate between the inks. The same data were quantitatively classified by principal components analysis (PCA) to estimate the separation between a pair of classes of ink samples. It was found that the black ballpoint pen inks were discriminated satisfactorily utilizing two-dimensional data of the peak areas and retention times at the optimum wavelengths. The blue pens were discriminated by analyzing the chromatographic data at four different wavelengths simultaneously with a cross-validated PCA. The results of this study indicated that HPLC-PDA coupled with chemometrics could make a powerful discriminating tool for the forensic chemist, especially when analyzing extensive and/or complex data.  相似文献   

8.
The aim of this project was to investigate the evidential value of blue and black ballpoint pen inks in Australia. For this purpose, 49 blue and 42 black ballpoint pen inks, of different brands, models and batches, representative of those ballpoint pens available on the Australian market at the time of the study, were analysed by three techniques: filtered light examination (FLE); reflectance visible microspectrophotometry (MSP); and thin-layer chromatography (TLC). The results showed that the power of the individual techniques to discriminate inks between and within brands, models and batches varied, the most informative techniques being TLC>FLE>MSP. The greatest degree of differentiation was achieved when using a combined sequence of techniques, the discriminating power being 0.99 and close to 1 for blue and black inks, respectively (different brands and models). In respect to the discrimination between different batches of a same brand and model, it was shown that 14 out of the 33 pairs compared could be discriminated. Overall, this study confirmed the high value of the examination of inks when applied to ballpoint pens available in Australia, especially when a combined sequence of techniques is applied.  相似文献   

9.
目的考察在运用拉曼光谱阵列面扫描检验朱墨时序的方法中书写笔油墨种类对检验结果的影响。方法根据拉曼谱图的不同对搜集的188种书写笔(包括22种黑色圆珠笔,62种蓝色圆珠笔,62种黑色签字笔,42种蓝色签字笔)进行扫描并分类,采用拉曼光谱阵列面扫描技术对书写笔与同一印泥和印油形成的朱墨时序样本进行检验。结果 188种书写笔被分为4大类23小类,4类书写笔与印泥或印油形成的朱墨时序样本都得到了较好的检验结果。结论在本实验条件下,书写笔油墨种类对拉曼光谱阵列面扫描检验朱墨时序的检验结果没有影响。  相似文献   

10.
An imaging technique that is capable of reducing glare, reflection, and shadows can greatly assist the process of toolmarks comparison. In this work, a camera with near‐infrared (near‐IR) photographic capabilities was fitted with an IR filter, mounted to a stereomicroscope, and used to capture images of toolmarks on fired bullets and cartridge cases. Fluorescent, white light‐emitting diode (LED), and halogen light sources were compared for use with the camera. Test‐fired bullets and cartridge cases from different makes and models of firearms were photographed under either near‐IR or visible light. With visual comparisons, near‐IR images and visible light images were comparable. The use of near‐IR photography did not reveal more details and could not effectively eliminate reflections and glare associated with visible light photography. Near‐IR photography showed little advantages in manual examination of fired evidence when it was compared with visible light (regular) photography.  相似文献   

11.
The work described in this report was focused on generating increased knowledge of fingerprint chemistry, particularly the composition of a latent fingerprint at the time it is deposited, and the chemical changes in lipid components that occur over time. Fingerprints from five male donors (aged 25-34 years) were collected and aged under controlled conditions. The prints were then sampled at set intervals, solvent extracted with dichloromethane, co-derivatized with MSTFA and analyzed by gas chromatography-mass spectrometry (GC-MS). It was shown that there was loss of squalene from prints stored in the light or in the dark. Loss was more rapid in the light, with squalene in prints from some donors not detected after 9 days storage. For these same donors, squalene was still detected after 33 days storage in the dark, but at much lower levels than in fresh prints. For saturated fatty acids (tetradecanoic, palmitic and stearic acid) there was a trend towards an increase in levels of these substances during storage (up to about 20 days) followed by a decrease back to original levels or below. This was the case for samples stored in the light or in the dark. For palmitoleic acid, a similar trend was seen. For oleic acid, this trend was seen for samples stored in the dark. For samples stored in the light the general trend was a decrease in level over the storage period (up to 33 days).  相似文献   

12.
Usually, the differentiation of inks on questioned documents is carried out by optical methods and thin layer chromatography (TLC). Therefore, spectrometric methods were also proposed in forensic literature for the analysis of dyes. Between these techniques, laser desorption/ionization mass spectrometry (LDI-MS) has demonstrated a great versatility thanks to its sensitivity to blue ballpoint ink dyes and minimal sample destruction. Previous researches concentrated mostly on the LDI-MS positive mode and have shown that this analytical tool offers higher discrimination power than high performance TLC (HPTLC) for the differentiation of blue ballpoint inks. Although LDI-MS negative mode has already been applied in numerous forensic domains like the studies of works of art, automotive paints or rollerball pens, its potential for the discrimination of ballpoint pens was never studied before. The aim of the present paper is therefore to evaluate its potential for the discrimination of blue ballpoint inks. After optimization of the method, ink entries from 33 blue ballpoint pens were analyzed directly on paper in both positive and negative modes by LDI-MS. Several cationic and anionic ink components were identified in inks; therefore, pens were classified and compared according to their formulations. Results show that additional information provided by anionic dyes and pigments significantly increases the discrimination power of positive mode. In fact, it was demonstrated that classifications obtained by the two modes were, to some extent, complementary (i.e., inks with specific cationic dyes not necessarily contained the same anionic components).  相似文献   

13.
Pigments are rapidly replacing dyes as colorants in pen and printer inks, due to their superior colors and stability. Unfortunately, tools commonly used in questioned document examination for analyzing pen inks, such as TLC, cannot be used for the analysis of insoluble pigments on paper. Laser desorption mass spectrometry is demonstrated here as a tool for analyzing pigment-based pen inks. A pulsed nitrogen laser can be focused onto a pen stroke from a pigmented ink pen on paper, and positive and negative ions representative of the pigment can be generated for subsequent mass spectrometric analysis. Targeted pens for this work were a set of Uni-ball 207 pigmented ink pens containing blue, light blue, orange, green, violet, red, pink, and black inks. Copper phthalocyanine was identified as the pigment used to make both blue inks. A mixture of halogenated copper phthalocyanines were identified in the green ink. Unexpectedly, the pink ink was found to contain a red pigment, Pigment Red 12, treated with a mixture of water-soluble dyes. Each sample yielded ions representative of the pigments present.  相似文献   

14.
Forensic investigators frequently utilise light sources to detect and presumptively identify biological evidence. The instrumentation typically deploys single or multiple wavelength exposures at various intensities, which interact with constituents of biological material, initiating fluorescence or improving contrast between the material and substrate. Documentation using sketches and/or photographic approaches follows detection, which are essential for scene reconstruction. Recent research has demonstrated the simultaneous detection and capture of biological evidence using a 360° camera system combined with an alternate light source exhibiting broad wavelength ranges of light. Single wavelength light sources reportedly offer enhanced sensitivity, due to the increased light intensity and narrower bandwidth of light, although their combined use with a 360° camera system has not yet been explored.Samples of human blood, semen, saliva, and latent fingermarks were deposited on to a variety of substrates. A 360° camera system combined with a laser light source was used to detect and capture the samples. Ten participants were asked to detect the samples on images of the substrates without ground truth knowledge. It was possible to detect and capture biological evidence, although success varied according to substrate colour and light intensity. Advantageously, presumptive screening for biological fluids and the simultaneous location and visualisation of such evidence as part of a 360° panorama of the scene for contextual purposes was permitted. There was no fluorescent response from the fingermarks, although the oblique lighting effects appeared sufficient to aid mark detection in some circumstances. The use of single wavelength illumination clearly facilitates identification of a range of forensically important material. When coupled with a 360-degree camera, this allows for simultaneous identification and recording of such evidence in the context of the whole environment.  相似文献   

15.
Gel ink pens have become a common writing instrument in the United States. Questioned document examiners often attempt to optically differentiate gel inks from each other and from other non-ballpoint ink writings (e.g., those from roller-ball pens). Since early formulations were primarily pigment-based, they do not elute when analyzed by thin-layer chromatography. However, recent gel ink formulations (i.e., within the past five years) include dye-based inks that can be easily separated. This study differentiates black gel inks using optical and chemical techniques. The techniques include: microscopy, visible and near infrared reflectance, near infrared luminescence, thin-layer chromatography (TLC), spot tests, and gas chromatography/mass spectrometry (GC/MS). As a result of this study a flow chart has been developed allowing for a systematic determination of a questioned ink. In addition, an analysis of volatile compounds found in gel inks revealed that there are some unique ingredients that may be found in gel inks that are not typically found in other non-ballpoint inks.  相似文献   

16.
In this paper, we use bloodstains to illustrate an approach for identifying latent evidence on dark cloth using near infrared (NIR) photography combined with high dynamic range (HDR) photography techniques. NIR photography alone has been used to capture latent evidence that cannot be seen in normal ambient light. HDR techniques combine multiple bracketed photographs of the same image to increase the dynamic range of the photograph which can provide greater contrast. Using NIR photography alone, we were able to detect a bloodstain up to a 1/16 dilution, an improvement over previous studies. Combining NIR photography with the HDR process resulted in a noticeable increase in visibility up to 1/16 dilution when compared to NIR photographs alone. At 1/32 dilution, we were able to detect bloodstains that were not visible using NIR alone. NIR is a useful tool for imaging latent evidence, and combining NIR with HDR consistently provides better results over NIR alone.  相似文献   

17.
Evidence materials in a presumed suicide case were studied by a firearm examiner and a forensic chemist. The victim's body with double gunshot wounding in his forehead, a machine gun in the sustained fire mode with a silencer, and four cartridge cases were found. Examinations of the evidence, the case file studies, and experiments dedicated to the case were carried out. Relationships between the placement of cartridge cases and the gun were established using a fast camera. The distributions of gunshot residues on the evidence materials and within the comparative gunshot patterns were studied by means of optical and electron microscopy, X‐ray microanalysis, and infrared spectroscopy. The shooting distance was assessed to be 30 cm or more, whereas the greatest distance that could have been achieved by the victim himself was about 11–13 cm. The obtained results supported the version of homicide rather than suicide.  相似文献   

18.
茚三酮是显现渗透性客体上潜在汗液手印的最常用方法之一,采用微量物证提取纸和茚三酮溶液有机结合制作的茚三酮固体介质可以有效避免客体表面背景着色,不容易引起纸张油墨扩散,另外避免使用的溶剂易燃。能够更便捷的显现现场指纹,并且能够突破茚三酮只能显现渗透性客体的局限,拓宽茚三酮显现客体的范围,在热敏纸上潜指纹的显现方面有独特的应用优势。  相似文献   

19.
This paper demonstrates a novel and simple technique for the diagnosis of death by fire using a digital infrared (IR) camera system. At autopsy, the inhalation of soot by a fire victim is a definite indicator proving a vital reaction during the fire. However, there can be difficulties in confirming the presence of soot because of the relative lack of soot or the similarity in color between soot and surrounding tissues. To evaluate the effectiveness of IR imaging at autopsy, we acquired internal images of the respiratory and gastrointestinal system by both an ordinary color and IR cameras. Using our method, the inhaled soot is visible as black particles or deposits, while the blood is transparent and the surrounding tissue is whitened. This technique enables the detection of normally undiscriminating soot in an ordinary color image. This is the first report suggesting the usefulness of IR imaging in forensic autopsy for the diagnosis of death by fire.  相似文献   

20.
Abstract: Criminal acts such as an attack utilizing a radiological dispersal device (RDD or dirty bomb), the manufacture of such a device, or the illicit trafficking of radioactive materials would warrant a criminal investigation. This could involve the collection, transportation, and analysis of radiologically contaminated trace evidence. But are law enforcement agencies and forensic scientists capable of dealing with this? This research investigates the decontamination efficacy of two decontamination techniques (chemical and physical) designed for the removal of radiological material from documents of forensic importance. The impact that these procedures have on the development of latent fingermarks and the forensic analysis of the inks on these documents is also studied. It was found that slight changes in the color and chemical composition of a variety of document inks and a destruction of fingermark ridges occurred after chemical decontamination. Physical decontamination had no impact on these parameters.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号