首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A fully validated, sensitive and specific method for the extraction and quantification of Delta(9)-tetrahydrocannabinol (THC) and 11-nor-9-carboxy-Delta(9)-THC (THC-COOH) and for the detection of 11-hydroxy-Delta(9)-THC (11-OH THC) in oral fluid, urine and whole blood is presented. Solid-phase extraction and liquid chromatography-mass spectrometry (LC-MS) technique were used, with electrospray ionization. Three ions were monitored for THC and THC-COOH and two for 11-OH THC. The compounds were quantified by selected ion recording of m/z 315.31, 329.18 and 343.16 for THC, 11-OH THC and THC-COOH, respectively, and m/z 318.27 and 346.26 for the deuterated internal standards, THC-d(3) and THC-COOH-d(3), respectively. The method proved to be precise for THC and THC-COOH both in terms of intra-day and inter-day analysis, with intra-day coefficients of variation (CV) less than 6.3, 6.6 and 6.5% for THC in saliva, urine and blood, respectively, and 6.8 and 7.7% for THC-COOH in urine and blood, respectively. Day-to-day CVs were less than 3.5, 4.9 and 11.3% for THC in saliva, urine and blood, respectively, and 6.2 and 6.4% for THC-COOH in urine and blood, respectively. Limits of detection (LOD) were 2 ng/mL for THC in oral fluid and 0.5 ng/mL for THC and THC-COOH and 20 ng/mL for 11-OH THC, in urine and blood. Calibration curves showed a linear relationship for THC and THC-COOH in all samples (r(2)>0.999) within the range investigated. The procedure presented here has high specificity, selectivity and sensitivity. It can be regarded as an alternative method to GC-MS for the confirmation of positive immunoassay test results, and can be used as a suitable analytical tool for the quantification of THC and THC-COOH in oral fluid, urine and/or blood samples.  相似文献   

2.
Oral fluid (collected with the Intercept((R)) device) and plasma samples were obtained from 139 individuals suspected of driving under the influence of drugs and analyzed for Delta(9)-tetrahydrocannabinol (THC), the major psychoactive constituent of cannabis, using a validated quantitative LC-MS-MS method. The first aim of the study was to investigate the correlation between the analytical data obtained in the plasma and oral fluid samples, to evaluate the use of oral fluid as a 'predictor' of actual cannabis influence. The results of the study indicated a good accuracy when comparing THC detection in oral fluid and plasma (84.9-95.7% depending on the cut-off used for plasma analysis). ROC curve analysis was subsequently used to determine the optimal cut-off value for THC in oral fluid with plasma as reference sample, in order to 'predict' a positive plasma result for THC. When using the LOQ of the method for plasma (0.5 ng/mL), the optimal cut-off was 1.2 ng/mL THC in oral fluid (sensitivity, 94.7%; specificity, 92.0%). When using the legal cut-off in Belgium for driving under the influence in plasma (2 ng/mL), an optimal cut-off value of 5.2 ng/mL THC in oral fluid (sensitivity, 91.6%; specificity, 88.6%) was observed. In the second part of the study, the performance of the on-site Dr?ger DrugTest for the screening of THC in oral fluid during roadside controls was assessed by comparison with the corresponding LC-MS-MS results in plasma and oral fluid. Since the accuracy was always less than 66%, we do not recommend this Dr?ger DrugTest system for the on-site screening of THC in oral fluid.  相似文献   

3.
目的建立一种尿液中9种苯二氮?类药物的超分子溶剂样品气相色谱-串联质谱(gas chromatography-tandem mass spectrometry,GC-MS/MS)分析方法。方法含9种苯二氮?类药物对照品的尿液样品用四氢呋喃和1-己醇组成的超分子溶剂进行液液萃取,取溶剂层氮吹至干,残余物用甲醇复溶后进行GC-MS/MS分析,数据采集方式为多反应监测模式,采用内标法定量。结果尿液中地西泮、咪达唑仑、氟硝西泮和氯氮平质量浓度在1~100ng/mL,劳拉西泮和阿普唑仑质量浓度在5~100ng/mL,硝西泮和氯硝西泮质量浓度在2~100ng/mL,艾司唑仑在质量浓度0.2~100ng/mL范围内具有良好的线性关系,相关系数为0.9991~0.9999,定量下限为0.2~5ng/mL,提取回收率为81.12%~99.52%,日内精密度[相对标准偏差(relative standard deviation,RSD)]和准确度(偏倚)分别小于9.86%、9.51%;日间精密度(RSD)和准确度(偏倚)分别小于8.74%、9.98%。室温和-20℃条件下,尿液中9种药物在15d内具有良好的稳定性。8名志愿者单摄口服阿普唑仑片后,在8~72h内尿液中阿普唑仑的质量浓度为6.54~88.28ng/mL。结论本研究建立的尿液中9种苯二氮?类药物的超分子溶剂萃取-GC-MS/MS分析方法,简便、快速、准确、灵敏,可为临床治疗及司法鉴定中苯二氮?类药物中毒监测提供技术支持。  相似文献   

4.
The purpose of this study was to determine the performance characteristics of the Cozart Amphetamine Microplate EIA for detecting amphetamine in oral fluid. Oral fluid samples were collected using the Cozart RapiScan Collection System from 135 volunteer donors from drug treatment clinics. A further 35 oral fluid samples were collected from volunteer donors who were not drug users. The samples were analyzed in the laboratory using the Cozart Amphetamine Microplate EIA and confirmed using gas chromatography-mass spectrometry (GC-MS). The samples were stored frozen until analysis by GC-MS. The intra-assay precision for the Cozart Amphetamine Microplate EIA for amphetamine in oral fluid over forty assays was 2.74-7.1% CV (within assay) and 3.4-7.0% CV (within day). A total of 78 samples were positive for various amphetamines and related designer drugs. The Cozart Amphetamine Microplate EIA, using a cutoff of 45 ng/ml amphetamine equivalents in neat oral fluid, had a sensitivity of 91.7+/-3.3% and a specificity of 95.9+/-1.9% versus GC-MS using a cutoff of 30 ng/ml. A series of potential adulterants of oral fluid were evaluated and shown not to alter the outcome of the test result.  相似文献   

5.
The purpose of these studies was to evaluate the performance characteristics of the Cozart Microplate Enzyme Immunoassay (EIA) for the determination of methadone in oral fluid from patients in a drug misuse treatment program. Oral fluid specimens were collected using the Cozart RapiScan Collection system from 198 donors who were receiving treatment for their addiction and were monitored for drug misuse. Oral fluid specimens were also collected from forty volunteer donors who were not drug users. The specimens were analyzed in the laboratory by EIA and then analysed for methadone and its main metabolite EDDP by gas chromatography-mass spectrometry (GC-MS). A total of 103 samples were confirmed positive for methadone. The Cozart Microplate EIA for d-Methadone in oral fluid using a cutoff of 30 ng/mL in diluted oral fluid had a sensitivity of 91.3% +/- 2.8% and a specificity of 100% +/- 1.0% vs. GC-MS.  相似文献   

6.
目的建立203种毒品的液相色谱-串联质谱筛查鉴定方法。方法选用Accucore TM Phenyl/Hexyl苯基己基柱(100 mm×2.1 mm,2.6μm)为色谱柱,柱温50℃,以甲醇乙腈混合溶剂(体积比1:1,含0.1%甲酸和2 mmol/L甲酸铵)、水(含0.1%甲酸和2 mmol/L甲酸铵)作为流动相进行梯度洗脱,流速0.4 mL/min。质谱采用电喷雾正离子模式(ESI+)进行离子化,使用多反应监测(MRM)模式采集数据,总分析时间14 min。结果该方法实现了203种毒品的筛查鉴定分析,各目标物的方法检出限均为10 ng/mL。结论建立的筛查鉴定方法具有快速、准确、灵敏等优点,能够满足禁毒工作的日常需要。  相似文献   

7.
A fully validated, sensitive and specific method for the extraction and quantification of Δ9-tetrahydrocannabinol (THC) and 11-nor-9-carboxy-Δ9-THC (THC-COOH) and for the detection of 11-hydroxy-Δ9-THC (11-OH THC) in oral fluid, urine and whole blood is presented. Solid-phase extraction and liquid chromatography–mass spectrometry (LC–MS) technique were used, with electrospray ionization. Three ions were monitored for THC and THC-COOH and two for 11-OH THC. The compounds were quantified by selected ion recording of m/z 315.31, 329.18 and 343.16 for THC, 11-OH THC and THC-COOH, respectively, and m/z 318.27 and 346.26 for the deuterated internal standards, THC-d3 and THC-COOH-d3, respectively. The method proved to be precise for THC and THC-COOH both in terms of intra-day and inter-day analysis, with intra-day coefficients of variation (CV) less than 6.3, 6.6 and 6.5% for THC in saliva, urine and blood, respectively, and 6.8 and 7.7% for THC-COOH in urine and blood, respectively. Day-to-day CVs were less than 3.5, 4.9 and 11.3% for THC in saliva, urine and blood, respectively, and 6.2 and 6.4% for THC-COOH in urine and blood, respectively. Limits of detection (LOD) were 2 ng/mL for THC in oral fluid and 0.5 ng/mL for THC and THC-COOH and 20 ng/mL for 11-OH THC, in urine and blood. Calibration curves showed a linear relationship for THC and THC-COOH in all samples (r2 > 0.999) within the range investigated.The procedure presented here has high specificity, selectivity and sensitivity. It can be regarded as an alternative method to GC–MS for the confirmation of positive immunoassay test results, and can be used as a suitable analytical tool for the quantification of THC and THC-COOH in oral fluid, urine and/or blood samples.  相似文献   

8.
A quantitative LC-MS/MS method has been developed for the simultaneous determination of 17 antipsychotic drugs in human postmortem brain tissue. Sample preparation was performed using Hybrid Solid Phase Extraction-Precipitation technology for the removal of endogenous protein and phospholipid interferences. The chromatographic separation was performed for 16 min on a C8 column, which used a gradient elution of formate ammonium and acetonitrile, and a flow rate gradient. Triple quadrupole mass spectrometry was employed to generate tandem mass spectrometric (MS/MS) data of the target analytes to select the ion m/z signals. Quantitation of the analytes was performed by operating in the dynamic multiple reaction monitoring (dMRM) mode using an electrospray ionization interface. Calibration curves prepared in the spiked brain tissue were linear in the range 20-8000 ng/g (r(2)>0.993) for all drugs (except olanzapine). Within- and between-day coefficients of variation were lower than 25% for all drugs at the LOQ. The LOQ in the matrix ranged between 2 ng/g and 80 ng/g. The method was successfully applied to the unequivocal identification and accurate quantification of antipsychotic drugs in human postmortem brain tissues: therefore, this method can be used in forensic investigations.  相似文献   

9.
目的建立血液中双甲脒及其代谢产物单甲脒的气质联用定量检测方法。方法采用液-液萃取前处理,考察了不同的提取溶剂和pH值对检测结果的影响,优化了萃取条件。结果在最优条件下,该方法对双甲脒和单甲脒的检出限分别为2ng/mL和3ng/mL,两种目标物在20~2000ng/mL范围内线性关系良好(砰分别为0.9997和0.9992),血液中双甲脒和单甲脒的回收率为8l%~90%。结论该方法具有良好的灵敏度、重现性、稳定性和专属性,可用于法庭科学与临床学的毒物分析。  相似文献   

10.
The purpose of this study was to evaluate the efficiency of the Cozart RapiScan (CRS) drug test system for detecting opiates and cocaine in oral fluid. Oral fluid samples were collected using the Cozart RapiScan collection system from 358 donors who were receiving treatment for their addiction and were monitored for drug misuse. A further 103 oral fluid samples were collected from volunteer donors who were not drug users. The samples were analyzed in the laboratory using the two-panel Cozart RapiScan cartridge for opiates and cocaine and confirmed using gas chromatography-mass spectrometry (GC-MS). The samples were stored frozen at -20 degrees C until analysis by GC-MS. The overall accuracy of the CRS for both opiates and cocaine was 100%. Samples spiked at 50% above and below the cut-off consistently gave negative and positive results respectively. A total of 88 samples were positive for various opiates and 111 samples were positive for cocaine and/or its metabolites. The CRS for opiates and cocaine in oral fluid, using a cut-off of 30 ng/mL morphine or benzoylecgonine equivalents in neat oral fluid, had overall efficiencies of 98% and 99%, respectively, versus GC-MS. A series of potential adulterants of oral fluid were evaluated and shown not to alter the outcome of the test result.  相似文献   

11.
Anticoagulant rodenticides are widely used for rodent control around the world. A rapid and sensitive method was developed and validated for the simultaneous determination of 13 anticoagulant rodenticides (coumafuryl, pindone, valone, warfarin, coumatetralyl, coumachlor, diphacinone, dicumarol, chlorophacinone, bromadiolone, difenacoum, flocoumafen, and brodifacoum) in human blood by liquid chromatography–tandem mass spectrometry. After liquid–liquid extraction, the anticoagulant rodenticides were separated on an Eclipse Plus C18 column. Linearities were observed for each analyte in blood ranging from 0.5 to 50 ng/mL, with correlation coefficients over 0.99. The limits of detection ranged from 0.01 to 0.2 ng/mL, and the limits of quantification were 0.5 ng/mL for all analytes. The intraday and interday precisions were <15%, and accuracies ranged from 80.3% to 111.0%. This validated method with high sensitivity has been applied in three anticoagulant rodenticide poisoning cases and has been used successfully in monitoring blood concentrations for months.  相似文献   

12.
The objective of the present work was to compare previously published methods and provide validation data to detect simultaneously cocaine (COC), benzoylecgonine (BE) and norcocaine (NCOC) in nail. Finger and toenail samples (5mg) were cut in very small pieces and submitted to an initial procedure for external decontamination. Methanol (3 ml) was used to release analytes from the matrix. A cleanup step was performed simultaneously by solid-phase extraction (SPE) and the residue was derivatized with pentafluoropropionic anhydride/pentafluoropropanol (PFPA/PFP). Gas chromatography-mass spectrometry (GC-MS) was used to detect the analytes in selected ion monitoring mode (SIM). Confidence parameters of validation of the method were: recovery, intra- and inter-assay precision, as well as limit of detection (LOD) of the analytes. The limits of detection were: 3.5 ng/mg for NCOC and 3.0 ng/mg for COC and BE. Good intra-assay precision was observed for all detected substances (coefficient of variation (CV)<11%). The inter-assay precision for norcocaine and benzoylecgonine were <4%. For intra- and inter-assay precision deuterated internal standards were used. Toenail and fingernail samples from eight declared cocaine users were submitted to the validated method.  相似文献   

13.
A method for the simultaneous determination of cocaine (COC) and cocaethylene (CE) in human hair was developed, using solid-phase microextraction (SPME) and gas chromatography-mass spectrometry (GC-MS) as analytical technique to identify and quantify the drugs. Selected ion monitoring (SIM) mode was used to obtain higher sensitivity. The deuterated-labeled analogues were used as internal standards. The detector response was linear for the drugs studied over the range 0.4-15 ng/mg, with correlation coefficients higher than 0.995. The coefficients of variation oscillated between 0.65% and 14.18% and the accuracy was in the range from 0.73% to 11.20%. The limits of quantitation and detection were found to be acceptable. Finally, this method was applied to 15 hair samples from cocaine users, obtaining positive results in all cases. The mean concentrations were 5.39 ng/mg (range: 0.43-8.98 ng/mg) for cocaine and 1.11 ng/mg (range: 0.42-2.23 ng/mg) for cocaethylene.  相似文献   

14.
Time-of-flight mass spectrometry (TOF-MS) offers new perspectives for forensic toxicology. Qualitative and quantitative analyses of a mixture of three selected benzodiazepines (diazepam, nordazepam and bromazepam) were used to compare gas chromatography (GC-TOF-MS, quadrupole GC-MS, GC-ECD) and liquid chromatography (HPLC-DAD) data. Method validation parameters like LOD, LOQ, S/N-ratios reflect the capabilities of GC-TOF-MS. Five-point calibrations for bromazepam in human peripheral blood (50, 100, 160, 200, 300 ng/ml) using medazepam as internal standard (1000 ng/ml) were performed. The calibrations using GC-TOF-MS (using the fragments of m/z 236 and 288), GC-ECD (dual system) and HPLC-DAD (at 235 nm) all showed correlation coefficients close or superior to 0.99. Quadrupole GC-MS data was not used in the comparison of extracted samples due to the low sensitivity in the full scan mode. Two analyses of real cases concerning bromazepam are presented. In the first case, the presence or absence of bromazepam could not be established with both HPLC-DAD and GC-ECD due to background signals. The extracted ion chromatograms and spectrum traces after the analysis with the GC-TOF-MS could clearly excluded the presence of bromazepam. The second case illustrates the quantitation of bromazepam, where both HPLC-DAD and GC-ECD were unable to give satisfactory results, again due to interfering background signals. The analyses performed on the GC-TOF-MS-system demonstrated high sensitivity and also high selectivity due to the high quality of mass spectra obtained. The advantages of GC-TOF-MS make it a promising analytical technique for forensic toxicology.  相似文献   

15.
The purpose of this study was to determine the performance characteristics of the Cozart microplate EIA for detecting opiates in oral fluid from patients in a drug misuse treatment program. Oral fluid samples were collected using the Cozart RapiScan Collection System from 216 donors who were receiving treatment for their addiction and were monitored for drug abuse. A further 40 oral fluid samples were collected from volunteer donors who were not drug users. The samples were analyzed in the laboratory by using the Cozart microplate EIA for opiates and confirmed using gas chromatography-mass spectrometry (GC-MS). The samples were stored frozen until analysis by GC-MS. The intra-assay precision for the Cozart microplate oral fluid EIA for opiates over 40 assays was 0.43% to 9.13% CV (within assay) and 2.9% to 9.1% CV (within day). A total of 109 samples were positive for various opiates. The Cozart microplate EIA for opiates in oral fluid, using a cut-off of 30 ng/ml morphine equivalents in neat oral fluid, had a sensitivity of 99.1 +/- 2.1% and a specificity of 94.4 +/- 2.2% versus GC-MS. A series of potential adulterants of oral fluid were evaluated and shown not to alter the outcome of the test result.  相似文献   

16.
生物检材中吗啡类生物碱的LC-MS/MS分析   总被引:7,自引:0,他引:7  
Xiang P  Shen M  Shen BH  Ma D  Bu J  Jiang Y  Zhuo XY 《法医学杂志》2006,22(1):52-54,57
目的针对滥用药物分析鉴定实践中亟待解决的问题,开展LC-MS/MS分析生物检材中吗啡类生物碱的应用研究。方法满足不同的鉴定需要,分别建立血液、尿液、唾液和头发等生物检材的样品前处理方法,确定同时分析海洛因、单乙酰吗啡、吗啡、可待因、乙酰可待因、二氢可待因酮和氢吗啡酮等吗啡类生物碱的LC-MS/MS方法。将方法应用于实际案例。结果所建立的方法对吗啡类生物碱分离良好。尿液稀释法、尿液提取法和头发中吗啡的最低检测限(LOD)分别为10ng/mL、0.01ng/mL和0.01ng/mg。结论所建立的方法简便、快速、特异性强、灵敏度高。目标物中加入二氢可待因酮和氢吗啡酮扩大了方法的实用范围。  相似文献   

17.
Dextromethorphan (DMP), an antitussive, is one of the most popular drugs among the younger generation in Korea. It usually is taken for its hallucinogenic properties and overdoses have been responsible for the fatalities that have been reported frequently. To control the abuse of DMP, the authorities restricted its use through classifying it as a controlled drug on October 2003. The purpose of this study is to provide a standard method for the analysis of DMP and its main metabolite, dextrorphan (DTP) in biological specimens. At first we established a standard operating procedure (SOP) for DMP/DTP in urine, and a method validation was performed. We also quantified DMP from 16 drug abuser's urine samples all of which were positive in the screening test for DMP. For the detection of DMP/DTP, urine samples were adjusted with 6N NaOH (pH 11) and extracted with ethylacetate. Thin layer chromatography was used as the screening test, and the final identification for DMP/DTP was used by GC/MS. The ions (m/z 271 for DMP, m/z 257 for DTP and m/z 86 for lidocaine as internal standard) were extracted from the full scan mass spectrum and were used for quantification. The selectivity, linearity of calibration, accuracy, within- and between day precision, limit of detection and quantification, recovery and stability were examined as parts of the method validation. Extracted calibration curves were linear from 100 to 2000 ng/mL for DMP and DTP with correlation coefficients better than 0.999. Limit detection was 50 ng/mL for DMP and DTP. Within-run precision (%CV) for DMP and DTP at three different concentrations (100, 500 and 1000 ng/mL) was 6.10-18.85%, and between-run precision was 1.70-7.86% for DMP and DTP. Absolute recovery for DMP and DTP was 57-74%, and relative recovery (extraction efficiency) was 80-89%. For 16 drug abuser's urine samples, the concentrations of DMP and DTP were 0.16-52.63 and 0.41-23.75 microg/mL, respectively. Method validation is an important requirement in the practice of chemical analysis, and it will be particularly useful in verifying the reliability of analytical results in the field of forensic science.  相似文献   

18.
4-Fluoroamphetamine (4-FA) was detected in the blood and urine of two individuals suspected for driving under the influence (DUI). The test for amphetamines in urine subjected to immunoassay screening using the CEDIA DAU assay proved positive. Further investigations revealed a 4-FA cross-reactivity of about 6% in the CEDIA amphetamine assay. 4-FA was qualitatively detected in a general unknown screening for drugs using GC/MS in full scan mode. No other drugs or fluorinated phenethylamines were detected. A validated GC/MS method was established in SIM mode for serum analysis of 4-FA with a limit of detection (LOD) of 1 ng/mL and a lower limit of quantification (LLOQ) of 5 ng/mL. Intra-assay precision was approx. 4% and inter-assay precision approx. 8%. Applying this method, the 4-FA serum concentrations of the two subjects were determined to be 350 ng/mL and 475 ng/mL, respectively. Given the pharmacological data of amphetamine, 4-FA psychoactive effects are to be expected at these serum levels. Both subjects exhibited sympathomimetic effects and psychostimulant-like impairment accordingly.  相似文献   

19.
目的建立尿样和头发中甲基苯丙胺的基质辅助激光解吸飞行时间质谱(matrix-assisted laser desorption/ionization time of flight mass spectrometry,MALDI-TOF-MS)分析方法。方法尿样采用液液提取,头发经0.1mol/L盐酸水解后采用液液提取,以碳纳米管为基质应用MALDI-TOF-MS法检测。结果尿样中甲基苯丙胺的最低检测限(LOD)为0.5μg/mL,线线范围为线性范围为0.5~100μg/mL(R2=0.9970);毛发中甲基苯丙胺的最低检测限(LOD)为0.4ng/mg,线性范围为0.4~60ng/mg(R2=0.9976),对送检案例中尿样和头发检材进行检测,效果良好。结论本方法适用于尿样和头发中甲基苯丙胺的分析,与传统气相色谱质谱联用和液相色谱-质谱联用相比,分析速度更快,适合大批量样品同时分析。  相似文献   

20.
An analytical method using solid-phase extraction (SPE) and high-performance liquid chromatography-mass spectrometry (LC-MS) has been developed and validated for the confirmation of Delta(9)-tetrahydrocannabinol (THC) in oral fluid samples. Oral fluid was extracted using Bond Elut LRC-Certify solid-phase extraction columns (10 cm(3), 300 mg) and elution performed with n-hexane/ethyl acetate. Quantitation made use of the selected ion-recording mode (SIR) using the most abundant characteristic ion [THC+H(+)], m/z 315.31 and the fragment ion, m/z 193.13 for confirmation, and m/z 318.00 for the protonated internal standard, [d(3)-THC+H(+)]. The method proved to be precise for THC, in terms of both intra-day and inter-day analyses, with coefficients of variation less than 10%, and the calculated extraction efficiencies for THC ranged from 76 to 83%. Calibration standards spiked with THC between 2 and 100 ng/mL showed a linear relationship (r(2)=0.999). The method presented was applied to the oral fluid samples taken from the volunteers during the largest music event in Portugal, named Rock in Rio-Lisboa. Oral fluid was collected from 40 persons by expectoration and with Salivette. In 55% of the samples obtained by expectorating, THC was detected with concentration ranges from 1033 to 6552 ng/mL and in 45% of cases THC was detected at concentrations between 51 and 937 ng/mL. However, using Salivette collection, 26 of the 40 cases had an undetectable THC.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号