首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 955 毫秒
1.
This article describes the first use of an anti-Stokes material, or up-converter, for the development of latent fingermarks on a range of non-porous surfaces. Anti-Stokes materials can absorb long-wavelength light and emit light at a shorter wavelength. This property is unusual in both natural and artificial materials and so fingermark detection techniques based on anti-Stokes luminescence are potentially sensitive and selective. Latent fingermarks on luminescent and non-luminescent substrates, including Australian polymer banknotes (a well-known 'difficult' surface), were developed with sodium yttrium tetrafluoride doped with erbium and ytterbium (NaYF(4):Er,Yb) by dry powder, wet powder, and cyanoacrylate staining techniques. This study illustrates the potential of up-converter phosphors for the detection of latent fingermarks.  相似文献   

2.
There are numerous types of fluorescent fingermark powders or reagents used with the visualization of latent fingermarks deposited on multicolored substrate surfaces that can present a contrast problem if developed with regular fingermark powders. The developed fingermarks can show bright fluorescence upon exposure to laser, ultraviolet light and other light sources. These kinds of methods share a common concern, where surfaces and other substrates may fluoresce also. To overcome this concern, we have developed a phosphor powder which offers a strong afterglow effect which aid in the establishment of better fingermark detection. With the advent of a phosphor powder no special devices are required and the results obtained from fresh or a few days aged latent fingermarks left on: non-porous; semi-porous and also on some porous surfaces have been good. The strong afterglow effect offered by phosphor powder is also applicable for cyanoacrylate fumed fingermarks. Lift off and photography procedures of the developed fingermarks are incorporated in this paper.  相似文献   

3.
This article describes the use of an anti-Stokes luminescent material (upconverter), yttrium vanadate doped with ytterbium and erbium (YVO(4):Er,Yb), for the development of latent fingermarks on a range of non-porous surfaces. Anti-Stokes luminescent materials emit light at shorter wavelengths than the excitation wavelength. This property is unusual in both natural and artificial materials commonly found as exhibits in forensic science casework. As a result, fingermark detection techniques based on anti-Stokes luminescence are potentially extremely sensitive and selective. Latent fingermarks on non-luminescent and inherently luminescent substrates, including Australian polymer banknotes (a well-known 'difficult' surface), were developed with YVO(4):Er,Yb by dry powder and wet powder techniques. The effectiveness of YVO(4):Er,Yb for fingermark detection was compared with that of cyanoacrylate fuming and of sodium yttrium tetrafluoride doped with ytterbium and erbium (NaYF(4):Er,Yb). The results illustrate some benefit of luminescent up-converting phosphors over traditional luminescence techniques for the detection of latent fingermarks.  相似文献   

4.
Four novel alkyl 2-cyanoacrylate monomers (alkyl=1-cyanoethyl, 2-cyanoethyl, trideuteromethyl and pentadeuteroethyl) have been tested for their ability to develop latent fingermarks that can then be visualized using mid-infrared spectral (chemical) imaging. Each of the four monomers was chosen for its potential to produce a strong, isolated infrared spectral band in its corresponding polymer (to provide spectral contrast against most backgrounds), as well as for its potential ability to be fumed onto fingermarks in the manner of conventional ethyl 2-cyanoacrylate (superglue). With the exception of the 2-cyanoethyl 2-cyanoacrylate, which had to be fumed under reduced pressure, all of the monomers were found to be sufficiently volatile to be fumed in a conventional fuming cabinet. All four monomers polymerized selectively on fingermark ridges on a variety of non-porous and semi-porous surfaces, leading to excellent development of the fingermarks. Unfortunately, although high quality mid-infrared spectral images of the fingermarks could be formed for all of the polymers at various frequencies, the new CN or CD stretching vibrations did not give rise to strong enough absorption intensities for good contrast on difficult backgrounds such as polymer banknotes. However, in the 1-cyanoethyl 2-cyanoacrylate polymer, the presence of the additional nitrile group had the unintended but desirable effect of shifting the strong CO absorption to higher frequencies, moving it away from interfering banknote absorptions. This enabled fingermark contrast to be achieved even against the intaglio printing on the banknotes.  相似文献   

5.
目的研发一种具有荧光特性的黄湿粉,以提取遗留在不同客体上的不同种类的手印。方法在100mL温水中加入适量的表面活性剂,溶解后加入100g荧光黄颜料,选用不同种类客体及不同种类物质手印进行显现实验,比较显现效果;结果遗留在光滑非渗透性客体及半渗透性客体表面的汗潜、油潜手印,显出的手印纹线流畅、反差强、荧光强;结论荧光黄湿粉可适用于光滑非渗透性客体及半渗透性客体表面新鲜或较新鲜汗潜手印、油潜手印及血潜手印的显现。  相似文献   

6.
《Science & justice》2020,60(5):473-479
Powder suspensions such as wet powder are used to develop fingermarks on adhesive surfaces. They can also be used on gloves but these ready-to-use commercial pre-mixed solutions are not entirely satisfactory. Among other things, they generate some background noise that can sometimes be substantial and make the exploitation of the fingermarks difficult. Recent studies have proven the effectiveness of a HFE ninhydrin solution on some types of gloves. Ninhydrin and 1,2-indanedione are reagents that are commonly used for the visualisation of fingermarks on porous and semi-porous substrates. Applying them on gloves might help to overcome the issue of background noise being produced by powder suspensions. In this study, several formulations of ninhydrin and 1,2-indanedione are compared to wet powder on a sample of nitrile, latex and vinyl gloves. The subsequent results show a greater effectiveness with the use of wet powder.  相似文献   

7.
A new, highly fluorescent dye was synthesised using oleylamine combined with a perylene dianhydride compound. The new dye was characterised by 1H NMR, UV-vis spectroscopy and fluorescence spectroscopy as well as quantum yield. The dye was absorbed onto titanium dioxide nanoparticles for use as a fingerprint detection powder. The new fluorescent powder was applied to latent fingermarks deposited onto different non-porous surfaces and compared with commercial fluorescent powders. The powder exhibits strong fluorescence at 650-700 nm under excitation at 505 nm. On glass surfaces, the new powder gave images showing tertiary-level detail of the fingermark ridges with almost no background development. Compared with current magnetic fluorescent powders, the new powder was slightly weaker in fluorescence intensity but produced significantly less background development, resulting in good contrast between the fingermark and the substrate.  相似文献   

8.
《Science & justice》2014,54(3):185-191
Recent studies have reported the use of alginate in the lifting and subsequent enhancement of footwear marks in blood. A study was set up to assess the use of such a method in the treatment of fingermarks in blood on a variety of porous, non-porous and semi-porous surfaces. Other variables included ageing of the fingermarks in blood and the application of chemicals prior to or post-alginate lifting. All different variations were compared to direct chemical treatment of the substrate. The results demonstrated that alginate is not compatible with certain substrates (e.g. glass and tile). On substrates that were compatible with alginate (e.g. fabric and paper), the enhanced fingermarks on the alginate cast and the enhanced fingermarks on the post-alginate substrates appeared, overall, inferior compared to direct chemical enhancement without the use of alginate. A further variation using water-based protein stains directly mixed with the alginate appeared to provide enhancement directly on the substrate as well as simultaneous lifting and enhancing the fingermarks in blood on the alginate cast.  相似文献   

9.
目的探索新的手印显现方法,祛除传统手印显现方法对使用者的健康危害;方法用浅色调湿粉采用不同操作对不同客体表面手印、不同物质手印及不同遗留时间手印进行显现,通过显现效果的比较,得出湿粉显现手印的适用范围、最佳操作方法及其显现效果;结果显出的手印清晰、流畅,与背景反差强;结论该方法适用于光滑非渗透性客体表面及潮湿或粘性表面的汗潜、油潜、蛋白手印的显现,使用方便有效。  相似文献   

10.
Vacuum metal deposition (VMD) is a well-established technique that can be used for the development of latent fingermarks on a range of polymer surfaces, including polyethylene (PE) bags exposed to harsh environmental conditions. The technique has also proved to be effective on difficult semi-porous surfaces such as the polymer banknotes in circulation in Australia and in an increasing number of other countries. VMD is a two-stage technique. In the first stage, a small amount of gold is deposited under high vacuum onto the exhibit. This is then followed by the deposition, onto the gold layer, of a much thicker layer of zinc. Normal VMD development is characterised by zinc depositing all over the surface except on the fingermark ridges themselves. A phenomenon of reverse development (zinc on the ridges but not on the surface) has been reported by many authors. Recent studies indicated that this phenomenon might occur on low-density polyethylene (LDPE) when the amount of deposited gold is above an optimum quantity. The results suggested that the size of the gold agglomerates formed on the surface of the polymer plays a critical role. This preliminary study was aimed at visualising, by transmission electron microscopy (TEM), the formation of gold agglomerates on polymer surfaces to gain an appreciation of how the density and size of these agglomerates changes with an increasing amount of evaporated gold.  相似文献   

11.
There are many techniques available for the recovery of fingermarks at scenes of crime including the possibility of taking casts of the marks. Casts can be advantageous in cases where other destructive recovery techniques might not be suitable, such as when recovering finger marks deposited on valued or immobile items. In this research, Isomark (a silicone-based casting material) was used to recover casts of finger marks placed on a variety of substrates. Casts were enhanced using cyanoacrylate fuming. Good quality marks were successfully recovered from a range of smooth, non-porous surfaces. Recovery from semi-porous surfaces was shown to be inefficient. DNA was subsequently extracted from the casts using QIAamp Mini extraction kits, amplified and profiled. Full DNA profiles were obtained 34% of samples extracted.  相似文献   

12.
The sublimation of copper phthalocyanine (CuPc) at a temperature of 400°C under conditions of reduced pressure is shown to be an effective method of developing latent fingermarks on certain types of surface. Preliminary experiments on a limited selection of surfaces including paper, plastic and ceramic tiles were carried out using a simple apparatus consisting of a vacuum desiccator and a resistive heater. CuPc from the gas phase condenses preferentially on fingermark deposits, revealing deep blue patterns with excellent ridge detail clarity on light coloured surfaces. The technique is shown to be most effective on porous surfaces such as paper, but relatively ineffective on non-porous ceramic and plastic surfaces.  相似文献   

13.
The effect of the shape of semiconductor nanocrystals on their performance for visualising latent fingermarks was investigated for the first time. Highly luminescent CdSe/CdS core/shell nanocrystals in rod and spherical shapes were synthesised in organic solvent and transferred to aqueous solution using ligand exchange. The 3-mercaptopropionic acid coated nanorods and nanospheres were characterised using electron microscopy and UV-visible absorbance and luminescence spectrophotometry. A simple and rapid development of fresh to less than a week-old natural fingermarks from 4 donors (male and female) on non-porous surfaces including glass slides, aluminium foil and germanium disks using both CdSe/CdS core/shell nanorods and spherical dots was achieved, wherein nanorods demonstrated an enhanced development of ridge details in comparison to the spherical dots.  相似文献   

14.
The use of a new technique, Fourier transform infrared (FTIR) chemical imaging, has been demonstrated for the enhancement of latent fingermarks on a number of surfaces. Images of untreated fingermarks on glass backgrounds with excellent ridge detail were acquired using infrared chemical imaging. High quality fingermarks on glass backgrounds were also developed using ethyl cyanoacrylate (super glue) fuming and subsequent infrared chemical imaging. This new method allows the collection of images from backgrounds that traditionally pose problems for current fingermark detection methods. The background may, for example, be highly colored, have a complex pattern, or possess other pattern or image characteristics that make it difficult to separate fingermark ridges using traditional optical or luminescent visualization. One background that has proven to be a challenging surface for the development of latent fingermarks is the Australian polymer banknote. To demonstrate the power and applicability of infrared chemical imaging, fingermarks fumed with ethyl cyanoacrylate were successfully imaged from Australian polymer banknotes.  相似文献   

15.
The abilities of two natural products, genipin and lawsone, to enhance blood contaminated fingermarks on papers of various porosities and colour were investigated and compared to the routinely used amino acid reagents, ninhydrin and 1,8-diazafluoren-9-one (DFO).Fingermarks in blood were deposited as a split depletion series on various paper types and colours for ageing periods of 6 weeks, 4 weeks, 2 weeks and 1 week before enhancement. The developed marks were observed under different lighting conditions, recorded and graded by way of attributing quantitative data to each series.Results indicated that while genipin showed some potential as a reagent for the enhancement of latent fingermarks, it displayed no suitability for the enhancement of fingermarks in blood on paper. Lawsone also failed to successfully enhance either type of fingermark. Upon comparison of the results with those of ninhydrin and DFO it was found that ninhydrin displayed the highest success rate of development of these marks.  相似文献   

16.
《Science & justice》2022,62(5):644-656
The surface structure of mint (as-issued) and handled polymer five pounds sterling banknotes was studied by atomic force microscopy and laser scanning confocal microscopy. A total of 1856 fingermarks on mint and handled banknotes from four different issuing banks (Bank of England, Bank of Scotland, Royal Bank of Scotland and Clydesdale Bank) were visualised with Vacuum Metal Deposition (VMD), Cyanoacrylate Fuming (CAF) and, on Clydesdale Bank notes, magnetic fluorescent powder. VMD was significantly more effective in developing fingermarks on handled banknotes, across all the banks studied, although effectiveness varied with issuing bank. For example, on handled Bank of England notes 45% of marks showed ridge detail with VMD development and 28% with CAF; for Bank of Scotland handled notes success rates were 17% with VMD and 1% with CAF. Microscopy of degraded banknotes showed the loss of intaglio printing and the formation of a cracked surface structure in the handled notes. These features can lead to the trapping of powder, or contaminants, increasing quantity of development agent in fingermark background between the ridges, decreasing contrast and decreasing performance of powder-based fingermark development techniques. These same features can restrict the migration of components of the fingermark, preventing fingermarks degrading through spread of material and thus reducing potential formation of empty prints, so that VMD development is not adversely affected.  相似文献   

17.
The ability of two mass spectrometric methods, surface-assisted laser desorption/ionization-time of flight-mass spectrometry (SALDI-TOF-MS) and direct analysis in real time (DART-MS), to detect the presence of seven common explosives (six nitro-organic- and one peroxide-type) in spiked latent fingermarks has been examined. It was found that each explosive could be detected with nanogram sensitivity for marks resulting from direct finger contact with a glass probe by DART-MS or onto stainless steel target plates using SALDI-TOF-MS for marks pre-dusted with one type of commercial black magnetic powder. These explosives also could be detected in latent marks lifted from six common surfaces (paper, plastic bag, metal drinks can, wood laminate, adhesive tape and white ceramic tile) whereas no explosive could be detected in equivalent pre-dusted marks on the surface of a commercial lifting tape by the DART-MS method due to high background interference from the tape material. The presence of TNT and Tetryl could be detected in pre-dusted latent fingermarks on a commercial lifting tape for up to 29 days sealed and stored under ambient conditions.  相似文献   

18.
In many crimes, the elapsed time between production and collecting fingermark traces is crucial. and a method able to detect the aging of latent prints would represent an improvement in forensic procedures. Considering that as the latent print gets older, substantial changes in the relative proportion of individual components secreted by skin glands could affect the morphology of ridges, morphometry could be a potential tool to assess the aging of latent fingermarks. Then, considering the very limited research in the field, the present work aims to evaluate the morphometry of latent palmprint ridges, as a function of time, in order to identify an aging pattern. The latent marks were deposited by 20 donors on glass microscope slides considering pressure and contact angle, and then were maintained under controlled environmental conditions. The morphometric study was conducted on marks developed with magnetic powder in 7 different time intervals after deposition (0, 5, 10, 15, 20, 25 or 30 days); 60 ridges were evaluated for each developed mark. The results showed that: 1) the method for the replacement and mixing of skin secretions on the palm was appropriate to ensure reproducibility of latent prints, and 2) considering the studied group, there was a time-dependent reduction in the width of ridges and on the percentage of visible ridges over 30 days. Results suggest the possibility of using the morphometric method to determine an aging profile of latent palmprints on glass surface, aiming for forensic purposes.  相似文献   

19.
Conventional fingermark powders rely on contrast induced by absorption/reflection (e.g. black powder) or luminescence in the visible region (e.g. Blitz Green(?)). In most cases, these powders provide sufficient contrast; however, in some circumstances surface characteristics can interfere with the visualisation of powdered fingermarks. Visualisation in the near infra-red (NIR) region, however, has been shown to eliminate interferences commonly encountered in the visible region. In this study, a mixture of rhodamine 6G and the NIR laser dye styryl 11 (STaR 11) was coated onto an aluminium oxide nanopowder and then mixed with silver magnetic powder to develop and visualise fingermarks in the NIR. When compared to Blitz Green(?), it was determined that the STaR 11 magnetic powder was better suited for marks deposited on textured surfaces and for older marks, whereas Blitz Green(?) performed better on smooth glossy surfaces. The ability of the STaR 11 mixed dye formulation to be visualised in both the visible and NIR regions also provides a significant advantage over conventional luminescent fingermark powders.  相似文献   

20.
《Science & justice》2021,61(5):617-626
Corrosive substance attacks have become a growing issue within the UK. Although most commonly occurring in gang-related offences, there are high profile instances where this type of attack has been used to attack women to disfigure and destroy livelihoods. Despite the increase in such attacks, there has been very little published research into the recovery of forensic evidence from items used in these crimes. The effect of corrosive substances on the recovery of different types of forensic evidence is unknown, and there is no guidance for laboratories processing exhibits contaminated with corrosive substances regarding optimum treatments. This pilot study focused on establishing the effectiveness of a range of fingermark visualisation processes in recovering fingermarks on surfaces exposed to concentrated sulfuric acid (acid) and potassium hydroxide (alkali). Results indicate that on non-porous surfaces vacuum metal deposition and powder suspensions remain effective, and on porous surfaces fingermarks could still be visualised with physical developer. Alkalis were found to be more detrimental than acid environments in this limited study. The results demonstrate that fingermark recovery is still feasible on surfaces exposed to corrosive substances and provides encouragement that treatment protocols could be developed for this type of exhibit.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号