首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This study compares two novel swabs (forensiX) with a standard cotton swab (EUROTUBE) for the collection of saliva stains on glass slide for STR analysis. ForensiX collection tubes are a standard cotton swab in an “active drying” tube, where swab sample is soon dried by its innovative tube surface of the wall. The other is forensiX Nylon Flocked Swab. The study is two phases: The first “phase” assesses swab types regarding to retrieve ability of saliva. The second “phase” compares the drying ability of each swab to assess how crime samples would fare when left in storage. The main result showed that “active drying” is effective to store swabbed sample. The forensiX swabs generally are effective for higher (twofold to fourfold) DNA yield compared to delta lab swab (around 750 pg and 250 pg from 0.5 μL of saliva), respectively. These findings demonstrate the importance of drying performance in the preservation of DNA and swab selection.  相似文献   

2.
Following forensic DNA profiling (extraction, quantification and STR typing) the remaining extract is generally stored frozen. Our routine at the Swedish National Forensic Centre is to immediately after analysis freeze the sample. If a subsequent reanalysis is needed the sample is thawed and then refrozen. In this study the effects of freezing and thawing as well as long-term storage of DNA extracts in refrigerator or freezer have been investigated. The following sample types were extracted: two levels of blood and saliva, saliva on cigarette filter paper, saliva on cotton swabs and a combination of saliva and semen to mimic samples from sexual assaults. All extraction methods used were Chelex-based, DNA quantification was performed using PowerQuant System and STR profiling with PowerPlex ESX 16 Fast System. The study was divided into three parts: 1) freezing and thawing the extracts up to ten times, 2) storage in refrigerator or freezer up to four weeks and 3) long-term storage in refrigerator or freezer for 3, 6, 9, 12 and 35 months. Generally, the quantification and STR typing results show no indication of degradation after repeated freezing and thawing or long-term storage in refrigerator or freezer.  相似文献   

3.
Traditional methods for bone pulverization typically generate heat, risking stability of DNA sample. SPEX? has developed cryogenic grinders which introduce liquid nitrogen to cool the sample and aid in the grinding process. In this study, the Freezer Mill 6970 EFM was used with two DNA extraction methods and routine downstream STR analysis procedures. DNA from as little as 0.1 g of bone powder was used to develop full STR profiles after freezer mill pulverization, and the method was reproducible. Further, no contamination was detected upon cleaning/reuse of the sample vials. There were no significant differences in DNA yield, STR alleles detected, or peak heights using the freezer mill as compared to traditional grinding, and successful DNA profiles were achieved from as low as 0.1 g of bone powder with this method. Overall, this work indicates that this cryogenic mill method may be used as a viable alternative to traditional tissue grinders.  相似文献   

4.
Forensic DNA analysis is a multi-step process involving extraction of DNA, quantification of human DNA in the extract, amplification using multiplex STR systems, separation of products, and data analysis. The backlog of forensic casework is increasing worldwide. Automation is one significant way to alleviate the bottleneck of sample processing in forensic labs. The HID EVOlution™ Combination System described here is a robust, reliable sample processing platform, easily adapted to forensic laboratory workflows. Using a variety of forensic sample types including: blood stained FTA paper, cotton fabric and denim, dried blood spiked with known PCR inhibitors, saliva on cotton swabs, and semen stains, we found that yields of human DNA and STR profiles obtained with AmpFlSTR® Idenitfiler® kits were complete, highly reproducible, and equivalent to results obtained using the manual PrepFiler™ reagent extraction method. Automated operation was clean, and no cross-contamination was detected between extraction blanks and interspersed high DNA content samples.  相似文献   

5.
Because of the increase of evidence of blood stains, that have been washed or cleaned in an attempt to mask the analysis of DNA profiles, there is also an increase in the use of presumptive tests on samples sent to laboratories. Some of the presumptive tests, used to identify blood and semen stains, could potentially affect the recovery of high molecular weight DNA from the samples, or extinguish them, especially those already present in small quantities. After the presumptive tests, often these samples are discarded. This study aimed to examine the possibility of obtaining a DNA profile from samples submitted for presumptive testing and cleaned with bleaches with and without chlorine. Two different protocols were conducted: (a) A unique sample of human blood in natura (5 μL), already typed through the DNA techniques with the genetic profile previously known (control), was distributed onto cotton fabrics and dried at room temperature. Four samples of fabric were macerated in saline solution and Coombs serum and then stored for three months (room temperature and freezer −20 °C). (b) Another sample of human blood, type A, in natura, already typed through the techniques of DNA (control) was used. Aliquots of 200 μL were distributed in: cotton, denim and synthetic fabric. The samples were dried at room temperature for 24 h. The blood stains in those fabrics (cotton, denim and synthetic) were then divided into three groups: unwashed, cleaned with chlorine bleach and cleaned with chlorine bleach and soap powder. The samples were again dried at room temperature for 24 h, before the use of luminol. The DNA were extracted with Chelex 100 and amplified with the Identifiler Kit (Applied Biosystems). The blood stains exposed to saline and Coombs serum had DNA profiles consistent with untreated samples (controls). This result shows that the experts should keep and store the samples treated with saline and Coombs serum for future DNA confrontation when necessary. Also discussed in this paper the pattern of blood stains after washing with bleaching solutions, as well as the quantity of DNA obtained from these samples.  相似文献   

6.
Forensic laboratories employ various approaches to obtain short tandem repeat (STR) profiles from minimal traces (<100 pg DNA input). Most approaches aim to sensitize DNA profiling by increasing the amplification level by a higher cycle number or enlarging the amount of PCR products analyzed during capillary electrophoresis. These methods have limitations when unequal mixtures are genotyped, since the major component will be over-amplified or over-loaded. This study explores an alternative strategy for improved detection of the minor components in low template (LT) DNA typing that may be better suited for the detection of the minor component in mixtures. The strategy increases the PCR amplification efficiency by extending the primer annealing time several folds. When the AmpF?STR® Identifiler® amplification parameters are changed to an annealing time of 20 min during all 28 cycles, the drop-out frequency is reduced for both pristine DNA and single or multiple donor mock case work samples. In addition, increased peak heights and slightly more drop-ins are observed while the heterozygous peak balance remains similar as with the conventional Identifiler protocol. By this extended protocol, full DNA profiles were obtained from only 12 sperm heads (which corresponds to 36 pg of DNA) that were collected by laser micro dissection. Notwithstanding the improved detection, allele drop-outs do persist, albeit in lower frequencies. Thus a LT interpretation strategy such as deducing consensus profiles from multiple independent amplifications is appropriate. The use of extended PCR conditions represents a general approach to improve detection of unequal mixtures as shown using four commercially available kits (AmpF?STR® Identifiler, SEfiler Plus, NGM and Yfiler). The extended PCR protocol seems to amplify more of the molecules in LT samples during PCR, which results in a lower drop-out frequency.  相似文献   

7.
The extraction and recovery efficiency of swabs used to collect evidence at crime scenes is relatively low (typically <50%) for bacterial spores and body fluids. Cell‐free deoxyribonucleic acid (DNA) is an interesting alternative compared to whole cells as a source for forensic analysis, but extraction and recovery from swabs has not been tested before using pure DNA. In this study cotton, foam, nylon flocked, polyester and rayon swabs are investigated in order to collect pure DNA isolated from saliva samples. The morphology and absorption capacity of swabs is studied. Extraction and recovery efficiencies are determined and compared to the maximum theoretical efficiency. The results indicate that a substantial part of DNA is not extracted from the swab and some types of swab seem to bind effectively with DNA. The efficiency of the different types of swab never exceeds 50%. The nylon flocked 4N6FLOQSwab used for buccal sampling performs the best.  相似文献   

8.
Amylase testing has been used as a presumptive test for crime scene saliva for over three decades, mainly to locate saliva stains on surfaces. We have developed a saliva screening application for crime scene trace swabs, utilising an amylase sensitive paper (Phadebas® Forensic Press test). Positive results were obtained for all tested dried saliva stains (0.5–32 μL) with high or intermediate amylase activity (840 and 290 kU/L). Results were typically obtained within 5 min, and all samples that produced DNA profiles were positive. However, salivary amylase activities, as well as DNA concentrations, vary significantly between individuals. We show that there is no correlation between amylase activity and amount of DNA in fresh saliva. Even so, a positive amylase result indicates presence of saliva, and thereby presence of DNA. Amylase testing may be useful for screening in investigations where the number of DNA analyses is limited due to cost, e.g., in volume crime.  相似文献   

9.
Saliva and saliva-stained materials were examined as potential sources of deoxyribonucleic acid (DNA) for DNA analysis and identity testing. In this paper, the authors demonstrate that DNA was isolated and DNA banding patterns suitable for DNA typing were obtained from fresh saliva and various saliva-stained materials, such as envelopes, buccal swabs, gags, and cigarettes. Furthermore, DNA and DNA banding patterns were obtained from actual forensic evidentiary samples containing mixed saliva/semen stains. The DNA banding patterns obtained from saliva or saliva-stained material were indistinguishable from the patterns obtained from blood or hair from the same individual. Intact DNA was readily isolated and DNA banding patterns were obtained from saliva stored at -20 degrees C and dried saliva stains stored under varying conditions. We conclude that saliva and saliva-stained material can be good sources of DNA for analysis and for DNA typing in certain forensic settings.  相似文献   

10.
The ability to properly collect, analyze and preserve biological stains is important to preserving the integrity of forensic evidence. Stabilization of intact biological evidence in cells and the DNA extracts from them is particularly important since testing is generally not performed immediately following collection. Furthermore, retesting of stored DNA samples may be needed in casework for replicate testing, confirmation of results, and to accommodate future testing with new technologies.A novel room temperature DNA storage medium, SampleMatrix™ (SM; Biomatrica, Inc., San Diego, CA), was evaluated for stabilizing and protecting samples. Human genomic DNA samples at varying amounts (0.0625-200 ng) were stored dry in SM for 1 day to 1 year under varying conditions that included a typical ambient laboratory environment and also through successive freeze-thaw cycles (3 cycles). In addition, spiking of 1-4× SM into samples prior to analysis was performed to determine any inhibitory effects of SM. Quantification of recovered DNA following storage was determined by quantitative PCR or by agarose gel electrophoresis, and evaluation of quantitative peak height results from multiplex short tandem repeat (STR) analyses were performed to assess the efficacy of SM for preserving DNA.Results indicate no substantial differences between the quality of samples stored frozen in liquid and those samples maintained dry at ambient temperatures protected in SM. For long-term storage and the storage of low concentration samples, SM provided a significant advantage over freezer storage through higher DNA recovery. No detectable inhibition of amplification was observed at the recommended SM concentration and complete profiles were obtained from genomic DNA samples even in the presence of higher than recommended concentrations of the SM storage medium. The ability to stabilize and protect DNA from degradation at ambient temperatures for extended time periods could have tremendous impact in simplifying and improving sample storage conditions and requirements. The current work focuses on forensics analysis; however this technology is applicable to all endeavors requiring storage of DNA.  相似文献   

11.
Abstract: The PrepFiler? Forensic DNA Extraction Kit enables isolation of genomic DNA from a variety of biological samples. The kit facilitates reversible binding of DNA with magnetic particles resulting in high DNA recovery from samples with very low and high quantities of biological materials: 0.1 and 40 μL of human blood (donor 2) provided 14 and 2883 ng of DNA, respectively. Following the revised SWGDAM guidelines, performance of the developed method was investigated using different sample types including saliva on swabs, semen stains on cotton fabric, samples exposed to environment, samples with polymerase chain reaction (PCR) inhibitors, blood stains (on denim, cotton cloth, and FTA® paper), and touch evidence‐type samples. DNA yields for all samples tested were equal or better than those obtained by both phenol–chloroform extraction and commercial kits tested. DNA obtained from these samples was free of detectable PCR inhibitors. Short tandem repeat profiles were complete, conclusive, and devoid of PCR artifacts.  相似文献   

12.
Forensic investigations generally involve samples that have unknown storage conditions.These conditions may help to speed up or slow down the degradation of DNA. For example environmental factors that speed up the decay include: UV light, humidity, and temperature. The aim of the present study is to evaluate the effect of high temperature on the ability to perform DNA extraction and typing from different biological fluids (blood, saliva, and semen) after 20 min incubation in an oven at different temperatures 50 °C, 100 °C, 150 °C, and 200 °C or direct exposition to the effect of a flame for few minutes. Our results support the ability to type DNA even from samples exposed to drastic condition.  相似文献   

13.
We have validated and implemented a protocol for DNA extraction from various types of biological materials using a Qiagen BioRobot EZ1 Workstation. The sample materials included whole blood, blood from deceased, buccal cells on Omni swabs and FTA Cards, blood on FTA Cards and cotton swabs, and muscle biopsies. The DNA extraction was validated according to EN/ISO 17025 for the STR kits AmpF?STR® Identifiler® and AmpF?STR® Yfiler® (Applied Biosystems). Of 298 samples extracted, 11 (4%) did not yield acceptable results. In conclusion, we have demonstrated that extraction of DNA from various types of biological material can be performed quickly and without the use of hazardous chemicals, and that the DNA may be successfully STR typed according to the requirements of forensic genetic investigations accredited according to EN/ISO 17025.  相似文献   

14.
《Science & justice》2023,63(4):529-536
This study examines the background of blood, saliva, semen and autosomal DNA on penile swabs and underpants from males in the absence of recent sexual activity. Based on the data collected by the AFSP Body Fluid Forum, the results of this study show that; there is a very low expectation of detecting blood on penile swabs and male underpants; a low expectation of detecting saliva on penile swabs and male underpants; and spermatozoa would be expected in less than a quarter of penile swabs and three quarters of male underpants. As none of the samples had detectable levels of DNA which were suitable for meaningful comparison that did not match the donor or their partner, the expectation of detecting a DNA profile from the cellular background on penile swabs or underpants from a male who has not been involved in recent sexual intercourse is very low. The results of this study are extremely informative when evaluating the significance of blood, saliva, semen and DNA detected on the penile swabs and underpants of males in cases of alleged sexual assault.  相似文献   

15.
Forensic examiners must determine whether both latent fingerprint development and DNA profiling can be performed on the same area of an evidence item and, if only one is possible, which examination offers the best chance for identification. Latent fingerprints can be enhanced by targeting different components of fingerprint residues with sequential chemical treatments. This study investigated the effects of single-reagent and sequential latent fingerprint development processes on downstream DNA analysis to determine the point at which latent fingerprint development should be stopped to allow for DNA recovery. Latent fingerprints deposited on copy paper by one donor were developed using three sequential processes: 1,8-diazafluoren-9-one (DFO) → ninhydrin → physical developer (PD); 1,2-indanedione-zinc (IND-Zn) → ninhydrin → PD; and IND-Zn → ninhydrin → Oil Red O (ORO) → PD. Samples were examined after the addition of each chemical treatment. DNA was collected with cotton swabs, extracted, quantified, and amplified. DNA yields, peak heights, number of alleles obtained, and percentage of DNA profiles eligible for CODIS upload were examined. DNA profiles were obtained with varying degrees of success, depending on the number and type of treatments used for latent fingerprint development. The treatments that were found to be the least harmful to downstream DNA analysis were IND-Zn and IND-Zn/laser, and the most detrimental treatments were DFO, DFO/laser, and PD. In general, as the number of treatments increase, the opportunities for DNA loss or damage also increase, and it is preferable to use fewer treatments when developing latent fingerprints prior to downstream DNA processing.  相似文献   

16.
The PrepFiler™ is a new kit recently introduced by Applied Biosystems for DNA extraction from a wide range of forensic samples. In the present study we tested the performance of PrepFiler™ kit against other commonly used commercially available kits on a variety of real forensic casework samples: bloodstains on different substrates, washed bloodstains, semen stains, saliva stains, hairs, bones, tissues, nails, prints after chemical treatments, skin swabs.  相似文献   

17.
With the aim to asses the efficiency of the DNA IQ System in the recovery of DNA from semen samples, cotton swabs were prepared from 1/5 serial dilutions of semen. Each swab was fractionated in four equivalent quarters and the DNA was further extracted following the differential lysis protocol. The recovered DNA was quantified by means of real time PCR and the average DNA yield was used to compare results. Direct extractions of equivalent aliquots of each semen dilution were used as reference samples. Even though a high percentage of the starting material was lost during the process of transfer to/recover from the solid support, our experimental results demonstrated that the DNA IQ system was able to detect around 103 sperm cells in the starting material, enabling to obtain a complete DNA profile with AmpFl STR IdentiFiler PCR Amplification Kit (Applied Biosystems).  相似文献   

18.
Sodium hypochlorite is an efficient reagent for removal of unwanted DNA from laboratory surfaces. Here, we tested two different chlorine wipes and compared their performance to a 0.9–1.8% hypochlorite solution. WipeClean Chlorine Disinfection wipes contain > 0.1 g sodium hypochlorite/kg, whereas WetWipe Chlorine Desinfection wipes contain > 1000 ppm active chlorine. Clean surfaces were contaminated with 10 µL 0.5 ng/µL of massively parallel sequencing libraries. The DNA was dried and left for 45 min before any treatment. The surfaces were cleaned using either 1) a 0.9–1.8% hypochlorite solution and clean wipes, 2) a WipeClean wipe, 3) a WetWipe, or 4) the surface was not cleaned. All experiments were repeated three times. Subsequently, the surfaces were swabbed using cotton swabs. DNA was extracted from the swabs and the DNA concentrations were determined in quadruplicates by real-time PCR. This protocol was repeated after the soft plastic wrapping around the wipes were left open or closed for several weeks. The results showed that the WipeClean wipes efficiently removed DNA for up to four weeks after the box with the wipes were opened, whereas the WetWipe wipes dried faster and gradually lost their cleaning effect.  相似文献   

19.
《Science & justice》2022,62(3):284-287
Forensic DNA profiling is a globally accepted method for human identification, however, obtaining full DNA profiles from trace DNA can be challenging. The optimal recovery of DNA from trace DNA swabs is therefore crucial. Methods for extracting DNA from swabs often make use of a spin basket combined with a centrifugation step, to enhance the release of cells from the swab prior to DNA extraction. The NucleoSpin® Forensic Filter (Macherey-Nagel, Düren) is a type of spin basket, but it has not been thoroughly assessed on trace DNA samples. This study aimed to assess if the inclusion of the NucleoSpin® Forensic Filter significantly improved DNA recovery and DNA profiling success from cotton and flocked swabs used to collect trace DNA and buccal cells (control). Buccal cells and trace DNA samples were collected from 25 volunteers using each swab type (cotton and flocked) in duplicate. DNA was extracted from the samples using the NucleoSpin® DNA Forensic kit, one set with, and the other set without, NucleoSpin® Forensic Filters. DNA concentration was assessed using real time PCR, and DNA profiling was done using the PowerPlex® ESX 16 system. The inclusion of the NucleoSpin® Forensic Filters significantly improved DNA concentration for buccal cells that were collected using flocked swabs (p = 0.035). However, no significant differences were noted for trace DNA samples for either swab type. There was also no significant difference in DNA profiling success when NucleoSpin® Forensic Filters were used, regardless of swab and sample type. These results may be helpful for laboratories that are considering the NucleoSpin® Forensic Filters in the DNA extraction workflow, particularly for trace DNA samples.  相似文献   

20.
Biological evidence analysis from contact traces is adversely affected by low quantity and quality of DNA. Proteins in these samples contain potentially individualizing information and may be particularly important for difficult surfaces such as brass, where DNA may yield incomplete profiles. In this study, touched unfired brass cartridges were sampled using dry tape or wet swabs and analyzed by separating DNA and protein from the same collected material, thus producing both genomic and proteomic information. DNA recovery was similar for both collection methods, with tape yielding an average of 1.36 ± 1.87 ng and swabs, 1.34 ± 3.04 ng. Analysis by mass spectrometry identified 95 proteins, with the two collection methods showing no significant difference (= 0.76) in the average number of collected proteins: 44.5 ± 10.9, (tape) versus 47.9 ± 20.4 (swabs). Proteins can be collected from fingerprints at levels necessary to provide identifying information, thus expanding information obtained from challenging evidence.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号