首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The near inevitable transfer of explosive particulate matter through fingerprints makes it possible to detect concealed explosives through surface sampling. Repeatable and well-characterized fingerprint simulation facilitates quantitative comparison between particulate sampling methods for subsequent detection of trace explosive residues. This study employs a simple, but reproducible sampling system to determine the accuracy of a fingerprint simulation. The sampling system uses a gas jet to entrain particles from a substrate and the resulting airborne particles are then aspirated onto a Teflon filter. A calibrated Barringer IonScan 400 ion mobility spectrometer was used to determine the mass of explosive material collected on the filter. The IonScan 400 was calibrated with known masses of 2,4,6-trinitrotoluene (TNT). The resulting calibration curve is in good agreement with that obtained by Garofolo et al. (1994) for an earlier model of the instrument. The collection efficiency of the sampling system was measured for three particle sizes (8.0. 10.0, and 13.0 microm) using spherical polystyrene particles laced with known quantities of TNT. Collection efficiency ranged from less than 1% for the larger particles to 5% for the smaller particles. Particle entrainment from the surface was monitored with dark field imaging of the remaining particles. The sampling system was then applied to two C4 test samples--a fingerprint transfer and a dry Teflon transfer. Over 100 ng of RDX was collected from the dry transfer sample, while less than 1 ng was collected from the fingerprint transfer. Possible explanations for this large difference are presented based on the system calibration.  相似文献   

2.
《Science & justice》2021,61(6):697-703
The identification and confirmation of trace explosive residues along with potential precursors and degradation products require a comprehensive laboratory analysis procedure. This study presents the determination of organic explosives consisting of hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX), 2,4,6-trinitrotoluene (TNT), 2,4,6,N-tetranitro-N-methylaniline (Tetryl), 1,3,5-trinitrobenzene (1,3,5-TNB) and pentaerythritol tetranitrate (PETN) by a high-resolution liquid chromatography quadrupole time-of-flight mass spectrometry (LC−QTOF/MS). The qualitative information including retention time, collision energy, precursor ions, and characteristic fragmentation pattern of each explosive were collected using an atmospheric pressure chemical ionization (APCI) in negative ion mode. The separation efficiency among five compounds was greatly achieved in this study. Four real explosive samples consisting of TNT, RDX, PETN and Tetryl and 12 Ionscan® quality control swabs from the Royal Thai Army were also tested to validate and verify the viability of the GC–MS method used to validate results from an Ionscan® system. The results showed that LC−QTOF/MS is a powerful technique for the identification and confirmation of thermally unstable organic explosives on Ionscan® swabs compared to a conventional GC−MS technique.  相似文献   

3.
The sorption of explosives (TNT, RDX, PETN, TATP, EGDN) to hair during exposure to their vapors is examined. Three colors of hair were simultaneously exposed to explosive vapor. Following exposure of hair, the sorbed explosive was removed by extraction with acetonitrile and quantified. Results show that sorption of explosives, via vapor diffusion, to black hair is significantly greater than to blond, brown or bleached hair. Furthermore, the rate of sorption is directly related to the vapor density of the explosive: EGDN > TATP >TNT > PETN > RDX. In some cases, the explosive-containing hair was subject to repeated washings with sodium dodecylsulfate or simply left out in an open area to determine the persistence of the explosive contamination. While explosive is removed from hair with time or washing, some persists. These results indicate that hair can be a useful indicator of explosive exposure/handling.  相似文献   

4.
The detection of trace explosives is important for forensic, military, and homeland security applications. Detection of widely used nitroaromatic explosives (trinitrotoluene [TNT], 2,4-dinitrotoluene [DNT], picric acid [PA]) was carried out using photoluminescent metallole-containing polymers. The method of detection is through the quenching of fluorescence of thin films of the polymer, prepared by spray coating organic solutions of the polymer, by the explosive analyte. Visual quenching of luminescence (lambda(em) approximately 400-510 nm) in the presence of the explosive is seen immediately upon illumination with near-UV light (lambda(ex)=360 nm). Detection limits were observed to be as low as 5 ng for TNT, 20 ng for DNT, and 5 ng for PA. In addition, experiments with normal production line explosives and their components show that this technology is also able to detect composition B, Pyrodex, and nitromethane. This method offers a convenient and sensitive method of detection of trace nitroaromatic explosive residue.  相似文献   

5.
This study sought to assign a rough order of magnitude for the amount of explosive residue likely to be available in real-world searches for clandestine explosives. A variety of explosives (TNT, TATP, HMX, AN, RDX, PETN) in various forms (powder, flake, detonating cord, plastic) were carefully weighed or cut into containers, and the amount of residue inadvertently remaining on the work area, hands, or containers was quantified. This was used to evaluate the spillage potential of each explosive. The adhesion of each explosive to a glass surface was quantified from amount of explosive adhering to the inside of a glass vial into which the explosive had been placed and then removed by vigorous tapping. In powdered form, most of the explosives--TNT, PETN, RDX, HMX, and TATP--exhibited similar spillage and adhesion to glass. However, PETN as sheet explosive and plasticized RDX (C-4), showed very little potential to contaminate surfaces, either by spillage or adhesion to glass.  相似文献   

6.
This study examines the sorption of eight explosives (2,4,6-trinitrotoluene [TNT]; pentaerythritol tetranitrate [PETN]; hexahydro-1,3,5-trinitro-s-triazine [RDX]; diacetone diperoxide [DADP]; triacetone triperoxide [TATP]; ethylene glycol [EGDN], nitroglycerin [NG]; and 2,4-dinitrotoluene [DNT]) to human hair. The study uses only cut hair, which is exposed to explosive vapor. The vapor transfer studies reported herein indicated that hair did not reach saturation even after 2.5 years of exposure to TNT. While previous studies showed black hair sorbed more explosive than blond or brown, this study reports that red hair sorption is similar to black, while grey hairs, exposed along with black hair from the same individual, sorbed significantly less explosive than the same individual's black hairs. In a study using only black hair, a slight racial bias was observed with sorption greater for Mongoloid hair as compared to Caucasian or Negroid. Only for Mongoloid hairs were enough samples studied to examine for a gender bias, but one was not observed. There was much variability in results in all categories (hair color, race, and gender) that trends were established only in general terms. Hair at different ages was tested for a few individuals. Detailed studies focused on the sorption of TATP and TNT as these appear to be sorbed most differently-TATP mainly on the hair surface and TNT both on the surface and in the cortex. The uptake of high vapor pressure explosives (e.g., TATP) and moderate vapor pressure explosives (e.g., TNT) by hair was rapid and could be detected within about 1 h of exposure. Both explosives were readily sorbed by pure melanin.  相似文献   

7.
Trace explosive test surfaces are often required for the evaluation of trace detection equipment to determine the equipment performance. Test surfaces of C‐4, Detasheet, Semtex‐H, TNT, and HMTD were prepared by transferring trace amount of explosive deposited on polytetrafluoroethylene (PTFE) transfer strips onto different surfaces (Kraft paper, hard plastic, woven fabric, and soft vinyl). The amount of explosive transferred was deduced from the amount of explosive remaining on the PTFE strips after transfer, as quantified by direct analysis using tandem mass spectrometry with thermal desorption. From the data set of over 2000 transfers, we experienced lower transfer efficiency for Semtex‐H and Detasheet, and for soft vinyl and hard plastic. However, the rapid quantification mass spectrometric method allowed the transfer efficiency to be determined for all test surfaces used in an evaluation of trace explosive detectors, thereby permitting only the test surfaces with desired transfer to be accepted for the assessment.  相似文献   

8.
Commercially available skin cleansing alcohol wipes and conventional swabs were investigated for their use as a universal sampling medium for the simultaneous collection of both organic and inorganic explosive residues. Six compounds with the potential to be encountered in casework [pentaerythritol tetranitrate (PETN), 2,4,6-trinitrotoluene (TNT), hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX), triacetone triperoxide (TATP), ammonium nitrate, and sodium chlorate] were selected as representative target compounds. Quantities of these target compounds were deposited on four different substrates (glass, plastic, aluminium foil and laminate). Two chosen alcohol wipes demonstrated better overall performance in the recovery of both the organic and inorganic representative compounds from each of the test surfaces compared to the results obtained using conventional cotton and polyester swabs, pre-moistened with various solvents, and a direct methanol wash (used as a control). Results obtained using dry cotton swabs indicated that it was not an effective swabbing system for the collection of both organic and inorganic explosive residues on common substrates.  相似文献   

9.
二维气相色谱检测爆炸残留物中TNT   总被引:1,自引:0,他引:1  
目的建立二维气相色谱结合ECD检测爆炸残留物中TNT的方法。方法利用Dean-Switch系统进行二维无死体积切换,通过切换时间的准确选择,使粉尘样品提取液无需净化进样,即可达到分离彻底、高灵敏度。结果在案件检测应用中,效果良好。  相似文献   

10.
Abstract: A method is described to perform automated mapping of hexahydro‐1,3,5‐trinitro‐1,3,5‐triazine (RDX) particles in C‐4 fingerprints. The method employs polarized light microscopy and image analysis to map the entire fingerprint and the distribution of RDX particles. This method can be used to evaluate a large number of fingerprints to aid in the development of threat libraries that can be used to determine performance requirements of explosive trace detectors. A series of 50 C‐4 fingerprints were characterized, and results show that the number of particles varies significantly from print to print, and within a print. The particle size distributions can be used to estimate the mass of RDX in the fingerprint. These estimates were found to be within ±26% relative of the results obtained from dissolution gas chromatography/μ‐electron capture detection for four of six prints, which is quite encouraging for a particle counting approach. By evaluating the average mass and frequency of particles with respect to size for this series of fingerprints, we conclude that particles 10–20 μm in diameter could be targeted to improve detection of traces of C‐4 explosives.  相似文献   

11.
This study presents the rapid screening of various high grade explosives by high performance liquid chromatography (HPLC) with monolithic stationary phases. Two gradient methods were developed, the first for quantitative analysis of eleven explosives: HMX; RDX; Tetryl; TNT; 2,3-DNT; 2,6-DNT; 3,4-DNT; 2-NT; 3-NT; 4-NT; and PETN in under 14 min. The second method separated seven explosives in under two min and is suitable for rapid screening to determine the presence of specific and/or class of explosive. The rapid screening methods were successfully applied to soils spiked with known amounts of target explosives. This technology showed excellent potential for forensic explosives detection and analysis.  相似文献   

12.
Sampling of hair has proved to be a useful non-invasive method for detecting illicit drugs. This study examined the viability of hair as a surface from which explosive traces can be recovered and showed that as little as one-hour vapour exposure can result in measurable traces of explosives. Contamination of the hair may result from direct contact with explosive particles or from secondary contact by hand. Also the paper demonstrates that hair can concentrate explosive from the ambient vapour of a variety of military explosives. It was found that the amount of TNT picked up by the hair increased with time of vapour exposure. The data also suggested that unwashed hair may pick up more TNT than washed hair.  相似文献   

13.
Method detection limits are determined and compared for analysis of liquid injections of organic explosives and related compounds by gas chromatography-mass spectroscopy utilizing electron impact (EI), negative ion chemical ionization (NICI), and positive ion chemical ionization (PICI) detection methods. Detection limits were rigorously determined for a series of dinitrotoluenes, trinitrotoluene, two nitroester explosives, and one nitramine explosive. The detection limits are lower by NICI than by EI or PICI for all explosives examined, with the exception of RDX. The lowest detection limit for RDX was achieved in the PICI ionization mode. Judicious choice of the appropriate ionization mode can enhance selectivity and significantly lower detection limits. Major ions are reported for each analyte in EI, PICI, and NICI detection modes.  相似文献   

14.
Quantification and aging of the post-blast residue of TNT landmines   总被引:4,自引:0,他引:4  
Post-blast residues are potential interferents to chemical detection of landmines. To assess the potential problem related to 2,4,6-trinitrotoluene (TNT), its post-blast residue was identified and quantified. In the first part of this study laboratory-scale samples of TNT (2 g) were detonated in a small-scale explosivity device (SSED) to evaluate the explosive power and collect post-blast residue for chemical analysis. Initiator size was large relative to the TNT charge; thus, issues arose regarding choice of initiator, residue from the initiator, and afterburning of TNT. The second part of this study detonated 75 to 150 g of military-grade TNT (typical of antipersonnel mines) in 55-gal barrels containing various witness materials (metal plates, sand, barrel walls, the atmosphere). The witness materials were analyzed for explosive residue. In a third set of tests, 75-g samples of TNT were detonated over soil (from Fort Leonard Wood or Sandia National Laboratory) in an indoor firing chamber (100 by 4.6 by 2.7 m high). Targeted in these studies were TNT and four explosive-related compounds (ERC): 2,4-dinitrotoluene (DNT), 1,3-dinitrobenzene (DNB), 2- and 4-aminodinitrotoluene (2-ADNT and 4-ADNT). The latter two are microbial degradation products of TNT. Post-blast residue was allowed to age in the soils as a function of moisture contents (5 and 10%) in order to quantify the rate of degradation of the principal residues (TNT, DNT, and DNB) and formation of the TNT microbial degradation products (2-ADNT and 4-ADNT). The major distinction between landmine leakage and post-blast residue was not the identity of the species but relative ratios of amounts. In landmine leakage the DNT/TNT ratio was usually greater than 1. In post-blast residue it was on the order of 1 to 1/100th of a percent, and the total amount of pre-blast residue (landmine leakage) was a factor of 1/100 to 1/1000 less than post-blast. In addition, landmine leakage resulted in low DNT/ADNT ratios, usually less than 1, whereas pre-blast residues started with ratios above 20. Because with time DNT decreased and ADNT increased, over a month the ratio decreased by a factor of 2. The rate of TNT degradation in soil observed in this study was much slower than that reported when initial concentrations of TNT were lower. Degradation rates yielded half-lives of 40 and 100 days for 2,4-DNT and TNT, respectively.  相似文献   

15.
The sizes of explosives particles in fingerprint residues produced from C-4 and Semtex-1A were investigated with respect to a fragmentation model. Particles produced by crushing crystals of RDX and PETN were sized by using scanning electron microscopy, combined with image analysis, and polarized light microscopy was used for imaging and identifying explosive particles in fingerprint residues. Crystals of RDX and PETN fragment in a manner that concentrates mass in the largest particles of the population, which is common for a fragmentation process. Based on the fingerprints studied, the particle size to target for improving mass detection in fingerprint residues by ion mobility spectrometry (IMS) is > or = 10 microm in diameter. Although particles smaller than 10 microm in diameter have a higher frequency, they constitute < 20% of the total mass. Efforts to improve collection efficiency of explosives particles for detection by IMS, or other techniques, must take into consideration that the mass may be concentrated in a relatively few particles that may not be homogeneously distributed over the fingerprint area. These results are based on plastic-bonded explosives such as C-4 that contain relatively large crystals of explosive, where fragmentation is the main process leading to the presence of particles in the fingerprint residues.  相似文献   

16.
目的 建立X射线衍射法(XRD)检验有机炸药的方法.方法 使用X射线衍射仪对有机炸药苦味酸(PA),太安(PTEN),黑索金(RDX),梯恩梯(TNT)进行测试分析.结果 准确测定出有机炸药的物质组成及结构.结论 该方法能够直接给出有机炸药的分子式及结构组成,定性准确,操作简便,可用于有机炸药的定性检测.  相似文献   

17.
The use of a direct analysis in real time (DART) mass spectrometer (MS) instrument was optimized for 22 compounds of organic explosive residues to provide a guide for DART‐MS users in rapid screening of explosive compounds. Samples were introduced as neat solutions and sequential dilutions to determine optimal instrument conditions and lowest concentration detectable. Most compounds were optimized to 250°C in the negative ion mode, and several compounds benefited from the addition of a chloride dopant from methylene chloride (amino‐dinitrotoluenes, RDX, EGDN, and PETN). Few compounds were more sensitive in the positive ion mode (TEGDN, DEGDN, HNS, and DMNB). Mixtures of compounds were detected using clean room wipes, directly from their surfaces and from subsequent extractions. Compounds from the mixtures were also successfully detected in soil and from swipes of spiked surfaces. The instrument showed merit in detection of pg/μL solutions for most of the compounds and among the substrates tested.  相似文献   

18.
Biological stains can be difficult to detect at crime scenes or on items recovered from crime scenes. The use of a versatile light source may assist in their detection. The ability of Polilight to locate potential semen, saliva, and blood stains on a range of substrates and at different dilutions was tested. We also tested the use of Polilight in comparison with conventional chemical-based presumptive screening tests such as acid phosphatase (AP), Phadebas, and luminol, often used in casework for detecting potential semen, saliva, and blood stains, respectively. The Polilight was able to locate stains that were not apparent to the naked eye. The color of the material on which a stain is deposited can have an effect on the detectibility of the stain. The Polilight was found to be comparable with the AP and Phadebas tests in terms of its sensitivity. In a comparative study between the AP test and Polilight on 40 casework exhibits, one false-negative result was observed when using the Polilight. On a series of mock casework exhibits it was determined that the Polilight can be used successfully to locate saliva stains for DNA analysis. The sensitivity of luminol for detecting potential bloodstains was greater than that of Polilight; however the Polilight has particular application in instances where a bloodstain may have been concealed with paint. Overall, the Polilight is a relatively safe, simple, noninvasive, and nondestructive technique suitable for use in forensic casework.  相似文献   

19.
It is important to understand the extent of transfer of explosive particles to different surfaces in order to better evaluate potential cross-contamination by explosives in crowded security controls such as those at airports. This work investigated the transfer of nine explosive residues (ANFO, dynamite, black powder, TNT, HMTD, PETN, NH4NO3, KNO3, NaClO3) through fingerprints from one surface to another. First, the extent of adhesion of explosive residues from different surfaces to the bare finger, nitrile and latex gloves was studied. Then, the transfer of explosive residues from one surface to another through fingerprints was investigated. Cotton fabric (hereinafter referred to as cotton) as clothing material and polycarbonate plastic (hereinafter referred to as polycarbonate) as luggage material were chosen for the experiments. These surfaces containing explosive particles were imaged using a reflex camera before and after the particles were transferred. Afterwards the images were processed in MATLAB where pixels corresponding to explosive residues were quantified. Results demonstrated that transfer of explosive residues frequently occurred with certain differences among materials. Generally, the amount of explosive particles adhered to the finger decreased in the following order: skin>latex>nitrile, while the transfer of particles from the finger to another surface was the opposite. The adhesion of explosive residues from polycarbonate to the finger was found to be better compared to cotton, while the amount of particles transferred to cotton was higher.  相似文献   

20.
Detection of trace quantities of explosive residues plays a key role in military, civilian, and counter-terrorism applications. To advance explosives sensor technology, current methods will need to become cheaper and portable while maintaining sensitivity and selectivity. The detection of common explosives including trinitrotoluene (TNT), cyclotrimethylenetrinitramine, cyclotetramethylene-tetranitramine, pentaerythritol tetranitrate, 2,4,6-trinitrophenyl-N-methylnitramine, and trinitroglycerin may be carried out using a three-step process combining "turn-off" and "turn-on" fluorimetric sensing. This process first detects nitroaromatic explosives by their quenching of green luminescence of polymetalloles (lambda em approximately 400-510 nm). The second step places down a thin film of 2,3-diaminonaphthalene (DAN) while "erasing" the polymetallole luminescence. The final step completes the reaction of the nitramines and/or nitrate esters with DAN resulting in the formation of a blue luminescent traizole complex (lambda(em) = 450 nm) providing a "turn-on" response for nitramine and nitrate ester-based explosives. Detection limits as low as 2 ng are observed. Solid-state detection of production line explosives demonstrates the applicability of this method to real world situations. This method offers a sensitive and selective detection process for a diverse group of the most common high explosives used in military and terrorist applications today.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号