Liquid chromatography-mass spectrometry was used to identify and quantify the predominant capsaicinoid analogues in extracts of fresh peppers, in oleoresin capsicum, and pepper sprays. The concentration of capsaicinoids in fresh peppers was variable. Variability was dependent upon the relative pungency of the pepper type and geographical origin of the pepper. Nonivamide was conclusively identified in the extracts of fresh peppers, despite numerous reports that nonivamide was not a natural product. In the oleoresin capsicum samples, the pungency was proportional to the total concentration of capsaicinoids and was related by a factor of approximately 15,000 Scoville Heat Units (SHU)/microg of total capsaicinoids. The principle analogues detected in oleoresin capsicum were capsaicin and dihydrocapsaicin and appeared to be the analogues primarily responsible for the pungency of the sample. The analysis of selected samples of commercially available pepper spray products also demonstrated variability in the capsaicinoid concentrations. Variability was observed among products obtained from different manufacturers as well as from different product lots from the same manufacturer. These data indicate that commercial pepper products are not standardized for capsaicinoid content even though they are classified by SHU. Variability in the capsaicinoid concentrations in oleoresin capsicum-based self-defense weapons could alter potency and ultimately jeopardize the safety and health of users and assailants.  相似文献   

2.
A method was developed to screen for pepper spray residue using instruments and methods other than those techniques commonly employed to analyze chemical residue (i.e.. gas chromatography mass spectrometry-GCMS or liquid chromatography mass spectrometry-LCMS). The method employed gas chromatography (GC), thin layer chromatography (TLC), and diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) to screen for dried pepper spray stains. Pepper sprays from nine different manufacturers were investigated. Capsaicin and dihydrocapsaicin were identified and unique IR reflectance spectra are presented. An additional five compounds were presumptively found. Results showed that a particular stain could be characterized as a pepper-based stain.  相似文献   

3.
目的建立羟亚胺及氯胺酮定性和定量分析方法。方法分别使用气相色谱质谱联用法(GC/MS)、液相色谱质谱联用法(LC/MS)和液相色谱紫外法(LC/UV)分析羟亚胺,考察各方法的特点及适用范围。结果采用GC/MS法分析时,进样口的高温会导致部分羟亚胺转化为氯胺酮。LC/MS及LC/UV分析则不存在干扰,羟亚胺和氯胺酮的线性范围分别为3.0~300 ng/mL(LC/MS)、0.02~1.00mg/mL(LC/UV);最低检测限分别为1.0ng/mL(LC/MS)、5.0μg/mL(LC/UV)。结论 GC/MS法仅可确定样品中羟亚胺的存在,不能确认是否含有氯胺酮。LC/MS和LC/UV法可分别用于痕量和常量羟亚胺和氯胺酮定性和定量分析。  相似文献   

4.
Liquid chromatography/mass spectrometry (LC/ MS) and matrix assisted laser desorption/ionization time-of-flight (MALDI-TOF) MS methods were developed for the presumptive identification of ricin toxin and the alkaloid marker ricinine from crude plant materials. Ricin is an extremely potent poison, which is of forensic interest due to its appearance in terrorism literature and its potential for use as a homicide agent. Difficulties arise in attempting to analyze ricin because it is a large heterogeneous protein with glycosylation. The general protein identification scheme developed uses LC/MS or MALDI-TOF for size classification followed by the use of the same instrumentation for the analysis of the tryptic digest. Fragments of the digest can be searched in an online database for tentative identification of the unknown protein and then followed by comparison to authentic reference materials. LC fractionation or molecular weight cutoff filtration was used for preparation of the intact toxin before analysis. Extracts from two types of castor beans were prepared using a terrorist handbook procedure and determined to contain 1% ricin. Additionally, a forensic sample suspected to contain ricin was analyzed using the presented identification scheme (data not shown). The identification of the alkaloid ricinine by GC/MS and LC/MS was shown to be a complementary technique for the determination of castor bean extracts.  相似文献   

5.
Hair samples of patients of psychiatry and hair samples of suicide cases were analysed by liquid-chromatography/ionspray-mass spectrometry (LC/MS) for antidepressants and neuroleptics. Electrospray ionisation (ESI) with in-source collision induced dissociation (ESI/CID) and tandem-mass spectrometry (MS/MS) were used for drug and metabolite identification. Mass spectra library searching was performed using an ESI/CID mass spectra library and a MS/MS spectra library. Furthermore, extracted ion chromatograms were used for the detection of N-desmethyl-metabolites, which were also identified by their fragment-ion spectra. Three examples using these methods are shown: The tricyclic antidepressant maprotiline, the selective serotonin receptor inhibitor (SSRI) citalopram and their desmethylmetabolites as well as the neuroleptic pipamperone were detected and identified in hair extracts. For extraction powdered hair was treated by ultrasonication in methanol and solid-phase extraction was used for sample clean-up prior to LC/MS or MS/MS analysis. These examples demonstrate the power of LC/MS and LC/MS/MS for the detection and identification of drugs in hair extracts using full-scan mode and ESI/CID with library searching or using highly selective LC/MS/MS-analysis with library searching or in multiple reaction monitoring mode.  相似文献   

6.
A critical point of comparison between a fiber collected from a crime scene and a fiber from a known source is the color. Fiber dye analysis using thin-layer chromatography or ultraviolet (UV)-visible (Vis) microspectrophotometry provides useful, although limited, data for comparison. High-performance liquid chromatography-electrospray ionization mass spectrometry (LC/MS) overcomes these limitations by integrating chromatography, ultraviolet-visible spectroscopy, and mass spectrometry into a single instrument. In order to evaluate the applicability of the LC/MS to forensic fiber dye analysis, a multi-stage chromatographic method using acidified water and acidified acetonitrile was developed that separated and identified a mixture of 15 basic and 13 disperse dye standards. The LC/MS also detected and analyzed dyes extracted from individual 0.5 cm acrylic and polyester fibers, demonstrating its applicability to this type of analysis. With regard to the analysis of disperse dyes in polyester fibers, the replacement of pyridine with acetonitrile in the extraction system allowed direct injection of the extracts into the LC/MS. The advantage of the LC/MS over other instrumental methods of textile dye analysis is demonstrated by the analysis and differentiation of three black acrylic fibers: two fibers had similar UV-Vis spectra but were differentiated with chromatography and two had similar UV-Vis spectra and chromatograms but were differentiated using the mass spectrometer.  相似文献   

7.
A fast method using automated solid-phase extraction (SPE) and short-column liquid-chromatography coupled to tandem mass-spectrometry (LC/MS/MS) with negative atmospheric-pressure chemical ionisation (APCI) has been developed for the confirmation of 11-nor-9-carboxy-Delta(9)-tetrahydrocannabinol (THC-COOH) in urine samples. This highly specific method which combines chromatographic separation and MS/MS-analysis can be used for the confirmation of positive immunoassay results with a NIDA cut-off of 15ng/ml. The conjugates of THC-COOH were hydrolysed prior to SPE, and a standard SPE was performed using C18-SPE columns. No derivatisation of the extracts was needed as in GC/MS analysis, and the LC run-time was 6.5min by gradient elution with a retention time of 2.4min. Linearity of calibration was obtained in the range between 0 and 500ng/ml (correlation coefficient R(2)=0.998). Using linear regression (0-50ng/ml) the limit of detection (LOD) was 2.0ng/ml and the limit of quantitation (LOQ) was 5.1ng/ml; day-to-day reproducibility and precision were tested at 15 and 250ng/ml and were 13.4ng/ml+/-3.3% and 255.8ng/ml+/-4.5%, respectively.  相似文献   

8.
A rapid and sensitive LC/MS method was developed for the simultaneous analysis of N,N-dimethylamphetamine (DMA), N,N-dimethylamphetamine N-oxide (DMANO), methylamphetamine (MA) and amphetamine (A) in urine samples. Employing an Alltech C18 column for solid phase extraction followed by LC/MS analysis using an Alltech Platinum EPS C18 column with a mixture of ammonium formate (0.01 M, pH 3) and acetonitrile (77:23, v/v) as mobile phase at a flow rate of 0.2 mL/min, simultaneous identification and quantitation of A, MA, DMA and DMANO in urine can be achieved using a 5-min chromatographic run. The calibration ranges were 0.10-3.0 micro g/mL for DMANO, 0.05-3.0 micro g/mL for DMA and 0.05-5.0 micro g/mL for both MA and A. The intra-, inter-day precision and accuracy for all analytes, spiked at three different concentrations in quality control samples, were in the ranges of 1.7-8.6, 4.1-10.0, -11.6 to 12.9%, respectively. The newly developed method was applied to the analysis of urine samples obtained from 118 suspected MA/DMA abusers, with the presence of MA confirmed in their urine samples under the drug-use surveillance program. Of these 118 samples, 43 were found to contain DMANO and 11 with both DMANO and DMA.  相似文献   

9.
Abstract: Thin layer chromatography (TLC) is a technique that is commonly employed in the forensic drug analysis of pharmaceutical preparations. Detection is typically accomplished using various visualization spray reagents. Conventional gas chromatography–mass spectrometry (GC‐MS) analysis is typically performed to confirm the TLC results. Depending on the drugs tested and the instrument conditions required, this confirmation can take up to an hour to complete. Direct analysis in real time (DART?) is an ionization source, coupled to an accurate‐mass time‐of‐flight mass spectrometer that has the capability to ionize materials under ambient conditions. To streamline analysis, the combination of TLC with DART? detection is proposed to screen and subsequently identify drug compounds, all from the same TLC plate. DART? confirmations of TLC analyses take <10 min to complete and compare favorably to GC‐MS in sensitivity and selectivity. This study validates the use of TLC‐DART in the forensic identification of the components of several pharmaceutical preparations.  相似文献   

10.
A simultaneous determination of 20 antidepressant drugs (imipramine, amitriptyline, desipramine, trimipramine, nortriptyline, clomipramine, amoxapine, lofepramine, dosulepin, maprotiline, mianserin, setiptiline, trazodone, fluvoxamine, paroxetine, milnacipran, sulpiride, tandspirone, methylphenidate and melitracen) in human plasma was developed using LC/MS with sonic spray ionization (SSI) method. These drugs showed good separation and sensitivity by LC-MS using an Inertsil C-8 column with methanol:10mM ammonium acetate (pH 5.0):acetonitrile (70:20:10) as mobile phase at 0.10 mL/min at 35 degrees C. Solid-phase extraction of these drugs added to the human plasma was performed with an Oasis HLB cartridge column. Recovery and limit of detection of these drugs were between 69 and 102% and between 0.03 and 0.63 microg/mL, respectively. The present procedure offers an easier and more convenient screening method for antidepressants, and will be useful for forensic toxicology investigations.  相似文献   

11.
A fast method using liquid-liquid extraction and HPLC/tandem-mass spectrometry (LC/MS/MS) was developed for the simultaneous detection of 11-Nor-Delta(9)-tetrahydrocannabinol-9-carboxylic acid beta-glucuronide (THC-COOH-glucuronide) and 11-Nor-Delta(9)-tetrahydrocannabinol-9-carboxylic acid (THC-COOH) in urine samples. This highly specific method, which combines chromatographic separation and MS/MS analysis, can be used for the confirmation of positive immunoassay results even without hydrolysis of the sample or derivatisation of extracts. Liquid-liquid extraction was optimised: with ethylacetate/diethylether (1:1, v/v) THC-COOH-glucuronide and THC-COOH could be extracted in one step. Molecular ions of the glucuronide (MH(+), m/z 521) and THC-COOH (MH(+), m/z 345) were generated using a PE/SCIEX turboionspray source in positive ionisation mode; specific fragmentation was performed in the collision cell of an API 365 triple-quadrupole mass spectrometer and yielded major fragments at m/z 345 (for THC-COOH-glucuronide) and m/z 327 as well as m/z 299 for both cannabinoids. Chromatographic separation was performed using a reversed-phase C8 column and gradient elution with 0.1% formic acid/1 mM ammonium formate and acetonitrile/0.1% formic acid. Retention times were 22.2 min for the glucuronide and 26.8 min for THC-COOH. After enzymatic hydrolysis of urine samples with beta-glucuronidase/arylsulfatase (37 degrees C, 5 h), THC-COOH-glucuronide was no longer detectable by LC/MS/MS in urine samples. However, the THC-COOH concentration was increased. For quantitation of THC-COOH, THC-COOH-D(3) was added to the urine samples as internal standard prior to analysis. From the difference of THC-COOH in the native urine and urine after enzymatic hydrolysis, molar concentration ratios of THC-COOH-glucuronide/THC-COOH in urine samples of cannabis users were determined and found to be between 1.3 and 4.5.  相似文献   

12.
Presumptive tests for blood play a critical role in the examination of physical evidence and in the determination of subsequent analysis. The catalytic power of hemoglobin allows colorimetric reactions employing phenolphthalein (Kastle‐Meyer test) to indicate “whether” blood is present. Consequently, DNA profiles extracted from phenolphthalein‐positive stains are presumed to be from blood on the evidentiary item and can lead to the identification of “whose” blood is present. Crushed nodules from a variety of legumes yielded phenolphthalein false‐positive reactions that were indistinguishable from true bloodstains both in color quality and in developmental time frame. Clothing and other materials stained by nodules also yielded phenolphthalein false‐positive reactivity for several years after nodule exposure. Nodules from leguminous plants contain a protein (leghemoglobin) which is structurally and functionally similar to hemoglobin. Testing of purified leghemoglobin confirmed this protein as a source of phenolphthalein reactivity. A scenario is presented showing how the presence of leghemoglobin from nodule staining can mislead investigators.  相似文献   

13.
Although fentanyl and a small number of derivatives used for medical or veterinary procedures are well characterized, physiochemical properties have not been determined for many of the newer fentanyl analogs. Partition coefficients (Log P) were determined for 19 fentalogs using the shake-flask method and liquid chromatography–tandem mass spectrometry (LC–MS/MS). Experimentally determined partition coefficients were compared with computationally derived data using six independent software sources (ACD/LogP, LogKOWWIN v 1.69, miLogP 2.2, OsirisP, XLOGP 3.0, ALogPS 2.1). Fentalogs with a wide variety of structural modifications were intentionally selected, yielding Log P values ranging from 1.21 to 4.90. Comparison of experimental and computationally derived Log P values were highly correlated (R2 0.854–0.967). Overall, substructure-based modeling using fragmental methods or property-based topological approaches aligned more closely with experimentally determined Log P values. LC–MS/MS was also used to estimate pKa values for fentalogs with no previously reported data. Lipophilicity and pKa are important considerations for analytical detection and toxicological interpretation. In silico methods allow the determination of physicochemical information prior to certified reference materials being readily available for in vitro or in vivo studies. Computationally derived data can provide insight regarding physiochemical characteristics of future fentalogs and other classes of synthetic analogs that have yet to emerge.  相似文献   

14.
Analogs and derivatives of traditional illicit drugs are ever increasing in variety and creativity. Staying abreast of the new developments is a constant challenge for every forensic laboratory. Recently, a seizure from Australian Customs Service presented our laboratory with the designer cathinone 3,4-dimethylmethcathinone (3,4-DMMC). Gas chromatography/mass spectrometry (GC/MS), liquid chromatography/mass spectrometry (LC/MS), nuclear magnetic resonance (NMR) spectroscopy, infrared (IR) spectroscopy, and ultraviolet (UV) spectrophotometry were employed to analyze the spectroscopic characteristics of this cathinone. As an analog, 3,4-DMMC exhibits similar if not identical IR and UV profiles to mephedrone (4-MMC) and methcathinone; however, the retention time from GC is unique as expected, and the electron impact fragmentation pattern is consistent with the fragmentation pattern of other cathinones. The chemical shifts of the carbons and hydrogens were assigned by both one- and two-dimensional NMR techniques, while the molecular weight was confirmed by LC/MS.  相似文献   

15.
A rapid and sensitive liquid chromatography/electrospray ionization mass spectrometry (LC/MS) procedure has been developed for the analysis of biofluids containing flunitrazepam and its metabolites. Specimens were spiked with deuterated analogs of the analytes. Urine specimens were enzymatically hydrolyzed and blood specimens were untreated. Extractions were carried out using CleanScreen DAU SPE cartridges. The drugs were separated on a C18 column using a methanol-water-ammonium hydroxide (60:40: 0.03 v/v) mobile phase. After determination of base peaks using full scan mass spectrometry, the mass spectrometry method was optimized to operate in selected-ion monitoring (SIM) mode for the base peak of each analyte. Positive findings were confirmed by LC/MS/MS using the same mobile phase and column. This analytical procedure allows for the detection of low levels of flunitrazepam and metabolites in biofluids. It is useful for ascertaining the role of flunitrazepam in cases of drug-facilitated sexual assault.  相似文献   

16.
Toxicological and forensic medical characteristics of capsaicinoids are presented. Capsaicinoids represent a mixture of three basic compounds with similar structure: capsaicine, dihydrocapsaicine, and nordihydrocapsaicine, all of which are the primary components of red pepper extract (Oleoresin Capsicum). The advantages of this group of irritants in comparison with synthetic irritants are discussed. Probable routes of administration of the extract with regard to its hazard for the organism are considered. Results of experimental studies on nonbiological phantoms and volunteers are presented.  相似文献   

17.
The following report summarizes a study performed on seized drug exhibits collected in two U.S. states to evaluate the presence and identification of cutting agents. Aliquots of seized drug materials from Kentucky (n = 200) and Vermont (n = 315) were prepared using a dilute‐and‐shoot procedure. Initial analysis was performed using gas chromatography–mass spectrometry (GC‐MS) followed by analysis using liquid chromatography quadrupole time‐of‐flight mass spectrometry (LC‐QTOF). Active compounds detected overall included caffeine (31.0%), quinine/quinidine (24.7%), levamisole (11.6%), acetaminophen, (8.2%) and procaine (8.2%). These compounds were found with several drugs of abuse, such as heroin, fentanyl, methamphetamine, and cocaine. This novel information about cutting agents used to dilute or alter drugs of abuse is important to criminal investigations and in the management of acute intoxications at health centers. However, common methodologies for analysis and standard reporting practices frequently do not include cutting agents, resulting in lacking or inadequate information regarding prevalence of these substances.  相似文献   

18.
Hypertension is a growing medical concern in the United States. With the number of Americans suffering from hypertension increasing, the use of antihypertensives such as beta-blockers is increasing as well. In fact, three beta-blockers - atenolol, metoprolol and propranolol - were among the 200 most prescribed medications in the United States in 2003. Pilots that successfully manage their hypertension can remain certified to fly. The Federal Aviation Administration currently designates approximately 8% of active pilots as "hypertensive with medication". The Civil Aerospace Medical Institute (CAMI) performs toxicological evaluation on victims of fatal aviation accidents. At CAMI beta-blockers are analyzed using gas chromatography with mass spectrometric detection. We have, however, recently developed a liquid chromatography with mass spectrometric detection (LC/MS) method for the simultaneous quantitation of three commonly prescribed beta-blockers, atenolol, metoprolol and propranolol. One advantage of our LC/MS method is the specificity provided by an ion trap MS. Utilizing an ion trap MS, we were able to conduct MS/MS and MS/MS/MS on each analyte. This method also eliminates the time-consuming and costly derivitization step necessary during GC/MS analysis. Additionally, by utilizing this novel method, any concerns about beta-blocker metabolite and/or sample matrix interference are eliminated. The limits of detection for this method ranged from 0.39 to 0.78 ng/mL and the linear dynamic range was generally 1.6-3200 ng/mL. The extraction efficiencies for each analyte ranged from 58% to 82%. This method was successfully applied to postmortem fluid and tissue specimens obtained from victims of three separate aviation accidents.  相似文献   

19.
Abstract:  Current methods for forensic identification of saliva generally assay for the enzymatic activity of α-amylase, an enzyme long associated with human saliva. Here, we describe the R apid S tain ID entification (RSID™-Saliva), a lateral flow immunochromatographic strip test that uses two antisalivary amylase monoclonal antibodies to detect the presence of salivary amylase, rather than the activity of the enzyme. We demonstrate that RSID™-Saliva is accurate, reproducible, and highly sensitive for human saliva; RSID™-Saliva detects less than 1 μL of saliva. The sensitivity of RSIDTM-Saliva allows investigators to sample a fraction of a questioned stain while retaining the majority for DNA-STR analysis. We demonstrate that RSID™-Saliva identifies saliva from a variety of materials (e.g., cans, bottles, envelopes, and cigarette-butts) and it does not cross-react with blood, semen, urine, or vaginal fluid. RSID™-Saliva is a useful forensic test for determining which evidentiary items contain saliva and thus may yield a DNA profile.  相似文献   

20.
Specimens from fatal aviation accident victims are submitted to the FAA Civil Aerospace Medical Institute for toxicological analysis. During toxicological evaluations, ethanol analysis is performed on all cases. Care must be taken when interpreting a positive ethanol result due to the potential for postmortem ethanol formation. Several indicators of postmortem ethanol formation exist; however, none are completely reliable. The consumption of ethanol has been shown to alter the concentration of two major serotonin metabolites, 5-hydroxytryptophol (5-HTOL) and 5-hydroxyindole-3-acetic acid (5-HIAA). While the 5-HTOL/5-HIAA ratio is normally very low, previous studies using living subjects have demonstrated that the urinary 5-HTOL/5-HIAA ratio is significantly elevated for 11-19 h after acute ethanol ingestion. Recently, our laboratory developed and validated an analytical method for the simultaneous determination of both 5-HTOL and 5-HIAA in forensic urine samples using a simple liquid/liquid extraction and LC/MS/MS and LC/MS/MS/MS. In this previous work a 15 pmol/nmol serotonin metabolite ratio cutoff was established in postmortem urine, below which it could be conclusively determined that no recent antemortem ethanol consumption had occurred. In the current study this newly validated analytical method was applied to five ethanol-positive aviation fatalities where the origin of the ethanol present could not previously be conclusively determined. In four of the five cases examined the detected ethanol was demonstrated to be present due to postmortem microbial formation, and not consumption, even though some indication of ethanol consumption may have been present.  相似文献   