首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 722 毫秒
1.
Fifteen metallic species, silver (Ag), aluminum (Al), calcium (Ca), cadmium (Cd), chromium (Cr), copper (Cu), iron (Fe), potassium (K), magnesium (Mg), manganese (Mn), sodium (Na), nickel (Ni), lead (Pb), strontium (Sr) and zinc (Zn), were determined in 46 cocaine samples confiscated by the Spanish police in Galicia (northwest Spain). Classification of these cocaine samples according to their geographic origin (Colombia and Venezuela) was achieved by the application of pattern recognition techniques to the metallic content data. Cocaine samples, around 0.5 g, were directly dissolved in 2 mL of 35.0% (v/v) HNO3, diluted to 10 mL with ultrapure water. The metals were quantified by means of electrothermal atomic absorption spectrometry (Ag, Al, Cd, Cr, Cu, Mn, Ni, Pb and Sr), flame atomic absorption spectrometry (Ca, Fe, Mg and Zn), and flame atomic emission spectrometry (K and Na). Results show that two geographic origins can be established through the presence of trace and major elements.  相似文献   

2.
This research studied accumulation of heavy metals in soil and three plant species in E-waste dumpsite in Kalasin Province, Thailand. DNA changes in the plants were accessed by DNA fingerprinting and genomic template stability (GTS) analyses. Concentrations of the metals were in the order of Zn > Pb > Cd > Cr. The Bioconcentration Factor (BCF), Translocation Factor (TF), and Enrichment Factor (EF) values showed that Typha angustifolia was suitable for phytoremediation of Cd, Pb, and Zn. However, after the process of phytoremediation, appropriate abolishment of the heavy-metal containing plants should be taken to prevent the metals from passing along the food web. The GTS values ranged from 54.23 to 69.35%. These results suggest that heavy metals have affected the genotoxicity of plants grown in the electronic waste dumpsite.  相似文献   

3.
目的应用扫描电镜/能谱联合分析仪(Scanning electron microscopy&Energy dispersive X-ray apparatus SEM/EDX)和电感耦合原子发射等离子光谱(inductively coupled plasma-atom emission spectrometer ICP-AES)对金属致伤工具本身及所致创口残留物元素成分分析,探讨两者在推断认定此类工具的应用条件及价值。方法镀层和普通铁质工具在乳猪皮肤各致创5例,SEM/EDX对创口内遗留金属颗粒元素检测;用标准样品检测实验方法的精确度;普通铁质工具于刀背、刀刃处各取5个样本,ICP-AES测定元素成分与含量。结果镀锌工具所致创口中存在单一含有锌的金属颗粒,镀黄铜工具则同时含有锌和铜,未发现其它元素;不锈钢或普通铁质菜刀创口中,发现同时含有铁、铬、硅或铁、锰、硅的颗粒;除5号菜刀外同一把铁质菜刀在刀刃、刀背处元素含量无明显差别;ICP-AES分析表明不锈钢菜刀之间在铬、锰、硅、铜、钼和5号刀背部以及其他铁质菜刀在锰、硅元素含量差别具有显著意义,5号刀刃部锰、硅、钼、钛、磷、硫、镍元素RSD明显升高。结论SEM/EDX可以通过创口的检测对金属致伤工具进行种类的推断认定,ICP-AES则可在同种类致伤工具中进行相对同一的判定有应用价值。  相似文献   

4.
应用SEM/EDX和ICP-AES检测元素成份判定致伤工具   总被引:1,自引:1,他引:0  
目的应用扫描电镜/能谱联合分析仪(Scanning electron microscopy & Energy dispersive X-ray apparatus SEM/EDX)和电感耦合原子发射等离子光谱(inductively coupled plasma-atom emission spectrometer ICP-AES)对金属致伤工具本身及所致创口残留物元素成分分析,探讨两者在推断认定此类工具的应用条件及价值.方法镀层和普通铁质工具在乳猪皮肤各致创5例,SEM/EDX对创口内遗留金属颗粒元素检测;用标准样品检测实验方法的精确度;普通铁质工具于刀背、刀刃处各取5个样本,ICP-AES测定元素成分与含量.结果镀锌工具所致创口中存在单一含有锌的金属颗粒,镀黄铜工具则同时含有锌和铜,未发现其它元素;不锈钢或普通铁质菜刀创口中,发现同时含有铁、铬、硅或铁、锰、硅的颗粒;除5号菜刀外同一把铁质菜刀在刀刃、刀背处元素含量无明显差别;ICP-AES分析表明不锈钢菜刀之间在铬、锰、硅、铜、钼和5号刀背部以及其他铁质菜刀在锰、硅元素含量差别具有显著意义,5号刀刃部锰、硅、钼、钛、磷、硫、镍元素RSD明显升高.结论SEM/EDX可以通过创口的检测对金属致伤工具进行种类的推断认定,ICP-AES则可在同种类致伤工具中进行相对同一的判定有应用价值.  相似文献   

5.
Ten elements, aluminum (Al), barium (Ba), calcium (Ca), cadmium (Cd), copper (Cu), iron (Fe), magnesium (Mg), manganese (Mn), lead (Pb), and zinc (Zn) were analyzed in 44 illicit heroin samples from Southeast Anatolia, Turkey. Illicit heroin samples were dissolved in nitric acid using microwave oven and were quantified by electrothermal atomic absorption spectrometry (Cd and Pb) and inductively coupled plasma-atomic emission spectrometry (Al, Ba, Ca, Cu, Fe, Mg, Mn, and Zn). The most abundant element was calcium, 4050 to 14,200 microg/g, which could be ascribed to the use of lime in the manufacturing process and/or as diluting agent. Iron (180 to 1470 microg/g), aluminum (42 to 2280 microg/g), and zinc (160 to 210 microg/g) were found at moderately high levels, possibly because of the use of metal pots in the acetic anhydride cooking process and also for storage. Cadmium and lead concentrations were at the lowest measured levels. The amounts of magnesium, manganese, barium, and copper were in the range of 100 to 800 micro/g, 3 to 17 microg/g, 4 to 30 microg/g, and 2 to 46 microg/g, respectively.  相似文献   

6.
A table has been created, presenting normal levels of heavy metals (Hg, Cd, Cr, Cu, Fe, Mn, Pb, Ni, Zn, Sn, Tl, Ag) in human biological media. In contrast to other handbooks, the authors use the normal values derived on the basis of their own investigations at the spectral laboratory of Bureau of Forensic Medical Expert Evaluations, Public Health Committee of Moscow and published reports. Comparative analysis was carried out for each element in human organs, tissues, and urine, which will facilitate expert work. Every laboratory engaged in expert evaluations and analysis in cases with suspected poisoning with heavy metal salts is to have reference values of these elements' concentrations in human organs and tissues obtained in this very laboratory on available equipment with consideration for specific features of its biogeochemical region.  相似文献   

7.
An ultrasound-assisted extraction method is proposed for the determination of trace elements in hair samples by inductively coupled plasma-mass spectrometry (ICP-MS) for forensic investigation. Prior to analysis, 25 mg of hair samples were accurately weighed into (15 mL) conical tubes. Then, 2 mL of 20% HNO3 is added to the samples, sonicated at 2 min (50 W, 100% amplitude), and then further diluted to 10 mL with Milli-Q water. Resulted diluted slurries are centrifuged and the analytes are directly determined in the supernatant. Calibrations against aqueous solutions were carried out with rhodium as internal standard. The method was successfully applied for the extraction of Al, As, Ba, Be, Cd, Co, Cr, Cu, Mn, Pb, Tl, U, V and Zn with a method detection limit (3 s, n = 20) of 0.1, 0.4, 0.2, 0.09, 0.08, 0.04, 0.1, 2.9, 1.0, 0.9, 0.04, 0.05, 0.1 and 4.2 ng/g, respectively. Method accuracy is traceable to Certified Reference Materials (CRMs) 85 and 86 human hair from the International Atomic Energy Agency (IAEA). Additional validation data are provided based on the analysis of hair samples from the trace elements intercomparison program operated by the Institut National de Sante’ Publique du Quebec, Canada. The proposed method is very simple and can be applied for forensic purposes with the elimination of sample digestion step prior to analysis. Then, a considerable improvement in the sample throughput is archived with the use of the proposed method.  相似文献   

8.
电感耦合等离子体质谱法检测电流损伤皮肤中金属元素   总被引:2,自引:0,他引:2  
目的探讨应用电感耦合等离子体质谱(inductively coupled plasma mass spectrometry,ICP-MS)技术检测电流损伤皮肤中金属元素的可行性,建立检测电流损伤皮肤中金属元素的方法。方法用黄铜、紫铜、铝、铁电极材料以220V交流电电击家兔后肢,ICP-MS对电流损伤皮肤中金属元素进行检测。结果与对照组比较:黄铜电击组皮肤中的Cr、Ni、Cu、Zn、Pb含量升高(P0.05),紫铜电击组皮肤中的Cr、Cu、Pb含量升高(P0.05),铝电击组皮肤中的Al、Cr、Mn、Co、Ni、Cu、Pb含量升高(P0.05),铁电击组皮肤中的Cr、Mn、Fe、Ni含量升高(P0.05)。不同电极材料电击后皮肤中元素种类及含量也存在明显差异。结论ICP-MS可作为检测电流损伤皮肤中金属元素的有效方法,且可应用于触电材料的推断。  相似文献   

9.
Four multi-elementary metal and metalloid quantification methods using inductively coupled plasma mass spectrometry (ICP-MS) were developed and validated in human whole blood, plasma, urine and hair by means of a single preparation procedure for each sample. The ICP-MS measurements were performed using a Thermo Elemental X7CCT series and PlasmaLab software without a dynamic reaction cell. With this procedure 27-32 elements can be simultaneously quantified in biological matrices: Li, Be, B, Al, V, Cr, Mn, Co, Ni, Cu, Zn, Ga, Ge, As, Se, Rb, Sr, Mo, Pd, Ag, Cd, Sn, Sb, Te, Ba, W, Pt, Hg, Tl, Pb, Bi, U. Whole blood, plasma and urine samples (0.4 ml each) were diluted with purified water, acid, triton X100 and butanol. Rhodium was used as internal standard. The urine sample results were corrected for enzymatic creatinine determination. Twenty-five milligrams hair samples were acid mineralized after a decontamination procedure and diluted as previously described for biological fluids. To be validated, each element had to show linearity with a correlation coefficient higher than 0.99. The intra-assay and inter-assay inaccuracy, measured as the variation coefficient, were below 5 and 10% respectively. Global performance was assessed by a quality control program. Our laboratory is a registered participant of the Institut National de Santé Publique du Québec (Sainte-Foy, Canada) inter-laboratory comparison program for whole blood, urine, and beard hair of non-occupationally exposed individuals spiked with selected elements. In our study multi-element metal and metalloid analysis was assessed for 27 elements in whole blood, 27 elements in plasma, 30 elements in urine and 32 elements in hair, from 0 to 25, or 250 to 1000 ng/ml, depending on the element. Quantification limits ranged from 0.002 ng/ml (U) to 8.1 ng/ml (Al) for whole blood, from 0.002 ng/ml (U) to 7.7 ng/ml (Al) for plasma, from 0.001 ng/ml (U) to 2.2 ng/ml (Se) for urine, and from 0.2 pg/mg (Tl) to 0.5 ng/mg (B) for hair. Normal values were determined in whole blood (n=100), plasma (n=100), urine (n=100), and hair (n=45) of healthy volunteers, leading to approximately 10,000 analyses. All results are presented and discussed. Clinical toxicology and forensic toxicology applications are also reported. ICP-MS has made significant advances in the field of clinical biology, particularly in toxicological analysis. This is due to the use of extremely effective equipment that permits better clinical and forensic toxicological analysis of metal and metalloid status of each individual patient.  相似文献   

10.
Metals, alloys, and poisoned food were analyzed with a hand-held X-ray fluorescence (XRF) spectrometer, with a shield (wrapping or casing material) inserted between these objects and the spectrometer, in order to examine the possibility of analyzing the contents of packages. Elements such as Fe, Cr, Ni, Cu, Zn, Pb, Mo, and As were detected in the objects. The fluorescent intensity of each element in the object decreased exponentially as the thickness of the shield increased, and the degree of decrease depended on both the material of the shield and the energy of fluorescent X-rays. The thickness of the shield can be calculated by using the intensity ratio Fe Kbeta/Kalpha or Pb Lbeta/Lalpha when the object is iron or lead, or by using the intensity of the Compton scattering of incident X-rays. The original peak intensity, i.e. intensity without a shield, of an element in an object can be estimated with the thickness of the shield obtained. Because the original peak intensity is calculated using an exponential function of the thickness of the shield, calculation of the intensity ratio, e.g. Zn Kalpha/Cu Kalpha for brass, is effective for cancelling the estimation error for the thickness of the shield. The composition of brass and steel can be estimated with an error of less than 30% by using the intensity of the Compton scattering.  相似文献   

11.
Teeth are recently drawing attention for their potential as biological modeling investigation samples due to their ability to be collected and their slow substance metabolism. There is no active metabolism of elements after the completion of dentin. Dentin is surrounded by enamel and cementum, and is not affected by the oral environment. Therefore, the amount of trace elements in dentin may change with age, and this is considered to be a reliable biological load index. The objectives in this study are to demonstrate concentrations of elements in the dentin of healthy Japanese subjects by sex and age, and to reveal the relationship between element levels and age. 121 healthy teeth samples were extracted due to periodontal disease or orthodontic treatment. Each tooth was sliced from the crown to the root apex into 0.5-1mm thickness, then enamel, cementum, and the pulp were removed; the dentins were used as samples. The concentration of 10 trace elements (B, Mn, Co, Cu, Zn, Rb, Sr, Mo, Cd, and Pb) in the dentin was measured using inductively coupled plasma mass spectrometer (ICP-MS). The differences Co and Pb in the dentin between men and women were significant (p<0.01). Significant positive correlation was observed between B, Co, Cu, Zn, Sr and Pb concentrations in the dentin and age (p<0.001). The results of the present study suggest that human dentin is an appropriate substance for relativity with sex and age at further future research.  相似文献   

12.
Identification particles used for the purpose of the post-blast identification of explosives have a coding system based on the combination of metal oxides and their various concentrations. These materials are composed of the polymeric matrix, iron powder (ferromagnetic properties), UV light active dyestuff and various metal oxides in a various ratios. A suitable analytical method has to be used for an accurate characterization of these metal components in the particles in order to find the required information, i.e. to determine the place and the year of production and as the case may be, also the production batch of misused explosives. In this work, the method of microwave digestion and flame atomic absorption spectrometry (F-AAS) was developed for an accurate determination of Zn, Mg, Cu and Pb in a few novel types of identification particles and applied to their characterization. When using specific sample treatment (digestion with a mixture of nitric acid with hydrochloric or hydrofluoric acid), the 3 sigma limits of detection (LODs) for the determination of Zn, Mg, Cu and Pb in 5mg original samples were 1.9, 0.2, 1.3 and 2.4 mg g(-1), respectively. The signal suppression due to the presence of HNO3+HCl or HNO3+HF was observed for Zn; therefore, the calibration solutions had to be prepared exactly with the same acids as those used for the sample mineralization. The determination of Mg, Cu and Pb was free of interferences; hence a simple calibration curve method could be adopted for attaining accurate results. The accuracy was checked by comparison of the results with those obtained by means of independent inductively coupled plasma optical emission spectrometry (ICP-OES). Good precision values, as relative standard deviation, in the range of 1-5% were obtained. A total number of 71 samples was analysed and classified by multivariate methods to prove the suitability of the procedure proposed for the purpose of the identification of explosives.  相似文献   

13.
This study investigates the connection between the results of DNA quantification with Quantifiler Human DNA Quantification Kit (AB) and DNA profiling. For this purpose the DNA concentration of 3.068 routine casework samples was determined and DNA profiling was carried out. For discussion, depending on the specific DNA concentration, the samples were divided into four groups (0–5, 5–10, 10–30 and more then 30 pg/μl DNA) and the obtained number of full or partial profiles and the negative typing results was listed. Moreover group 1 (0–5 pg/μl DNA) results were subdivided and analysed more precisely. Based on the amount of 4% positive typing results in group 1 we decided to analyse every sample with quantification results >0 pg/μl DNA. A real cut-off no longer exists. Only samples showing 0 pg/μl on each result were sorted out.  相似文献   

14.
It is well known that a toxic effect of some medicines is the result of their in vivo interactions with trace elements leading to disturbance of trace element balance in the living body. The Mossbauer spectrometry technique has been used for toxicochemical evaluation of iron-bearing medicines. This method can be used in forensic toxicology. We studied composition of trace elements in the hair of children living in Macedonia: in polluted territory (the town of Veles, the study group) versus in unpolluted one (Ivankovci village, the control group). AES-ICP and ICP-MS techniques were used. We discovered that the hair of children living in the polluted territory contain significantly elevated concentrations of Pb (in 43% cases), Hg, Ni (14%), Cd (21%), Cu (16%), Sn, As, Na, Se and subnormal concentrations of Mg (in 51% cases), Mn, Cr and Li.  相似文献   

15.
目的确立华东典型沿海地区浙江省三门县一般人群血液和尿液中33种元素(Ag、Al、As、Au、B、Ba、Be、Ca、Cd、Co、Cr、Cs、Cu、Fe、Ga、Hg、Li、Mg、Mn、Mo、Ni、Pb、Rb、Sb、Se、Sr、Th、Ti、Tl、U、V、Zn和Zr)的正常值参考范围。方法采用电感耦合等离子体质谱法检测272例血液样本和300例尿液样本中33种元素。采用SPSS 17.0软件对所得数据进行正态性检验,将所得数据与已有文献报道进行对比。结果建立了三门县一般人群血液和尿液中33种元素的正常值参考范围,其中Co、Cu、Mn和Sr等元素的正常值参考范围与其他报道相似,而As、Cd、Hg和Pb与其他研究报道存在差异,一般为高于其他报道,而血液中的Ba元素在各国文献报道之间差异较大。结论建立了三门县人群血液和尿液中33种元素的正常值参考范围,并成功应用于两例中毒案例的检测。  相似文献   

16.
The forensic investigator is frequently confronted with the discrimination and deduction of injury implements, which is one of the most important physical testimonies in courts. The usual method used in actual cases is from points of morphology. In the forensic discrimination of injury implements, such as metal implements, the analysis and comparison of elements are expected to provide excellent results, and simultaneous multi-elemental analysis is required to analyze various kinds of elements. This study was designed to establish discrimination and deduction of metal injury implements by scanning electron microscope/energy disperse X-ray microanalyzer (SEM/EDX) and inductively coupled plasma atomic emission spectrometry (ICP-AES). Examined metal particles in five wounds made on the skin of domestic pigs, respectively, using Cu-Zn or Cr-Ni coated and carbon steel kitchen implements by EDX. For carbon steel kitchen implements, analyzed five samples from the back and blade separately in the contents and varieties of elements by ICP-AES. In the wounds by the coated implements, the special particles only containing Cu, Zn or Cr, Ni were found. In the wounds by carbon steel kitchen implements, the particles containing Fe, Cr, Si or Fe, Mn, Si were found. The differences of contents of elements between the back and blade was no significant except No. 5 for carbon steel kitchen implements, and the significant differences of elements exited in Cr, Mn, Si, Cu, Mo among the stainless kitchen knives, Mn, Si among the other kitchen implements and for the blade of No. 5 knife, relative standard deviations (R.S.D.s) were significantly different in Mn, Si, Mo, Ti, S, P, Ni. Using EDX to examine the particles in wounds can deduce the categories of metal injury implements, and we can still deduce the different implements in the same category by ICP-AES.  相似文献   

17.
Abstract: During aviation accident investigations, vitreous fluid and urine samples from pilot fatalities are analyzed for glucose and blood for hemoglobin A1c (HbA1c) to monitor diabetic pilots and to discover other pilots with undiagnosed/unreported diabetes. The prevalence of elevated glucose concentrations in fatally injured pilots was evaluated by searching the Civil Aerospace Medical Institute’s Toxicology Database for the period 1998–2005. Out of 1335 pilots involving 363 vitreous fluid, 365 urine, and 607 vitreous fluid and urine analyses, 43 pilots had elevated glucose in vitreous fluid (>125 mg/dL) and/or in urine (>100 mg/dL). Of the 20 pilots whose blood samples were analyzed, nine had >6% HbA1c—four were known diabetics, and five were unknown diabetics. Urinary glucose levels were elevated in all 13 known hyperglycemic pilots. A considerable number of pilots (30 of 43) had elevated glucose and HbA1c (5 of 20), suggesting undiagnosed/unreported diabetic conditions.  相似文献   

18.
Cyanide is a highly toxic agent that has been frequently used for suicide in South Korea. It is also used in various industrial fields, such as metal plating, in which many accidental cyanide intoxications have occurred. To overcome the disadvantages of conventional cyanide analysis methods, a simple and fast method for the analysis of cyanide in whole blood using ion chromatography (IC) with amperometric detection was developed in this study. Whole blood samples were deproteinized, diluted, and analyzed using an IC–amperometric detection system. The limits of detection and quantitation were 0.1 and 0.2 mg/L, respectively. The method showed good linearity in the range of 0.2 to 50 mg/L with R2 > 0.99. The intra- and inter-assay precision and accuracy values were <10%. The established method was successfully applied to analyze whole blood samples from three cyanide intoxication cases.  相似文献   

19.
Counterfeit coins (277 samples) were analyzed by both X-ray diffraction (XRD) and X-ray fluorescence (XRF) methods without any pretreatment. The counterfeit coins were clearly classified into two groups using cluster analysis (CA) and principal component analysis (PCA) for XRD peak patterns. One group (250 samples) was made by a pressed method and another one (27 samples) was made by a nickel-plated method. Using four elements (Cu, Ni, Fe and Zn) and obtaining XRF for 257 samples, they could be divided into four groups by CA. On the other hand, they were classified into five groups using their diameter, thickness, weight, density, density/thickness and density/weight. The latter classification method would suggest something of a change in the process of the pressed method.  相似文献   

20.
Post-mortem drug redistribution--a toxicological nightmare   总被引:4,自引:0,他引:4  
Detailed human case data is presented to illustrate the dramatic extent of the phenomenon of post-mortem drug redistribution. The data suggests that there is a post-mortem diffusion of drugs along a concentration gradient, from sites of high concentration in solid organs, into the blood with resultant artefactual elevation of drug levels in blood. Highest drug levels were found in central vessels such as pulmonary artery and vein, and lowest levels were found in peripheral vessels such as subclavian and femoral veins. In individual cases, in multiple blood samples obtained from ligated vessels, concentrations of doxepin and desmethyldoxepin ranged from 3.6 to 12.5 mg/l and 1.2 to 7.5 mg/l, respectively; amobartital, secobarbital and pentobarbital from 4.3 to 25.8 mg/l, 3.9 to 25.3 mg/l and 5.1 to 31.5 mg/l respectively; clomipramine and desmethylclomipramine from 4.0 to 21.5 mg/l and 1.7 to 8.1 mg/l, respectively and flurazepam 0.15 to 0.99 mg/l; imipramine and desipramine from 4.1 to 18.1 mg/l and 1.0 to 3.6 mg/l, respectively. We conclude that this poorly studied phenomenon creates major difficulties in interpretation and undermines the reference value of data bases where the site of origin of post-mortem blood samples is unknown.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号