首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
An easily available, simultaneous identification/determination procedure for phentolamine (PHE) and sildenafil (SIL) in adulterated dietary supplements was established by using a combination of three different analytical methods; thin-layer chromatography (TLC), liquid chromatography-mass spectrometry (LC/MS) and a high-performance liquid chromatography (HPLC)/photo-diode-array. The sample solution for TLC was applied to silica gel 60 F(254) plates with chloroform/ammonia solution (28)/methanol (70:5:3, lower layer) and chloroform/diethylamine/methanol (15:3:2) as the developing solvent. Spots were located under UV radiation at 254 nm. Mass spectra of PHE and SIL by LC/MS were investigated with electrospray ionization (ESI) interface, under both positive and negative ion mode. The HPLC analysis was performed on a column of Wakosil 5C18 (4.6 mm x 150 mm, 5 microm) with water/methanol/acetonitrile/triethylamine (580:250:170:1) adjusted with phosphoric acid to pH 3.0 as the mobile phase, and the effluent was monitored with a photo-diode-array detector. Quantitative HPLC analysis of PHE and SIL were detected at 280 nm. When this procedure was applied to commercial soft drinks, PHE and SIL were identified and determined at a concentration of 17 mg PHE and 44 mg SIL per bottle, respectively. The procedure described here is available for the screening of PHE and SIL in adulterated supplements.  相似文献   

2.
The cis and trans isomers of 3‐methylfentanyl and its three analogs were chemically synthesized, and these compounds were characterized and differentiated by gas chromatography/mass spectrometry (GC/MS), liquid chromatography/mass spectrometry (LC/MS), and nuclear magnetic resonance (NMR) spectroscopy. The cis and trans isomers of the 3‐methylfentanyl analogs were completely separated by GC/MS. Although the high temperature of the GC injection port caused thermal degradation of β‐hydroxy‐3‐methylfentanyl, the degradation was completely suppressed by trimethylsilyl derivatization. The isomers were also well separated by LC/MS on an octadecylsilyl column with 10 mM ammonium acetate and methanol as the mobile phase. The proton NMR signals were split when the hydrochloride salts of the 3‐methylfentanyl analogs were dissolved in deuterated chloroform because stereoisomers were formed by the coordination of the hydrochloride proton to the nitrogen of the piperidine ring of the 3‐methylfentanyl analogs.  相似文献   

3.
A simple thin layer chromatographic (TLC)-image analysis method was developed for rapid determination and quantitation of sibutramine hydrochloride (SH) adulterated in herbal slimming products. Chromatographic separation of SH was achieved on a silica gel 60 F(254) TLC plate, using toluene-n-hexane-diethylamine (9:1:0.3, v/v/v) as the mobile phase and Dragendorff reagent as spot detection. Image analysis of the scanned TLC plate was performed to quantify the amount of SH. The polynomial regression data for the calibration plots showed good linear relationship in the concentration range of 1-6 μg/spot. The limits of detection and quantitation were 190 and 634 ng/spot, respectively. The method gave satisfactory specificity, precision, accuracy, robustness and was applied for determination of SH in herbal formulations. The contents of SH in adulterated samples determined by the TLC-image analysis and TLC-densitometry were also compared.  相似文献   

4.
A rapid and simple method of utilizing thin-layer chromatography (TLC) and pyrolysis gas chromatography (PyGC) for the identification and determination of methylbenactyzium bromide in human urine was studied in this report. Methylbenactyzium bromide was extracted from urine with ODS-cartridge (Sep-Pak C18), then spotted onto a silica gel 60 F254 TLC plate. After development, the separated spot of methylbenactyzium bromide was scraped and wrapped with a ferromagnetic foil without extraction by any organic solvents. The sample was applied into PyGC analysis. The optimum temperature for pyrolysis was 590 degrees C. The main degradation product of methylbenactyzium bromide was identified as diphenylmethane in this procedure by gas chromatography/mass spectrometry (GC/MS). A calibration graph prepared by absolute calibration method showed a good linearity over the concentration range of 1-75 micrograms/spot for methylbenactyzium bromide. The coefficient of variation obtained for eleven replicate analyses of the 3 micrograms/spot of standard methylbenactyzium bromide was 3.8%. The detection limit of this compound by this procedure was 0.1 micrograms/spot.  相似文献   

5.
氯胺酮的滥用及检测现状   总被引:9,自引:2,他引:7  
氯胺酮是一种高效麻醉剂,应用于人和动物的手术过程中,由于其具有一定的精神副作用而被滥用于娱乐场所。氯胺酮在体内先经N去甲基作用产生去甲氯胺酮,再脱氢生成去氢去甲氯胺酮。本文综述了氯胺酮的滥用现状和检测现状,目前文献报道的检测分析方法主要有TLC、GC/NPD、GC/MS和LC/MS等。  相似文献   

6.
Abstract:  In recent years, Salvia divinorum has become a major focus by state legislatures throughout the United States looking to prohibit the sale of the psychoactive plant. After researching testing procedures presented in the literature and those employed by crime laboratories throughout the country, it was decided that thin layer chromatography (TLC) and gas chromatography/mass spectrometry (GC/MS) were the methods to use to analyze plant material for salvinorin A. With TLC, salvinorin A was detected from extracted plant material and was easily distinguishable from 13 other Salvia species as well as Cannabis sativa L. (marijuana). When using GC/MS, salvinorin A was best extracted from plant material with chloroform at ambient temperature when using a nonpolar solvent and acetone at ambient temperature when using a polar solvent. By utilizing these techniques, criminalists are now able to confirm the presence of salvinorin A in a submitted plant material suspected to be Salvia divinorum .  相似文献   

7.
A simple and sensitive assay for the cannabinoids is presented using a dabsylation procedure. Dabsyl derivatives of delta 9-tetrahydrocannabinol (delta 9-THC) and cannabinol (CBN) were prepared by reacting with 4-dimethylaminoazobenzene-4'-sulfonyl chloride (dabsyl chloride) in acetone in the presence of sodium carbonate-sodium bicarbonate buffer (pH 10). Crystalline dabsylcannabinoids gave intense absorption in the visible region. With these derivatives, analysis by thin-layer chromatography (TLC) and high performance liquid chromatography (HPLC) were tested. These techniques gave good separation and nanogram detection of dabsyl-THC and -CBN by using n-hexane-ethyl acetate-diethylamine (20:5:1) for TLC and MeOH--H2O (95:5) at 450 nm for HPLC.  相似文献   

8.
Recently, adulterated supplements with phosphodiesterase-5 inhibitors (PDE-5i) have frequently observed. New synthetic analogues obtained from the chemical modification of parent compounds are frequently found in illicit products despite continuous efforts to inspect for these adulterants. A rapid and accurate method based on quadrupole-Orbitrap mass spectrometry was developed for simultaneously confirming and quantifying 85 PDE-5i and derived analogues present in illicit products for erectile dysfunction (ED). Common ions of PDE-5i according to their similar structures were proposed based on MS/MS fragmentations. These common ions could be an important diagnosis of their presence targets or new emerging analogues in supplements. Several validation parameters were employed, resulting in a limit of detection and quantification of 0.09–8.55 ng/mL and 0.24–17.10 ng/mL, respectively. The linear correlation coefficient (r2) was higher than 0.995, and mean recoveries of target compounds were in the range of 82–118%. A total of 187 illicit products, obtained from on/offline markets over a period of 3 years (2015–2017), were screened by the established method. Approximately 53% of them were adulterated with PDE-5i or derived analogues at concentrations of 0.1–726.0 mg/g in the illicit products. In the interests of public health, this study describes a rapid and accurate method to determine PDE-5i and new emerging analogues in adulterated products.  相似文献   

9.
In this report, three pairs of rubber-based pressure sensitive adhesives were analyzed by pyrolysis-gas chromatography/mass spectrometry (Py-GC/MS), attenuated total reflectance Fourier transform infrared spectrometry (ATR/FT-IR) and size exclusion chromatography (SEC). The size exclusion chromatograph was equipped with a refractive index (RI) detector and an ultraviolet (UV) absorption detector set to measure at 254 nm. Both adhesives of each pair revealed indistinguishable pyrograms and IR spectra, however, the SEC chromatograms were able to provide further discrimination. The differences were observed in the range below the polystyrene equivalent molecular weight of 700 Da.  相似文献   

10.
A method for simultaneous determination of glycerol and mannitol in various human tissues was devised and for this we used high-performance liquid chromatography (HPLC). Specimens were homogenized in a mixture of chloroform and methanol, phosphate buffer (pH 7.0) and pentaerythritol (IS) solution. After centrifugation, an aliquot of the aqueous layer was evaporated to dryness and derivatized with p-nitrobenzoyl chloride at 50 degrees C for 1h, then applied to HPLC with analytical conditions of: column, CAPCELL PAK C18 MG (250 mm x 3.0 mm i.d., 5 microm, Shiseido Co. Ltd., Tokyo, Japan); column temperature, 1-2 degrees C; mobile phase, 75% acetonitrile-distilled water containing 0.05% trifluoroacetic acid, 0.05% heptafluoro-n-butyric acid and 0.1% triethylamine; flow rate, 0.5 ml/min; wavelength, 260 nm. Calibration curves for both substances were linear in concentration ranges from 1 to 500 microg/0.1g and correlation coefficients exceeded 0.99. The relative standard deviation (R.S.D.) of the method was evaluated at concentrations of 10 and 100 microg/0.1g, and ranged from 0.84 to 10.6%. Using this method, we determined the regional distribution levels of glycerol and mannitol in various tissues from an autopsied brain dead man.  相似文献   

11.
This paper describes two analytical techniques used to separate and quantify gamma-hydroxybutyrate (GHB) and gamma-hydroxyvalerate (GHV). The first technique was a N,O-bis(trimethylsilyl)triflouro-acetimide-trimethylchlorosilane derivatization, followed by gas chromatography/mass spectrometry analysis using an HP-5 capillary column at a rate of 1.0 mL/min with a run time of 9.25 min. This technique was found to be sensitive (LOD 1 pg on column) and gave a low average error (5%) in a beverage study. When supplemented by a surrogate spike, the method yielded 97% analyte recovery from beverages. The second technique was high-performance liquid chromatography/UV (HPLC/UV) using a C-18 column with a (20:80% v/v) methanol:dibasic phosphoric buffer (10 mM, pH 3) at a rate of 1.00 mL/min with a run time of 7.5 min. UV detection occurred at 254 nm. This method was found to be less sensitive (LOD 0.05 microg on column) for direct analysis of aqueous samples. To remove interferences seen in the beverage study, a liquid-liquid extraction before HPLC analysis was tested. However, a decreased sensitivity (LOD 100 microg on column) and irreproducible peak profiles resulted.  相似文献   

12.
Abstract: Enzyme‐linked immunosorbent assay (ELISA) and liquid chromatography tandem mass spectrometry (LC/MS/MS) were used to detect diazepam exposure in skeletal tissues of rats (n = 15) given diazepam acutely (20 mg/kg, i.p.), and killed at various times postdose. Marrow, epiphyseal, and diaphyseal bone were isolated from extracted femora. Bone was cleaned, ground, and incubated in methanol. Marrow underwent ultrasonic homogenization. Extracts and homogenates were diluted in phosphate buffer, and then underwent solid‐phase extraction and ELISA. Relative sensitivity of detection was examined in terms of relative decrease in absorbance (ELISA) and binary classification sensitivity (ELISA and LC/MS/MS). Overall, the data showed differences in relative sensitivity of detection of diazepam exposure in different tissue types (marrow > epiphyseal bone > diaphyseal bone), which is suggestive of heterogenous distribution in these tissues, and a decreasing sensitivity with increasing dose‐death interval. Thus, the tissue type sampled and dose‐death interval may contribute to the probability of detection of diazepam exposure in skeletal tissues.  相似文献   

13.
A simple and rapid method, for the isolation of eight triazine herbicides from human serum and urine, using Sep-Pak C18 cartridges is presented. After mixing with distilled water, serum and urine samples containing the herbicides, were loaded on Sep-Pak C18 cartridges and eluted with either chloroform only or chloroform/methanol (9:1). The herbicides were detected by capillary gas chromatography with both flame ionization detection (FID) and nitrogen-phosphorus detection (NPD). Separation of eight triazine herbicides from each other and from impurities was generally satisfactory with the use of a non-polar DB-1 capillary column. Recovery of most compounds was excellent for both chloroform and chloroform/methanol (9:1) as elution solvents. Backgrounds were cleaner and evaporation time was shorter for the chloroform only than for the chloroform/methanol (9:1). The NPD gave sensitivity more than 10-20 times higher than that of FID.  相似文献   

14.
A rapid and sensitive liquid chromatography/electrospray ionization mass spectrometry (LC/MS) procedure has been developed for the analysis of biofluids containing flunitrazepam and its metabolites. Specimens were spiked with deuterated analogs of the analytes. Urine specimens were enzymatically hydrolyzed and blood specimens were untreated. Extractions were carried out using CleanScreen DAU SPE cartridges. The drugs were separated on a C18 column using a methanol-water-ammonium hydroxide (60:40: 0.03 v/v) mobile phase. After determination of base peaks using full scan mass spectrometry, the mass spectrometry method was optimized to operate in selected-ion monitoring (SIM) mode for the base peak of each analyte. Positive findings were confirmed by LC/MS/MS using the same mobile phase and column. This analytical procedure allows for the detection of low levels of flunitrazepam and metabolites in biofluids. It is useful for ascertaining the role of flunitrazepam in cases of drug-facilitated sexual assault.  相似文献   

15.
Human xylazine poisoning is uncommon. This report describes the use of xylazine for intentional poisoning with criminal intent. Two incidents occurred within 3 weeks: the first involved one victim, and the second involved two victims. The clinical presentations were brief coma, bradycardia, hypotension, and hyperglycemia. The victims recalled having been given a drink from a stranger in a hospital waiting room before loss of consciousness. In the first case, general drug screening by gas chromatography/mass spectrometry (MS) revealed xylazine in the gastric contents, but liquid chromatography–tandem MS (LC‐MS/MS) of serum did not. In the second incident, LC‐MS/MS screening of both victims’ urine and serum samples revealed an unknown peak in the total ion chromatograms, which a molecular mass database identified as morantel or xylazine. The latter was confirmed by comparison with a xylazine standard. Based on this report, we suggest that xylazine should be classified as a controlled drug.  相似文献   

16.
Abstract: A method capable of quantifying endogenous concentrations of gamma‐hydroxybutyrate (GHB) in human head hair was developed and validated using liquid chromatography/mass spectrometry/mass spectrometry (LC/MS/MS). Hair was digested under alkaline conditions, and GHB was isolated using liquid–liquid extraction. LC/MS/MS was performed using atmospheric pressure chemical ionization in the negative mode, multiple reaction monitoring, and deuterated internal standard (GHB‐D6). Linearity was observed between 0.1 and 100 ng/mg GHB (R2 = 1.000). The limits of detection and quantitation in human hair were 0.2 and 0.4 ng/mg, respectively. Accuracy at 2 ng/mg and 10 ng/mg was determined to be 97% and 94%, and intra‐assay CVs at these concentrations were 5.2% and 7.4% (n = 4). Beta‐hydroxybutyrate (BHB), alpha‐hydroxybutyrate, gamma‐butyrolactone, and 1,4‐butanediol did not produce an interference, and there was negligible ion suppression or enhancement from the matrix.  相似文献   

17.
LC/MS/MS法测定生物组织中百草枯   总被引:2,自引:1,他引:1  
目的建立LC/MS/MS检测生物体液中百草枯方法。方法弱阳离子交换固相萃取小柱提取剂,应用LC/MS/MS法对生物样品中百草枯进行定性定量分析。结果经该方法测得百草枯的最小检出限为10ng/ml血(S/N≥3),线性范围为0.02~20μg/ml。结论该方法快速、灵敏、准确,适用于生物检材中百草枯的分析。  相似文献   

18.
Lin L  Liao LC  Yan YY 《法医学杂志》2003,19(2):126-128
海洛因在体内极易代谢,其主要的代谢产物为单乙酰吗啡、吗啡等。目前,检测海洛因代谢物的常用生物检材有尿液、血液、毛发等;常用分析方法有薄层色谱法、气相色谱法、高效液相色谱法、气相色谱-质谱联用法、液相色谱-质谱联用法、免疫分析法、毛细管电泳法等。本文参考近年来的文献对生物检材中海洛因代谢物的分析方法作一综述,为法医毒物分析等相关领域的研究提供参考。  相似文献   

19.
Comparative analysis of illicit heroin samples   总被引:2,自引:0,他引:2  
The comparative analysis of street heroin samples is still an object of scientific discussion. A combination of a wide range of analytical techniques is necessary to obtain a valid amount of information about the sample composition, and it is impossible to define an unique analytical approach. We suggest a complete analytical sequence based on analysis of volatile compounds, opiates, diluents, adulterants and metals, by head space gas chromatography (HS/GC), gas chromatography mass spectrometry (GC/MS), thin layer chromatography (TLC), high pressure liquid chromatography (HPLC) and atomic absorption (AA) using a sample amount as low as 50-100 mg. The outlined procedure can be successfully applied to routine work, thus obtaining suitable information about a sample's chemical composition. This helps to attribute or exclude common sources of separate specimens. Results obtained on 33 street heroin samples confiscated in the metropolitan area of Rome are listed.  相似文献   

20.
A reversed phase high performance liquid chromatographic method was developed for the determination of cephradine, one of the commonly used antibiotics, in biological materials. Mimic samples for stomach contents, miso soup, were applied to high performance liquid chromatography (HPLC) after centrifugation and purification by Sep-Pak C18 cartridge treatment. Serum samples deproteinized or urine samples diluted were directly injected into the HPLC. The recoveries of cephradine from these materials were 95-97% and the detection limit was 0.01 microgram/injection. This method was applied to the analysis of cephradine in stomach contents obtained by autopsy. After purification by the cartridge treatment, cephradine in the sample was identified and determined by HPLC and further confirmed by thin-layer chromatography (TLC) and mass spectrometry (MS).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号