首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 385 毫秒
1.
A sensitive analytical method was developed for quantitative analysis of delta(9)-tetrahydrocannabinol (delta(9)-THC), 11-nor-delta(9)-tetrahydrocannabinol-carboxylic acid (delta(9)-THC-COOH), cannabinol (CBN) and cannabidiol (CBD) in human hair. The identification of delta(9)-THC-COOH in hair would document Cannabis use more effectively than the detection of parent drug (delta(9)-THC) which might have come from environmental exposure. Ketamine was added to hair samples as internal standard for CBN and CBD. Ketoprofen was added to hair samples as internal standard for the other compounds. Samples were hydrolyzed with beta-glucuronidase/arylsulfatase for 2h at 40 degrees C. After cooling, samples were extracted with a liquid-liquid extraction procedure (with chloroform/isopropyl alcohol, after alkalinization, and n-hexane/ethyl acetate, after acidification), which was developed in our laboratory. The extracts were analysed before and after derivatization with pentafluoropropionic anhydride (PFPA) and pentafluoropropanol (PFPOH) using a Hewlett Packard gas chromatographer/mass spectrometer detector, in electron impact mode (GC/MS-EI). Derivatized delta(9)-THC-COOH was also analysed using a Hewlett Packard gas chromatographer/mass spectrometer detector, in negative ion chemical ionization mode (GC/MS-NCI) using methane as the reagent gas. Responses were linear ranging from 0.10 to 5.00 ng/mg hair for delta(9)-THC and CBN, 0.10-10.00 ng/mg hair for CBD, 0.01-5.00 ng/mg for delta(9)-THC-COOH (r(2)>0.99). The intra-assay precisions ranged from <0.01 to 12.40%. Extraction recoveries ranged from 80.9 to 104.0% for delta(9)-THC, 85.9-100.0% for delta(9)-THC-COOH, 76.7-95.8% for CBN and 71.0-94.0% for CBD. The analytical method was applied to 87 human hair samples, obtained from individuals who testified in court of having committed drug related crimes. Quantification of delta(9)-THC-COOH using GC/MS-NCI was found to be more convenient than GC/MS-EI. The latter may give rise to false negatives due to the detection limit.  相似文献   

2.
The objective of this study was to compare urinary excretion patterns of two cannabinoid metabolites in subjects with a history of chronic marijuana use. The first metabolite analyzed was nor-9-carboxy-delta9-tetrahydrocannabinol (delta9-THC-COOH), the major urinary cannabinoid metabolite that is pharmacologically inactive. The second metabolite 11-OH-delta9-THC is an active cannabinoid metabolite and is not routinely measured. Urine specimens were collected from four subjects on 12-20 occasions > or = 96 h apart in an uncontrolled clinical setting. Creatinine was analyzed in each urine specimen by the colorimetric modified Jaffé reaction on a SYVA 30R biochemical analyzer. All urine specimens analyzed for 11-OH-delta9-THC had screened positive for cannabinoids with the EMIT II Plus cannabinoids assay (cut-off 50 ng/mL) on a SYVA 30R analyzer and submitted for delta9-THC-COOH confirmation by GC-MS (cut-off concentration 15 ng/mL). Eleven-OH-delta9-THC was measured by GC-MS with a cut-off concentration of 3 ng/mL. Both GC-MS methods for cannabinoid metabolites used deuterated internal standards for quantitative analysis. The mean (range) of urinary delta9-THC-COOH concentration was 1153 ng/mL (78.7-2634) with a cut-off of 15 ng/mL. The mean (range) of delta9-THC-COOH/creatinine ratios (ng/mL delta9-THC-COOH/mmol/L creatinine) was 84.1 (8.1-122.1). The mean (range) urinary of 11-OH-delta9-THC concentration was 387.6 ng/mL (11.9-783) with a cut-off of 3 ng/mL, and the mean (range) of 11-OH-delta9-THC/creatinine ratio (ng/mL 11-OH-delta9-THC/mmol/L creatinine) was 29.7 (1.2-40.7). Of the 63 urine specimens submitted for delta9-THC-COOH confirmation by GC-MS, 59/63 urine specimens (94%) were positive for delta9 -THC-COOH and 51/63 (81%) were positive for 11-OH-delta9-THC. Overall, the concentrations of 11-OH-delta9-THC in urine specimens collected > or = 96 h apart were lower than delta9-THC-COOH concentrations in 50/51 of the urine specimens in this population. Further urinary cannabinoid excretion studies are needed to assess whether 11-OH-delta9-THC analyses have a role when assessing previous marijuana or hashish use in chronic users whose urine specimens remain positive for delta9-THC-COOH for an extended period of time after last drug use.  相似文献   

3.
尿样中苯骈二氮杂Zhu类药物筛选分析研究   总被引:1,自引:0,他引:1  
目的建立尿样中苯骈二氮杂类药物两种筛选分析方法.方法用GC/ECD、GC/MS直接测定苯骈二氮杂类药物原体和GC/ECD、GC/MS测定1,4-苯骈二氮杂类药物的酸水解产物苯甲酮同系物.结果GC/ECD直接测定苯骈二氮杂类药物方法,大部分药物的回收率为60%~90%,线性范围为20~200ng/ml尿,线性相关系数大于0.99,最低检出限达0.5ng/ml~10ng/ml.结论所建两种方法各有其特点又可相互补充,已成功地应用于司法鉴定实践.  相似文献   

4.
A pilot study was conducted to ascertain the range of induced hemolyzed blood/serum delta 9-tetrahydrocannabinol (delta 9-THC) concentrations in 58 human subjects. Subjects were tested within 5 min of smoking a delta 9-THC cigarette and then at half-hour intervals to 150 min. The subjects initially demonstrated a broad range of delta 9-THC hemolyzed blood levels, which settled within an hour to levels comparable to those measured in California drivers who had been stopped for impaired driving, arrested, and tested for delta 9-THC. Serum levels, when correlated with performance or roadside sobriety tests, demonstrated a broad range (5 to 183 ng/mL) of delta 9-THC levels and an "adaptation" effect in the subjects' perception of their own impairment. Although this preliminary study was not a double-blind placebo experiment, the overall performance of human subjects demonstrated the "adaptation" effect, which may be a significant factor in making judgments while performing such complex tasks as driving. Also, the effects of the drug extended beyond the period of elevated delta 9-THC blood levels, perhaps because of THC metabolites that may contribute to impairment or the persistence of THC in the central nervous system. This pilot study will lay the groundwork for a program designed to determine the epidemiology and behavior correlates of marijuana use in motorists.  相似文献   

5.
HS/GC/ECD分析生物检材样品中的氰化物   总被引:5,自引:1,他引:4  
目的 建立生物样品中氰化物的衍生化定性定量分析方法。方法 用氯胺T衍生化,HS/GC/ECD分析衍生物CICN。结果 在1ml血中,添加0.2μg氰化钾,回收率为84.6%,RSD为6.39%;在1g肝中添加0.5μg氰化钾,回收率为67.3%,RSD为5.05%;血中检出限为5ng/ml。结论 所建方法能定性定量分析生物样品中的氰化物。  相似文献   

6.
用气相色谱法/电子捕获检测器测定尿液中的三唑仑   总被引:1,自引:1,他引:0  
Liu W 《法医学杂志》1998,14(4):203, 208, 251
建立了用气相色谱/电子捕获检测器测定尿液中三唑仑含量的方法。2ml尿样在破性条件下用2ml×2氯仿提取净化后,60℃水浴下用空气吹干,残留物用环己烷定容溶解后,进气相色谱仪分析,三唑仑的保留时间为10.74min。最低检测限为0.5ng/ml,回收率为95.98%,变异系数为7.85%(n=5)。在2~50ng/ml浓度范围内有良好的线性关系:A=-67.9+570.IC,r=0.9939。  相似文献   

7.
氟乙酸五氟苄基酯的气相色谱分析   总被引:2,自引:0,他引:2  
目的 对氟乙酸根阴离子的衍生物-氟乙酸五氟苄基酯(PFB-MFA)进行了气相色谱分析,以满足氟乙酰胺类鼠药化验工作的需要。方法 使用GC/ECD、GC/MS Scan、GC/MS SIM对该化合物的标准溶液进行了分析,得到了各种分析方法的校正曲线及检测限。结果 三种方法测定PFB-MFA的线性范围分别为GC/ECD 0.01~0.1ng/μl、GC/MS SCAN 1~100ng/μl、GC/MS SIM 5×10~(-3)~1ng/μl。三种方法对氟乙酸根阴离子的检测限分别为:GC/ECD1.31×10~(-4)ng/μl、GC/MS SCAN 0.13ng/μl、GC/MS SIM 1.76×10~(-4)ng/μl。结论 氟乙酸根阴离子的衍生物氟乙酸五氟苄基酯在GC/ECD及GC/MS上具有一定的线性范围,有非常高的灵敏度,可用于法庭科学的定性定量分析。  相似文献   

8.
Saliva or "oral fluid" has been presented as an alternative matrix to document drug use. The non-invasive collection of a saliva sample, which is relatively easy to perform and can be achieved under close supervision, is one of the most important benefits in a driving under the influence situation. Moreover, the presence of Delta9-tetrahydrocannabinol (THC) in oral fluid is a better indication of recent use than when 11-nor-Delta9-tetrahydrocannabinol-9-carboxylic acid (THC-COOH) is detected in urine, so there is a higher probability that the subject is experiencing pharmacological effects at the time of sampling. In the first part of the study, 27 drug addicts were tested for the presence of THC using the OraLine IV s.a.t. device to establish the potential of this new on-site DOA detection technique. In parallel, oral fluid was collected with the Intercept DOA Oral Specimen Collection device and tested for THC by gas chromatography mass spectrometry (GC/MS) after methylation for THC (limit of quantification: 1 ng/mL). The OraLine device correctly identified nine saliva specimens positive for cannabis with THC concentrations ranging from 3 to 265 ng/mL, but remained negative in four other samples where low THC concentrations were detected by GC/MS (1-13 ng/mL). One false positive was noted. Secondly, two male subjects were screened in saliva using the OraLine and Intercept devices after consumption of a single cannabis cigarette containing 25mg of THC. Saliva was first tested with the OraLine device and then collected with the Intercept device for GC/MS confirmation. In one subject, the OraLine on-site test was positive for THC for 2 h following drug intake with THC concentrations decreasing from 196 to 16 ng/mL, while the test remained positive for 1.5 h for the second subject (THC concentrations ranging from 199 to 11 ng/mL). These preliminary results obtained with the OraLine IV s.a.t. device indicate more encouraging data for the detection of THC using on-site tests than previous evaluations.  相似文献   

9.
尿中氯胺酮及其代谢物检测的研究   总被引:3,自引:0,他引:3  
目的建立氯胺酮滥用者尿中氯胺酮及其代谢物检测方法。方法尿液用有机溶剂液-液萃取,气相色谱/氮磷检测器、电子捕获检测器、氢火焰检测器和气-质联用仪测定。结果确认了尿液中氯胺酮的主要代谢物,尿液中氯胺酮及去甲氯胺酮的最小检测限均为2ng/mL,脱氢去甲氯胺酮的最小检测限为5ng/mL。结论所建方法快速、灵敏、准确,能够满足氯胺酮滥用者尿液检测的需要。  相似文献   

10.
A fully validated, sensitive and specific method for the extraction and quantification of Delta(9)-tetrahydrocannabinol (THC) and 11-nor-9-carboxy-Delta(9)-THC (THC-COOH) and for the detection of 11-hydroxy-Delta(9)-THC (11-OH THC) in oral fluid, urine and whole blood is presented. Solid-phase extraction and liquid chromatography-mass spectrometry (LC-MS) technique were used, with electrospray ionization. Three ions were monitored for THC and THC-COOH and two for 11-OH THC. The compounds were quantified by selected ion recording of m/z 315.31, 329.18 and 343.16 for THC, 11-OH THC and THC-COOH, respectively, and m/z 318.27 and 346.26 for the deuterated internal standards, THC-d(3) and THC-COOH-d(3), respectively. The method proved to be precise for THC and THC-COOH both in terms of intra-day and inter-day analysis, with intra-day coefficients of variation (CV) less than 6.3, 6.6 and 6.5% for THC in saliva, urine and blood, respectively, and 6.8 and 7.7% for THC-COOH in urine and blood, respectively. Day-to-day CVs were less than 3.5, 4.9 and 11.3% for THC in saliva, urine and blood, respectively, and 6.2 and 6.4% for THC-COOH in urine and blood, respectively. Limits of detection (LOD) were 2 ng/mL for THC in oral fluid and 0.5 ng/mL for THC and THC-COOH and 20 ng/mL for 11-OH THC, in urine and blood. Calibration curves showed a linear relationship for THC and THC-COOH in all samples (r(2)>0.999) within the range investigated. The procedure presented here has high specificity, selectivity and sensitivity. It can be regarded as an alternative method to GC-MS for the confirmation of positive immunoassay test results, and can be used as a suitable analytical tool for the quantification of THC and THC-COOH in oral fluid, urine and/or blood samples.  相似文献   

11.
Blind trials of an onsite saliva drug test for marijuana and opiates   总被引:5,自引:0,他引:5  
The objective of these clinical trials was to calculate the performance, limit of detection, specificity and sensitivity of a novel, semi-quantitative immunoassay for drugs of abuse in saliva and to determine operator bias when measured blind by four different operators. The test is based on lateral flow gold particle technology coupled with digital photography to provide a semi-quantitative end point. The performance of the test was compared with that of enzyme immunoassays and GC/MS methods. Volunteers consumed marijuana or codeine and their saliva was collected 0.25 to 24 h later with the Cozart RapiScan collection device. The sensitivity and specificity of the opiate test were both 100%+/-10.4% for codeine for 9 h after dosing. The cutoff of the marijuana test at 10 ng/mL THCA was too high to detect marijuana use for more than a few hours after smoking. There was no operator bias because the results were presented in written form either as "positive" or "negative" for each of the five drug classes on the screen of the hand-held reader.  相似文献   

12.
Headspace solid phase microextraction (HS-SPME) has advantages of high purity of the extract, avoidance of organic solvents and simple technical manipulation and can be used in combination with gas chromatography-mass spectrometry (GC-MS) in the hair analysis of a number of drugs. HS-SPME coupled with the hydrolysis of the hair matrix by 4% sodium hydroxide in the presence of excess sodium sulphate and of a suitable internal standard proved to be a convenient one-step method for the measurement of many lipophilic basic drugs such as nicotine, amphetamine derivatives, local anaesthetics, phencyclidine, ketamine, methadone, diphenhydramine, tramadol, tricyclic antidepressants and phenothiazines. Detection limits were between 0.05 and 1.0 ng/mg. From spiked 10-mg hair samples absolute recoveries between 0.04 and 5.7% were found. These recoveries decreased considerably if larger sample amounts were used, perhaps due to increased drug solubility in the aqueous phase or to elevated viscosity in the presence of dissolved hair proteins. Because of the phenolic hydroxyl group a change of pH after alkaline hair digestion (by adding excess orthophosphoric acid) was necessary for the detection of delta 9-tetrahydrocannabinol (delta 9-THC), cannabinol (CBN) and cannabidiol (CBD) by HS-SPME. Nevertheless, the detection limits were such that only CBN could be detected in hair of a consumer. Clomethiazole, a compound hydrolysed in alkali, was measured by HS-SPME after extraction with aqueous buffer. The detection limit was 0.5 ng/mg. Cocaine could not be detected by HS-SPME. The application of HS-SPME to hair samples from several forensic and clinical cases is described.  相似文献   

13.
A fast method using automated solid-phase extraction (SPE) and short-column liquid-chromatography coupled to tandem mass-spectrometry (LC/MS/MS) with negative atmospheric-pressure chemical ionisation (APCI) has been developed for the confirmation of 11-nor-9-carboxy-Delta(9)-tetrahydrocannabinol (THC-COOH) in urine samples. This highly specific method which combines chromatographic separation and MS/MS-analysis can be used for the confirmation of positive immunoassay results with a NIDA cut-off of 15ng/ml. The conjugates of THC-COOH were hydrolysed prior to SPE, and a standard SPE was performed using C18-SPE columns. No derivatisation of the extracts was needed as in GC/MS analysis, and the LC run-time was 6.5min by gradient elution with a retention time of 2.4min. Linearity of calibration was obtained in the range between 0 and 500ng/ml (correlation coefficient R(2)=0.998). Using linear regression (0-50ng/ml) the limit of detection (LOD) was 2.0ng/ml and the limit of quantitation (LOQ) was 5.1ng/ml; day-to-day reproducibility and precision were tested at 15 and 250ng/ml and were 13.4ng/ml+/-3.3% and 255.8ng/ml+/-4.5%, respectively.  相似文献   

14.
The objective of the present work was to study conditions for isolation of ketorolac and diclofenac from biological fluids. A method of their extraction with a mixture of organic solvents has been developed and the conditions for the identification of these compounds are proposed with the use of high performance liquid chromatography (HPLC), UV spectroscopy, and gas chromatography with electron capture detection (GC/ECD). The possibilities of using HPLC, UV spectrometry, and GC/ECD for quantitative determination of ketorolac and diclofenac are illustrated.  相似文献   

15.
GC/MS和GC法定性定量分析可卡因   总被引:1,自引:0,他引:1  
目的建立用于可卡因案件检验鉴定的GC和GC/MS定性、定量分析方法。方法通过选择和优化,建立GC、GC/MS法检验可卡因的最佳分析条件;用分别含0.6mg/ml地西泮为内标的0.10、0.20、0.40、0.60、0.80、1.00、1.20mg/ml可卡因标准品乙醇液,考察线性范围和方法检测限。结果分析方法线性方程:GC/FID,Y=1.055X-0.0021,R2=0.9999,GC/NPD,Y=0.556X-0.0016,R2=0.9996;可卡因检测限:GC/FID法10ng,GC/NPD法2ng;分别以所建GC/FID、GC/NPD分析方法和内标法对案件中缴获的可卡因毒品进行定量分析,结果为72%±2.3%,且两方法定量重现性良好。结论本文所建方法可以用于可卡因涉毒案件的检验鉴定。  相似文献   

16.
The aim of this study was to assess the effectiveness of two current on-site oral fluid (OF) drug detection devices (OraLab and Dr?ger), as part of the Spanish participation in the Roadside Testing Assessment Project (ROSITA Project). The study was done in collaboration with the Spanish Traffic Police, in Galicia (NW Spain), during 2004 and 2005. A total of 468 drivers selected at the police controls agreed to participate through informed consent. In addition, saliva samples were collected and sent to the laboratory to confirm the on-site results. For this purpose, two different analytical liquid chromatography-mass spectrometry (LC-MS) methods were used to detect 11 drugs or metabolites in a 300 microL sample. Simultaneous analysis of morphine, 6-acetylmorphine, amphetamine, methamphetamine, MDA, MDMA, MDEA, MBDB, cocaine and benzoylecgonine was carried out using 100 microL of oral fluid, after an automated solid phase extraction. A different LC-MS method was performed to detect Delta(9)-THC in 200 microL of oral fluid using liquid-liquid extraction with hexane at pH 6. Both methods were fully validated, including linearity (1-250 ng/mL, 2-250 ng/mL) recovery (>50%), within-day and between-day precision (CV<15%), accuracy (mean relative error<15%), limit of detection (0.5 and 1 ng/mL), quantitation (1 and 2 ng/mL) and matrix effect. All of the positive cases and a random selection of 30% of the negatives were analyzed for confirmation analysis. Good results (sensitivity, specificity, accuracy, positive predictive value and negative predictive value>90%) were obtained for cocaine and opiates by OraLab, and for cocaine by Dr?ger. However, the results for the other compounds could be improved for both detection devices. Differences in the ease of use and in the interpretation mode (visual or instrumental) were observed.  相似文献   

17.
The EMIT cannabinoid assay was used for screening blood and urine after smoking tetrahydrocannabinol (THC; 10 mg) or ingestion of THC (30 mg). Cannabinoid levels in urine remain detectable up to 1 week. Confirmation was done by adsorption of the THC carboxylic acid onto a C18 extraction column and elution with acetone and TLC. The method is simple and sensitive and is applicable with common laboratory equipment. The detection limit is 10 ng/ml, using 10 ml urine.  相似文献   

18.
体液中常见滥用药物的系统筛选分析   总被引:6,自引:1,他引:5  
本文建立了体液中常见滥用药物的筛选分析体系.尿液或血液经固相萃取(SPE)或液提取(LLE)后,直接用GC/NPD分析或经TFA、BSTFA衍生化后用GC/MS分析.方法适用于同时分析甲基苯丙胺、MDMA、度冷丁、去甲度冷丁、曲马多、美沙酮、EDDP、可卡因、苯甲酰芽子碱、可待因、安定、氯丙嗪、吗啡、单乙酰吗啡等十四种常见滥用药物及代谢物.SPE法和LLE法回收率分别为66~102%和50~86%,最低检出限为2-5ng/ml尿.涉毒案件的鉴定应用表明该分析方法简便、快速、可靠.  相似文献   

19.
Acetylcodeine (AC), an impurity of illicit heroin synthesis, was investigated as a urinary biomarker for detection of illicit heroin use. One hundred criminal justice urine specimens that had been confirmed positive by GC/MS for morphine at concentrations >5000 ng/ml were analyzed for AC, 6-acetylmorphine (6AM), codeine, norcodeine and morphine. The GC/MS analysis was performed by solid phase extraction and derivatization with propionic anhydride. Total codeine and morphine concentrations were determined by acid hydrolysis and liquid/liquid extraction. AC was detected in 37 samples at concentrations ranging from 2 to 290 ng/ml (median, 11 ng/ml). 6AM was also present in these samples at concentrations ranging from 49 to 12 600 ng/ml (median, 740 ng/ml). Of the 63 specimens negative for AC, 36 were positive for 6AM at concentrations ranging from 12 to 4600 ng/ml (median, 124 ng/ml). When detected, the AC concentrations were an average of 2.2% (0.25 to 10.2%) of the 6AM concentrations. There was a positive relationship between AC concentrations and 6AM concentrations (r=0.878). Due to its very low concentration in urine, AC was found to be a much less reliable biomarker for illicit heroin use than 6AM in workplace or criminal justice urine screening programs. However, AC detection could play an important role in determining if addicts in heroin maintenance programs are supplementing their supervised diacetylmorphine doses with illicit heroin.  相似文献   

20.
Cannabinoids in blood and urine after passive inhalation of Cannabis smoke   总被引:1,自引:0,他引:1  
To test the possibility that cannabinoids are detectable following passive inhalation of Cannabis smoke the following study was performed. Five healthy volunteers who had previously never used Cannabis, passively inhaled Cannabis smoke for 30 min. Cannabis smoke was provided by other subjects smoking either marijuana or hashish cigarettes in a small closed car, containing approximately 1650 L of air. delta 9-Tetrahydrocannabinol (THC) could be detected in the blood of all passive smokers immediately after exposure in concentrations ranging from 1.3 to 6.3 ng/mL. At the same time total blood cannabinoid levels (assayed by radioimmunoassay [RIA] ) were higher than 13 ng/mL in four of the volunteers. Both THC and cannabinoid blood concentrations fell close to the cutoff limits of the respective assays during the following 2 h. Passive inhalation also resulted in the detection of cannabinoids in the urine by RIA and enzyme multiple immunoassay technique (EMIT) assays (above 13 and 20 ng/mL, respectively). It is concluded that the demonstration of cannabinoids in blood or urine is no unequivocal proof of active Cannabis smoking.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号