首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
目的观察橡胶弹射人口的形态特征,并探讨其法医学意义。方法使用9mm警用转轮手枪发射橡胶弹,在实验动物胸腹部侧面垂直射击,射击距离分别为紧密接触射击(0cm),相对接触射击(1~6cm),近距离射击(6-60cm)和远距离射击(60cm~有效射程25m)。92式手枪采取相同方式射击实验动物作为对照。观察射入口的形态特征,制作组织病理学切片,HE染色显微镜下观察。结果橡胶弹接触射击和近距离射击,射入口边缘整齐,有明显的擦拭轮、挫伤轮和火药斑纹;远距离射击,可见射人口边缘撕裂,挫伤轮明显增宽,皮下出血显著;与手枪弹射入口形态特征明显不同。结论9mm警用转轮手枪橡胶弹射入口典型的形态特征,可作为此类损伤的诊断指标。  相似文献   

2.
Four cases of homicide, in which silenced firearms were used, are reported and supplemented by data from experimental investigations regarding wound features, marks, traces, and ballistic behavior. Wound features are largely determined by the construction of the silencer. In one case, even a muzzle imprint was produced by a silenced weapon fired at contact range. In general, silencers are likely to result in a decrease in bullet energy and accelerated energy release in the target (tissue). In terms of wound morphology, silencers produced a reduction in or even a lack of the contact ring (ring of dirt). In close-range and contact wounds, any features indicative of shots fired at close range were missing (such as soot deposit and powder tattooing). It is also worth mentioning that biological matter may get into the silencer in shots fired at contact range.  相似文献   

3.
A case of disguised suicide is presented. A 77-year-old man had made technical arrangements so that the pistol with which he shot himself was thrown aside by the elasticity of a rubber band, to which it was tied, and was thereby hidden. After the shot the man fell and crushed his head, which initially concealed the bullet wound. A scrutinizing technical investigation at the scence of the death with close collaboration between the experts involved, revealed the true circumstances. No explanation for the attempt to conceal the suicide was found.  相似文献   

4.
《Federal register》1998,63(168):46174-46175
The final rule for user labeling requirements for natural rubber-containing medical devices, 21 CFR 801-437, was published on September 30, 1997, and becomes effective on September 30, 1998. The Food and Drug Administration (FDA) is adding a note to that rule to stay, for 270 days from the effective date, paragraphs (f) and (g) as those final rule requirements relate to device packaging that uses "cold seal" adhesives. Labeling changes required by other paragraphs of this final rule must be incorporated in the labeling of devices distributed after September 30, 1998, even if the devices are packaged in "cold seal" packages. Device packaging that uses natural rubber only on adhesives contained in the flaps of device packaging is not considered subject to the rule. Manufacturers of devices packaged with "cold seal" adhesives may, if necessary, submit a petition for an extension of the 270-day stay.  相似文献   

5.
目的 探讨跳弹创形成的条件,研究跳弹在体内弹道学特点及致伤能力,建立跳弹创的诊断依据。方法选用国产54式手枪及56式半自动步枪,配用51式手枪弹及56式步枪弹以水磨石板为反跳靶体,射击约克夏种猪4头,复制出跳弹创模型12例。观察射入口、创道及着弹点特征。结果 跳弹的形成受靶体性状、弹头形态和速度、入射角与反跳角等条件因素的影响;在相同条件下高初速尖型弹头的反跳角<低初速圆型弹头;创道无明显瞬时空腔效应;根据实验结果建立了6项诊断依据。结论 正确诊断跳弹创对射击方向和距离、重建弹道、分析枪击目的、评估损伤程度有实用价值。  相似文献   

6.
The Très Haute Vitesse (THV) bullet was introduced to meet the requirements of law enforcement officers, as an alternative to larger calibre fully jacketed bullets, since expanding or exploding bullets are not relevant in Europe. To examine the effect of the THV bullet in tissue, especially the size of the lesion and the degree of overpenetration, 11 recently killed pigs were shot with the weapons used by the Danish Police Force and a 9-mm pistol for reference. The ammunition was THV in the calibres 7.65 mm, 0.38, and 9 mm, using conventional fully jacketed bullets for comparison. The lesions were considerably larger when the THV bullet was used, the entry wound in particular, being roughly twice the diameter in the case of the THV bullet as compared to the fully jacketed bullet of similar calibre. Only one 7.65-mm THV bullet overpenetrated the target when fired against the thorax or abdomen of the pigs and then with only minimal residual energy. All fully jacketed 7.65-mm bullets, all 0.38 bullets, with the exception of one THV bullet, and all 9-mm bullets overpenetrated the target. The 7.65-mm THV bullet produced a lesion which in its extent resembled that of the fully jacketed 9-mm bullet, and should be a suitable alternative for the Danish Police Force.  相似文献   

7.
Bullet embolism is a relatively unusual complication of gunshot wounds. Embolism to the right atrium comprises <5% of all reported intravascular bullet emboli. We report an additional case of bullet embolus to the right atrium of a 0.38-caliber bullet following a gunshot wound to the chest. The intracardiac bullet was recognized radiologically on presentation, but the patient was hemodynamically stable and managed conservatively, with the bullet left in place. The missile remained within the heart without clinical significance for several years and was recovered from the right atrium only at the time of autopsy. To the best of our knowledge, this is the first documented case of a 0.38-caliber bullet which embolized to the right atrium and remained inconsequential for an extended period of time.  相似文献   

8.
We demonstrate here how the shooting distance of a 9-mm Parabellum FMJ bullet (115gr) has been estimated via shooting experiments. Such a bullet was found by investigators near a concrete wall, fairly distorted at its tip. The bullet carries no evidence of multiple impact and no evidence of ballistic impact on the wall has been reported. We estimated the impact velocity by comparing the questioned bullet with a set of comparison bullets hitting a wall (rigid target) with different velocities. The shooting distance was recovered from the impact velocity by studying the typical behavior of a manufactured 9 mm bullet weighting 115 g (7.45 g), shot in pistol or a sub-machine gun. The results demonstrated that the questioned bullet was a lost bullet. The shooting distance also helped the investigators, narrowing the range of the estimated positions of the shooter.  相似文献   

9.
At issue in this case was whether an unusual window defect seen in two of the crime scene photographs was due to a bullet and if so, if that same bullet fatally wounded the victim. The window appeared to have been cracked prior to the apparent shot through it. A .22 bullet recovered from autopsy, when examined only by light microscopy, failed to show associated glass fragments. A previously cracked test window was shot a number of times with .22 caliber bullets near the cracks in an effort to simulate the window defect seen in the crime scene photographs. Several of the defects produced by the test window shots appeared similar to the crime scene window defect. The .22 bullet taken from the victim and several of the test bullets (collected by a cotton box) were examined by scanning electron microscopy/energy dispersive X-ray spectroscopy. The test bullets showed glass particles on and embedded in their surfaces. Particles of similar size and composition were found embedded in the surface of the bullet from the victim. The bullet likely struck the window prior to hitting the victim. It was apparent by the morphology of some of the mushroomed test .22 bullets that they hit the window crack. These bullets showed that the glass on one side of a crack often fails before the other side during the strike. Aggregations of powdered glass on many of the mushroomed surfaces of the .22 bullets suggest that as the bullet mushrooms during impact on the window surface, the glass in contact with the bullet powderizes and coats the mushroomed surface of the bullet with a layer of fine glass particles.  相似文献   

10.
A bystander claimed to have been shot by a police officer, and CT scans were used to match qualitative and quantitative aspects of the unremoved bullet with police issued 9 mm Luger ammunition. CT scan methodology proved a valid approach for the measurement of bullets based on calculated measurement capability and correlation with “gold standard” physical measurement by vernier caliper. Measurements regarding length and base diameter, as well as length/diameter ratio, were insufficient to unambiguously identify a specific caliber, or a bullet of specific mass within a caliber class. It was, however, possible to exclude a bullet of specific design and mass with well‐characterized precision and accuracy values under selected CT scan conditions. A 9 mm Luger bullet (115 gr FMJ RN) was excluded from involvement in a shooting based on qualitative bullet shape combined with length, base, and ratio measurements of the bullet in‐situ for the victim.  相似文献   

11.
Bullet embolism is a well-recognized phenomenon. While bullet embolism is not common, renal artery bullet embolism appears to be very rare. We report three cases of bullet embolism to a renal artery. Autopsy findings and bullet types are presented. Such cases are of particular interest to both the medical examiner and the clinician. Failure to consider this phenomenon clinically could lead to infarction of a kidney. A consideration of this phenomenon at autopsy could shorten the dissection time required to retrieve the bullet.  相似文献   

12.
Radiography is commonly used to find bullet pathways in forensic pathology. In the case presented here, a man had sustained multiple gunshot wounds and one bullet could not be traced. A radiograph was used to find the bullet and showed an interesting bullet pathway. By observing the bullet pathway on a radiograph, sometimes we can surmise the victim's body posture at the time of an incident.  相似文献   

13.
From forensic point of view, it is important to clarify the condition whether ricochet or perforate for a bullet fired toward the automobile windshield. The purpose of this study was to specify the critical angle at which the ricochet of the fired bullet takes place. To estimate the result of firing, a rigid‐body dynamics simulation of the bullet together with the test‐firing using .38 CAL. LRN bullet was examined. It was found both from numerical simulation and firing test that when the incidence angle is <45°, a complete perforation of the windshield was observed, whereas the bullet ricocheted remaining a characteristic damage on the windshield when the incidence angle is >60°. To measure the static failure resistance of various windshields, static indentation test was also examined.  相似文献   

14.
6 years after introduction of the police ammunition QD-P.E.P. (9 mm caliber), 9 bullet wounds are presented from forensic investigations along with the results of experimental shots at pig carcasses. The evaluation reveals the characteristic pattern of such bullet wounds: a skin defect which is almost as large as the caliber and has a sharp-edged border thus looking like it has been punched out; the contusion ring ("abrasion ring") is conspicuously narrow. These findings can be explained by the shape and design of the projectile. In regular police work immediate incapacitation has not always been achieved, depending on the entry location of the bullet. Experimental shots at pig carcasses showed that in the case of shots at extremities, the residual energy of the exiting bullet may be sufficient to generate another penetrating bullet wound.  相似文献   

15.
Establishing the path or trajectory of a fired bullet is an often recurring part of shooting incident reconstruction. The current study describes how gravitational pull causes a systemic error on the vertical component of a trajectory reconstruction. Bullet drop, drop angle, and vertical offset are explained and calculated for 10 different handgun/ammunition combinations over a range of distances up to 100 m. The presented results are intended to provide forensic firearm examiners with a reference frame for the magnitude of error introduced on handgun bullet trajectory reconstructions over distance. Threshold values of 20 and 30 m are proposed as conservative distances up to where bullet trajectories can be modeled as straight lines with subsonic/transonic handgun bullets and with supersonic handgun bullets respectively. Both the bullet drop and vertical offset will be below 5 cm at these distances for those categories. The drop angle will be below 0.3°.  相似文献   

16.
《Science & justice》2019,59(4):390-404
When a bullet is fired from a barrel, random imperfections in the interior surface of the barrel imprint 3-D micro structures on the bullet surface that are seen as striations. Despite being random and non-stationary in nature, these striations are known to be consistently reproduced in a unique pattern on every bullet. This is a key idea in bullet identification. Common procedures in the field of automatic bullet identification include extraction of a feature profile from bullet image, profile smoothing and comparison of profiles using normalized cross correlation. Since the cross correlation based comparison is susceptible to high-frequency noise and nonlinear baseline drift, profile smoothing is a critical step in bullet identification. In previous work, we considered bullet images as nonlinear non-stationary processes and applied ensemble empirical mode decomposition (EEMD) as a preprocessing algorithm for smoothing and feature extraction. Using EEMD, each bullet average profile was decomposed into several scales known as intrinsic mode functions (IMFs). By choosing an appropriate range of scales, the resultant smoothed profile contained less high-frequency noise and no nonlinear baseline drift. But the procedure of choosing the proper number of IMFs to reduce the high-frequency noise effect was manual. This poses a problem in comparison of bullets whose images contained less or more noise in comparison to others because their useful information may be present in the corresponding discarded IMFs. Moreover, another problem arises when the bullet type changes. In this case manual inspection is needed once more to figure out which range of IMFs contain less high-frequency noise for this particular type of bullet. In this paper, we propose a novel combination of EEMD and Bayesian Kalman filter to solve these problems. First the bullet images are rotated using Radon transform. The rotated images are averaged column-wise to acquire averaged 1-D profiles. The nonlinear baseline drifts of averaged profiles are removed using EEMD algorithm. The profiles are then processed by a Kalman filter that is designed to automatically and optimally reduce the effect of high-frequency noise. Using Expectation Maximization (EM) technique, for each averaged profile, the parameters of Kalman filter are reconfigured to optimally suppress the high-frequency noise in each averaged profile. This work is the first effort that practically implements the Kalman filter for optimal denoising of firearm image profiles. In addition, we believe that Euclidean distance metric can help the normalized cross-correlation based comparison. Therefore, in this paper, we propose a comparison metric that is invariant to start and endpoints of firearm image profiles. This metric combines the prized properties of both Euclidean and normalized cross-correlation metrics in order to improve identification results. The proposed algorithm was evaluated on a database containing 180 2-D gray-scale images acquired from bullets fired from different AK-47 assault rifles. Although the proposed method needs more calculations in comparison to conventional methods, the experiments showed that it attained better results compared with the conventional methods and the previous method based on EMD in the field of automatic bullet identification.  相似文献   

17.
Morphological characteristics of gunshot injuries of the cranial dome bones depend on bullet speed and are determined by various mechanisms of the harmful action. A contusion action of the bullet is characterized by disruption of the bone tissue with formation of linear or incomplete fracture. A wedged impact is accompanied with disruption of bone structures with formation of depressed or comminuted fractures due to radial dislocation of the fragments. A perforative impact produces a hole defect the shape of which depends on bullet speed. A bursting impact of the bullet causes disruption of the bone tissue outside the bullet defect as a result of an additional radial effect of high pressure of the air wave reaching in the wounds inflicted by high-speed bullets the effect of the hydrodynamic shock in the spongy layer of the flat bone. Resultant morphological manifestations are aggravated by damage caused by hydrodynamic shock coming from the cranial cavity.  相似文献   

18.
With respect to wound ballistics, the situation is different if the person wearing a military helmet suffers head injuries from a bullet. The mechanisms of injury were investigated in four experimental series and supplemented by a case history. The study showed surprising results: in the majority of cases, the helmet does not protect the wearer, but instead intensifies the damage caused by the bullet. The reasons for this phenomena are changes in the stability of the projectile and deformation of or damage to the bullet. All of these mechanisms result in the bullet striking the tissue with higher energy. In this investigation, Kevlar helmets were also tested, which are not penetrated by 9 X 19 mm parabellum bullets. Even so, however, severe injuries of the skull and brain can occur because the projectile causes intensified impressions on the skull under the helmet and, in addition, an acceleration of the head.  相似文献   

19.
Retained bullets and fragments following a civilian gunshot injury are quite frequent in practical neurosurgery. It is usually possible to extract the foreign body surgically, while rare cases are conservatively treated because of technical reasons. Conservative treatment may present complications, and a rare form of this presentation is migration of the bullet. A 20-year-old man presented with migrating bullet from a supratentorial to opposite infratentorial area. We consider that in the migrating bullet fragment cases, if there is no contraindication, the most reasonable treatment is its urgent surgical removal. This report reveals a supratentorial bullet migrating to the infratentorial contralateral area, and related literature considering the different mechanisms of migration is discussed.  相似文献   

20.
When a bullet punctures a surface, it leaves behind a bullet impact, which can be analyzed in order to determine the origin and trajectory path from which a bullet was discharged using many different scientific methods to reconstruct a shooting scene. The purpose of the research was to test the accuracy and repeatability of reconstructing the impact angle of single bullet impacts using the ellipse method. The research was conducted by firing various calibers of ammunition into drywall panels positioned at varying angles of incidence from 88° until ricochet occurred. This was done in order to determine which caliber type and angle of incidence are most accurate and precise for reconstructing a shooting scene. The study examined four caliber types fired into drywall panels, with 5 repeated shots for each of the 11 angles of incidence (n = 220). Furthermore, 31 participants partook in the study to estimate a bullet impact angle of incidence utilizing the ellipse method. The results show that the best performance (accuracy and repeatability) is seen with the measurements of the 0.45 caliber ammunition. When angle of incidences is low (<64°), the performance (accuracy and repeatability) was seen to be better in all caliber ammunitions. Overall, the data provided for single bullet impacts deposited in drywall show that the ellipse method is useful in providing measurements for most crime scene reconstruction purposes and has also demonstrated that results vary depending on the type of ammunition, firearm, and angle of incidence being examined.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号