首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 359 毫秒
1.
A method based on profiling of dye components by electrospray ionization mass spectrometry (ESI/MS) is described for the characterization of ballpoint pen inks. The method involves benzyl alcohol (30 microL) extraction of ink from paper. The extracts of ink lines 1 and 5 mm in length are used for direct ESI/MS analysis in positive and negative modes, respectively. The instrumental analysis takes 3 min. Basic and acid dyes in the inks are detected in the positive and negative modes, respectively, with each dye yielding one or two characteristic ion peaks. The mass spectrum, which is mainly a compositional signature of the dyes in the ink, was not affected by the type of paper from which the ink was extracted, or by natural ageing of the ink on document in the absence of light. However, exposure to fluorescent illumination caused dealkylation of polyalkylated basic dyes and resulted in changes in the homologous distribution of the dyes. In this study, a total of 44 blue inks, 23 black inks, and 10 red inks have been analyzed, and the mass spectra were used to establish a searchable library. ESI/MS analysis provides a simple and fast way to compare ink specimens and in combination with on-line library search permits rapid screening of inks for forensic document investigations.  相似文献   

2.
Inkjet ink analysis is the best way to discriminate between printed documents, or even though more difficult, to connect an inkjet printed document with a brand or model of printers. Raman spectroscopy and laser desorption mass spectrometry (LDMS) have been demonstrated as powerful tools for dyes and pigments analysis, which are ink components. The aim of this work is to evaluate the aforementioned techniques for inkjet inks analysis in terms of discriminating power, information quality, and nondestructive capability. So, we investigated 10 different inkjet ink cartridges (primary colors and black), 7 from the HP manufacturer and one each from Epson, Canon and Lexmark. This paper demonstrates the capabilities of three methods: Raman spectroscopy, LDMS and MALDI-MS. Raman spectroscopy, as it is preferable to try the nondestructive approach first, is successfully adapted to the analysis of color printed documents in most cases. For analysis of color inkjet inks by LDMS, we show that a MALDI matrix (9-aminoacridine, 9AA) is needed to desorb and to ionize dyes from most inkjet inks (except Epson inks). Therefore, a method was developed to apply the 9AA MALDI matrix directly onto the piece of paper while avoiding analyte spreading. The obtained mass spectra are very discriminating and lead to information about ink additives and paper compositions. Discrimination of black inkjet printed documents is more difficult because of the common use of carbon black as the principal pigment. We show for the first time the possibility to discriminate between two black-printed documents coming from different, as well as from the same, manufacturers. Mass spectra recorded from black inks in positive ion mode LDMS detect polyethylene glycol polymers which have characteristic mass distributions and end groups. Moreover, software has been developed for rapid and objective comparison of the low mass range of these positive mode LDMS spectra which have characteristic unknown peaks.  相似文献   

3.
The technique of principal component analysis has been applied to the UV-vis spectra of inks obtained from a wide range of black ballpoint pens available in the UK market. Both the pen ink and material extracted from the ink line on paper have been examined. Here, principal component analysis characterised each spectrum within a group through the numerical loadings attached to the first few principal components. Analysis of the spectra from multiple measurements on the same brand of pen showed excellent reproducibility and clear discrimination between inks that was supported by statistical analysis. Indeed it was possible to discriminate between the pen ink and the ink line from all brands examined in this way, suggesting that the solvent extraction process may have an influence on these results. For the complete set of 25 pens, interpretation of the loadings for the first few principal components showed that both the pen inks and the extracted ink lines may be classified in an objective manner and in agreement with the results of parallel thin layer chromatography studies. Within each class almost all inks could be individualised. Further work has shown that principal component analysis may be used to identify a particular ink from a database of reference UV-vis spectra and a strategy for developing this approach is suggested.  相似文献   

4.
A novel approach for the identification and dating of the fountain pen ink entries on paper has been established by ion-pairing high-performance liquid chromatography (IP-HPLC). Twelve black and six red fountain inks have been collected, and their ink entries have been prepared by drawing lines on paper. The chromatographic conditions for separation of their dye components after extraction with solvents were optimized. Under the optimized conditions, the 18 fountain pen inks were differentiated individually by comparing the number of detectable main or minor dye components, and the relative peak intensities of each component. The ink entries were artificially and naturally aged, and the analysis results showed that the ink dye components were significantly decomposed when exposed to UV or fluorescent light compare to those of inks stored under natural condition. The changes of the relative peak height for the dye components were linearly related to the aging time, especially under natural aging conditions. The degradation characteristics of the dye components under different aging conditions provide scientific evidences for dating of the suspicious fountain pen ink entries on document.  相似文献   

5.
Gel ink pens have become a common writing instrument in the United States. Questioned document examiners often attempt to optically differentiate gel inks from each other and from other non-ballpoint ink writings (e.g., those from roller-ball pens). Since early formulations were primarily pigment-based, they do not elute when analyzed by thin-layer chromatography. However, recent gel ink formulations (i.e., within the past five years) include dye-based inks that can be easily separated. This study differentiates black gel inks using optical and chemical techniques. The techniques include: microscopy, visible and near infrared reflectance, near infrared luminescence, thin-layer chromatography (TLC), spot tests, and gas chromatography/mass spectrometry (GC/MS). As a result of this study a flow chart has been developed allowing for a systematic determination of a questioned ink. In addition, an analysis of volatile compounds found in gel inks revealed that there are some unique ingredients that may be found in gel inks that are not typically found in other non-ballpoint inks.  相似文献   

6.
Pigments are rapidly replacing dyes as colorants in pen and printer inks, due to their superior colors and stability. Unfortunately, tools commonly used in questioned document examination for analyzing pen inks, such as TLC, cannot be used for the analysis of insoluble pigments on paper. Laser desorption mass spectrometry is demonstrated here as a tool for analyzing pigment-based pen inks. A pulsed nitrogen laser can be focused onto a pen stroke from a pigmented ink pen on paper, and positive and negative ions representative of the pigment can be generated for subsequent mass spectrometric analysis. Targeted pens for this work were a set of Uni-ball 207 pigmented ink pens containing blue, light blue, orange, green, violet, red, pink, and black inks. Copper phthalocyanine was identified as the pigment used to make both blue inks. A mixture of halogenated copper phthalocyanines were identified in the green ink. Unexpectedly, the pink ink was found to contain a red pigment, Pigment Red 12, treated with a mixture of water-soluble dyes. Each sample yielded ions representative of the pigments present.  相似文献   

7.
The sequence of intersecting strokes of laser printers (black, blue, red and green) and typewriter ink (black) with the strokes of gel pen ink, ballpoint pen ink and fountain pen ink (black, blue, red and green) has been determined by studying their absorption spectra. The absorption spectra have been generated for each of the two pure inks (i.e. A and B) and points of their intersections (i.e. A over B and B over A) by using Video Spectral Comparator (VSC-2000-HR). The study was carried out with an assumption that the peak characteristics of spectra from the point of intersection should correspond to the peak characteristics of pure ink which was executed later. It was observed that the absorption spectrum of intersection corresponds with either the laser printer or the typewriter ink stroke, whether these strokes were executed earlier or later than the writing instrument strokes. As the results obtained from the study were negative, the FDEs are advised against the practice of this technique in the examination of the sequence of intersecting strokes for these specified inks.  相似文献   

8.
9.
This study applies Raman microspectroscopy to differentiate the chemical components in printing inks of different brands, colors, and type using the 532 nm and 785 nm excitation wavelengths. Spectra were collected from 319 inks (78 inkjet, 76 toner, 79 offset, and 86 intaglio) representing various colors. Comparisons were performed to calculate discrimination capability percentages for each ink type. Overall, Raman microspectroscopy differentiates according to the following hierarchy: intaglio (96%), inkjet (92%), offset (90%), and toner (61%). The ability of Raman microspectroscopy to differentiate between same‐colored inks from different brands was dependent on the color and ink analyzed. Based on ink color, the discrimination capability ranged from 75 to 94% (inkjet), 0 to 86% (toner), and 0 to 77% (offset). Copper phthalocyanine was detected in cyan inks and various intaglio inks, while carbon black was identified in black inkjet, offset, and intaglio inks.  相似文献   

10.
Developing and implementing a generally accepted procedure for the dating of ink found on documents using dynamic approaches has been a very formidable undertaking by forensic document examiners. 2-Phenoxyethanol (PE), a common volatile organic compound found in ballpoint inks, has been recognized for over a decade as a solvent that evaporates as ink ages. More recently, investigations have focused on the solvent loss ratio of PE prior to and after heating. To determine how often PE occurs in ink formulations, the authors analyzed 633 ballpoint inks utilizing a gas chromatograph/mass spectrometer. 2-Phenoxyethanol was identified in 85% (237/279) and 83% (293/354) of black and blue inks, respectively.  相似文献   

11.
The ageing process of some inks were studied to evaluate whether it is possible to date them. We used gas chromatography coupled with mass spectrometry to measure the evaporation of volatile components. The selected approach thus follows the disappearance of one ink volatile component (phenoxyethanol) as a function of time. The ink ageing curve represents the ratio of an evaporating compound to a stable compound of ink according to time. The results obtained are thus independent of the quantity of ink sampled for analysis. We obtained for two pens, containing two different inks, a curve highlighting an exponential decrease of the evaporating compound. By fitting these curves we determined the limitations of dating a ballpoint pen ink. Two distinct behaviours were observed in two distinct modes, the first called 'fast mode' and the second called 'slow mode'. In order to try to explain the phenomenon, the studies were based on solvent diffusion theory in complex matrix (such as polymer on varnish). Calculations from certain parameters showed an extremely fast evaporation of ink solvents, as well as varying behaviour depending on the paper used. The results showed that it is not possible to date ballpoint pen inks with this method in document examination casework.  相似文献   

12.
A statistical methodology for the objective comparison of LDI-MS mass spectra of blue gel pen inks was evaluated. Thirty-three blue gel pen inks previously studied by RAMAN were analyzed directly on the paper using both positive and negative mode. The obtained mass spectra were first compared using relative areas of selected peaks using the Pearson correlation coefficient and the Euclidean distance. Intra-variability among results from one ink and inter-variability between results from different inks were compared in order to choose a differentiation threshold minimizing the rate of false negative (i.e. avoiding false differentiation of the inks). This yielded a discriminating power of up to 77% for analysis made in the negative mode. The whole mass spectra were then compared using the same methodology, allowing for a better DP in the negative mode of 92% using the Pearson correlation on standardized data. The positive mode results generally yielded a lower differential power (DP) than the negative mode due to a higher intra-variability compared to the inter-variability in the mass spectra of the ink samples.  相似文献   

13.
Questioned document examiners are frequently required to determine whether the questioned ink entries on a document are written with the same ink, either for forged document identification or relative ink dating. How many methods are sufficient to discriminate potentially different inks? In this paper, 18 blue ballpoint inks were first nondestructively examined with a video spectral comparator. The ink entries were subsequently extracted with organic solvents for analysis of the volatile solvents and dyes by GC/MS, TLC, and LC‐MS/MS. The 18 ink samples were divided into 10, 9, 12, and 14 categories by these four methods, respectively. With the combined results, there were only two inks that remained indistinguishable, but they were further differentiated by microscopy. Therefore, to achieve effective discrimination of ballpoint ink entries, the authors suggest that a complete examination should include an analysis of their optical features, volatile solvents, and dyes as well as the ink quality.  相似文献   

14.
Raman microscopy is becoming a tool of major importance in forensic analysis, particularly of drugs and explosives. It is a non-invasive, non-destructive chemical probe allowing samples to be examined in their entirety without any preparation. This paper demonstrates the use of the technique as a general tool for inks analysis. Furthermore, it addresses two important issues that historically have been extremely difficult for the professional document examiner, namely, comparison of black ballpoint inks and the chronological sequencing of crossed ink lines. We show that Raman can successfully distinguish between a representative sample of commercially available black ballpoint inks. This data has been converted into a database for future reference. A method for chronological sequencing of crossed ink lines has been developed using confocal Raman microscopy. Case study work has shown the feasibility of this approach.  相似文献   

15.
Pearson correlation coefficients were applied for the objective comparison of 30 black gel pen inks analysed by laser desorption ionization mass spectrometry (LDI-MS). The mass spectra were obtained for ink lines directly on paper using positive and negative ion modes at several laser intensities. This methodology has the advantage of taking into account the reproducibility of the results as well as the variability between spectra of different pens. A differentiation threshold could thus be selected in order to avoid the risk of false differentiation. Combining results from positive and negative mode yielded a discriminating power up to 85%, which was better than the one obtained previously with other optical comparison methodologies. The technique also allowed discriminating between pens from the same brand.  相似文献   

16.
The ink of pens and ink extracted from lines on white photocopier paper of 10 blue ballpoint pens were subjected to ultraviolet-visible (UV-Vis) spectroscopy, infrared (IR), and high-performance thin-layer liquid chromatography (HPTLC). The R(f) values and color tones of the bands separated by thin-layer chromatography (TLC) analysis used to classify the writing inks into three groups. The principal component analysis (PCA) investigates the pen responsible for a piece of writing, and how time affects spectroscopy of written ink. PCA can differentiate between pen ink and ink line indicates the influence of solvent extraction process on the results. The PCA loadings are useful in individualization of a questioned ink from a database. The PCA of ink lines extracted at different times can be used to estimate the time at which a questioned document was written. The results proved that the UV-Vis spectra are effective tool to separate blue ballpoint pen ink in most cases rather than IR and HPTLC.  相似文献   

17.
Seals are often placed on important documents, and determining the date when a seal was affixed can be important to assess the authenticity of a document. In this study, thirty‐seven different brands of stamp‐pad inks and three different types of paper were used to make diachronic samples of the seals. The volatile components of stamp‐pad ink were determined, and the stamp‐pad ink was classified by gas chromatography with a flame ionization detector. Calibration curves were created to show the relationship between the content of volatile stamp‐pad ink components and the age of stamp‐pad ink entries stored under natural aging, UV‐induced aging, and heating aging conditions. The experimental results showed that GC was useful in the analysis of stamp‐pad ink and applicable for determining the relative age of stamp‐pad ink entries in some cases where the seal was placed on the document within 3 months.  相似文献   

18.
Improvements in printing technology have exacerbated the problem of document counterfeiting, prompting the need for analytical techniques that better characterize inks for forensic analysis and comparisons. In this study, 319 printing inks (toner, inkjet, offset, and Intaglio) were analyzed directly on the paper substrate using scanning electron microscopy‐energy dispersive spectroscopy (SEM‐EDS) and Laser Ablation‐Inductively Coupled Plasma‐Mass Spectrometry (LA‐ICP‐MS). As anticipated, the high sensitivity of LA‐ICP‐MS pairwise comparisons resulted in excellent discrimination (average of ~ 99.6%) between different ink samples from each of the four ink types and almost 100% correct associations between ink samples known to originate from the same source. SEM‐EDS analysis also resulted in very good discrimination for different toner and intaglio inks (>97%) and 100% correct association for samples from the same source. SEM‐EDS provided complementary information to LA‐ICP‐MS for certain ink types but showed limited utility for the discrimination of inkjet and offset inks.  相似文献   

19.
The differentiation of inks on a questioned document can highlight a fraudulent insertion and is usually carried out by optical comparison and thin-layer chromatography (TLC). Laser desorption ionization mass spectrometry (LDI-MS) may also be used for the analysis of dyes from ink. This analytical technique was compared with a standard method of high-performance TLC (HPTLC) according to their capacity to differentiate blue ballpoint inks. Ink entries on paper from 31 blue ballpoint pens have been analyzed and their dye ink formulations compared. The pens were classified into 26 classes by LDI-MS against 18 for HPTLC. LDI-MS proved to be a more powerful method for differentiating ink formulations because it provides information about dye structures (molecular weights) and relative quantification of dye classes (peak areas). Sample preparation was minimal and analysis time was short in contrast to the more complex extraction, application, and development steps of the HPTLC method. However, only basic dyes and pigments were identified using positive mode LDI-MS, while HPTLC did yield additional information about acid dyes.  相似文献   

20.
Stamp pad inks from different manufacturers across India have been analyzed to investigate the feasibility of Raman scattering as a tool for forensic analysis of questioned documents involving stamp inks. Nine different stamping inks were analyzed by both Raman spectroscopic and HPTLC methods. The results demonstrate the effectiveness of these methods in classifying the investigated stamping inks based on their spectral pattern and HPTLC chromatogram. Raman scattering tool was able to determine the sequence of heterogeneous intersection strokes involving a blue stamp pad ink and other writing instruments, such as ballpoint pen ink (red and black), pencil and laser printer toner. However, this method was unable to resolve the exact sequencing for the intersection strokes involving investigated stamp ink and blue ballpoint ink or gel pen ink (all colors).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号