首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An accurate and reproducible technique was employed for the determination of the resistivity of excised portions of the anterior abdominal wall of rats. Resistivity decreased linearly (r = −0.93; P < 0.001) from 1438 ± 131 Ω · cm, immediately following death, to 360 ± 144 Ω · cm at a postmortem interval of 36 h. These changes are believed to reflect the morphological and/or chemical changes which occur at the cellular level during the early postmortem period.  相似文献   

2.
Total (Zt) and extracellular (Ze) abdominal impedances of putrefying rat cadavers, stored at 18.0±0.7°C, were measured at 50 kHz and at 1 kHz, respectively, during the first 7 days of death. Transcellular impedance was calculated from the measured values of Zt and Ze. Total impedance and Ze increased during the first day, and then decreased with increasing postmortem interval, while Zi remained unchanged during the first 3 days before increasing more than 4-fold between 3 and 7 days postmortem. These changes are consistent with net gain of electrolyte by the extracellular fluids and with degeneration of cell membranes which occur postmortem. It is concluded that, during putrefaction, Ze is a potentially more useful index of postmortem interval than Zt or Zi, and that measurement of total abdominal impedance at 50 kHz, rather than at 10 kHz, markedly improves the precision and accuracy of impedance measurement.  相似文献   

3.
The different statements concerning the slope and intercept of the regression line and the 95% limits of confidence are the reason that potassium in vitreous humor is not used (at least in Germany) as an aid in estimating the time of death. The relationship between the concentration of potassium and the time of death is mainly influenced by antemortem electrolyte imbalances caused by disease and/or duration of terminal episode. The influence of terminal episode is best identified by its duration (Adelson et al., J. Forensic Sci., 8 (1963) 503–514). In order to have a method suitable for every case and to be as precise as possible we looked therefore for parameters in vitreous humor which were stable postmortem and indicating antemortem electrolyte imbalance. Urea is such a parameter, being stable postmortem (Coe, Am. J. Clin. Pathol., 51 (1969) 741–750) and useful as a marker of antemortem electrolyte imbalance. Our investigations on potassium in vitreous humor, including sudden and hospital deaths after chronic lingering disease, revealed 95% limits of confidence of ±34 h up to 120 h postmortem. Reviewing only cases with urea less than 100 mg/dl the 95% limits of confidence could be reduced to ±22 h. Considering the duration of terminal episode (<6 h) the precision was ±20 h. In this way our modified procedure is suitable for every case with the resulting precision of estimation being determined only by the duration of the terminal episode and urea concentration.  相似文献   

4.
Because serum Procalcitonin is reported to be a valid postmortem marker of sepsis, this prospective study was carried out to determine whether the semi-quantitative PCT-Q((R))-Test (B.R.A.H.M.S., Germany) is a reliable indicator of postmortem Procalcitonin (PCT) serum levels, thus enabling a quick "tableside" diagnosis of sepsis. Postmortem PCT-levels of 70 forensic and 78 clinical-pathological autopsy cases (n=148) were examined using the B.R.A.H.M.S-PCT-Q-Test during autopsy. 27 cases were categorized as the cases of sepsis according to the ACCP/SCCM Consensus Conference criteria. 121 cases were assigned to the non-sepsis group. Among the 148 cases, 18 samples could not be analyzed by the reason of strong hemolysis. Using a cut-off point of 2 ng/ml, 20 cases of sepsis were identified (true positive) whereas 3 cases of sepsis were not detected (false negative). In the non-sepsis group (107 cases) 6 cases showed a positive testing (false positive). When applied within 48 h postmortem, the PCT-Q-Test showed a sensitivity of 86.96% and a specificity of 94.39% (at cut-off 2 ng/ml). Likelihood ratios and positive predictive values proved to be lower in the forensic autopsy group (PPV: 59.3% in forensic case vs. 85.1% in clinicopathological cases; NPV: 98.73% in forensic cases vs. 95.2% in clinicopathological cases). The PPVs using a cut-off point of 10 ng/ml were 100% in both groups independent of sepsis prevalences. The results show, that a high NPV for prevalences ranging from 3% to 30% can be reached using a 2 ng/ml cut-off point, whereas a cut-off of 10 ng/ml ensures a high PPV for the respective prevalences in the absence of exclusion criteria. The study provides strong evidence that the introduction of rapid diagnostic test (RDTs) of postmortem PCT serum levels may be useful in achieving rapid distinction between sepsis and non-sepsis-related causes of death, especially in conjunction with the medical case history and further autopsy results. In addition, the use of RDTs enables clinicians to conduct an evidence-based validation of clinical diagnosis, thus facilitating future clinical decision-making.  相似文献   

5.
6.
Estimating the postmortem interval of skeletal remains is difficult, as few tools exist to do so. To address this problem, we conducted a field experiment to measure the chemistry of swine (Sus scrofa domesticus Linnaeus) gravesoil after 1 year and 3 years postmortem. Carcasses were placed on the soil surface of a pasture during June in a cold (Dfa) climate. Significant (p < 0.05) increases in ninhydrin‐reactive nitrogen, pH, total nitrogen, and nitrate in gravesoil were detected 1 year postmortem. Significant differences in gravesoil chemistry were not detected 3 years postmortem. These observations coincided with gaps in plant growth 1 year postmortem and the development of lush vegetation 3 years postmortem. We conclude that these phenomena can be used to assist the decision‐making process regarding the allocation of resources during the early stages of a death investigation.  相似文献   

7.
The aim of our study was to investigate the postmortem levels of glucose and glycogen in hepatic, renal, muscle, and brain tissues and then examine the changes in those levels that could be useful for estimating postmortem interval. We established an animal model. Seventy female BALB/c albino mice were used in this study. After being sacrificed, the mice were randomly divided into six groups according to time elapsed since death (Group 1: 0 h; Group 2: 12 h; Group 3: 24 h; Group 4: 36 h; Group 5: 48 h; and Group 6: 60 h). Glucose levels were significantly different between groups for all tissues studied. Slope of the change per unit time was higher for the hepatic glucose levels. Based on these results, it is possible to estimate postmortem interval using postmortem glucose levels in hepatic tissue. Tissue‐specific assessment may contribute valuable information to postmortem interval studies.  相似文献   

8.
Opioid‐related mortality happens, even in healthcare settings. We describe serial postmortem fentanyl blood concentrations in a hospital inpatient who fatally abused transdermal fentanyl. This is a single‐patient case report. A 42‐year‐old man with lymphoma was started on transdermal fentanyl therapy while hospitalized for chronic abdominal pain. The patient was last seen awake 1.3 h prior to being found apneic and cyanotic. During the resuscitation attempt, a small square‐shaped film was removed from the patient's oropharynx. Femoral blood was collected 0.5 and 2 h postmortem, and the measured fentanyl concentration increased from 1.6 to 14 ng/mL. Study limitations include potential laboratory or collection errors and missing data. (i) Providers must be vigilant for signs of fentanyl patch abuse. (ii) Postmortem blood concentrations are not static postmortem, likely secondary to decreasing pH, increased aqueous solubility, and tissue redistribution, and are therefore unlikely to accurately represent antemortem blood concentrations.  相似文献   

9.
The changes of postmortem corneal opacity are often used to roughly estimate the postmortem interval (PMI) in forensic practice. The difficulty associated with this time estimate is the lack of objective means to rapidly quantify postmortem corneal changes in crime scenes. This study constructed a data analysis model of PMI estimation and implemented an intelligent analysis system for examining the sequential changes of postmortem corneal digital images, named Corneal‐Smart Phone, which can be used to quickly estimate PMI. The smart phone was used in combination with an attachment device that provided a darkroom environment and a steady light source to capture postmortem corneal images. By segmenting the corneal pupil region images, six color features, Red (R), Green (G), Blue (B), Hue (H), Saturation (S), Brightness (V) and four texture features Contrast (CON), Correlation (COR), Angular Second Moment (ASM), and Homogeneity (HOM), were extracted and correlated with PMI model. The results indicated that CON had the highest correlation with PMI (R2 = 0.983). No intra/intersubject variation in CON values were observed (p > 0.05). With the increase in ambient temperature or the decrease in humidity, the CON values were increased. PMI prediction error was <3 h within 36 h postmortem and extended to about 6–8 h after 36 h postmortem. The correct classification rate of the blind test samples was 82%. Our study provides a method that combines postmortem corneal image acquisition and digital image analysis to enable users to quickly obtain PMI estimation.  相似文献   

10.
2‐(4‐Bromo‐2,5‐dimethoxyphenyl)‐N‐(2‐methoxybenzyl)ethanamine (25B‐NBOMe) is a substituted phenethylamine, which has become highly prevalent worldwide since 2014. Recently, in an autopsy case involving fatal 25B‐NBOMe intoxication, we found the postmortem increase of 25B‐NBOMe concentration in the cardiac blood approximately 2 days after death. The aim of this study was to investigate the distribution of 25B‐NBOMe and reproduce the postmortem redistribution using a rat model. Sprague‐Dawley rats were killed 30 min after intraperitoneal injection of 25B‐NBOMe (0.5 mg/kg) and left for 0, 3, 6, 9, 15, or 24 h (six rats at each time point). Postmortem 25B‐NBOMe concentrations in the cardiac blood increased by more than 10‐fold at 6‐h postmortem. 25B‐NBOMe accumulated primarily in the lung. Moreover, this postmortem redistribution occurred even in rats that had died 1 week following the 25B‐NBOMe administration. These findings indicate that attention should be paid to sample collection and data interpretation in the toxicological analysis of 25B‐NBOMe.  相似文献   

11.
Currently, SEM-EDS is used to detect gunshot residue (GSR) from the presence of Ba, Pb, and Sb in the sample. However, the development of new nontoxic ammunition (NTA) has prevented conventional metals from being found. In this work, we aim to determine the presence of an inorganic luminescent chemical marker based on rare earth in gunshot residues using the technique of squarewave voltammetry (SWV). After firing, the luminescent complex [(Eu2Zr)(btc)3(Hbtc)0.5.6H2O], which is used as a chemical marker, can be detected under a UV lamp. An aqueous solution with 0.1 mol L−1 KCl as supporting electrolyte can be easily collected on carbon paste electrode surfaces for SWV analysis A = 100 mV, f = 10 Hz, and step potential of 5 mV are required. The luminescent marker incorporated into the carbon paste electrode showed two anodic peak currents in the region of 0.4 V (vs Ag/AgCl) and at 0.75 V (vs Ag/AgCl) and also a cathodic one in 0.4 V (vs Ag/AgCl). SEM-EDS was able to analyze the same voltammetric results for conventional and nontoxic ammunition containing the luminescent marker. Therefore, voltammetry and SEM-EDS are valid for detecting the new residue marker in GSR. Despite this, the electrochemical method is still more advantageous because of its low cost and lack of expensive equipment and supplies in forensic laboratories.  相似文献   

12.
Estimating postmortem interval (PMI) of surface found skeletal remains is challenging. This novel study used UV‐Vis‐NIR spectroscopy to scan soil collected from cadaver decomposition islands (CDIs) ranging from 15‐ to 963‐d postmortem and control soils. A decomposition product spectra model (DPS model) was constructed by deducting the control soil spectra from the CDI soil spectra for the estimation of postmortem indices: PMI (d), ADD4, ADD10, and ADD20. The DPS model (n = 55) was calibrated and subjected to a full cross‐validation. Calibration R2 and RPD for the DPS model ranged from 0.97 to 0.99 and from 6.1 to 9.9, respectively, for the four postmortem interval indices. Validation R2 and RPD for the DPS model ranged from 0.73 to 0.80 and from 1.9 to 2.2, respectively. The DPS model estimated postmortem intervals for three test CDIs in a clay soil under perennial grassland (test set 1; n = 3) and six CDIs in a sandy soil under a loblolly pine forest (test set 2; n = 6). Test set 1 had PMI prediction ranges from ?69 to ?117 days, ?796 to +832 ADD4, +552 to +2672 ADD10, and ?478 to ?20 ADD20 of observed PMI. Test set 2 PMI prediction ranged from ?198 to ?65 days, ?9923 to +2629 ADD4, ?6724 to +1321 ADD10, and ?2850 to +540 ADD20 of observed PMI. Test set 2 had poor predictions for two CDIs, for all measures of postmortem indices resulting in discussion of sampling depth, effect of body mass index (BMI), and scavenging.  相似文献   

13.
Dentin translucency measurement is an easy yet relatively accurate approach to postmortem age estimation. Translucency area represents a two‐dimensional change and may reflect age variations better than length. Manually measuring area is challenging and this paper proposes a new digital method using commercially available computer hardware and software. Area and length were measured on 100 tooth sections (age range, 19–82 years) of 250 μm thickness. Regression analysis revealed lower standard error of estimate and higher correlation with age for length than for area (= 0.62 vs. 0.60). However, test of regression formulae on a control sample (= 33, 21–85 years) showed smaller mean absolute difference (8.3 vs. 8.8 years) and greater frequency of smaller errors (73% vs. 67% age estimates ≤ ±10 years) for area than for length. These suggest that digital area measurements of root translucency may be used as an alternative to length in forensic age estimation.  相似文献   

14.
The aim of this study was to clarify whether positive results for prostate‐specific antigen (PSA) and acid phosphatase (AP) occur in postmortem swabs from the genito‐anal region in males (n = 80; 4 regions) and females (n = 20; 3 regions) and to calculate the positive predictive value (PPV) concerning the presence of spermatozoa. In male subjects, the highest incidence of positive test results was found in urethral swabs (PSA 76%, AP 71%) and the lowest frequencies appeared in perianal and rectal swabs (15–20%). Microscopic evaluation for spermatozoa was positive between 39% in urethral swabs and 1% in rectal swabs. PPV regarding positive identification of spermatozoa was 33.3% for PSA and 31.5% for AP. The combination of both tests yielded a PPV of 38.2%. In female cases, no spermatozoa were identified, and one case was PSA‐ and AP‐positive in perianal swabs. Our findings indicate that PSA and AP tests are of limited value for the postmortem detection of spermatozoa in male subjects.  相似文献   

15.
Adult male Sprague Dawley rats were euthanized and placed in a horizontal or vertical (head‐down) position at room temperature, after which brain fluid content was measured by a moisture analysis technique at variable time points. No significant difference in brain fluid content was observed between horizontal and vertical postmortem positions. A significant increase in brain fluid content was demonstrated 3, 6, and 24 h after death, with maximal fluid content observed at 24 h. Specifically, the brain fluid content of control animals was 77.79 ± 0.36%, increasing to 80.05 ± 0.22% at 24 h (p < 0.0001). This study has demonstrated no significant differences in brain fluid content related to postmortem position, suggesting that a head‐down position is not associated with increased brain fluid content or swelling. However, significant temporal increases in brain fluid content after death, most likely related to cerebral liquefaction, occur.  相似文献   

16.
An HPLC‐DAD method was developed to detect and quantify a neonicotinoid insecticide acetamiprid (ATP) and its metabolite IM‐1‐2 in autopsy samples of a fatal intoxication case. The postmortem blood and tissue distribution of ATP and IM‐1‐2 was determined for the first time. The method showed acceptable precisions and recoveries with relative standard deviations of <10% for ATP level and 1.38 % for IM‐1‐2. The detection and quantification limits for ATP were 0.015 μg/mL and 0.030 μg/mL for blood and were 0.035 μg/g and 0.050 μg/g for liver samples, respectively. The mean contents of ATP were 0.79 μg/g in the liver, 47.35 μg/g in the stomach contents and 2.7 μg/mL in the blood. IM‐1‐2 content was 17.0 μg/g in the stomach contents. ATP and IM‐1‐2 were not detected in the urine. The presence of ATP and IM‐1‐2 in the samples was confirmed by GC‐MS. The method can be exploited in future forensic casework.  相似文献   

17.
We studied (May–September 2014) all arrestees who reported mental health issues during the medical examination performed by a forensic physician for the assessment of fitness for detention. Among 4814 arrestees, 420 (9%) reported a current mental health issue. The suspected crimes among arrestees reporting a current mental health issue were more often related to violent behaviors (physical assault, 23% vs. 16%, p < 0.001, sexual assault, 3% vs. 1%, p = 0.01) and less often drug offenses (18% vs. 29%, p < 0.001). Among arrestees reporting mental health issues, 80% reported psychiatric or psychological care, of whom 33% reported previous mental health care. Decisions of unfitness for detention were more frequent among arrestees reporting mental health issues than in other detainees (3% vs. 1%, p < 0.001). The high proportion of patients with interrupted mental health care among those reporting mental disorders suggests that the medical examination during custody could be a significant opportunity to restore psychiatric care.  相似文献   

18.
Postmortem stability of cyanide biomarkers is often disputed. We assessed the time and temperature-dependent changes in cytochrome c oxidase (CCO) activity and cyanide concentration in various organs of mice succumbing to cyanide. Immediately after death, excised mice organs and mice cadavers were stored at room temperature (35°C ± 5°C) or in frozen storage (−20°C ± 2°C). At various times after death, CCO activity and cyanide concentrations were measured in excised mice organs or organs removed from mice cadavers. The study revealed that (i) measuring both the biomarkers in mice cadavers was more reliable compared to excised mice organs, (ii) measuring temporal CCO activity and cyanide concentration in vital organs from mice cadavers (room temperature) was reliable up to 24 h, and (iii) CCO activity in the brain and lungs and cyanide concentration in organs from mice cadavers (frozen) were measurable beyond 21 days. This study will be helpful in postmortem determination of cyanide poisoning.  相似文献   

19.
目的观测生前溺死与死后抛入河水中大鼠肺组织水通道蛋白-1(aquaporin-1,AQP-1)、AQP-4的表达变化。方法将30只健康雄性Wistar大鼠随机分为河水溺死组、抛尸入水组及脱颈致死组。HE染色观察各组大鼠肺组织形态学变化,实时荧光定量PCR法检测各组大鼠肺组织AQP-1、AQP-4 m RNA的表达,免疫组织化学、Western印迹法检测其蛋白表达。结果免疫组织化学法和Western印迹法检测河水溺死组AQP-1蛋白的表达高于抛尸入水组和脱颈致死组(P0.05)。免疫组织化学法显示河水溺死组AQP-4蛋白的表达高于抛尸入水组和脱颈致死组(P0.05),而Western印迹法未检测出三者的差别(P0.05)。河水溺死组大鼠肺组织的AQP-1、AQP-4 m RNA表达高于抛尸入水组(P0.05)。结论河水溺死组的大鼠在急性肺损伤时肺组织AQP-1、AQP-4 mRNA及蛋白表达增高可能对生前溺死与死后抛尸的鉴别有一定意义。  相似文献   

20.
The use of magnesium as a parameter to estimate the time of death is controversial. In 32 traumatic deaths with known postmortem intervals (PMIs), small quantities of vitreous humor (VH) were sampled repetitively every 3 h until 24 h postmortem. The bodies were kept at the constant ambient temperature of 20°C (68°F). The concentrations of magnesium were in the range of 0.47–1.15 mM. A statistically significant correlation of the concentration of magnesium with the PMI was observed (r = 0.453, < 0.01), but with small predictive value—coefficient of variation for regression was 45.5%; the average of the paired differences between the estimated and actual PMIs was 5.24 + 3.19 h. Although useful results might be expected due to the large transmembrane gradient for magnesium, the results of this study strongly disprove the usefulness of measuring magnesium in VH to estimate the time of death.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号