首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Urine immunoassays are commonly used as a rapid screen for drugs of abuse in emergency room, hospital, clinic, and forensic settings. The authors were concerned whether or not a negative screen of the urine for opiates was of significance and indicative that analysis of blood for opiates was not necessary. Specifically, we wished to determine whether a negative test for opiates by immunoassay absolutely rules out an acute overdose, and if not, what percentage of cases with negative results have opiates in the blood. A retrospective analysis was performed using the toxicology results for cases ruled an acute narcotic overdose at the Bexar County Medical Examiner's Office between 1998 and 2003. One hundred eighty-three cases met the criteria for the study. A false-negative rate of approximately 15% was found using an immunoassay as compared with blood analysis for narcotics. The authors feel that while this rate may be acceptable in a clinical setting, it is unacceptable in a forensic setting.  相似文献   

2.
Screening for drugs in forensic blood samples using EMIT urine assays   总被引:1,自引:0,他引:1  
A screening method for the detection of drugs in haemolysed whole blood has been evaluated. Methanolic extracts of 300 forensic blood samples known to be positive or negative for drugs were analysed with EMIT d.a.u. assay kits for amphetamine, cannabinoids, opiates and benzodiazepines (the latter to analyse for diazepam and the main metabolite N-desmethyldiazepam). There were very few false positive results, except for the amphetamine assay in postmortem blood samples, where 9% were false positive. For amphetamine and cannabinoids a few false negatives were found, these were from samples with very low drug concentrations. No false negatives were found for opiates and diazepam. The present modification of the EMIT d.a.u. method seems to be a good method for screening of drugs in forensic blood samples, except for amphetamine in postmortem samples. The method is simple and requires only 0.5 ml blood.  相似文献   

3.
Several immunoassay methods for screening of abused drugs in whole blood were evaluated in post-mortem forensic toxicology. Blood samples known to be positive or negative for opiates, cannabinoids or amphetamines by gas chromatography-mass spectrometry (GC-MS) were analysed by EMIT II Plus and EMIT d.a.u., Syva RapidTest and Triage 8 after acetone precipitation. In these experiments, the EMIT immunoassay method was modified by using the Dade Behring VIVA analyser to detect substances more sensitively. Low concentrations of abused drugs were detected in blood samples. The sensitivities of the modified EMIT method for opiates, cannabinoids and amphetamines were 100, 86 and 98%, respectively, whereas the values were below 86% with the other methods. The specificities of all immunoassay methods for opiates and cannabinoids were 83% or above but 51-85% for amphetamines. Sample rejection occurred in a few cases with the EMIT amphetamine assays. The modified EMIT immunoassay system presented here seems to be useful for screening of drugs of abuse in post-mortem blood samples, especially when urine is not available.  相似文献   

4.
The objective of this study was to develop a two-step strategy for analysis of opiates and cocaine in hair samples involving an immunological screening procedure followed by confirmation of results using gas chromatography-mass spectrometry (GC-MS). A semi-quantitative automated competitive enzyme-linked immunosorbent assay (ELISA) methodology using Oral Fluid Micro-Plate Enzyme Immunoassays (Orasure Technologies, Inc.) was developed and validated. Applicability was proven by analysis of authentic head hair samples from drug users (n=103) and from opiate associated fatalities (n=21). The optimum cutoff values for the ELISA tests were 0.1 ng cocaine-equivalents/mg hair and 0.05 ng morphine-equivalents/mg hair using a 50 mg hair sample. Both ELISA tests had a sensitivity of 100%, the specificity was 66% for cocaine-equivalents and 42% for morphine-equivalents. The intraassay precision was 11% for the cocaine and 3% for the opiates ELISA, while interassay precision was 12% for the cocaine and 4% for the opiates ELISA test. The actual analyte concentrations in the hair samples were determined using GC-MS and were between 0.04 and 5.20 ng/mg for heroin (HER), between 0.04 and 30.01 ng/mg for 6-monoacetylmorphine (MAM), between 0.03 and 11.87 ng/mg for morphine (MOR), between 0.02 and 1.84 ng/mg for codeine (COD), between 0.02 and 2.48 ng/mg for acetylcodeine (AC), between 0.01 and 21.37 ng/mg for cocaine (COC), between 0.03 and 10.51 ng/mg for benzoylecgonine (BE) and between 0.05 and 1.26 ng/mg for cocaethylene (CE). The automated ELISA tests were proven to be valid screening procedures for the detection of cocaine and opiates in hair as confirmed by GC-MS. Screening methods provide rapid and inexpensive automated pre-test procedures to detect drugs in hair or other matrices. For forensic purposes screening therefore represents an ideal complement to routinely applied GC-MS procedures.  相似文献   

5.
Abstract:  Three cases are reported of elevated postmortem blood morphine concentrations (189–3036 ng/mL) that were observed during the course of death investigations involving three children ranging in age from 1 week to 2 years, all of whom underwent withdrawal of life support. In all three cases, the presence of opiates in postmortem blood was indicated by immunoassay (ELISA) and quantitative confirmatory analysis of free morphine concentrations in postmortem blood was performed by solid-phase extraction followed by gas chromatography/mass spectrometry (GC/MS) in the selected ion monitoring mode. While the practice of withdrawing life support from terminally ill patients, with the accompanying administration of narcotics/analgesics has been reported in the medical literature, it has not been adequately described in the forensic literature. The implications of this practice on the forensic toxicological interpretation of morphine findings are discussed. To our knowledge, this is the first report of postmortem morphine concentrations arising directly from administration in conjunction with withdrawal of care in pediatric patients.  相似文献   

6.
Tramadol is a centrally acting synthetic analgesic with mu-opioid receptor agonist activity, it is a widely prescribed analgesic used in the treatment of moderate to severe pain and as an alternative to opiates. Tramadol causes less respiratory depression than morphine at recommended doses. Its efficacy and low incidence of side effects lead to its unnecessary prescribing in patients with mild pain. Tramadol was classified as a "controlled drug" long after its approval for use in Jordan. Analysis of drugs of abuse in hair has been used in routine forensic toxicology as an alternative to blood in studying addiction history of drug abusers. A method for the determination of tramadol in hair using solid phase extraction and gas chromatography-mass spectrometry (GC-MS) is presented, the method offers excellent precision (3.5-9.8%, (M)=6.77%), accuracy (6.9-12%, M=9.4%) and limit of detection 0.5 ng/mg. The recovery was in the range of 87-94.3% with an average of 90.75%. The calibration curve was linear over the concentration range 0.5-5.0 ng/mg hair with correlation coefficient of 0.998. The developed method was tested on 11 hair samples taken from patients using tramadol as prescribed by their physician along with other different drugs in treating chronic illnesses. Tramadol was detected in all hair samples at a concentration of 0.176-16.3 ng/mg with mean concentration of 4.41 ng/mg. The developed method has the potential of being applied in forensic drug hair testing. In Jordan, hair drug testing started to draw the attention of legal authorities which stimulated forensic toxicologists in recent years to develop methods of analysis of drugs known or have the potential to be abused.  相似文献   

7.
Six groups of common drugs of abuse (cannabinoids, benzoylecgonine, opiates, barbiturates, benzodiazepines and amphetamines) were determined in whole blood after acetone precipitation, using enzyme multiplied immunoassay (EMIT dau) and fluorescence polarisation immunoassay (FPIA--Abbott TDx and ADx) methods. Both methods, designed primarily for urine, allowed the determination of all above mentioned class of drugs but amphetamine. Only 1 ml of a pre- or postmortem blood sample was needed. The sensitivity of cannabinoids determination was higher by FPIA. The FPIA method gave more precise results, particularly in the case of autopsy blood. The method was applied for drug screening in autopsy and police blood samples. The results (both positive and negative) were in agreement with those obtained with chromatographic methods.  相似文献   

8.
生物检材中吗啡类生物碱的LC-MS/MS分析   总被引:7,自引:0,他引:7  
Xiang P  Shen M  Shen BH  Ma D  Bu J  Jiang Y  Zhuo XY 《法医学杂志》2006,22(1):52-54,57
目的针对滥用药物分析鉴定实践中亟待解决的问题,开展LC-MS/MS分析生物检材中吗啡类生物碱的应用研究。方法满足不同的鉴定需要,分别建立血液、尿液、唾液和头发等生物检材的样品前处理方法,确定同时分析海洛因、单乙酰吗啡、吗啡、可待因、乙酰可待因、二氢可待因酮和氢吗啡酮等吗啡类生物碱的LC-MS/MS方法。将方法应用于实际案例。结果所建立的方法对吗啡类生物碱分离良好。尿液稀释法、尿液提取法和头发中吗啡的最低检测限(LOD)分别为10ng/mL、0.01ng/mL和0.01ng/mg。结论所建立的方法简便、快速、特异性强、灵敏度高。目标物中加入二氢可待因酮和氢吗啡酮扩大了方法的实用范围。  相似文献   

9.
Codeine, ethylmorphine and morphine are the most commonly detected opiates in forensic blood samples in Norway. A method for the simultaneous quantification of these opiates utilizing solid phase extraction and gas chromatography-mass spectrometry has been evaluated. The detection limits were 0.026 mumol/l for codeine, 0.025 mumol/l for ethylmorphine and 0.032 mumol/l for morphine (corresponding to 7.8, 7.8 and 9.1 micrograms/l, respectively). The analytical variations at concentrations of 1.0 mumol/l codeine, 1.0 mumol/l ethylmorphine and 0.5 mumol/l morphine were less than 5%.  相似文献   

10.
11.
Methadone maintenance therapy is designed to reduce the need for addicts to use heroin or other illegal opiates. Death in patients starting on such a program has not previously been documented. We report the death of 10 persons who died within days of starting a methadone maintenance program administered by general practitioners. Their bodies were subject to a full autopsy by forensic pathologists, with a full toxicological examination. The mean starting dose had been 53 mg, which had been increased to a mean of 57 mg by the final dose. Death occurred after a mean of 3 days. The mean blood methadone concentration at death was 2.1 mumol/L. Complete toxicological analysis showed that six subjects had additional drugs present including two with alcohol, two with benzodiazepines and morphine, and one with benzodiazepines alone. Pathological examination revealed the presence of chronic persistent hepatitis in all subjects and bronchopneumonia in five. The causes of death were given as methadone toxicity or methadone toxicity in combination with bronchopneumonia. Our observations highlight the dangers of methadone in the first days of starting on a maintenance program, particularly when the starting doses are relatively high and subjects have no demonstrated tolerance to opiates.  相似文献   

12.
Conditions of isolation of opiates from tissues and analysis of the resultant extracts by immunochemical methods are discussed. The main characteristics of OPIATES U kits (Pharmatech) for polarization fluorescent immunoanalysis of cadaveric material (liver) are determined. Immunochemical methods for forensic chemical analysis for opiates are experimentally compared.  相似文献   

13.
A commercially available enzyme-linked immunosorbant assay (ELISA) was evaluated as a screening procedure for the detection of nine classes of abused drugs in postmortem blood and tissue specimens. Specifically, postmortem blood, fluid and/or tissue homogenates were screened for amphetamine (AMP), methamphetamine (MET), barbiturates (BARB), benzodiazepines (BZD), cannabinoids (CNB), cocaine (benzoylecgonine; BE), morphine-specific (MOR), opiates (class; OPI), phencyclidine (PCP) and lysergic acid diethylamide (LSD) by ELISA and by coated tube radioimmunoassay (CTR) (BARB, BE, OPI, PCP, LSD) or double-antibody radioimmunoassay (DAR) (AMP/METH, BZD, CNB). Specimens that screened 'positive' by any method were confirmed and quantitated by gas chromatography/mass spectrometry (GC/MS). The only assay that appeared to perform less optimally than RIA was the MOR assay (five false negatives). However, this assay is very specific for free morphine while the GC/MS confirmation method provided a total morphine value. The OPI assay was more sensitive, producing fewer false negatives, and is recommended for broad class opiate screening. EIA is an adequate alternative to RIA for screening postmortem specimens, including blood and tissue, for nine major classes of drugs.  相似文献   

14.
Due to sensitive limits of detection of chromatographic methods and low limit values regarding the screening of drugs under the terms of impairment in safe driving (§ 24a StVG, Street Traffic Law in Germany), preliminary immunoassay (IA) tests should be able to detect also low concentrations of legal and illegal drugs in serum in forensic cases. False-negatives should be avoided, the rate of false-positive samples should be low due to cost and time. An optimization of IA cutoff values and a validation of the assay is required for each laboratory. In a retrospective study results for serum samples containing amphetamine, methylenedioxy derivatives, cannabinoids, benzodiazepines, cocaine (metabolites), methadone and opiates obtained with CEDIA drugs of abuse reagents on a Hitachi 912 autoanalyzer were compared with quantitative results of chromatographic methods (gas or liquid chromatography coupled with mass spectrometry (GC/MS or LC/MS)). Firstly sensitivity, specificity, positive and negative predictive values and overall misclassification rates were evaluated by contingency tables and compared to ROC-analyses and Youden-Indices. Secondly ideal cutoffs were statistically calculated on the basis of sensitivity and specificity as decisive statistical criteria with focus on a high sensitivity (low rates of false-negatives), i.e. using the Youden-Index. Immunoassay (IA) and confirmatory results were available for 3014 blood samples. Sensitivity was 90% or more for nearly all analytes: amphetamines (IA cutoff 9.5 ng/ml), methylenedioxy derivatives (IA cutoff 5.5 ng/ml), cannabinoids (IA cutoff 14.5 ng/ml), benzodiazepines (IA cutoff >0 ng/ml). Test of opiates showed a sensitivity of 86% for a IA cutoff value of >0 ng/ml. Values for specificity ranged between 33% (methadone, IA cutoff 10 ng/ml) and 90% (cocaine, IA cutoff 20 ng/ml). Lower cutoff values as recommended by ROC analyses were chosen for most tests to decrease the rate of false-negatives. Analyses enabled the definition of cutoff values with good values for sensitivity. Small rates of false-positives can be accepted in forensic cases.  相似文献   

15.
We have described a highly sensitive, accurate, and selective method for the determination of delta 9-THC in postmortem blood. Although the method requires the use of fairly complex and sophisticated equipment, the procedure is straightforward and has been reproduced many times in our laboratories. It is thought that this procedure will serve as a useful adjunct to the forensic scientist in his armamentarium for determining physiological levels of important, abused drugs in postmortem analysis.  相似文献   

16.
The Bavarian State Bureau of Investigation in Munich has the exclusive responsibility for investigation of criminal acts. One considerable expertise is that of hair analysis. According to the legal system in Germany, there is a special interest when some clients' hair tested positive for illicit drugs. An accused with a lot of drugs in his hair will be treated as a supposed addict and will be guaranteed extenuating circumstances. The instrumentation used for hair analysis is a powerful analytical tool: a Varian 3400 gas chromatograph linked to a Finnigan Tandem-MS (TSQ 700). The methanol extraction method is used for the detection of illegal drugs and metabolites: amphetamine, methamphetamine, MDA, MDMA (ecstasy), MDE, MBDB, methadone, THC, EDDP (metabolite of methadone), cocaine, benzoylecgonine, cocaethylene, opiates (dihydrocodeine, codeine, heroin, 6-monoacetylmorphine, morphine, acetylcodeine). For the detection of 9-carboxy-THC by negative chemical ionization the hair sample is hydrolyzed under alkaline conditions. Solid-phase extraction is used for clean-up. The LOQ for the determination of 11-nor-delta-9-tetrahydrocannabinol-9-carboxylic-acid is 0.16 pg/mg hair. An unsurpassed combination for rendering an expert opinion based on hair analysis may be: a forensic expert using diligence and experience, coupled with the performance of a sophisticated analytical instrument.  相似文献   

17.
A GC/MS-method is described for the screening, detection and determination of the commonly used drugs amphetamine, methamphetamine, MDA, MDMA and MBDB in small blood samples and bloodstains using solid phase SPE columns and a pipetting robot (Gilson Aspec XL). The detection limits are in the order of 0.03 to 0.08 microgram/L and the correlation factors between 0.9982 and 0.9998. Furthermore the stability was investigated covering a storage time of 64 days. The method has proven useful in forensic cases with only small sample volumes or bloodstains.  相似文献   

18.
Li PW  Wang YJ  Liu JF 《法医学杂志》2007,23(4):309-311,315
唾液是一种成分简单、易于采集的体液,某些药物在唾液中的浓度可以反映其血药浓度。本文分析了滥用药物进入唾液的机制和影响因素,综述了唾液中滥用药物分析时样品的采集、前处理和检测方法以及唾液与血液中药物浓度的相关性。认为唾液是临床和法医学方面很有价值的分析样品,用唾液中滥用药物浓度来推测血药浓度具有一定的法医学意义。  相似文献   

19.
Benzodiazepines are one of the most widely prescribed drugs for the treatment of a wide spectrum of clinical disorders. They are used as anticonvulsants, anxiolytics, hypnotics or muscle relaxants with different duration of action. In this paper, a simple and sensitive method for the determination of benzodiazepines in whole blood using solid-phase extraction and gas chromatography/mass spectrometry (GC/MS) is described. The drugs spiked in whole blood were extracted with an Oasis HLB solid-phase extraction cartridge (Waters), which contains a copolymer designed to have a hydrophilic-lipophilic balance. GC/MS analysis was performed using a Shimadzu QP-5000 equipped with a BPX5 capillary column (15 mx0.32 mm I.D., film thickness 0.25 microm, SGE). Nineteen benzodiazepines and two thienodiazepines were well separated from each other on their SIM chromatograms and also on the TIC with the exception of oxazolam to cloxazolam separation. The blank extract from whole blood gave no peaks that interfered with all benzodiazepines and thienodiazepines on the chromatogram. The calibration curves for selected benzodiazepines with fludiazepam as an internal standard showed excellent linearity over the concentration range 5-500 ng/ml blood with a correlation coefficients of >0.995. The detection limits ranged from 0.2 to 20 ng/ml blood. The method is simple and sensitive for the determination of benzodiazepines in whole blood and seems to be useful in the practice of forensic science.  相似文献   

20.
The objective of this study was to investigate the accuracy of screening postmortem whole blood for oxycodone using the ratio of the oxycodone immunoassay response to the response for the specimen obtained with a general opiate-class immunoassay. Fifty eight specimens which were negative for opiates and 158 postmortem whole blood specimens positive for opiates including 66 specimens known to contain oxycodone were assayed. Specimens were diluted 1:5 with assay buffer and analyzed by both the Neogen Oxymorphone/Oxycodone ELISA and the Neogen Opiate Group ELISA (Neogen Corporation, Lexington KY). The oxycodone equivalents in ng/mL from the Oxymorphone/Oxycodone ELISA were divided by the morphine equivalents in ng/mL from the Opiates ELISA to obtain an Oxycodone/Opiates Response Ratio. This ratio was compared with the GC/MS data for all specimens and for opiate positive specimens. Receiver Operating Characteristic (ROC) analysis suggested that optimum relative response ratio was 2.0. The sensitivity of the ELISA response ratio for the presence of oxycodone at a response ratio cutoff of 2.0 was 89.4% +/- 3.8% and the specificity was 88.1% +/- 3.2%. Specimens with a ratio of 2.0 or higher had a greater than 50% probability (positive predictive value) of containing oxycodone in a population with a greater than 15% prevalence of oxycodone.  相似文献   