首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 156 毫秒
1.
As literature is poor in functional synthetic cranial models, in this study, synthetic handmade models of cranial vaults were produced in two different materials (a urethane resin and a self‐hardening foam), from multiple bone specimens (eight original cranial vaults: four human and four swine), in order to test their resemblance to bone structure in behavior, during fracture formation. All the vaults were mechanically tested with a 2‐kg impact weight and filmed with a high‐speed camera. Fracture patterns were homogeneous in all swine vaults and heterogeneous in human vaults, with resin fractures more similar to bone fractures. Mean fracture latency time extrapolated by videos were of 0.75 msec (bone), 1.5 msec (resin), 5.12 msec (foam) for human vaults and of 0.625 msec (bone), 1.87 msec (resin), 3.75 msec (foam) for swine vaults. These data showed that resin models are more similar to bone than foam reproductions, but that synthetic material may behave quite differently from bone as concerns fracture latency times.  相似文献   

2.
3.
Sex differences in linear and area dimensions of the foramen ovale and external opening of the carotid canal were analyzed in a documented French sample (35 men and 32 women). The results demonstrated that a low level of sexual dimorphism is present in the cranial base foramina of this sample, with only two-thirds of the examined variables exhibiting statistically significant differences (p < 0.05) between the sexes. The cross-validated sex classification accuracy rates obtained for univariate and multivariate discriminant functions ranged from only 54.7 to 72.1%. In addition, measurements of the cranial base foramina were found to be difficult to record with precision, with intra-observer error percentages ranging from 2.35 to 4.23%. Error rates of this magnitude may result in the misallocation of specimens. Therefore, osteometric analysis of the foramen ovale and carotid canal external opening cannot be recommended as a useful method for cranial sex assessment in this population group.  相似文献   

4.
Contemporary, population‐specific ossification timings of the cranium are lacking in current literature due to challenges in obtaining large repositories of documented subadult material, forcing Australian practitioners to rely on North American, arguably antiquated reference standards for age estimation. This study assessed the temporal pattern of ossification of the cranium and provides recalibrated probabilistic information for age estimation of modern Australian children. Fusion status of the occipital and frontal bones, atlas, and axis was scored using a modified two‐ to four‐tier system from cranial/cervical DICOM datasets of 585 children aged birth to 10 years. Transition analysis was applied to elucidate maximum‐likelihood estimates between consecutive fusion stages, in conjunction with Bayesian statistics to calculate credible intervals for age estimation. Results demonstrate significant sex differences in skeletal maturation (p < 0.05) and earlier timings in comparison with major literary sources, underscoring the requisite of updated standards for age estimation of modern individuals.  相似文献   

5.
The interpretation of cranial base injuries has never been investigated from a purely anthropological perspective. Very little exists in forensic literature in order to interpret the significance of cranial base fractures. We analyzed 296 cases of deaths due to skull–brain injuries. The frequency of vault fractures was 75.7% and that of base fractures was 91.9%. We observed the distribution of cases of death according to manner of death and manner of injury and number of fossae involved. These observations were analytically compared to different variables (age, sex, manner of injury, and mode of injury). The study presented the proportion of base fractures associated with vault fractures, and the frequency of absence of base fracture in subjects with no vault fractures. Interesting associations of base fractures to age and manner of death are shown.  相似文献   

6.
In forensic anthropology, sexually dimorphic cranial features are traditionally visually assessed and scored using an ordinal scale, which is highly subjective. This study quantifies six cranial features using original three‐dimensional coordinate measurements to provide greater accuracy in sex estimation. Cranial features include supraorbital ridges, glabella, external occipital protuberance, nuchal protuberances, mastoid processes, and frontal bosses. Measurements were taken using coordinate calipers from 158 White and Black male and female crania from the Maxwell Documented Collection at University of New Mexico and Tennessee's Bass Collection. Overall, 72.2% of the crania were correctly classified. Males were correctly classified 69.9% of the time, while females were correctly classified 74.7% of the time. The overall value is similar to the results from traditional methods and suggests this method may be just as reliable as established visual sex estimation techniques.  相似文献   

7.
西南地区成人面颅骨的性别判定   总被引:1,自引:1,他引:0  
目的建立适合西南地区成人的颅骨性别判定函数。方法性别明确的颅骨67个,测量颅骨最大长、颅骨最大宽、颅高等16项指标,所得数据进行统计学分析,建立单一变量及多变量性别判定方程,并对5个无名颅骨进行回带检验。结果 16项指标中有13项存在显著的性别差异,男性大于女性,单变量函数推断性别以鼻高(男78.4%,女83.3%)、颅骨最大长(男83.8%,女73.3%)准确率较高。多变量性别判定函数以颅周长、鼻高贡献最大,判定准确率男89.2%,女90.0%。结论单变量推断颅骨性别以鼻高或颅骨最大长较为理想,但以颅周长、鼻高联合推断性别准确率更高。  相似文献   

8.
Abstract:  To help improve sex assessment from skeletal remains, the present study considers the diagnostic value of the sacral base (basis osseus sacri) based on its planar image and related metric data. For this purpose, 114 adult sacra of known sex and age from two early 20th century Italian populations were examined, the first from Bologna, northern Italy ( n  = 76), and the second from Sassari, Sardinia ( n  = 38). Digital photos of the sacral base were taken with each bone in a standardized orientation. Technical drawing software was used to trace its profile and to measure related dimensions (area, perimeter, and breadth of S1 and total breadth of the sacrum). The measurements were subjected to discriminant and classification function analyses. The sex prediction success of 93.2% for the Bolognese sample, 81.6% for the Sassarese sample, and 88.3% for the pooled sample indicates that the first sacral vertebra is a good character for sex determination.  相似文献   

9.
10.
Sexual dimorphism is a crucial characteristic of skeleton. In the last years, volumetric and surface 3D acquisition systems have enabled anthropologists to assess surfaces and volumes, whose potential still needs to be verified. This article aimed at assessing volume and linear parameters of the first metatarsal bone through 3D acquisition by laser scanning. Sixty‐eight skeletons underwent 3D scan through laser scanner: Seven linear measurements and volume from each bone were assessed. A cutoff value of 13,370 mm3 was found, with an accuracy of 80.8%. Linear measurements outperformed volume: metatarsal length and mediolateral width of base showed higher cross‐validated accuracies (respectively, 82.1% and 79.1%, raising at 83.6% when both of them were included). Further studies are needed to verify the real advantage for sex assessment provided by volume measurements.  相似文献   

11.
Few studies have assessed the use of the frontal sinus cavities for sex differentiation. In this study, a new methodology was used to assess the reliability of CBCT images of the frontal sinus cavity for determining sex based on the sexual dimorphism found in this anatomical structure. The survey sample consisted of 130 scans that were reconstructed three‐dimensionally. 3D images of the cavity volume in the frontal, lateral, and basal views were exported in TIFF. The following variables were measured in a second program: area, perimeter, bounding rectangle, ellipse fit, circularity, aspect ratio, roundness, solidity, and Feret's diameter. The methodology demonstrated the existence of sexual dimorphism with an accuracy of 80.0% in the logistic regression model. The basal view had the greatest explanatory power in the final model. This methodology may be used as an alternative way of determining a reliable biological profile during the analysis of skeletal remains.  相似文献   

12.
Determination of sex constitutes the most important element during the identification process of human skeletal remains. Several sex‐specific features of human skeleton have been exploited for sex determination with varying reliability. This study aims to obtain sexual dimorphic standards for ulnae of the north Indian population. Eight measurements were obtained on a sample of 106 ulnae (males‐80, females‐26) in the age range of 25–65 years. The sexual dimorphism index and demarking points were calculated for all the variables. The data were then subjected to stepwise and direct discriminant function analysis. The best discriminator of sex was the maximum length (84.9%) followed by radial notch width (84%). In stepwise analysis, these two variables were selected and provided an accuracy of 88.7% (M‐87.5%, F‐92.3%). The proximal end provided a classification rate of 81.1% (M‐80%, F‐84.6%) with selection of the notch length and olecranon width.  相似文献   

13.
Abstract: Cremains have become increasingly frequent in forensic contexts, while higher body mass in the general population has simultaneously made cremation a more cost‐effective mortuary practice. This study analyzed the relationship between body mass and bone mass, as reflected through cremation weight. Antemortem data were recorded for samples used in the multi‐regional data set. Each was rendered through commercial crematoriums and reweighed postincineration. Pearson’s correlation demonstrates clear association between body mass and cremation weight (r = 0.56; p < 0.0001). However, multiple linear regression revealed sex and age variables also have a significant relationship (t = 7.198; t = ?2.5, respectively). Regressed in conjunction, body mass, sex, and age contribute approximately 67% of all variation observed in cremation weight (r = 0.668). Analysis of covariance indicates significant regional variation in body and cremation weight. Explanations include bone modification resulting from increased loading stress, as well as glucose intolerance and altered metabolic pathways related to obesity.  相似文献   

14.
Sex estimation in human skeletal remains when using the cranium through traditional methods is a fundamental pillar in human identification; however, it may be possible to incur in a margin of error due because of the state of preservation in incomplete or fragmented remains. The aim of this investigation was sex estimation through the geometric morphometric analysis of the frontal bone. The sample employed 60 lateral radiographs of adult subjects of both sexes (30 males and 30 females), aged between 18 and 40 years, with mean age for males of 28 ± 4 and 30 ± 6 years for females. Thin‐plate splines evidenced strong expansion of the glabellar region in males and contraction in females. No significant differences were found between sexes with respect to size. The findings suggest differences in shape and size in the glabellar region, besides reaffirming the use of geometric morphometrics as a quantitative method in sex estimation.  相似文献   

15.
This study uses five well‐documented cranial nonmetric traits (glabella, mastoid process, mental eminence, supraorbital margin, and nuchal crest) and one additional trait (zygomatic extension) to develop a validated decision tree for sex assessment. The decision tree was built and cross‐validated on a sample of 293 U.S. White individuals from the William M. Bass Donated Skeletal Collection. Ordinal scores from the six traits were analyzed using the partition modeling option in JMP Pro 12. A holdout sample of 50 skulls was used to test the model. The most accurate decision tree includes three variables: glabella, zygomatic extension, and mastoid process. This decision tree yielded 93.5% accuracy on the training sample, 94% on the cross‐validated sample, and 96% on a holdout validation sample. Linear weighted kappa statistics indicate acceptable agreement among observers for these variables. Mental eminence should be avoided, and definitions and figures should be referenced carefully to score nonmetric traits.  相似文献   

16.
This paper examines the pattern and magnitude of craniofacial change in American blacks and whites over the past 125 years. Standard metric data from 885 crania were used to document the changes from 1850 to 1975. Data from 19th century crania were primarily from anatomical collections, and 20th century data were available from the forensic anthropology data bank. Canonical correlation was used to obtain a linear function of cranial variables that correlates maximally with year of birth. Canonical correlations of year of birth with the linear function of cranial measurements ranged from 0.55 to 0.71, demonstrating that cranial morphology is strongly dependent on year of birth. During the 125 years under consideration, cranial vaults have become markedly higher, somewhat narrower, with narrower faces. The changes in cranial morphology are probably in large part due to changes in growth at the cranial base due to improved environmental conditions. The changes are likely a combination of phenotypic plasticity and genetic changes over this period.  相似文献   

17.
Estimating stature in human skeletal remains of Asian ancestry is problematic for forensic anthropologists due to the paucity and uncertain suitability of regression formulae. To address this issue, our study analyzed 64 individuals from a modern skeletal collection of South‐East Asian origin and developed population‐specific ordinary least squares regression formulae to estimate skeletal height from each of the long bones of the upper and lower limbs, as well as from trunk length. Results indicate that the most accurate estimates of skeletal height from a single bone (as measured by standard error of the estimate—SEE) are from tibial length in males (SEE = 2.40 cm) and from humeral length in females (SEE = 2.59 cm), followed by femoral length (SEE = 2.84 cm). When multiple elements are considered, the combination of femoral and tibial length yields the best estimates in both sexes as well as combined sex samples (male SEE = 2.40 cm; female SEE = 2.77 cm; combined sex SEE = 2.54 cm).  相似文献   

18.
目的建立利用舌骨形态测量值判别性别的方法,并探讨其在法医学应用中的价值。方法对于河北地区收集的108例舌骨样本(男78例,女30例)进行观察研究,确立11个观测指标并进行测量,测量值采用SPSS统计软件进行统计学分析,建立利用舌骨形态测量值判别性别的方程,并进行Fisher判别分析。结果在11项观察指标中,8项测量指标男女性别间存在显著性统计学差异(P<0.01);利用8项测量指标中的任一指标或之中的多个指标组合建立线性性别判别方程,方程判别性别的准确率在66%~92%,其中多指标的方程判别性别准确率较单一指标的方程高,最高达到92%。结论舌骨形态存在着性别差异,利用多个舌骨形态学测量值建立的性别判别方程准确率较高,可用于无名尸骨的性别判别。  相似文献   

19.
The hip bone is considered to be one of the most reliable indicators in sex determination. The aim of this study was to test the reliability of the DSP method for the hip bone proposed by Murail et al. (Bull Mem Soc Anthropol Paris, 17, 2005, 167) on a sample from a present‐day population in France (52 males and 54 females). Ten linear measurements were collected from three‐dimensional models derived from computed tomography images (CTI). To quantify the proportions of correct sex determinations, a more rigorous posterior probability threshold of 0.95 was applied. Using all 10 measurements, 92.3% of males and 97.2% of females were sexed correctly. The percentage of undetermined specimens varied depending on the used combination of measurements; however, all sexes were assigned with a 100% accuracy. This study proves that DSP is an appropriate and reliable tool for sex determination, based on dimensions obtained from CTI.  相似文献   

20.
Abstract: Three‐dimensional (3D) laser scanner models of human crania can be used for forensic facial reconstruction, and for obtaining craniometric data useful for estimating age, sex, and population affinity of unidentified human remains. However, the use of computer‐generated measurements in a casework setting requires the measurement precision to be known. Here, we assess the repeatability and precision of cranial volume and surface area measurements using 3D laser scanner models created by different operators using different protocols for collecting and processing data. We report intraobserver measurement errors of 0.2% and interobserver errors of 2% of the total area and volume values, suggesting that observer‐related errors do not pose major obstacles for sharing, combining, or comparing such measurements. Nevertheless, as no standardized procedure exists for area or volume measurements from 3D models, it is imperative to report the scanning and postscanning protocols employed when such measurements are conducted in a forensic setting.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号