首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 453 毫秒
1.
Gamma-hydroxybutyric acid (GHB) can cause problems in interpretation of toxicological findings due to its endogenous nature, significant production in tissues after death and potential formation in stored samples. Our study was designed to determine the influence of storage conditions on GHB levels and its possible in vitro formation in blood and urine in cases where no exogenous use of GHB or its precursors was suspected. The samples were prepared by validated method based on liquid-liquid reextraction with adipic acid internal standard and MSTFA derivatization and assayed on a GC-MS operating in EI SIM mode. The first part of the study was performed with pooled blood and urine samples obtained from living and deceased subjects stored with and without NaF (1% w/v) at 4 and -20 degrees C over 8 months. In ante-mortem samples (both blood and urine) no significant GHB production was found. After 4 months of storage, the substantial GHB rise up to 100 mg/Lwas observed in post-mortem blood stored at 4 degrees C without NaF with subsequent gradual decrease in following months. The inhibition of GHB production was apparent during storage in NaF treated frozen blood samples. In post-mortem urine only slight temporary GHB levels were ascertained (up to 8 mg/L). The second part of our study was aimed to analyse 20 individual post-mortem blood samples stored at 4 degrees C for 16-27 days between autopsy and analysis without preservation followed by storage at 4 degrees C with NaF for 4 months. The temporary GHB production with maximum of 28 mg/Lwas detected in some samples.  相似文献   

2.
This study was designed to supplement previous studies that documented in vitro production of gamma-hydroxybutyrate (GHB) in urine samples. Urine samples were provided by subjects who reported that they had never used GHB (n=31). The specimens were stored under standard conditions of refrigeration (5 degrees C) without any preservatives added. All specimens were repeatedly analyzed for the presence of endogenous GHB over a 6-month period using a previously reported headspace GC-MS method. Significant elevations in GHB were observed in many of the urine samples as storage time increased. As a result, the in vitro production of GHB may increase the apparent GHB concentrations in urine during storage. This potential for an artificial increase in GHB concentration must be appreciated when establishing the threshold between endogenous and exogenous concentrations of GHB.  相似文献   

3.
The in vitro production of GHB was observed in freshly collected, untreated whole blood samples using glass BD-Vacutainers and polypropylene S-monovettes. GHB concentrations were determined daily over a period of one week and after 3, 6 and 9 weeks again. Furthermore, the GHB concentration in 40 untreated random whole blood samples stored at 4°C for a longer period of time (10 samples 12 month, 10 samples 24 month and 20 samples 36 month) was also determined. For comparison, the in vitro production of GHB in freshly collected and prepared serum samples was observed. GHB serum concentrations were determined three times over a period of one week and once again after six weeks. Sample preparation was performed by means of methanolic extraction following the precipitation of whole blood and serum samples. A methanolic standard calibration was done in a low range of 0.005-0.1 μg/mL (LOD: 0.004, LLOQ: 0.013). For quantification a spiked blood bank serum with a determined GHB concentration of 0.09 μg/mL was used. Corrected calibrations in the range of 0.09-5.09 μg/mL were used (LOD: 0.08 μg/mL, LLOQ: 0.30 μg/mL), recovery: 91.3% (high level: 4.09 μg/mL) 50.5% (low level: 0.19 μg/mL). RESULTS: Relevant elevation of GHB was observed in all whole blood samples stored in liquid form (4°C or room temperature). In two of the 40 whole blood samples stored over a longer period of time at 4°C, GHB concentrations in the range of 13 μg/mL were even determined. These findings constitute grounds for caution. Even a GHB cut-off level of 5 μg/mL cannot be considered as "absolutely positive" proof of a case of exogenous administration, at least in untreated liquid blood samples in long time storage. However, no significant elevations of GHB were otherwise observed in any of the serum samples independently of storage temperature nor in the whole blood samples that were frozen for storage. CONCLUSIONS: The results suggest that the cut-off for exogenous GHB of 5 μg/mL could be lowered significantly, with the consequence of winning valuable time for the potential victim, but only if serum is collected for GHB determination or if the whole blood sample is frozen immediately after collection and the procedure well documented.  相似文献   

4.
This study compared endogenous gamma-hydroxybutyric acid (GHB) concentrations in various postmortem fluid samples of 25 autopsy cases. All bodies were stored between 10-20 degrees C until autopsy, and the intervals between death and autopsy were less than 2 days (6-48 h). GHB concentrations were measured by headspace gas chromatography after GHB was converted to gamma-butyrolactone. Endogenous GHB concentrations were significantly higher in femoral venous blood (4.6+/-3.4 microg/ml, n=23) than in cerebrospinal fluid (1.8+/-1.5 microg/ml, n=9), vitreous humor (0.9+/-1.7 microg/ml, n=8), bile (1.0+/-1.1 microg/ml, n=9) and urine (0.6+/-1.2 microg/ml, n=12). GHB concentrations were similar in blood samples taken from different sites. Cut-off limits of 30 and 10 microg/ml are proposed for blood and urine, respectively, to discriminate between exogenous and endogenous GHB in decedents showing no or little putrefaction (postmortem intervals usually 48 h or less). The criterion established for endogenous GHB in postmortem urine may also be applicable to analytical results in cerebrospinal fluid, vitreous humor and bile from deceased persons.  相似文献   

5.
尿液、血液中γ-羟丁酸的气质联用法分析   总被引:3,自引:0,他引:3  
目的为尿液、血液中γ-羟丁酸(gamma-hydroxybutyricacid,GHB),γ-羟丁酸内酯(gamma-butyrolactone,GBL)和1,4-丁二醇(1,4-butanediol,1,4-BD)的鉴定提供方法和依据。方法100μl尿液或血液以GHBd6为内标,经乙酸乙酯提取、BSTFA衍生化后,用GC/MS法分析。结果测尿液中内源性GHB的线性范围是20-800ng/ml,R2=0.9995,最低检出限为10ng/ml(S/N≥3);测尿液、血液中外源性GHB的线性范围为5-60μg/ml,R2分别为0.9999和0.9928。相对回收率为99%-104%。以所建方法测定了健康志愿者尿液中内源性GHB含量,并考察了健康受试者外源性GHB的代谢情况。结论所建方法准确、便捷、省时、选择性好,适用于法医毒物学鉴定。  相似文献   

6.
The endogenous nature of the drug of abuse gamma hydroxybutyric acid (GHB) has caused various interpretative problems for toxicologists. In order to obtain data for the presence of endogenous GHB in humans and to investigate any factors that may affect this, a volunteer study was undertaken. The GHB concentrations in 119 urine specimens from GHB-free subjects and 25 urine specimens submitted for toxicological analysis showed maximal urinary GHB concentrations of 3mg/l. Analysis of 15 plasma specimens submitted for toxicological analysis detected no measurable GHB (less than 2.5mg/l). Studies in a male and female volunteer in which different dietary food groups were ingested at weekly intervals, showed significant creatinine-independent intra-individual fluctuation with overall urine GHB concentrations between 0 and 2.55, and 0 and 2.74mg/l, respectively. Urinary concentrations did not appear to be affected by the particular dietary groups studied.The concentrations measured by gas chromatography with flame ionisation detection (GC-FID) and gas chromatography with mass spectrometry (GC-MS) lend further support to the proposed urinary and plasma interpretative cut-offs of 10 and 4mg/l, respectively, where below this it is not possible to determine whether any GHB detected is endogenous or exogenous in nature.  相似文献   

7.
In recent years, the post-mortem production of the drug of abuse gamma-hydroxybutyric acid (GHB) in biological fluids (e.g. blood and urine) has caused various interpretative problems for toxicologists. Previously, other researchers have shown certain microbial species (Pseudomonas spp. and Clostridium aminobutyricum) possess the necessary enzymes to convert GABA to GHB. A preliminary investigation involving putrefied post-mortem blood indicated there was no observed relationship between "endogenous" GHB concentrations and concentrations of common putrefactive markers (tryptamine and phenyl-2-ethylamine). Microbiological analysis identified the presence of various micro-organisms: Clostridia spp., Escherichia coli, Proteus vulgaris, Enterococcus faecalis and Aeromonoas spp. Equine plasma, human blood and urine samples were inoculated with these and an additional micro-organism (Pseudomonas aeruginosa) and incubated at 22 degrees C for 1 month. Following comparison with control samples and pre-inoculation concentrations, the data indicated an apparent production of GHB in unpreserved P. aeruginosa inoculated blood (2.3 mg/l). All other fluoride-preserved and unpreserved samples (including controls) had GHB concentrations <1mg/l. Although this concentration is lower than is typically associated with "endogenous" post-mortem GHB concentrations, this paper proposes a potential microbial production of GHB with time.  相似文献   

8.
Urine is often the sample of choice for drug screening in aviation/general forensic toxicology and in workplace drug testing. In some instances, the origin of the submitted samples may be challenged because of the medicolegal and socioeconomic consequences of a positive drug test. Methods for individualization of biological samples have reached a new boundary with the application of the polymerase chain reaction (PCR) in DNA profiling, but a successful characterization of the urine specimens depends on the quantity and quality of DNA present in the samples. Therefore, the present study investigated the influence of storage conditions, sample volume, concentration modes, extraction procedures, and chemical preservations on the quantity of DNA recovered, as well as the success rate of PCR-based genotyping for DQA1 and PM loci in urine. Urine specimens from male and female volunteers were divided and stored at various temperatures for up to 30 days. The results suggested that sample purification by dialfiltration, using 3000-100,000 molecular weight cut-off filters, did not enhance DNA recovery and typing rate as compared with simple centrifugation procedures. Extraction of urinary DNA by the organic method and by the resin method gave comparable typing results. Larger sample volume yielded a higher amount of DNA, but the typing rates were not affected for sample volumes between 1 and 5 ml. The quantifiable amounts of DNA present were found to be greater in female (14-200 ng/ml) than in male (4-60 ng/ml) samples and decreased with the elapsed time under both room temperature (RT) and frozen storage. Typing of the male samples also demonstrated that RT storage samples produced significantly higher success rates than that of frozen samples, while there was only marginal difference in the DNA typing rates among the conditions tested using female samples. Successful assignment of DQA1 + PM genotype was achieved for all samples of fresh urine, independent of gender, starting sample volume, or concentration method. Preservation by 0.25% sodium azide was acceptable for sample storage at 4 degrees C during a period of 30 days. For longer storage duration, freezing at -70 degrees C may be more appropriate. Thus, the applicability of the DQA1 + PM typing was clearly demonstrated for individualization of urine samples.  相似文献   

9.
Gamma-hydroxybutyric acid's (GHB's) natural presence in the body has made the interpretation of its levels a challenging task for the forensic toxicologist. This study was designed to measure endogenous GHB levels in antemortem urine and blood samples. The range detected in urine was from 34 to 575 microg/dl and in blood from 17 to 151microg/dl. The results indicate that the concentration of endogenous GHB in urine and blood concur with the suggested cut-off levels at 1000 and 500 microg/dl, respectively.  相似文献   

10.
Urinary endogenous concentrations of gamma-hydroxybutyric acid (GHB), alpha-hydroxybutyric acid (AHB) and beta-hydroxybutyric acid (BHB) have been investigated for both healthy humans and diabetics by using a newly optimized GC-MS procedure. The endogenous concentrations in healthy volunteers' urine ranged 0.16-2.14 microg/ml for GHB, 0.10-2.68 microg/ml for AHB and 8.51-34.7 microg/ml for BHB. In diabetics, the concentrations ranged 0.17-3.03 microg/ml for GHB, 0.14-124 microg/ml for AHB and 4.94-4520 microg/ml for BHB. Although notably elevated BHB and AHB concentrations were observed for severely uncontrolled diabetics, their GHB concentrations ranged within or near the range seen in healthy humans. The results of this study confirm the previously suggested 10 microg/ml cutoff concentration of urinary GHB to distinguish exogenous GHB, even for uncontrolled diabetic patients suffering severe ketoacidosis.  相似文献   

11.
GHB can be produced either as a pre- or postmortem artifact. The authors describe two cases in which GHB was detected and discuss the problem of determining the role of GHB in each case. In both cases, NaF-preserved blood and urine were analyzed using gas chromatography. The first decedent, a known methamphetamine abuser, had GHB concentrations similar to those observed with subanesthetic doses (femoral blood, 159 microg/ml; urine, 1100 microg/ml). Myocardial fibrosis, in the pattern associated with stimulant abuse, was also evident. The second decedent had a normal heart but higher concentrations of GHB (femoral blood, 1.4 mg/ml; right heart, 1.1 mg/ml; urine, 6.0 mg/ml). Blood cocaine and MDMA levels were 420 and 730 ng/ml, respectively. Both decedents had been drinking and were in a postabsorptive state, with blood to vitreous ratios of less than 0.90. If NaF is not used as a preservative, GHB is produced as an artifact. Therefore, the mere demonstration of GHB does not prove causality or even necessarily that GHB was ingested. Blood and urine GHB concentrations in case 1 can be produced by a therapeutic dose of 100 mg, and myocardial fibrosis may have had more to do with the cause of death than GHB. The history in case 2 is consistent with the substantial GHB ingestion, but other drugs, including ethanol, were also detected. Ethanol interferes with GHB metabolism, preventing GHB breakdown, raising blood concentrations, and making respiratory arrest more likely. Combined investigational, autopsy, and toxicology data suggest that GHB was the cause of death in case 2 but not case 1. Given the recent discovery that postmortem GHB production occurs even in stored antemortem blood samples (provided they were preserved with citrate) and the earlier observations that de novo GHB production in urine does not occur, it is unwise to draw any inferences about causality unless (1) blood and urine are both analyzed and found to be elevated; (2) blood is collected in NaF-containing tubes; and (3) a detailed case history is obtained.  相似文献   

12.
There is no toxicological analysis of gamma-hydroxybutyrate (GHB) applied routinely in cases of driving under influence (DUI); therefore the extent of consumption of this drug might be underestimated. Its consumption is described as occurring often concurrently with amphetamine or ecstasy. This study examines 196 serum samples which were collected by police during road side testing for GHB. The samples subject to this study have already been found to be positive for amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA) and/or 3,4-methylenedioxyethamphetamine (MDEA). Analysis has been performed by LC/MS/MS in the multiple reaction monitoring (MRM) mode. Due to its polarity, chromatographic separation of GHB was achieved by a HILIC column. To differentiate endogenous and exogenous levels of GHB, a cut-off concentration of 4μg/ml was applied. Of the 196 samples, two have been found to be positive for GHB. Of these samples, one sample was also positive for amphetamine and one for MDMA. Whilst other amphetamine derivates were not detected in these samples, both samples were found to be positive for cannabinoids. These results suggest that co-consumption of GHB with amphetamine or ecstasy is relatively low (1%) for the collective of this study.  相似文献   

13.
We report a case of fatal intoxication from 1,4‐butanediol (1,4‐BD), which was ingested by a young and “naïve” gamma‐hydroxybutyrate (GHB) consumer during a party with the co‐ingestion of alcohol, cannabis, and methylene‐dioxy‐methamphetamine. The following drug concentrations were found using gas chromatography coupled with mass spectrometry on autopsy samples and on a cup and a glass found at the scene: 20,350 mg/L (bottle) for 1,4‐BD; 1020 mg/L (femoral blood), 3380 mg/L (cardiac blood), 47,280 mg/L (gastric content), and 570 mg/L (vitreous humor) for GHB. The concentration of GHB is difficult to interpret in forensic cases due to the possibility of an endogenous production of GHB. The variable tolerance of the user may also modify the peri‐ and postmortem GHB concentrations. This case underscores the need to have many different sources of toxicology samples analyzed to avoid the hypothesis of endogenous production of GHB.  相似文献   

14.
The effect of chilling at the time of death on the postmortem chemistry of the vitreous humor was studied by using sheep heads obtained immediately following decapitation. One group of heads was kept at room temperature, while the remainder were chilled on ice or in ice water, then refrigerated or frozen. Vitreous humor specimens were taken at intervals over a 48-h period. Chilling inhibited the fall in the glucose concentration and the total carbon dioxide content and lessened the increase in lactic acid, compared to the room temperature group. Rapid glycolysis resumed when the heads rewarmed to room temperature starting at 6-h postmortem, but did not resume at later points. The rate of rise of the potassium and magnesium concentrations was also diminished in the chilled eyes. Freezing and thawing caused an abrupt increase in the potassium and magnesium levels, but other solutes were unaffected.  相似文献   

15.
The stability of drugs in biological specimens is a major concern during the evaluation of the toxicological results. The stability of morphine, codeine, and 6‐acetyl‐morphine in blood was studied after different sampling conditions: (i) in glass, polypropylene or polystyrene tubes, (ii) with addition of dipotassium ethylene diamine tetraacetic acid (K2EDTA) or sodium oxalate (Na2C2O4), and (iii) with or without the addition of sodium fluoride (NaF). Spiked blood samples were stored at two different temperatures (4 and ?20°C), analyzed after different storage times and after three freeze–thaw cycles. Opiate concentrations were decreased in all conditions, but the most unstable was 6‐acetyl‐morphine. The addition of NaF as preservative improved the stability of opiates at all conditions studied, whereas the type of anticoagulant did not affect the stability of opiates. It was concluded that blood samples should be stored at ?20°C in glass tubes containing oxalate and NaF for maximum stability.  相似文献   

16.
A controlled study was undertaken to determine the stability of the designer drugs MDA, MDMA and MDEA in pooled serum, whole blood, water and urine samples over a period of 21 weeks. The concentrations of the individual designer drugs in the various matrices were monitored over time, in the dark at various temperatures (-20, 4 or 20 degrees C), for a low (+/- 6 ng/ml for water, serum and whole blood and +/- 150 ng/ml for urine) and a high concentration level (+/- 550 ng/ml for water, serum and whole blood and +/- 2500 ng/ml for urine). Compound concentrations were measured using a validated HPLC assay with fluorescence detection. Our study demonstrated no significant loss of the designer drugs in water and urine at any of the investigated temperatures for 21 weeks. The same results were observed in serum for up to 17 weeks, and up to 5 weeks in whole blood. After that time, the compounds could no longer be analyzed due to matrix degradation, especially in the low concentration samples that were stored at room temperature. This study demonstrates that the designer drugs, MDA, MDMA and MDEA are stable when stored at -20 degrees C for 21 weeks, even in haemolysed whole blood.  相似文献   

17.
A fatal case of 1,4-butanediol (1,4-BD) oral ingestion is reported here, in which a 51-year-old man was found dead in his bed. According to the police report, the deceased was a known drug user. A glass bottle labeled (and later confirmed to be) “Butandiol 1,4” (1,4-BD) was found in the kitchen. Furthermore, the deceased's friend stated that he consumed 1,4-BD on a regular basis. The autopsy and histological examination of postmortem parenchymatous organ specimens did not revealed a clear cause of death. Chemical-toxicological investigations revealed gammahydroxybutyrat (GHB) in body fluids and tissues in the following quantities: femoral blood 390 mg/L, heart blood 420 mg/L, cerebrospinal fluid 420 mg/L, vitreous humor 640 mg/L, urine 1600 mg/L, and head hair 26.7 ng/mg. In addition, 1,4-BD was qualitatively detected in the head hair, urine, stomach contents, and the bottle. No other substances, including alcohol, were detected at pharmacologically relevant concentrations. 1,4-BD is known as precursor substance that is converted in vivo into GHB. In the synoptic assessment of toxicological findings, the police investigations and having excluded other causes of death, a lethal GHB-intoxication following ingestion of 1,4-BD, can be assumed in this case. Fatal intoxications with 1,4-BD have seldom been reported due to a very rapid conversion to GHB and, among other things, non-specific symptoms after ingestion. This case report aims to give an overview to the published of fatal 1,4-BD-intoxications and to discuss the problems associated with detection of 1,4-BD in (postmortem) specimens.  相似文献   

18.
Medical examiners frequently rely on the finding of free morphine present in postmortem specimens to assist in certifying deaths associated with narcotics. In vitro hydrolysis of morphine-3-D glucuronide (M3DG) to free morphine was studied using variable specimen pH, initial degree of specimen putrefaction, storage temperature and time, and the effectiveness of sodium fluoride (NaF) preservation. Reagent M3DG was added to opiate-free fresh blood and urine and to autopsy-derived blood specimens. Reagent bovine glucuronidase was also added to certain specimens. Freshly collected and refrigerated NaF-preserved blood produced minimal free morphine, whereas four of five autopsy blood specimens produced free morphine from M3DG. Increased storage time, temperature, and initial degree of putrefaction resulted in greater free morphine generation despite the absence of viable bacteria. Hydrolysis occurring during specimen storage can generate free morphine from M3DG and may result in erroneous conclusions in certifying narcotic deaths.  相似文献   

19.
Abstract: A new screening method for detecting gamma-hydroxybutyric acid (GHB) in drink matrices, using the IonSense, Inc. (Saugus, MA) direct analysis in real time (DART) ion source coupled to a JEOL exact mass time-of-flight mass spectrometer (AccuTOF), was validated and compared with the current screening methodology. The DART ion source allows for analysis of samples under ambient conditions with little to no sample preparation. Fifty drink specimens were spiked at levels of 1, 2, 3, and 4 mg/mL GHB, and analyzed on the AccuTOF-DART. Positive detection of GHB occurred for each of the samples at each concentration level, giving 100% accuracy for the samples tested. Twenty-five of the 50 drink specimens were spiked at 1 mg/mL GHB and tested using a color test known as the GHB Color Test #3. Only two of these 25 specimens tested positive for the presence of GHB, giving only 8% accuracy. Implementation of this new methodology as a screening tool for GHB analysis will quickly eliminate negative specimens allowing the examiner to focus analysis time on those that screened positive.  相似文献   

20.
Evidentiary urine samples (n = 345) stored frozen at -20 degrees C in their original containers (leakproof 100 mL plastic bottles) upon retesting for ethanol resulted in concentrations that were significantly lower (average loss = approximately 30%) than those prior to their storage at -20 degrees C (p < or = 0.0001). The observed loss of ethanol was independent of the method of thawing or the concentration of ethanol in the samples, but was dependent on the sample volume in the container, i.e., the larger the volume of sample the larger the magnitude of ethanol loss. The loss of ethanol was determined to be due to improper sealing by a Styrofoam integrity seal attached to the mouth of the container. Accordingly, adopting leakproof plastic containers that do not contain Styrofoam integrity seals, but rather an outside and across the cap tape integrity seal for evidence collection and long-term storage, will prevent loss of ethanol due to evaporation.  相似文献   