首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 937 毫秒
1.
Abstract: Tribometers are mechanical devices used to measure walkway coefficient of friction (COF) for the purpose of assessing slip risk. The purpose of this study was to define a tribometer reference standard and use it to assess the performance of various tribometers. Eighty subjects were randomly assigned to walk across one of four wet walkway surfaces (polished black granite, porcelain, vinyl composition tile, and ceramic tile) to establish the relative slipperiness of each surface. Eleven tribometers were subsequently used to measure and rank the COF of all four surfaces. Our results revealed that only four of the 11 tribometers (Wessex pendulum, Sigler pendulum, Mark II, and Mark III) met our compliance criteria by both correctly ranking all four surfaces and differentiating between surfaces of varying degrees of slipperiness. Our protocol demonstrates that human gait‐based measures of slipperiness can be used to create reference standards against which tribometer measurements can be validated.  相似文献   

2.
The purpose of this study was to assess the viability of using slip risk (as quantified during human subject walking trials) to create a reference standard against which tribometer readings could be compared. First, human subjects (N=84) were used to rank objectively the slipperiness of three different surfaces with and without a contaminant (six conditions). Second, nine tribometers were used to independently measure and rank surface slipperiness for all six conditions. The slipperiness ranking determined from the walking trials was considered the reference against which the tribometer measurements were compared. Our results revealed that only two of the nine tribometers tested (Tortus II and Mark III) met our compliance criteria by both correctly ranking all six conditions and differentiating between surfaces of differing degrees of slipperiness. These findings reinforce the need for objective criteria to ascertain which tribometers effectively evaluate floor slipperiness and a pedestrian's risk of slipping.  相似文献   

3.
目的探索新的手印显现方法,祛除传统手印显现方法对使用者的健康危害;方法用浅色调湿粉采用不同操作对不同客体表面手印、不同物质手印及不同遗留时间手印进行显现,通过显现效果的比较,得出湿粉显现手印的适用范围、最佳操作方法及其显现效果;结果显出的手印清晰、流畅,与背景反差强;结论该方法适用于光滑非渗透性客体表面及潮湿或粘性表面的汗潜、油潜、蛋白手印的显现,使用方便有效。  相似文献   

4.
目的探索显现潮湿纸张表面油脂手印的显现方法。方法取250枚纸张载体的油脂指印,分为AB-CDE 5组,分别用自来水浸泡不同时间后,用尼罗红工作液显现,并在465nm多波段光源下进行观察。结果 5组的显现率从56%~94%,表明显出率比较高。结论该方法简单实用,可用于案件检验。  相似文献   

5.
Determining maximum heating temperatures of burnt bones is a long‐standing problem in forensic science and archaeology. In this pilot study, controlled experiments were used to heat 14 fleshed and defleshed pig vertebrae (wet bones) and archaeological human vertebrae (dry bones) to temperatures of 400, 600, 800, and 1000°C. Specular component included (SCI) color values were recorded from the bone surfaces with a Konica‐Minolta cm‐2600d spectrophotometer. These color values were regressed onto heating temperature, using both a traditional linear model and the k‐nearest neighbor (k‐NN) machine‐learning algorithm. Mean absolute errors (MAE) were computed for 1000 rounds of temperature prediction. With the k‐NN approach, the median MAE prediction errors were 41.6°C for the entire sample, and 20.9°C for the subsample of wet bones. These results indicate that spectrophotometric color measurements combined with machine learning methods can be a viable tool for estimating bone heating temperature.  相似文献   

6.
1,2-indanedione is an emerging fingermark reagent used on porous surfaces. The general consensus is that this reagent is at least as sensitive as DFO, with some research showing higher sensitivity for 1,2-indanedione as opposed to DFO. However, a number of discrepancies existed in the literature as to which formulation and which development procedure produces optimal results. This project set out to investigate the best formulation and development procedure under Australian conditions, encompassing all published recommendations as well as some novel approaches. 1,2-indanedione formulations were compared with respect to initial colour, fluorescence, concentration of reagent, acetic acid concentration, and the effect of different carrier solvents. Numerous development conditions were investigated, including a conventional oven, a heat press and humidity. Further enhancement using metal salt treatment and liquid nitrogen was also evaluated. The heat press set at 165 degrees C for 10s proved to give the best initial colour and most intense luminescence. Secondary metal salt treatment improved initial colour and luminescence. The Polilight, the VSC 2000, and the Condor Chemical Imaging macroscope have been used to detect the fingerprints developed with 1,2-indanedione on a variety of high- and low-quality porous and semi-porous surfaces, with impressive results overall. Laboratory and field tests were conducted to compare 1,2-indanedione with DFO and ninhydrin as well as to investigate the position of 1,2-indanedione in the sequence of reagents for fingermark detection on porous surfaces. Overall, 1,2-indanedione proved to be a viable alternative to traditional methods for the detection of fingermarks on porous surfaces, with more fingermarks being developed using this reagent on real samples than both DFO and ninhydrin and a combination of the two reagents.  相似文献   

7.
Trace explosive test surfaces are often required for the evaluation of trace detection equipment to determine the equipment performance. Test surfaces of C‐4, Detasheet, Semtex‐H, TNT, and HMTD were prepared by transferring trace amount of explosive deposited on polytetrafluoroethylene (PTFE) transfer strips onto different surfaces (Kraft paper, hard plastic, woven fabric, and soft vinyl). The amount of explosive transferred was deduced from the amount of explosive remaining on the PTFE strips after transfer, as quantified by direct analysis using tandem mass spectrometry with thermal desorption. From the data set of over 2000 transfers, we experienced lower transfer efficiency for Semtex‐H and Detasheet, and for soft vinyl and hard plastic. However, the rapid quantification mass spectrometric method allowed the transfer efficiency to be determined for all test surfaces used in an evaluation of trace explosive detectors, thereby permitting only the test surfaces with desired transfer to be accepted for the assessment.  相似文献   

8.
Two-dimensional dust shoeprints are often of very high resolution and contain unique features. Lifting these prints in the most effective method may contribute much to preserving these fine details. A research was conducted by experts from Israel and Switzerland to compare gelatin lifters and electrostatic lifters for lifting shoeprints. Several substrates were chosen, and on each material a set of dry dust shoeprints was made. A set of wet prints was made on paper as well. The shoeprints were approximately of the same quality, and the only variable was the nature of the material. On substrates indifferent to the method used, the preferable sequence was tested. Gelatin lifter was superior on most substrates and for wet prints. The superior sequence for using both methods is electrostatic lifting followed by gelatin lifter.  相似文献   

9.
This study aimed to develop and to assess an algorithm to facilitate lip print visualization, and to digitally analyze lip prints on different supports, by superimposition. It also aimed to classify lip prints according to sex. A batch image processing algorithm was developed, which facilitated the identification and extraction of information about lip grooves. However, it performed better for lip print images with a uniform background. Paper and glass slab allowed more correct identifications than glass and the both sides of compact disks. There was no significant difference between the type of support and the amount of matching structures located in the middle area of the lower lip. There was no evidence of association between types of lip grooves and sex. Lip groove patterns of type III and type I were the most common for both sexes. The development of systems for lip print analysis is necessary, mainly concerning digital methods.  相似文献   

10.
Theoretically, a shoe that provides less friction could result in a greater slip distance and foot slipping velocity, thereby increasing the likelihood of falling. The purpose of this study was to investigate the effects of sole hardness on the probability of slip‐induced falls. Forty young adults were randomized into a hard or a soft sole shoe group, and tested under both nonslippery and slippery floor conditions using a motion analysis system. The proportions of fall events in the hard‐ and soft‐soled shoe groups were not statistically different. No differences were observed between shoe groups for average slip distance, peak and average heel velocity, and center of mass slipping velocity. A strong association was found between slip distance and the fall probability. Our results demonstrate that the probability of a slip‐induced fall was not influenced by shoe hardness. Once a slip is induced, slip distance was the primary predictor of a slip‐induced fall.  相似文献   

11.
Various types of cotton and polyester fabrics were tested to ascertain the optimal physical and chemical characteristics of fabrics needed for the removal of cellular material from surfaces. DNA quantitation values obtained on dried saliva stains showed no difference between cotton and polyester across all constructions and solvent conditions. Fabrics used dry and with water yielded higher quantitation values than those used with isopropanol. Quantitation values were also higher for wovens and nonwovens than knits across all solvent conditions. Low thread count fabrics used with water yielded higher quantitation values, but no correlation between thread count and quantitation values was observed with dry fabrics. A low thread count woven fabric, however, outperformed other tested fabrics when swabbing object surfaces in a highly used room. Full DNA profiles from fingerprints on glass surfaces were obtained with low thread count woven and nonwoven fabrics but not with the knit fabric tested.  相似文献   

12.
A combination absorption-elution, two-dimensional absorption-inhibition procedure was used to determine the ABH antigen composition of a series of human bone specimens of known ABO type that had been aged up to nine months under dry and humid conditions at ambient temperature, 37 degrees C, and 56 degrees C; at ambient temperature in dry and wet soil; and buried in soil outdoors. Grouping data for the separate elution and inhibition testing, as well as for the combination procedure, are given. The combination method was found to be a highly reliable procedure for bone tissue ABH typing. Some data on microbial contaminants of human bone specimens aging in soil, and their effects on ABH typing results, are presented. No direct correlation between the properties of microbial contaminants and specific changes in the ABH antigenic composition of aging bone tissue specimens could be ascertained. Data on IGH antigen determination and on the quantitation of immunoglobulin G (IgG) in human bone tissue extracts indicated that immunoglobulin levels were typically too low to expect routinely successful Gm antigen testing results. However, these factors can sometimes be determined in fresh bone tissue extracts, particularly if the extracts are concentrated.  相似文献   

13.
Abstract

Symptom Validity Testing (SVT) has been proposed as a method to assess the veracity of claims of amnesia. Performance below chance levels on a forced choice task is indicative of malingering. Previous research has shown that the Symptom Validity Test is a promising challenge test: at levels of high specificity, it may detect approximately half of those who malinger. The present study investigated the effect of coaching on the sensitivity of the Symptom Validity Test. Participants were instructed to feign complete amnesia and tested about their identity using the Symptom Validity Test. Half of the participants were coached not to perform below chance levels. Results were straightforward: 58% of 19 naive malingerers were detected, but none of 19 coached malingerers were detected. The results show that the Symptom Validity Test is not resistant to coaching.  相似文献   

14.
《Science & justice》2020,60(5):473-479
Powder suspensions such as wet powder are used to develop fingermarks on adhesive surfaces. They can also be used on gloves but these ready-to-use commercial pre-mixed solutions are not entirely satisfactory. Among other things, they generate some background noise that can sometimes be substantial and make the exploitation of the fingermarks difficult. Recent studies have proven the effectiveness of a HFE ninhydrin solution on some types of gloves. Ninhydrin and 1,2-indanedione are reagents that are commonly used for the visualisation of fingermarks on porous and semi-porous substrates. Applying them on gloves might help to overcome the issue of background noise being produced by powder suspensions. In this study, several formulations of ninhydrin and 1,2-indanedione are compared to wet powder on a sample of nitrile, latex and vinyl gloves. The subsequent results show a greater effectiveness with the use of wet powder.  相似文献   

15.
A rapid colorimetric test for the detection of gamma-hydroxybutyric acid (GHB) is described. The ferric hydroxamate test for ester detection has been adapted to detect GHB in human urine samples from a healthy female and a healthy male subject. The assay can be performed within 5 min and with a GHB detection limit of 0.5 mg/ml when 0.3 ml of human urine is used and a GHB detection limit of 0.1 mg/ml when 1 ml of human urine is used. The colored complex indicating the presence of GHB is purple according to the assay conditions. Test results are free from the interference by alcohol, phenolic compounds and other biological chemicals under the assay conditions. In addition, the colorimetric test is free from the potential false-positive test result that could result from physiological concentrations of GHB.  相似文献   

16.
目的研究水浸客体表面潜指纹的显现方法;方法利用CdSe巯基乙酸溶液显现被水浸泡过的黄色封箱胶带、黑色塑料袋、玻璃等常见非渗透性客体上的潜手印,讨论影响水浸非渗透性客体上潜手印显现效果的各种因素,并与传统方法进行比较,初步探讨了CdSe巯基乙酸溶液显现水浸非渗透性客体表面潜手印的方法;结果使用巯基乙酸包覆CdSe纳米复合材料显现潜在手印,使每分子纳米复合材料外表包覆足够数量的羧基,则可以提高它同手印残留物的结合能力,从而得到更高清晰度、更高分辨率的手印显像;结论巯基乙酸包覆CdSe纳米复合材料可以很好的显现水浸塑料、胶带等表面潜指纹。  相似文献   

17.
Commercially available skin cleansing alcohol wipes and conventional swabs were investigated for their use as a universal sampling medium for the simultaneous collection of both organic and inorganic explosive residues. Six compounds with the potential to be encountered in casework [pentaerythritol tetranitrate (PETN), 2,4,6-trinitrotoluene (TNT), hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX), triacetone triperoxide (TATP), ammonium nitrate, and sodium chlorate] were selected as representative target compounds. Quantities of these target compounds were deposited on four different substrates (glass, plastic, aluminium foil and laminate). Two chosen alcohol wipes demonstrated better overall performance in the recovery of both the organic and inorganic representative compounds from each of the test surfaces compared to the results obtained using conventional cotton and polyester swabs, pre-moistened with various solvents, and a direct methanol wash (used as a control). Results obtained using dry cotton swabs indicated that it was not an effective swabbing system for the collection of both organic and inorganic explosive residues on common substrates.  相似文献   

18.
In the process of fingerprint development Physical Developer has been largely the method of choice on porous surfaces after coming into contact with wet environments. It is only recently that a new technique has been identified which could replace this standard technique. This study aims to build on previous research and expand knowledge regarding the technique. The study built on previous research and compared Physical Developer to Oil Red O, testing both on four paper types, while being placed in three different water types and an accelerant for various amounts of time. Marks were placed with both heavily ‘loaded’ sebaceous fingers and ‘normal’ un-washed fingers. Results show that Oil Red O consistently produced clearer more detailed marks from the ‘loaded’ fingers, but neither technique proved to work better on the ‘normal’ marks. Neither technique developed any prints from the accelerant.  相似文献   

19.
In this study, we aimed to explore the possibility of DNA analysis of areca nut as material evidence and the value of short tandem repeat (STR) typing of areca nut as material evidence under the condition of simulating external environment. In this study, water soaking, soil burial, sun exposure, and wet environment were used to treat areca nut residues. Chelex 100 was used to extract DNA, the PowerPlex21 kit to amplify, and the ABI PRISM® 310 Genetic Analyzer to analyze the DNA of areca nut residues. DNA and STR typing were performed to analyze the residue after chewing. The results showed that the number of residual sites decreased with time under the conditions of water soaking, soil burial, sun exposure, and wet environment. Thus, areca nut can be used as forensic material evidence for DNA analysis and individual identification.  相似文献   

20.
The volume of bloodstains found on crime scenes may help forensic investigators reconstruct the location and kinematics of bloodletting events, as stain size, volume, and impact velocity are related. Optical coherence tomography was used as a method to determine the volume and volume ratio of dried and fresh bloodstains on both glass and irregular surfaces or deposited with an impact velocity. The volume of blood drops deposited on smooth glass surfaces was measured within a deviation of 2%. This deviation increased for droplets on irregular surfaces or deposited with an impact velocity. The volume ratio of dried and fresh bloodstains was equal to 19–28% depending on the individual donor and on the use of an anticoagulant. Optical coherence tomography is a good method to determine the volume of fresh and dried bloodstains in laboratory conditions and allows accurate determination of the dry/fresh ratio.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号