1.
We describe the developmental validation study performed on the PowerPlex® ESX 16 (European Standard Extended 16) and the PowerPlex® ESX 17 Systems, part of a suite of four new DNA profiling kits developed by Promega in response to the ENFSI and EDNAP groups’ call for new STR multiplexes for Europe. The PowerPlex® ESX 16 System combines the 11 loci compatible with the UK National DNA Database, contained within the AmpFlSTR® SGM Plus® PCR Amplification Kit, with five additional loci: D2S441, D10S1248, D22S1045, D1S1656 and D12S391. The multiplex was designed to incorporate these five new loci as mini- and midi-STRs while maintaining the loci found in the AmpFlSTR® SGM Plus® kit as standard size. The PowerPlex® ESX 17 System amplifies the same loci as the PowerPlex® ESX 16 System, but with the addition of a primer pair for the SE33 locus. Tests were designed to address the developmental validation guidelines issued by the Scientific Working Group on DNA Analysis Methods (SWGDAM), and those of the DNA Advisory Board (DAB). Samples processed include DNA mixtures, PCR reactions spiked with inhibitors, a sensitivity series, and 306 United Kingdom donor samples to determine concordance with data generated with the AmpFlSTR® SGM Plus® kit. Allele frequencies from 242 white Caucasian samples collected in the United Kingdom are also presented. The PowerPlex® ESX 16 and ESX 17 Systems are robust and sensitive tools, suitable for the analysis of forensic DNA samples. Full profiles were routinely observed with 62.5 pg of a fully heterozygous single source DNA template. In mixture analysis, a range of 52-95% of unique minor contributor alleles was observed at 19:1 mixture ratios where only 25 pg of the minor component was present. Improved sensitivity combined with the robustness afforded by smaller amplicons has substantially improved the quantity of information obtained from degraded samples, and the improved chemistry confers exceptional tolerance to high levels of laboratory prepared inhibitors.  相似文献   

2.
We studied the allele frequency distribution of 21 autosomal STR loci contained in the AmpFlSTR® Identifiler™ (Applied Biosystems), the Powerplex®16 (Promega) and the FFFL (Promega) multiplex PCR kits among 936 individuals from the Royal Kingdom of Bhutan. As such these are the first published autosomal DNA results from this country.  相似文献   

3.
Forensic DNA analysis is a multi-step process involving extraction of DNA, quantification of human DNA in the extract, amplification using multiplex STR systems, separation of products, and data analysis. The backlog of forensic casework is increasing worldwide. Automation is one significant way to alleviate the bottleneck of sample processing in forensic labs. The HID EVOlution™ Combination System described here is a robust, reliable sample processing platform, easily adapted to forensic laboratory workflows. Using a variety of forensic sample types including: blood stained FTA paper, cotton fabric and denim, dried blood spiked with known PCR inhibitors, saliva on cotton swabs, and semen stains, we found that yields of human DNA and STR profiles obtained with AmpFlSTR® Idenitfiler® kits were complete, highly reproducible, and equivalent to results obtained using the manual PrepFiler™ reagent extraction method. Automated operation was clean, and no cross-contamination was detected between extraction blanks and interspersed high DNA content samples.  相似文献   

4.
Abstract: This paper reports the results of a commission to develop a field deployable rapid short tandem repeat (STR)‐based DNA profiling system to enable discrimination between tissues derived from a small number of individuals. Speed was achieved by truncation of sample preparation and field deployability by use of an Agilent 2100 BioanalyserTM. Human blood and tissues were stabbed with heated stainless steel wire and the resulting sample dehydrated with isopropanol prior to direct addition to a PCR. Choice of a polymerase tolerant of tissue residues and cycles of amplification appropriate for the amount of template expected yielded useful profiles with a custom‐designed quintuplex primer set suitable for use with the BioanalyserTM. Samples stored on wires remained amplifiable for months, allowing their transportation unrefrigerated from remote locations to a laboratory for analysis using AmpFlSTR® Profiler Plus® without further processing. The field system meets the requirements for discrimination of samples from small sets and retains access to full STR profiling when required.  相似文献   

5.
Since its introduction in 2002, the AmpF?STR® SEfiler™ kit has provided a highly discriminating DNA profiling option to German forensic laboratories by combining the widely used SGM Plus® Kit loci with the SE-33 locus required for the German DNA Database. Whilst proving successful on database samples, laboratories using the SEfiler™ kit have reported the need for chemistry better able to handle the ever-increasing number of casework samples.The new AmpF?STR® SEfiler Plus™ kit contains the same loci and primer sequences as the SEfiler™ kit but uses improved synthesis and purification processes to minimize the presence of dye-labeled artifacts. Other improvements include modified PCR cycling conditions for enhanced sensitivity and a new buffer formulation that improves performance with inhibited samples when compared to the original SEfiler™ kit.Validation studies demonstrating the effectiveness of the multiplex are presented with emphasis on the models of inhibition and casework samples.  相似文献   

6.
We have implemented and validated customized protocols for automated Quantifiler® setup, template normalization and PCR setup using the Tecan HID EVOlution™ qPCR/STR setup. The protocols were validated for the Quantifiler® human DNA quantification, AmpF?STR® SGM Plus® and SEfiler Plus™ PCR Amplification Kits (Applied Biosystems) according to EN/ISO 17025.  相似文献   

7.
Forensic laboratories employ various approaches to obtain short tandem repeat (STR) profiles from minimal traces (<100 pg DNA input). Most approaches aim to sensitize DNA profiling by increasing the amplification level by a higher cycle number or enlarging the amount of PCR products analyzed during capillary electrophoresis. These methods have limitations when unequal mixtures are genotyped, since the major component will be over-amplified or over-loaded. This study explores an alternative strategy for improved detection of the minor components in low template (LT) DNA typing that may be better suited for the detection of the minor component in mixtures. The strategy increases the PCR amplification efficiency by extending the primer annealing time several folds. When the AmpF?STR® Identifiler® amplification parameters are changed to an annealing time of 20 min during all 28 cycles, the drop-out frequency is reduced for both pristine DNA and single or multiple donor mock case work samples. In addition, increased peak heights and slightly more drop-ins are observed while the heterozygous peak balance remains similar as with the conventional Identifiler protocol. By this extended protocol, full DNA profiles were obtained from only 12 sperm heads (which corresponds to 36 pg of DNA) that were collected by laser micro dissection. Notwithstanding the improved detection, allele drop-outs do persist, albeit in lower frequencies. Thus a LT interpretation strategy such as deducing consensus profiles from multiple independent amplifications is appropriate. The use of extended PCR conditions represents a general approach to improve detection of unequal mixtures as shown using four commercially available kits (AmpF?STR® Identifiler, SEfiler Plus, NGM and Yfiler). The extended PCR protocol seems to amplify more of the molecules in LT samples during PCR, which results in a lower drop-out frequency.  相似文献   

8.
Validation of the AmpF?STR® SEfiler Plus™ PCR Amplification kit with 29 and 30 PCR cycles for forensic STR analysis demonstrated that the kit had fewer artefacts than the AmpF?STR® SGM Plus™ kit (28 PCR cycles). The SEfiler Plus kit was more sensitive and devoid of colour artefacts, but showed more stutters, drop-ins, drop-outs and allelic imbalances.  相似文献   

9.
We have implemented and validated automated methods for washing FTA Card punches containing buccal samples and subsequent PCR setup using a Sias Xantus automated liquid handler. The automated methods were controlled by worklists generated by our LabWare Laboratory Information Management System (LIMS). The protocols were validated according to EN/ISO 17025 for use with STR amplifications kits AmpF?STR® Identifiler® and Y-filer® (Applied Biosystems).  相似文献   

10.
The transfer of DNA from hands to objects by holding or touching has been examined in the past. The main purpose of this study was to examine the variation in the amount of DNA transferred from hands to glass, fabric and wood. The study involved 300 volunteers (100 for glass, 100 for fabric and 100 for wood) 50% of which were male and 50% female. The volunteers held the material for 60 s. The DNA was recovered from the objects using a minitape lift, quantified using the Quantifiler kit assay, extracted using a ‘Qiagen® QIAamp DNA mini kit’ and amplified using the AmpFlSTR® SGM Plus™ Amplification Kit at 28 cycles. The results show that using ANOVA there was a significant difference (F = 8.2, p < 0.05) between the three object types in the amount of DNA recovered. In terms of DNA transfer and recovery, wood gave the best yield, followed by fabric and then glass. The likelihood of success of obtaining a profile indicative of the holder was approximately 9% for glass samples, 23% for fabric and 36% for wood. There was no significant difference between the amount of DNA transferred by male or female volunteers. In this study good shedder status, as defined by obtaining useful profiles of 6 or more alleles, is estimated at approximately 22% of the population. The phenomenon of secondary transfer was observed when mixed DNA profiles were obtained but the incidence was low at approximately 10% of the total number of samples. DNA profiles corresponding to more than one person were found on objects which had been touched by only one volunteer. Although secondary transfer is possible the profiles obtained from touched objects are more likely to be as a result of primary transfer rather than a secondary source.  相似文献   

11.
The allele frequencies of eight MiniFiler™ loci have been analyzed in 101 Japanese individuals living in Kanagawa with informed consent by means of ABI 310 Genetic Analyzer. A total of 7 alleles for D13S317, 8 alleles for D7S820, 11 alleles for D2S1338, 11 alleles for D21S11, 5 alleles for D16S539, 14 alleles for D18S51, 8 alleles for CSF1PO, and 13 alleles for FGA were observed. The polymorphic profiles of these MiniFiler™ loci in the present study were essentially the same as those obtained by using the AmpFlSTR® Identifiler® PCR Amplification kit. The combined matching probability of eight MiniFiler™ loci and cumulative probability of paternity exclusion were estimated as 1.97 × 10−10 and 0.9996, respectively. The MiniFiler™ kit was useful for individual identification in forensic analysis.  相似文献   

12.
Abstract: Archived slides of cell smears treated with histological stains for sperm detection are often the only source of DNA available when cold cases are reopened. There have been conflicting reports as to the negative effects of particular histological stains on DNA recovery and quality from human cells, making stain selection an important consideration for forensic laboratories. This study investigates the effect of several staining systems on DNA recovery from histological slide samples stored from 0 to 10 weeks. DNA profiles obtained after analysis of these samples with AmpFlSTR® Identifiler? and increased cycle AmpFlSTR® SGM Plus? short tandem repeat (STR) profiling systems and the effects that these stains have on DNA quantity and quality over time are described. Results indicate that Christmas Tree and Hematoxylin and Eosin stains do not have significantly different effects on DNA quality after 10‐week storage of slides. This research will assist scientists to select staining systems that have minimal deleterious effects on the DNA recovered.  相似文献   

13.
FTA Cards (GE Healthcare) have been used for more than 4 years in Denmark for the collection of buccal cells as reference samples in crime cases. Semi-automated protocols for STR typing of DNA on punches of FTA Cards are routinely used. In average, full STR profiles were generated from approximately 95% of the FTA Cards with a standard punching protocol, while partial or no STR profile were obtained from 5% of the samples. Here, the Qiagen BioRobot® EZ1 Workstation (Qiagen) and the EZ1 DNA Investigator Kit (Qiagen) was used to extract DNA from 29 FTA Cards from which a complete STR profile was not generated with the standard punching protocol. All 29 samples were successfully typed with the AmpF?STR® Identifiler™ PCR Amplification Kit (Applied Biosystems) and with the SNPforID 49plex SNP assay. The lowest amount of DNA that resulted in complete STR and SNP profiles was 80 pg. The STR and SNP profiles were identical to those generated from another sample collected from each of the 29 individuals.  相似文献   

14.
Forensic analysts routinely encounter samples containing DNA mixtures from male and female contributors. To obtain interpretable Short Tandem Repeat (STR) profiles and select the appropriate STR analysis methodology, it is desirable to determine relative quantities of male and female DNA, and detect PCR inhibitors. We describe a multiplex assay for simultaneous quantification of human and human male DNA using the ribonuclease P RNA component H1 (RPPH1) human target and the sex determining region Y (SRY) male-specific target. A synthetic oligonucleotide sequence was co-amplified as an internal PCR control. Standard curves were generated using human male genomic DNA. The SRY and RPPH1 assays demonstrated human specificity with minimal cross-reactivity to DNA from other species. Reproducible DNA concentrations were obtained within a range of 0.023-50 ng/μl. The assay was highly sensitive, detecting as little as 25 pg/μl of human male DNA in the presence of a thousand-fold excess of human female DNA. The ability of the assay to predict PCR inhibition was demonstrated by shifted IPC Ct values in the presence of increasing quantities of hematin and humic acid. We also demonstrate the correlation between the multiplex assay quantification results and the strength of STR profiles generated using the AmpF?STR®PCR Amplification kits.  相似文献   

15.
Abstract: The quality and efficiency of a standard organic DNA isolation method and a silica‐based method using the QIAGEN Blood Maxi Kit were compared to obtain human DNA and short tandem repeats (STRs) profiles from 39 exhumed bone samples for paternity testing. DNA samples were quantified by real‐time PCR, and STR profiles were obtained using the AmpFlSTR® Identifiler® PCR amplification kit. Overall, the silica‐based method recovered less DNA ranging from 0 to 147.7 ng/g (average 7.57 ng/g, median = 1.3 ng/g) than did the organic method ranging from 0 to 605 ng/g (average 44.27 ng/g, median = 5.8 ng/g). Complete profiles (16/16 loci tested) were obtained from 37/39 samples (95%) using the organic method and from 9/39 samples (23%) with the silica‐based method. Compared with a standard organic DNA isolation method, our results indicate that the published silica‐based method does not improve neither the quality nor the quantity of DNA for STR profiling.  相似文献   

16.
Abstract: Forensic anthropologists routinely macerate human bone for the purposes of identity and trauma analysis, but the heat and chemical treatments used can destroy genetic evidence. As a follow‐up to a previous study on nuclear DNA recovery that used pig ribs, this study utilizes human skeletal remains treated with various bone maceration techniques for nuclear DNA amplification using the standard Combined DNA Index System (CODIS) markers. DNA was extracted from 18 samples of human lower leg bones subjected to nine chemical and heat maceration techniques. Genotyping was carried out using the AmpF?STR® COfiler® and AmpF?STR® Profiler Plus® ID kits. Results showed that heat treatments via microwave or Biz/Na2CO3 in sub‐boiling water efficiently macerate bone and produce amplifiable nuclear DNA for genetic analysis. Long‐term use of chemicals such as hydrogen peroxide is discouraged as it results in poor bone quality and has deleterious effects on DNA amplification.  相似文献   

17.
We have implemented and validated automated methods for DNA extraction and PCR setup developed for a Tecan Freedom EVO® liquid handler mounted with a Te-MagS™ magnetic separation device. The DNA was extracted using the Qiagen MagAttract® DNA Mini M48 kit. The DNA was amplified using AmpF?STR® Identifiler®, Y-filer® (Applied Biosystems), GenePrint® FFFL and PowerPlex® Y (Promega). The methods were validated for fresh whole blood and blood from deceased according to EN/ISO 17025.  相似文献   

18.
Manual Chelex®-100 and organic extractions (phenol/chloroform) are used as routine methods at the Swedish National Laboratory of Forensic Science, SKL. The aim of this study was to find an automated DNA purification system to replace the organic method. The following methods were evaluated and compared to each other and to the organic method used routinely; BioRobot® EZ1 with EZ1 DNA Investigator Kit and Card (Qiagen), iPrep™ Purification Instrument with iPrep™ ChargeSwitch® Forensic Kit and Card (Invitrogen), Magnatrix™ 1200 Workstation with the Magnatrix™ gDNA Blood Kit Forensic and two different protocols; Forensic protocol A and B (Magnetic Biosolutions). Blood on fats, cotton swabs, moist snuff, paper towels and leather, post-mortem blood and muscle tissue were extracted with the different methods. DNA concentration and quality of the electropherograms were examined. Individual comparisons between the four extraction methods showed that iPrep™ and Magnatrix™ 1200 gave significantly lower mean quantities compared to BioRobot® EZ1 and the organic extraction method (p < 0.05). There were no significant differences between the latter two. BioRobot® EZ1 generated the best results and is in the process of being validated for routine analysis at SKL.  相似文献   

19.
In cases of sexual assault involving an azoospermic assailant, vaginal swabs taken from the victim may fail to provide an autosomal DNA profile with which to search a suspect database, as the signal from any male cells present would be masked by that from the overwhelming number of female cells collected on the swab. Here, we describe a method of visually identifying diploid male cells in such samples using fluorescence in situ hybridisation, and selectively harvesting them by means of laser microdissection. This combination of techniques was tested on 26 post-coital vaginal swabs taken at a range of times after intercourse; the collected cells were then subjected to a simple lysis procedure and DNA was amplified using the AmpFlSTR® SGMPlus® multiplex under low copy number conditions. Useful DNA profiles were generated from samples taken up to 24 h after intercourse.  相似文献   

20.
As part of the normal procedure in a forensic DNA laboratory, a quality control step of the amplified DNA is often implemented to ensure the correct amplification of the sample before it is analysed in downstream applications. A validation study was undertaken to investigate a new microchip electrophoresis system (MultiNa, Shimadzu Corporation) claiming high resolution and sensitivity compared to routine polyacrylamide gel electrophoresis (PAGE). An array of STR multiplexes (AmpFISTR™ SGM+, GenePrint® FFFL, PowerPlex™ 16, PowerPlex™ Y, an in-house Y-STR multiplex and AmpFISTR™ Profiler) was tested under both standard and low copy number PCR parameters to evaluate the accuracy, reproducibility and sensitivity of this technique. These tests showed that the microchip system did not have improved sensitivity compared to PAGE though had increased resolution and high reproducibility between samples.  相似文献   