首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The properties of a bullet, an object, and the incidence angle determine whether the bullet will penetrate, perforate, or ricochet. In this study, the critical angle for ricochet was established for .32 Auto and 9 mm Luger bullets on Abachi, Southern Yellow Pine, Beech, and Ipe wooden boards. Results show that the critical angle differs depending on caliber and wood type. The critical angle is higher for .32 Auto bullets than for 9 mm Luger bullets and increases with increasing wood density and Janka hardness. The established critical angles for ricochet on the lightest and softest wood (Abachi) are 10.4° and 10.3° for .32 Auto and 9 mm Luger, respectively. For the heaviest and hardest wood (Ipe), the angles were 45.0° and 33.4°, respectively. The combined results on the four tested woods show a strong linear relationship between both the density and the hardness and the critical angle for both calibers.  相似文献   

2.
De‐identified wound data from 197 homicidal gunshot postmortems were obtained between 2000 and 2008. Forensic ballistics data were only available for cases between 2004 and 2008. Males represent 91% of gunshot victims and were struck in the thorax/abdomen with an average of 2.3 bullets. The type of firearms involved were semi‐automatic pistols in the predominant caliber 9‐mm Luger and assault rifles in caliber 5.56 × 45 mm and caliber 7.62 × 39 mm Soviet, using full metal jacket bullets. The majority of shootings occurred at ranges of 1 m or greater. The most common bullet path was front to back in 66% of cases. Entry wounds occurred more often on the left side of the thorax, abdomen, and back. The most common critical organs/tissues to sustain bullet trauma in descending order were as follows: heart, lungs, liver, aorta, spleen, kidneys, and vena cava. Ribs were struck by most bullets that entered the thorax.  相似文献   

3.
6 years after introduction of the police ammunition QD-P.E.P. (9 mm caliber), 9 bullet wounds are presented from forensic investigations along with the results of experimental shots at pig carcasses. The evaluation reveals the characteristic pattern of such bullet wounds: a skin defect which is almost as large as the caliber and has a sharp-edged border thus looking like it has been punched out; the contusion ring ("abrasion ring") is conspicuously narrow. These findings can be explained by the shape and design of the projectile. In regular police work immediate incapacitation has not always been achieved, depending on the entry location of the bullet. Experimental shots at pig carcasses showed that in the case of shots at extremities, the residual energy of the exiting bullet may be sufficient to generate another penetrating bullet wound.  相似文献   

4.
Measuring trajectory angles of bullet defects at a crime scene is an important part of crime scene investigation as these angles can be used for shooting incident reconstructions. The Washington State Patrol Crime Scene Response Team (WSP CSRT) had a desire to report and use measured trajectory angles. To report quantitative measurements, a statement of uncertainty for the measurement must also be reported due to an accreditation requirement through the ANSI National Accreditation Board (ANAB), through which the WSP CSRT is accredited. This evaluation examined the measurement uncertainty of the 3D laser scanning method that the WSP CSRT utilizes for measuring the vertical and azimuth angles from trajectory rods fitted to bullet defects. Three studies were performed which examined the variation of vertical and azimuth angle measurements from trajectory rods on flat surfaces, the variation of azimuth angle measurements from a trajectory rod on a curved surface, and a traceability study with known vertical and azimuth angle measurements. Seven common substrates were selected as target materials and were shot with 9 mm Luger and 0.45 Auto caliber bullets. A vehicle with one bullet defect was utilized for the curved surface study. The WSP's current fleet of Trimble X7 3D laser scanners, the WSP Criminal Investigation Division (CID) Detectives who operate these scanners, and the Forensic Scientists responsible for trajectory rod placement and angle measurements were utilized. An overall measurement uncertainty of +/− 2.6 degrees at an approximate 95% confidence interval was determined for all trajectory angles measured from trajectory rods.  相似文献   

5.
The elemental objects of the research study are: determination of time periods corresponding to gunshot residue particles (GSR) deposition after the shot from selected pistols and a revolver, and evaluation of the deposited particles number. For several shooting experiments were used a pistol CZ model 85, caliber 9 mm Luger with common ammunition 9 mm Luger FMJ Sellier & Bellot, a pistol CZ model 70, caliber 7.65 mm Browning (32 ACP) with common 7.65 mm Browning FMJ Sellier & Bellot ammunition and a revolver S&W Modell 60, barell length 2-1/8', cal. .38 Special with common Sellier&Bellot (FMJ) ammunition. The results of the study have indicated the behavior of GSR particles deposited after a single discharge. The overall time interval of GSR particles deposition and the number of deposited particles with the above mentioned arms and ammunition were established. The results can potentially be used for clarifying the situation at crime scenes and for subsequent interpretation of GSR evidential value in caseworks.  相似文献   

6.
Complications arise in the analysis of gunshot wounds to the maxillofacial region, when neither the projectile nor the gun is found at the crime scene. We simulated 5‐ and 15‐cm firing distances at a human mandible to investigate the external morphology of entrance wounds based on fire range. The ammunition models, .40‐caliber S&W, .380‐caliber, and 9 × 19‐mm Luger, were constructed with free‐form NURBS surfaces. In a dynamic simulation, projectiles were fired against mandibular body 3D model at 5 and 15 cm. All entrance wounds presented oval aspect. Maximum diameter and von Mises stress values were 16.5 mm and 50.8 MPa, both for .40‐caliber S&W fired at 5 cm. The maximum energy loss was 138.4 J for .40 S&W fired at 15 cm. In conclusion, the mandible was most affected by .40‐caliber S&W and morphological differences were observable in holes caused by different incoming projectile calibers fired at different distances.  相似文献   

7.
For shooting scene reconstruction purposes, knowledge about the ricochet behavior of bullets provides valuable information. In this study, the critical ricochet angles of four cartridge types were established on plain float glass. The estimates of the critical ricochet angles varied between cartridge types and were 21.0° for .32 Auto FMJ bullets, 15.8° for 9 mm Luger FMJ bullets, 17.6° for .45 Auto FMJ bullets, and 21.3° for 9 mm Luger, Action NP bullets. The corresponding ricochet and deflection angles per incidence angle varied depending on the state of the ricocheted bullets. The mean ricochet angles are always lower than the corresponding angles of incidence, and the mean ricochet angles for the FMJ bullets with undamaged jackets are lower than those of bullets where the jacket is either damaged or the bullet partially ricocheted and partially perforated. Mean ricochet angles are lower for undamaged FMJ bullets than for undamaged Action NP bullets.  相似文献   

8.
During criminal investigations involving firearms, the detection of gunshot residues (GSRs) is one of the most important evidences. In the present study, a new method to identify trace evidences of GSRs, deposited around the bullet entrance hole, in different types of fabrics used as targets, is described. The experiments were carried out using a 0.38-inch caliber revolver, and 9-mm and 0.40-inch caliber pistols. Testimonies of 2.25 cm(2) of the fabrics were cut around the bullet entrance and digested with 10% nitric acid. Antimony, barium, and lead were analyzed in the remaining solution using a sector field inductively coupled plasma mass spectrometer. The concentrations of the elements were detected at levels up to few microgram per square centimeter. The use of ternary graphics allowed us to identify specific patterns of distribution for blank samples and the clear distinction between the revolver and pistols used.  相似文献   

9.
Studies on ballistic trauma to the ribs and thorax, cranium, and long bones demonstrate the potential of obtaining a bullet caliber from an entrance wound. In order to validate prior research on caliber estimation in bone tissue and assess the viability of bullet type determination based on the macroscopic evidence at the entrance wound, thirty fleshed pork (Sus scrofa) shoulders (humeri) were shot with either lead or copper jacketed bullets in one of three calibers; 0.22, 9 mm, or 0.38. Overall, our findings are consistent with previous research indicating that calibers can be grouped into “small” and “large” categories. Bullet type, lead or copper jacket, can be ascertained based on cortical flaking and the analysis of materials deposited around the entry wound. The addition of this evidence holds value in cases where no firearm or ballistic evidence is recovered from a crime scene.  相似文献   

10.
In forensic science, the analysis of gunshot residues was traditionally done by the detection of lead (Pb), antimony (Sb) and barium (Ba) usually found in a primer. However, the recent development of lead-free ammunition represents a new challenge for ballistic specialists. This analysis study gunshot residues from primers and ammunitions in the area surrounding bullet holes, a very important tool to determine the shooting distance. The ammunitions used were 9 mm Luger and .38 spl + p calibers, where lead in the primer was replaced with strontium (Sr) and where the lead bullet was plated with copper (Total Metal Jacket). Gunshot analysis results were obtained using an energy dispersive X-ray microfluorescence spectrometer. The method allows the detection and quantification of strontium residues on the target up to a distance of 45 cm.  相似文献   

11.
Application of lead isotope analysis in shooting incident investigations   总被引:1,自引:0,他引:1  
A study was conducted to examine the potential of the considerable variability of the lead isotope compositions in bullets (projectiles) and primers in shooting incident investigations. Multiple-collector inductively coupled plasma mass spectrometry (MC-ICP/MS) was used to analyze lead isotopic compositions in projectiles, cartridge cases, firearms discharge residues (FDR) in barrels of firearms and in the gunshot entries. .22 caliber plain lead and plated ammunition and 9 mm Luger full metal jacket (FMJ) ammunition were employed in shooting experiments using semiautomatic pistols. Cotton cloth served as the target material and two firing distances were tested; 1 cm (near contact) and 2 m distances. It was observed that various mechanical or chemical means of cleaning do not completely remove lead deposits ("lead memory") from barrels of firearms. Nonetheless, it was shown that analysis of lead isotopic composition may provide valuable evidence in investigating specific scenarios of shooting incidents. For instance in a shoot-out where several firearms and ammunition brands are involved, it may be feasible to point out which ammunition and/or firearm caused a particular gunshot entry if the ammunition brands involved (bullets and primers) differ considerably in their lead isotopic composition.  相似文献   

12.
Several series of experiments were performed to study the distribution of GSR particles in seven directions in the surroundings of shooting firearm (pistol CZ 85 caliber 9 mm Luger). External and internal conditions and two different primer types were used for the shooting experiments. The results showed that maximum number of GSR particles could be found in the right front quadrant at a distance of 2–4 m with respect to the shooting firearm position and shooting direction. GSR particles were even found in distance 10 m from shooting firearm. A significant influence of climatic conditions on GSR distribution was confirmed.  相似文献   

13.
When a bullet punctures a surface, it leaves behind a bullet impact, which can be analyzed in order to determine the origin and trajectory path from which a bullet was discharged using many different scientific methods to reconstruct a shooting scene. The purpose of the research was to test the accuracy and repeatability of reconstructing the impact angle of single bullet impacts using the ellipse method. The research was conducted by firing various calibers of ammunition into drywall panels positioned at varying angles of incidence from 88° until ricochet occurred. This was done in order to determine which caliber type and angle of incidence are most accurate and precise for reconstructing a shooting scene. The study examined four caliber types fired into drywall panels, with 5 repeated shots for each of the 11 angles of incidence (n = 220). Furthermore, 31 participants partook in the study to estimate a bullet impact angle of incidence utilizing the ellipse method. The results show that the best performance (accuracy and repeatability) is seen with the measurements of the 0.45 caliber ammunition. When angle of incidences is low (<64°), the performance (accuracy and repeatability) was seen to be better in all caliber ammunitions. Overall, the data provided for single bullet impacts deposited in drywall show that the ellipse method is useful in providing measurements for most crime scene reconstruction purposes and has also demonstrated that results vary depending on the type of ammunition, firearm, and angle of incidence being examined.  相似文献   

14.
Recent years have been characterized by a series of publications in the field of firearms investigation questioning the reliability and objectivity of such examination. This research investigates new solutions to decrease the subjective component affecting the evaluation that follows the comparison of impressions left by a firearm on the surface of spent cartridge cases. An automatic comparison system based on 3D measurements has been developed and coupled to a bivariate evaluative model allowing assigning likelihood ratios. Based on a dataset of 79 pistols (all SIG Sauer 9 mm Luger caliber), the system shows a very high discriminating power and the LRs that it provides are very indicative of the true state under both the prosecution and the defense propositions. For example, likelihood ratios exceeding a billion are predominantly obtained when impressions originating from the same source are compared. The system is also characterized by relatively low rates (≤1%) of misleading evidence depending on the firearm considered.  相似文献   

15.
The Très Haute Vitesse (THV) bullet was introduced to meet the requirements of law enforcement officers, as an alternative to larger calibre fully jacketed bullets, since expanding or exploding bullets are not relevant in Europe. To examine the effect of the THV bullet in tissue, especially the size of the lesion and the degree of overpenetration, 11 recently killed pigs were shot with the weapons used by the Danish Police Force and a 9-mm pistol for reference. The ammunition was THV in the calibres 7.65 mm, 0.38, and 9 mm, using conventional fully jacketed bullets for comparison. The lesions were considerably larger when the THV bullet was used, the entry wound in particular, being roughly twice the diameter in the case of the THV bullet as compared to the fully jacketed bullet of similar calibre. Only one 7.65-mm THV bullet overpenetrated the target when fired against the thorax or abdomen of the pigs and then with only minimal residual energy. All fully jacketed 7.65-mm bullets, all 0.38 bullets, with the exception of one THV bullet, and all 9-mm bullets overpenetrated the target. The 7.65-mm THV bullet produced a lesion which in its extent resembled that of the fully jacketed 9-mm bullet, and should be a suitable alternative for the Danish Police Force.  相似文献   

16.
“Bullet wipe” is the material deposited by a bullet on any surface with which it comes into contact after it is fired and may contain debris from the gun barrel, including particles of primer and metal fragments from previously fired bullets. X‐ray analysis is a non‐destructive method by which traces of metallic elements can be visually detected. The analysis of osseous defects for radiodense bullet wipe (RBW) assists in determining the presence or absence of perforating gunshot wounds, especially in fragmented, skeletonized remains. The aim of our current study was to determine the frequency of RBW around entrance firearms injuries that perforated bone. We prospectively analyzed entrance gunshot wounds for RBW over a three‐year period using digital X‐ray analysis (n = 59). We retrospectively reviewed the corresponding autopsy reports to determine the frequency of RBW by biologic sex, reported ancestry, age‐at‐death, location of wound, manner of death, range of fire, bullet caliber, and presence of bullet jacket. Data were analyzed by Fisher's exact test or Chi‐square test with significance levels accepted at p < 0.05. RBW was present in 66% (n = 39) of examined cases. Decedent characteristics did not significantly alter RBW distribution, including biologic sex (p = 0.75), reported ancestry (p = 0.49), and age‐at‐death (p = 0.43). Additionally, the location of the osseous entrance gunshot wound, manner of death, range of fire, and cartridge caliber did not affect RBW detection. All cases involving non‐jacketed rounds (n = 5) showed RBW (p = 0.30). To our knowledge, this study is the first to report the frequency of RBW detection from osseous entrance gunshot wounds.  相似文献   

17.
Abstract: Pork ribs with intact muscle tissue were used in an experimental attempt to identify bullet wipe on bone at distances from 1 to 6 feet with 0.45 caliber, full metal jacket ammunition. This resulted in the unexpected finding of primer‐derived gunshot residue (GSR) deep within the wound tract. Of significance is the fact that the GSR was deposited on the bone, under the periosteum, after the bullet passed through a Ziploc® bag and c. 1 inch of muscle tissue. It is also important to note that the GSR persisted on the bone after the periosteum was forcibly removed. The presence of primer‐derived GSR on bone provides the potential to differentiate gunshot trauma from blunt trauma when the bone presents an atypical gunshot wound. In this study, the presence of gunshot primer residue at a distance of 6 feet demonstrates the potential for establishing maximum gun‐to‐target distance for remote shootings.  相似文献   

18.
Fundamental to any ballistic armour standard is the reference projectile that is to be defeated. Typically, for certification, consistency of bullets is assumed. Therefore, practical variations in bullet jacket dimensions can have far reaching consequences. Traditionally, internal dimensions could only be analysed by cutting bullets which rules out any subsequent ballistic assessment. Therefore, the use of a non-destructive X-ray computed tomography (CT) method is explored in this paper. A set of 10 bullets (9 mm DM11) was taken for analysing both intra and inter bullet jacket thickness variation. CT measurements of jacket thickness were validated with high resolution scanning electron microscope (SEM) images. An image based analysis methodology has been developed to extract the jacket thickness map and the centre of gravity. Thickness variations of the order of 200 μm were found commonly across all the bullets along the length and an angular variation of up to 100 μm was found in a few bullets. Jacket thickness and centre of gravity were also calculated for the same bullets after impact and the variations between the pre- and post-impacted bullets were compared, by establishing a common physical reference. The results show that the proposed CT scanning approach and subsequent image analysis method can bring out the statistical variations in bullet geometry pre- and post impact effectively.  相似文献   

19.
Two cases involving deadly bullet shots to the head are reported (entry wounds at the right temple, shots fired at absolutely close range, 7.65 or 9 mm caliber). In both cases bleeding was determined in the fissure of the right shoulder joint. This bleeding can be explained by hyperextension and extreme position of the joint at the time of the gun firing. Should further cases of bleeding be confirmed during additional autopsies, then this bleeding could be an indication of death "by one's own hand."  相似文献   

20.
The most popular handgun in Brazil is the single round-barrel caliber 0.38 revolver. In recent years, however, owing to the modernization of police arms and their availability on the legal and illicit markets, pistols have become increasingly popular and currently represent about 20% of police seizures. In a previous paper we presented a novel collection method for gunshot residues (GSR) using a sampling procedure based on ethylenediamine-tetraacetic acid (EDTA) solution as a complexing agent on moistened swabs with subsequent detection using sector field-high resolution-inductively coupled plasma-mass spectrometry (SF-HR-ICP-MS). In the present paper, we discuss the capability of this methodology to identify antimony (Sb), barium (Ba) and lead (Pb) on the hands of volunteers after shot tests with 9 mm and 0.40 in. caliber pistols. Two types of munitions were tested: 9 mm Taurus and clean range. The use of a technique with high sensitivity, such as SF-HR-ICP-MS, permits the identification of low concentrations (less than 1 microg/L) of metals in firearm residue and constitutes a powerful tool in forensic science. We also discuss the importance of the sampling procedure, including collection from a different body part than the gun hand of the suspect. Comparison of the analytical data obtained allows clear discrimination between samples from the hands of shooters and non-shooters.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号