首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 281 毫秒
1.
2.
“Bullet wipe” is the material deposited by a bullet on any surface with which it comes into contact after it is fired and may contain debris from the gun barrel, including particles of primer and metal fragments from previously fired bullets. X‐ray analysis is a non‐destructive method by which traces of metallic elements can be visually detected. The analysis of osseous defects for radiodense bullet wipe (RBW) assists in determining the presence or absence of perforating gunshot wounds, especially in fragmented, skeletonized remains. The aim of our current study was to determine the frequency of RBW around entrance firearms injuries that perforated bone. We prospectively analyzed entrance gunshot wounds for RBW over a three‐year period using digital X‐ray analysis (n = 59). We retrospectively reviewed the corresponding autopsy reports to determine the frequency of RBW by biologic sex, reported ancestry, age‐at‐death, location of wound, manner of death, range of fire, bullet caliber, and presence of bullet jacket. Data were analyzed by Fisher's exact test or Chi‐square test with significance levels accepted at p < 0.05. RBW was present in 66% (n = 39) of examined cases. Decedent characteristics did not significantly alter RBW distribution, including biologic sex (p = 0.75), reported ancestry (p = 0.49), and age‐at‐death (p = 0.43). Additionally, the location of the osseous entrance gunshot wound, manner of death, range of fire, and cartridge caliber did not affect RBW detection. All cases involving non‐jacketed rounds (n = 5) showed RBW (p = 0.30). To our knowledge, this study is the first to report the frequency of RBW detection from osseous entrance gunshot wounds.  相似文献   

3.
When a bullet punctures a surface, it leaves behind a bullet impact, which can be analyzed in order to determine the origin and trajectory path from which a bullet was discharged using many different scientific methods to reconstruct a shooting scene. The purpose of the research was to test the accuracy and repeatability of reconstructing the impact angle of single bullet impacts using the ellipse method. The research was conducted by firing various calibers of ammunition into drywall panels positioned at varying angles of incidence from 88° until ricochet occurred. This was done in order to determine which caliber type and angle of incidence are most accurate and precise for reconstructing a shooting scene. The study examined four caliber types fired into drywall panels, with 5 repeated shots for each of the 11 angles of incidence (n = 220). Furthermore, 31 participants partook in the study to estimate a bullet impact angle of incidence utilizing the ellipse method. The results show that the best performance (accuracy and repeatability) is seen with the measurements of the 0.45 caliber ammunition. When angle of incidences is low (<64°), the performance (accuracy and repeatability) was seen to be better in all caliber ammunitions. Overall, the data provided for single bullet impacts deposited in drywall show that the ellipse method is useful in providing measurements for most crime scene reconstruction purposes and has also demonstrated that results vary depending on the type of ammunition, firearm, and angle of incidence being examined.  相似文献   

4.
A bystander claimed to have been shot by a police officer, and CT scans were used to match qualitative and quantitative aspects of the unremoved bullet with police issued 9 mm Luger ammunition. CT scan methodology proved a valid approach for the measurement of bullets based on calculated measurement capability and correlation with “gold standard” physical measurement by vernier caliper. Measurements regarding length and base diameter, as well as length/diameter ratio, were insufficient to unambiguously identify a specific caliber, or a bullet of specific mass within a caliber class. It was, however, possible to exclude a bullet of specific design and mass with well‐characterized precision and accuracy values under selected CT scan conditions. A 9 mm Luger bullet (115 gr FMJ RN) was excluded from involvement in a shooting based on qualitative bullet shape combined with length, base, and ratio measurements of the bullet in‐situ for the victim.  相似文献   

5.
目的 探讨跳弹创形成的条件,研究跳弹在体内弹道学特点及致伤能力,建立跳弹创的诊断依据。方法选用国产54式手枪及56式半自动步枪,配用51式手枪弹及56式步枪弹以水磨石板为反跳靶体,射击约克夏种猪4头,复制出跳弹创模型12例。观察射入口、创道及着弹点特征。结果 跳弹的形成受靶体性状、弹头形态和速度、入射角与反跳角等条件因素的影响;在相同条件下高初速尖型弹头的反跳角<低初速圆型弹头;创道无明显瞬时空腔效应;根据实验结果建立了6项诊断依据。结论 正确诊断跳弹创对射击方向和距离、重建弹道、分析枪击目的、评估损伤程度有实用价值。  相似文献   

6.
目的观察橡胶弹射人口的形态特征,并探讨其法医学意义。方法使用9mm警用转轮手枪发射橡胶弹,在实验动物胸腹部侧面垂直射击,射击距离分别为紧密接触射击(0cm),相对接触射击(1~6cm),近距离射击(6-60cm)和远距离射击(60cm~有效射程25m)。92式手枪采取相同方式射击实验动物作为对照。观察射入口的形态特征,制作组织病理学切片,HE染色显微镜下观察。结果橡胶弹接触射击和近距离射击,射入口边缘整齐,有明显的擦拭轮、挫伤轮和火药斑纹;远距离射击,可见射人口边缘撕裂,挫伤轮明显增宽,皮下出血显著;与手枪弹射入口形态特征明显不同。结论9mm警用转轮手枪橡胶弹射入口典型的形态特征,可作为此类损伤的诊断指标。  相似文献   

7.
8.
Forensic pathologist use soot and/or stippling surrounding entrance gunshot wounds in categorizing range of fire. If absent, some pathologists suggest utilizing histology when the range is diagnostically critical. This study investigates the concordance of macroscopic and microscopic findings in estimating range of fire by evaluating gunshot entrance and exit wounds made through human tissue analogs at defined distances using two handgun calibers. Examination of over 150 entrance wounds verified the ease of visually detecting soot from a muzzle distance of contact to 1 foot (30.5 cm), and its absence at 9 feet (274.3 cm). Distinctly apparent was bullet wipe surrounding the entrance wounds regardless of muzzle distance. Although variations existed, dark material was histologically identified in many skin, soft tissue, and bone sections at all ranges with both calibers. These nonparallel results decrease the dependability of histology for range of fire estimation and reinforce using gross observation.  相似文献   

9.
The bullet evidence in the JFK assassination investigation was reexamined from metallurgical and statistical standpoints. The questioned specimens are comprised of soft lead, possibly from full-metal-jacketed Mannlicher-Carcano (MC), 6.5-mm ammunition. During lead refining, contaminant elements are removed to specified levels for a desired alloy or composition. Microsegregation of trace and minor elements during lead casting and processing can account for the experimental variabilities measured in various evidentiary and comparison samples by laboratory analysts. Thus, elevated concentrations of antimony and copper at crystallographic grain boundaries, the widely varying sizes of grains in MC bullet lead, and the 5-60 mg bullet samples analyzed for assassination intelligence effectively resulted in operational sampling error for the analyses. This deficiency was not considered in the original data interpretation and resulted in an invalid conclusion in favor of the single-bullet theory of the assassination. Alternate statistical calculations, based on the historic analytical data, incorporating weighted averaging and propagation of experimental uncertainties also considerably weaken support for the single-bullet theory. In effect, this assessment of the material composition of the lead specimens from the assassination concludes that the extant evidence is consistent with any number between two and five rounds fired in Dealey Plaza during the shooting.  相似文献   

10.
Postmortem magnetic resonance imaging (MRI) is rarely used for the radiologic assessment of gunshot injuries, although it has clear advantages over postmortem computed tomography (CT) with regard to the imaging of soft tissue injuries. Another benefit in using MRI is that lodged projectiles composed of nonferromagnetic material such as lead present only marginal metal artifacts compared with severe artifacts on CT. This case report presents CT and MRI findings in a case with two gunshot wounds to the neck: a perforating wound and a nonperforating wound with a lead bullet lodged in the cervical spine. The decedent underwent CT and MRI before the scheduled autopsy. A ring of radiopaque material under the dermis in the fatty tissue was identified at both entrance wounds on CT, which was indicative of contact shots. The perforating gunshot was clearly indicated on CT by bullet fragments along the wound channel through the perforated 6th cervical vertebra and the fractured cricoid cartilage at the exit wound. The second trajectory, however, was only assumed based on the presence of gunshot residues at the entrance wound and the position of the lodged bullet. The radiologic assessment was severely impeded by the metal artifacts on CT. Barely noticeable metal artifacts on MRI allowed for clear visualization of the soft tissue injuries and the ruptured medulla oblongata. Only MRI clarified the soft tissue injuries of the brainstem noninvasively, which could provide specific and graphic information on the rapidity of death and the incapacitation of the victim.  相似文献   

11.
De‐identified wound data from 197 homicidal gunshot postmortems were obtained between 2000 and 2008. Forensic ballistics data were only available for cases between 2004 and 2008. Males represent 91% of gunshot victims and were struck in the thorax/abdomen with an average of 2.3 bullets. The type of firearms involved were semi‐automatic pistols in the predominant caliber 9‐mm Luger and assault rifles in caliber 5.56 × 45 mm and caliber 7.62 × 39 mm Soviet, using full metal jacket bullets. The majority of shootings occurred at ranges of 1 m or greater. The most common bullet path was front to back in 66% of cases. Entry wounds occurred more often on the left side of the thorax, abdomen, and back. The most common critical organs/tissues to sustain bullet trauma in descending order were as follows: heart, lungs, liver, aorta, spleen, kidneys, and vena cava. Ribs were struck by most bullets that entered the thorax.  相似文献   

12.
Expanding bullets are preferred by law enforcement because of their wounding potential and ability to avoid over-penetration which could result in unintended targets being struck by bullets that perforate their intended targets. Expansion failure for jacketed hollow point (JHP) bullets is commonly attributed to several causes including damage to the bullet's cavity, velocity loss, bullet destabilization and materials from intermediate targets filling the bullet's cavity which can cause expansion failure when the bullet subsequently impacts a soft, fluid-based target such as human tissue or ballistic gelatin. In this study, JHP bullets were fired into ballistic gelatin after passing through selected intermediate targets representing items common to shooting incidents. Velocity loss and bullet destabilization were not factors that contributed to the JHP bullets that experienced expansion failure; however, materials obstructing the bullets' cavities and damage to the bullets' cavities were considered causes for some of the JHP bullet expansion failures. It was determined through this research that most of the target materials caused JHP bullet expansion failure when shored against the ballistic gelatin, but when placed at distances of 7 ft. from the ballistic gelatin, bullets fired through the same target materials did expand. This original and unique study produced findings that are of significant value to shooting incident reconstruction experts and other forensic professionals as shooting incidents can call into question a victim's proximity to a wall or door when a bullet(s) perforated such a target material.  相似文献   

13.
Complications arise in the analysis of gunshot wounds to the maxillofacial region, when neither the projectile nor the gun is found at the crime scene. We simulated 5‐ and 15‐cm firing distances at a human mandible to investigate the external morphology of entrance wounds based on fire range. The ammunition models, .40‐caliber S&W, .380‐caliber, and 9 × 19‐mm Luger, were constructed with free‐form NURBS surfaces. In a dynamic simulation, projectiles were fired against mandibular body 3D model at 5 and 15 cm. All entrance wounds presented oval aspect. Maximum diameter and von Mises stress values were 16.5 mm and 50.8 MPa, both for .40‐caliber S&W fired at 5 cm. The maximum energy loss was 138.4 J for .40 S&W fired at 15 cm. In conclusion, the mandible was most affected by .40‐caliber S&W and morphological differences were observable in holes caused by different incoming projectile calibers fired at different distances.  相似文献   

14.
In forensic science, the analysis of gunshot residues was traditionally done by the detection of lead (Pb), antimony (Sb) and barium (Ba) usually found in a primer. However, the recent development of lead-free ammunition represents a new challenge for ballistic specialists. This analysis study gunshot residues from primers and ammunitions in the area surrounding bullet holes, a very important tool to determine the shooting distance. The ammunitions used were 9 mm Luger and .38 spl + p calibers, where lead in the primer was replaced with strontium (Sr) and where the lead bullet was plated with copper (Total Metal Jacket). Gunshot analysis results were obtained using an energy dispersive X-ray microfluorescence spectrometer. The method allows the detection and quantification of strontium residues on the target up to a distance of 45 cm.  相似文献   

15.
The images of 66 gunshot entrance wounds with a defect on the back, a bullet in the body, hemorrhage along the wound track, and logical certainty that it was an entrance wound were collected from the files of a moderately busy medical examiner's office. Participants numbering 22 board‐certified forensic pathologists viewed a single digital archival image of each of the 66 entrance wounds randomly mixed with 74 presumptive exit wounds to determine whether they were entrance or exit wounds. The concordance rate for correctly identifying the 66 logically known entrance wounds was 82.8% with a range from 58% to 97%. This pilot study was conducted to provide an evidence‐based approach to the interpretation of the direction of gunshot wounds by reviewing pathologists with access only to archival photographs, and it is not a measure of the accuracy to distinguish entrance from exit wounds when given all of the circumstances.  相似文献   

16.
The presence of “chipping” or “flaking” around the edges of gunshot entry wounds has been described among the characteristics of gunshot wounds in bone. In this study, the real frequency of such a peculiar feature was investigated. The presence of “chipping” was assessed on 22 gunshot wounds fired at a near‐contact range on bovine ribs with 9‐mm bullets. As controls, five samples were shot with a 3 cm range, and five from 40 cm. In 77% of cases shot at near‐contact range, a detachment of small fragments of the upper layers of bone was detected, mainly with a circumferential disposition, whereas this feature was lacking in control samples. The study demonstrated the frequency of “chipping” and that it may probably be due to a combined ballistic effect of impact of the bullet itself and expansion of gases. It may be thus considered indicative of close‐range shots.  相似文献   

17.
The properties of a bullet, an object, and the incidence angle determine whether the bullet will penetrate, perforate, or ricochet. In this study, the critical angle for ricochet was established for .32 Auto and 9 mm Luger bullets on Abachi, Southern Yellow Pine, Beech, and Ipe wooden boards. Results show that the critical angle differs depending on caliber and wood type. The critical angle is higher for .32 Auto bullets than for 9 mm Luger bullets and increases with increasing wood density and Janka hardness. The established critical angles for ricochet on the lightest and softest wood (Abachi) are 10.4° and 10.3° for .32 Auto and 9 mm Luger, respectively. For the heaviest and hardest wood (Ipe), the angles were 45.0° and 33.4°, respectively. The combined results on the four tested woods show a strong linear relationship between both the density and the hardness and the critical angle for both calibers.  相似文献   

18.
During criminal investigations involving firearms, the detection of gunshot residues (GSRs) is one of the most important evidences. In the present study, a new method to identify trace evidences of GSRs, deposited around the bullet entrance hole, in different types of fabrics used as targets, is described. The experiments were carried out using a 0.38-inch caliber revolver, and 9-mm and 0.40-inch caliber pistols. Testimonies of 2.25 cm(2) of the fabrics were cut around the bullet entrance and digested with 10% nitric acid. Antimony, barium, and lead were analyzed in the remaining solution using a sector field inductively coupled plasma mass spectrometer. The concentrations of the elements were detected at levels up to few microgram per square centimeter. The use of ternary graphics allowed us to identify specific patterns of distribution for blank samples and the clear distinction between the revolver and pistols used.  相似文献   

19.
Abstract: Pork ribs with intact muscle tissue were used in an experimental attempt to identify bullet wipe on bone at distances from 1 to 6 feet with 0.45 caliber, full metal jacket ammunition. This resulted in the unexpected finding of primer‐derived gunshot residue (GSR) deep within the wound tract. Of significance is the fact that the GSR was deposited on the bone, under the periosteum, after the bullet passed through a Ziploc® bag and c. 1 inch of muscle tissue. It is also important to note that the GSR persisted on the bone after the periosteum was forcibly removed. The presence of primer‐derived GSR on bone provides the potential to differentiate gunshot trauma from blunt trauma when the bone presents an atypical gunshot wound. In this study, the presence of gunshot primer residue at a distance of 6 feet demonstrates the potential for establishing maximum gun‐to‐target distance for remote shootings.  相似文献   

20.
Bullet embolism is a relatively unusual complication of gunshot wounds. Embolism to the right atrium comprises <5% of all reported intravascular bullet emboli. We report an additional case of bullet embolus to the right atrium of a 0.38-caliber bullet following a gunshot wound to the chest. The intracardiac bullet was recognized radiologically on presentation, but the patient was hemodynamically stable and managed conservatively, with the bullet left in place. The missile remained within the heart without clinical significance for several years and was recovered from the right atrium only at the time of autopsy. To the best of our knowledge, this is the first documented case of a 0.38-caliber bullet which embolized to the right atrium and remained inconsequential for an extended period of time.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号