首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 39 毫秒
1.
Conventional Gas Chromatography‐Mass Spectrometry (GC‐MS) methods for the analysis of ignitable liquids (ILs) are usually time‐consuming, and the data produced are difficult to interpret. A fast IL screening method using direct analysis in real time mass spectrometry (DART‐MS) is proposed in this study. GC‐MS, QuickStrip DART‐MS, and thermal desorption DART‐MS methods were used to analyze neat ILs and thermal desorption DART‐MS without extraction was used to analyze ILs on five substrates (e.g., carpet, wood, cloth, sand, and paper). Compared to GC‐MS, DART‐MS methods generated different spectral profiles for neat ILs with more peaks in the higher mass range and also provided better detection of less volatile compounds. ILs on substrates were successfully classified (98 ± 1%) using partial least squares discriminant analysis (PLS‐DA) models based on thermal desorption DART‐MS data. This study shows that DART‐MS has great potential for the high‐throughput screening of ILs on substrates.  相似文献   

2.
Abstract: In fire debris analysis, weathering of ignitable liquids and matrix interferences can make the identification of ignitable liquid residues (ILRs) difficult. An objective method was developed to associate ILRs with the corresponding neat liquid with discrimination from matrix interferences using principal components analysis (PCA) and Pearson product moment correlation (PPMC) coefficients. Six ignitable liquids (gasoline, diesel, ultra pure paraffin lamp oil, adhesive remover, torch fuel, paint thinner) were spiked onto carpet, which was burned, then extracted using passive headspace extraction, and analyzed by gas chromatography‐mass spectrometry. Both light and heavy burn conditions were investigated. In the PCA scores plot, ignitable liquids were discriminated based on alkane and aromatic content. All ILRs were successfully associated with the corresponding neat liquid using both PCA and PPMC coefficients, regardless of the extent of burning. The method developed in this research may make the association of ILRs with corresponding neat liquids more objective.  相似文献   

3.
Identification of an ignitable liquid in fire debris evidence can be complicated due to evaporation of the liquid, matrix interferences, and thermal degradation of both the liquid and the matrix. In this research, liquids extracted from simulated fire debris were compared to the original liquid using multivariate statistical procedures. Neat and evaporated gasoline and kerosene standards were spiked onto nylon carpet, which was subsequently burned. The ignitable liquid residues were extracted using a passive headspace procedure and analyzed by gas chromatography-mass spectrometry. Pearson product moment correlation coefficients, hierarchical cluster analysis, and principal components analysis were used to compare the liquids extracted from the carpet to the corresponding neat liquid. For each procedure, association of the extracts according to liquid type was possible, albeit not necessarily to the specific evaporation level. Of the three procedures investigated, principal components analysis offered the most promise since contributions from matrix interferences were essentially eliminated.  相似文献   

4.
Gas chromatography-mass spectrometry was used to compare gasoline samples obtained from different sources based on the difference in amounts of certain components found in the headspace of gasoline using target response data. Many suspected arson cases involve comparing an ignitable liquid extracted from fire debris to a liquid found in a suspect's possession to determine if they could have had a common source. Various component ratios are proposed for determining if an unevaporated gasoline sample could have originated from the same source as an evaporated gasoline extracted from fire debris. Fifty and 75% evaporated gasoline samples were both found to contain similar ratios of certain components when compared with its unevaporated source gasoline. The results of the comparisons in this study demonstrate that for cases involving gasoline that has been evaporated up to 50% and extracted from pine, it is possible to eliminate comparison samples as originating from the same source. The results of the 75% comparisons suggest it may be possible to apply the same type of comparison to cases involving 75% evaporated gasoline.  相似文献   

5.
Alternative fuels, specifically biodiesel, biodiesel blends, and E85 fuel, have been gaining a market share over the past few years. With the emergence of these fuels, fire debris analysts should be able to recognize their characteristics since these fuels may be encountered in casework. In this study, pure biodiesel (B100) and a 20% blend of pure biodiesel with petroleum diesel (B20) are examined as liquids and are extracted from debris samples using both passive headspace concentration and solvent extraction. Typical fire debris instrumental conditions are used to analyze these samples. Components of B100 and B20 may be observed in debris samples extracted using the passive headspace concentration method, but the chromatographic patterns are different from the pure liquid samples. When solvent extraction is used as a secondary extraction method on debris samples, the resulting patterns are consistent with the pure liquids of B100 and B20. E85 fuel, a blend of 85% ethanol and 15% gasoline, can be extracted using a typical fire debris extraction technique but requires slight modifications to typical fire debris instrumental conditions. E85 is shown at various stages of evaporation to demonstrate the resiliency of the ethanol. Additionally, samples of E85 were placed on carpet, burned and extinguished to demonstrate the effects of the suppression medium on the retention of ethanol.  相似文献   

6.
Distortion of the chromatographic profile obtained for hydrocarbons that have been sampled by adsorption onto activated charcoal is a well-known phenomenon. The work reported here helps to better define the causes of chromatographic profile distortion and offers a potential method to avoid chromatographic distortion in some cases through a subsampling technique. The recovery of hydrocarbons from an equimolar mixture was investigated to determine the influence of hydrocarbon concentration on the molar ratios of recovered components. In a one-quart container, hydrocarbon volumes as small as 24 microL (liquid) were sufficient to saturate the surface area available for adsorption on a 99.0 mm2 square of activated charcoal, resulting in significant distortions in the molar ratio and the chromatographic profile of the recovered hydrocarbons. Passive headspace sampling of a similarly small volume of unweathered gasoline spiked onto carpet padding resulted in a significant distortion of the chromatographic profile. The chromatographic profile of the recovered hydrocarbons closely resembled 75% weathered gasoline. Heating the container spiked with unweathered gasoline to evenly distribute the components and then removing a subsample of the carpet padding to a second container for passive headspace analysis greatly reduced the amount of distortion in the resulting chromatogram.  相似文献   

7.
Compound-specific isotope analysis offers potential for fingerprinting of diesel fuels, however, possible confounding effects of isotopic fractionation due to evaporation need to be assessed. This study measured the fractionation of the stable carbon and hydrogen isotopes in n-alkane compounds in neat diesel fuel during evaporation. Isotope ratios were measured using a continuous flow gas chromatograph/isotope ratio mass spectrometer. Diesel samples were progressively evaporated at 24 ± 2°C for 21 days. Increasing depletion of deuterium in nC12nC17 alkanes in the remaining liquid with increasing carbon chain length was observed. Negligible carbon isotope fractionation was observed. Preferential vaporization was measured for the shorter chain n-alkanes and the trend decreased with increasing chain length. The decrease in δ2H values indicates the preferential vaporization of the isotopically heavier species consistent with available quantitative data for hydrocarbons. These results are most important in the application of stable isotope technology to forensic analysis of diesel.  相似文献   

8.
Chemical fingerprinting of unevaporated automotive gasoline samples   总被引:3,自引:0,他引:3  
The comparison of two or more samples of liquid gasoline (petrol) to establish a common origin is a difficult problem in the forensic investigation of arsons and suspicious fires. A total of 35 randomly collected samples of unevaporated gasoline, covering three different grades (regular unleaded, premium unleaded and lead replacement), were examined. The high-boiling fraction of the gasoline was targeted with a view to apply the techniques described herein to evaporated gasoline samples in the future.A novel micro solid phase extraction (SPE) technique using activated alumina was developed to isolate the polar compounds and the polycyclic aromatic hydrocarbons (PAHs) from a 200microl sample of gasoline. Samples were analysed using full-scan gas chromatography-mass spectrometry (GC-MS) and potential target compounds identified. Samples were then re-analysed directly, without prior treatment, using GC-MS in selected ion monitoring (SIM) mode for target compounds that exhibited variation between gasoline samples. Principal component analysis (PCA) was applied to the chromatographic data. The first two principal components (PCs) accounted for 91.5% of the variation in the data. Linear discriminant analysis (LDA) performed on the PCA results showed that the 35 samples tested could be classified into 32 different groups.  相似文献   

9.
A new, fast, and ultra-sensitive headspace sampling method using the Capillary Microextraction of Volatiles (CMV) device is demonstrated for the analysis of ignitable liquid residues (ILRs) in fire debris. This headspace sampling method involves the use of a heated can (60°C) to aid in the recovery of volatile organic compounds (VOCs) from medium and heavy petroleum distillates. Our group has previously reported the utility of CMV to extract gasoline at ambient temperature in less than 5 min in the field. This work evaluates the recovery and analysis of low mass loadings (tens of ng) of VOCs from charcoal lighter fluid, kerosene, and diesel fuel. Nonane, decane, undecane, tridecane, tetradecane, and pentadecane were selected for evaluation of recovery to represent these ILR classes. The face-down heated can headspace sampling technique was compared to the previously reported, non-heated, paper cup headspace sampling technique. Mass recovery improvements of 50%–200% for five of the six target compounds in diesel fuel were achieved compared to the non-heated sampling method. The average relative standard deviation (reported as % RSD) between the replicate trials decreased from an average of 28% to 6% when using the heated can method. Ignitable liquids were spiked onto burned debris in a live burn exercise and sampled using the heated can and paper cup headspace sampling techniques. The heated sampling technique reported here, for the first time, demonstrates an effective extraction method that when coupled to a portable GC–MS instrument allows for a sampling and analysis protocol in the field in less than 30 min.  相似文献   

10.
目的为火场样品中痕量汽油残留物的检测建立一种简便、高灵敏度的检验方法和可靠的检验结果评判方法。方法用TenaxTA吸附管吸附富集火场样品中的汽油成分,然后用ATD—GC—MS法自动解吸和检测。通过模拟燃烧实验,探讨了检验结果的评判方法:根据样品的m/z(57+85)、m/z(91+105+119)、m/z(117+131)和m/z(128+142+156)四个质量色谱图与已知汽油作比较来对检验结果作评判。结果6组模拟燃烧实验中凡有汽油作助燃剂的样品.均检出汽油残留物成分。结论所建立的方法具有操作简便,检测灵敏度高,杂质干扰少,定性结论准确可靠等特点。可用于实际火场样品中痕量汽油残留物的检测。  相似文献   

11.
This study was undertaken to test the theory that there is a natural occurrence of petrol on the carpet or carpet mats of motor vehicles that would interfere with the potential determination of arson residues. Part of this study was also to determine what levels of background interference due to the carpet matrix are likely to be encountered in the general population of motor vehicles. The study was conducted in three parts.
  • 1.A persistence study was conducted to determine the evaporation and persistence of unleaded petrol on carpet. The results indicate that small volumes of petrol (less than 100 μl) are unlikely to be detected on carpet after a 24 h period. Larger volumes will be detected after this period, but will generally not be detectable after 1 week.
  • 2.A known history study was conducted by the insertion of carpet mats, for varying lengths of time, into the driver area of separate vehicles, with subsequent analysis for the presence of petrol. A ‘history’ sheet was completed by the occupants of the vehicles during the insertion periods to record the frequency of contact with petrol, and general usage of the vehicles. The results indicate that petrol will not normally be found on previously uncontaminated carpet mats after a 6-week period of use in a vehicle, however, the occupation and behaviour of the occupants can affect the types of compounds deposited onto the carpet.
  • 3.An unknown history study was conducted via the collection of carpet or carpet mat samples from vehicles with an unknown history, and subsequent analysis for the presence of petrol. Six of the 150 samples examined contained petrol. These results indicate that only a small proportion of motor vehicles will exhibit the presence of petrol on carpet or carpet mats, and then only as evaporated petrol.
All of the above findings increase the evidential value of finding significant volumes of fresh or slightly evaporated petrol on carpet products in motor vehicles.  相似文献   

12.
《Science & justice》2014,54(1):3-21
An LTQ-Orbitrap FTMS is a new (hybrid) mass spectrometric (MS) analyzer. It allows for the acquisition of full scan MSn (n-stage fragmentations, n = 1  n) spectra with the linear ion trap detector (LTQ) at high speed and/or with the Fourier Transform-detector (Orbitrap) with ultra high mass resolution (> 60,000 at m/z < 400 amu) and high mass accuracy (≤ 1 ppm with internal calibration). In addition it may be coupled with liquid chromatography (LC) with photo diode array (PDA) detection.Two methods for the forensic screening and confirmation of all common trace explosives in post-blast residues have been developed on this instrument using atmospheric pressure chemical ionization (APCI). In one run, the nitrogen-containing explosives are analyzed with the combination of “LC-(PDA)-APCI(−)-LTQ MS2/Orbitrap FTMS” (Method 1). In another run, peroxide explosives are analyzed with “LC-APCI(+)-LTQ MS2/Orbitrap FTMS” (Method 2).The performance of both methods has been validated according to procedures defined in the EU COMMISSION DECISION implementing Council Directive 96/23/EC concerning the performance of analytical methods and the interpretation of results (DC 2002/657/EC) and other standards (NEN 17025 and NEN 7777). The methods are highly selective due to the simultaneous utilization of the Orbitrap FTMS and LTQ MS2, both of which are highly selective detectors Tested explosive compounds can be detected in the molecular ion form by the Orbitrap analyzer with minimal mass interference in different matrices when using an extremely narrow mass tolerance detection window (≤ 2 ppm). The identification of a detected compound follows an identification point system. Experimental results show that almost all explosive compounds meet the confirmation criteria (minimum 4 points) required for the positive identification by the DC 2002/657/EC.  相似文献   

13.
Analyzing DNA from brass surfaces poses unique challenges that may result from DNA damage and/or PCR inhibition. To examine the relationship between the metal ions present in brass ammunition and the success of Short Tandem Repeat (STR) profiling, six recovery methods were tested to determine the identity and quantity of metal ions co-recovered during DNA sampling. In addition, DNA and metal ion solutions were created at varying concentrations to determine the threshold at which deleterious effects occur. The results of this study show that copper and zinc are recovered in the highest concentrations from both fired and unfired ammunition, but at substantially lower levels than previously published. Furthermore, most metal ions co-recovered with DNA were removed during DNA purification and complete STR profiles were generated when the concentrations of copper and zinc ions were less than 0.1 M and 0.03 M, respectively.  相似文献   

14.
Analysis of the C(0)- to C(2)-naphthalene compounds present in automotive gasoline using gas chromatography-mass spectrometry with selected ion monitoring (GC-MS (SIM)) and principal component analysis (PCA) was used to discriminate between different samples of gasoline. Phase one of this study explored the ability of this method to differentiate gasoline samples at different levels of evaporation. A total of 35 random samples of unevaporated gasoline, covering three different grades (regular unleaded, premium unleaded and lead replacement), were collected in Sydney, Australia and examined. The high-boiling C(0)- to C(2)-naphthalene compounds present in the gasoline were used to chemically fingerprint each sample at different levels of evaporation. Samples of 25, 50, 75 and 90% evaporated gasoline (by weight) were generated from the 35 samples of unevaporated gasoline. Analysis of the data by PCA followed by linear discriminant analysis (LDA) showed that the 35 samples formed 18 unique groups, irrespective of the level of evaporation. Good discrimination between gasoline samples that were collected on the same day was obtained. Phase two of this study examined the change in gasoline samples over time. The C(0)- to C(2)-naphthalene composition in 96 samples of gasoline collected from three service stations over a 16-week period was examined using the method described. In most cases, it was found that the C(0)- to C(2)-naphthalene profile changed from week to week, and from station to station. In a comparison of all 96 samples together it was found that the majority could be differentiated from one another. The application of the method to forensic casework is discussed.  相似文献   

15.
Blood detection and identification at crime scenes are crucial for harvesting forensic evidence. Unfortunately, most tests for the identification of blood are destructive and time consuming. We present a fast and nondestructive identification test for blood, using noncontact reflectance spectroscopy. We fitted reflectance spectra of 40 bloodstains and 35 nonbloodstains deposited on white cotton with spectroscopic features of the main compounds of blood. Each bloodstain was measured 30 times to account for aging effects. The outcome of the blood measurements was compared with the reflectance of blood-mimicking stains and various body fluids. We found that discrimination between blood and nonblood deposited on white cotton is possible with a specificity of 100% and a sensitivity of 98%. In conclusion, a goodness of fit between the sample's reflectance and the blood component fit may allow identification of blood at crime scenes by remote spectroscopy.  相似文献   

16.
A reversed phase gradient ultra performance liquid chromatography tandem mass spectrometry (UPLC/MS/MS) method has been developed for the analysis of smokeless powders. A total of 20 different components were separated by UPLC and detected by MS/MS in multiple reaction monitoring (MRM) mode. These compounds included diphenylamines, centralites, nitrotoluenes, nitroglycerin, and various phthalates. Simultaneous positive and negative electrospray ionization (ESI) was used along with negative atmospheric pressure chemical ionization (APCI) to detect all compounds in a single analysis. Analysis times were under 8 min with a gradient of 10–73% organic at a flow rate of 0.500 mL/min. With this method, ultraviolet and MRM limits of detection ranging from 0.08 to 2.6 ng and 0.4–64 ng injected were achieved. Commercially available smokeless powders were also extracted with methylene chloride and characterized using the developed UPLC/MS/MS method. The procedure permits the determination of compositional differences between different brands as well as lot‐to‐lot variations.  相似文献   

17.
This research examines the utility of patella outline shape for matching 3D scans of patellae to knee radiographs using elliptical Fourier analysis and subjective methods of human visual comparison of patellae across radiographs for identification purposes. Repeat radiographs were captured of cadaver's knees for visual comparison before patellae were extracted and skeletonized for quantitative comparisons. Quantitative methods provided significant narrowing down of the candidate pool to just a few potential matches (<5% of original sample), while the human analysts showed high capacity for correctly matching radiographs, irrespective of educational level (positive predictive value = 99.8%). The successful computerized matching based on a single quantified patella trait (outline shape) helps explain the potency achieved by subjective visual examination. This work adds to a growing body of studies demonstrating the value of single isolated infracranial bones for human identification via radiographic comparison.  相似文献   

18.
The characteristic that discriminates gasoline from other ignitable liquids is that it contains high‐octane blending components. This study elaborates on the idea that the presence of gasoline in fire debris samples should be based on the detection of known high‐octane blending components. The potential of the high‐octane blending component alkylate as a characteristic feature for gasoline detection and identification in fire debris samples is explored. We have devised characteristic features for the detection of alkylate and verified the presence of alkylate in a large collection of gasoline samples from petrol stations in the Netherlands. Alkylate was detected in the vast majority of the samples. It is demonstrated that alkylate can be detected in fire debris samples that contain traces of gasoline by means of routine GC‐MS methods. Detection of alkylate, alongside other gasoline blend components, results in a more solid foundation for gasoline detection and identification in fire debris samples.  相似文献   

19.
The purpose of this study was to evaluate the efficiency of the Cozart® RapiScan (CRS) drug test system for detecting opiates and cocaine in oral fluid. Oral fluid samples were collected using the Cozart® RapiScan collection system from 358 donors who were receiving treatment for their addiction and were monitored for drug misuse. A further 103 oral fluid samples were collected from volunteer donors who were not drug users. The samples were analyzed in the laboratory using the two-panel Cozart® RapiScan cartridge for opiates and cocaine and confirmed using gas chromatography–mass spectrometry (GC–MS). The samples were stored frozen at −20 °C until analysis by GC–MS. The overall accuracy of the CRS for both opiates and cocaine was 100%. Samples spiked at 50% above and below the cut-off consistently gave negative and positive results respectively. A total of 88 samples were positive for various opiates and 111 samples were positive for cocaine and/or its metabolites. The CRS for opiates and cocaine in oral fluid, using a cut-off of 30 ng/mL morphine or benzoylecgonine equivalents in neat oral fluid, had overall efficiencies of 98% and 99%, respectively, versus GC–MS. A series of potential adulterants of oral fluid were evaluated and shown not to alter the outcome of the test result.  相似文献   

20.
Analysis of impurities in seized MDMA tablets can be used to determine the synthesis method used and to identify links among exhibits. However, no standardized method exists to generate impurity profiles, limiting comparisons among different laboratories. This research investigated the effect of extraction procedure and gas chromatography temperature program on the resulting impurity profiles. Five exhibits were extracted using liquid–liquid extraction (LLE) and headspace solid‐phase microextraction (HS‐SPME), then analyzed using two different temperature programs. Profiles were statistically assessed using principal components analysis. While LLE was more reproducible, more compounds were extracted using HS‐SPME, thus providing more informative chemical profiles. The longer temperature program (53 min vs. 36 min) allowed greater discrimination of exhibits, due to improved precision as a result of an extended hold time (12 min). This research further highlights the need for standardized extraction and analysis procedures to allow comparison of chemical profiles generated in different laboratories.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号