首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 109 毫秒
1.
Abstract: Multiplex autosomal short tandem repeat (STR) genotyping enables researchers to obtain genetic information from ancient human samples. In this study, we tested newly developed AmpF?STR® MiniFiler? kit for autosomal STR analysis of ancient DNA (aDNA), using human femurs (n = 8) collected from medieval Korean tombs. After extracting aDNA from the bones, autosomal STR analyses were repeated for each sample using the AmpF?STR® MiniFiler? and Identifiler? kits. Whereas only 21.87% of larger‐sized loci profiles could be obtained with the Identifiler? kit, 75% of the same loci profiles were determined by MiniFiler? kit analysis. This very successful amplification of large‐sized STR markers from highly degraded aDNA suggests that the MiniFiler? kit could be a useful complement to conventional STR kit analysis of ancient samples.  相似文献   

2.
Abstract: Analysis of length polymorphism at short tandem repeat (STR) loci utilizing multiplex polymerase chain reaction (PCR) remains the primary method for genotyping forensic samples. The AmpF?STR® Identifiler® Plus PCR Amplification Kit is an improved version of the AmpF?STR® Identifiler® PCR Amplification Kit and amplifies the core CODIS loci: D3S1358, D5S818, D7S820, D8S1179, D13S317, D16S539, D18S51, D21S11, CSF1PO, FGA, TH01, TPOX, and vWA. Additional loci amplified in the multiplex reaction are the sex‐determinant, amelogenin, and two internationally accepted loci, D2S1338 and D19S433. While the primer sequences and dye configurations were unchanged, the AmpF?STR® Identifiler® Plus PCR Amplification Kit features an enhanced buffer formulation and an optimized PCR cycling protocol that increases sensitivity, provides better tolerance to PCR inhibitors, and improves performance on mixture samples. The AmpF?STR® Identifiler® Plus PCR Amplification Kit has been validated according to the FBI/National Standards and Scientific Working Group on DNA Analysis Methods (SWGDAM) guidelines. The validation results support the use of the AmpF?STR® Identifiler® Plus PCR Amplification Kit for human identity and parentage testing.  相似文献   

3.
Abstract: Forensic anthropologists routinely macerate human bone for the purposes of identity and trauma analysis, but the heat and chemical treatments used can destroy genetic evidence. As a follow‐up to a previous study on nuclear DNA recovery that used pig ribs, this study utilizes human skeletal remains treated with various bone maceration techniques for nuclear DNA amplification using the standard Combined DNA Index System (CODIS) markers. DNA was extracted from 18 samples of human lower leg bones subjected to nine chemical and heat maceration techniques. Genotyping was carried out using the AmpF?STR® COfiler® and AmpF?STR® Profiler Plus® ID kits. Results showed that heat treatments via microwave or Biz/Na2CO3 in sub‐boiling water efficiently macerate bone and produce amplifiable nuclear DNA for genetic analysis. Long‐term use of chemicals such as hydrogen peroxide is discouraged as it results in poor bone quality and has deleterious effects on DNA amplification.  相似文献   

4.
Significant efforts are being devoted to the development of methods enabling rapid generation of short tandem repeat (STR) profiles in order to reduce turnaround times for the delivery of human identification results from biological evidence. Some of the proposed solutions are still costly and low throughput. This study describes the optimization of an analytical process enabling the generation of complete STR profiles (single‐source or mixed profiles) for human identification in approximately 5 h. This accelerated process uses currently available reagents and standard laboratory equipment. It includes a 30‐min lysis step, a 27‐min DNA extraction using the Promega Maxwell®16 System, DNA quantification in <1 h using the Qiagen Investigator® Quantiplex HYres kit, fast amplification (<26 min) of the loci included in AmpF?STR® Identifiler®, and analysis of the profiles on the 3500‐series Genetic Analyzer. This combination of fast individual steps produces high‐quality profiling results and offers a cost‐effective alternative approach to rapid DNA analysis.  相似文献   

5.
Qiagen's Investigator? Quantiplex kit, a total human DNA quantitation kit, has a 200‐base pair internal control, fast cycling time, and scorpion molecules containing a covalently linked primer, probe, fluorophore, and quencher. The Investigator? Quantiplex kit was evaluated to investigate a value under which complete short tandem repeat (STR) failure was consistently obtained. Buccal swabs were extracted using the Qiagen QIAamp® DNA Blood Mini Kit, quantified with the Investigator? Quantiplex kit using a tested half‐volume reaction, amplified with the ABI AmpFlSTR® Identifiler kit, separated on the 3100Avant Genetic Analyzer, and data analyzed with GeneMapper® ID v.3.2. While undetected samples were unlikely to produce sufficient data for statistical calculations or CODIS upload (2.00 alleles and 0.82 complete loci on average), data may be useful for exclusionary purposes. Thus, the Investigator? Quantiplex kit may be useful for predicting STR success. These findings are comparable with previously reported data from the Quantifiler? Human kit.  相似文献   

6.
Since its introduction in 2002, the AmpF?STR® SEfiler™ kit has provided a highly discriminating DNA profiling option to German forensic laboratories by combining the widely used SGM Plus® Kit loci with the SE-33 locus required for the German DNA Database. Whilst proving successful on database samples, laboratories using the SEfiler™ kit have reported the need for chemistry better able to handle the ever-increasing number of casework samples.The new AmpF?STR® SEfiler Plus™ kit contains the same loci and primer sequences as the SEfiler™ kit but uses improved synthesis and purification processes to minimize the presence of dye-labeled artifacts. Other improvements include modified PCR cycling conditions for enhanced sensitivity and a new buffer formulation that improves performance with inhibited samples when compared to the original SEfiler™ kit.Validation studies demonstrating the effectiveness of the multiplex are presented with emphasis on the models of inhibition and casework samples.  相似文献   

7.
European forensic laboratories are replacing the STR multiplex kits with the new generation 16/17 STR kits. This study examines the influence of the new generation kits and the new Applied Biosystems 3500xL Genetic Analyzer on the designation of long D2S1338 and D19S433 off‐ladder alleles. Different allele calls were obtained using the new NGM? (Applied Biosystems) and PowerPlex® ESI? (Promega) kits compared with AmpF?STR® SGM Plus? kit (Applied Biosystems). Sequence analysis was used to determine accurate allele designation. The new multiplex kits and the 3500xL Genetic Analyzer improved accuracy of long allele designations. DNA databases worldwide include countless profiles obtained by previous kits. Discrepancies between the new and former technologies may cause failure to detect hits. Discordance is expected due to primer sequence differences between various kits. An additional discordance, occurring in long alleles, independent of primer sequence is reported in this study.  相似文献   

8.
In this study, DNA was extracted using an AutoMate Express? and an EZ1 Advanced XL from liquid blood, fresh and aged bloodstains, and fresh and aged semen stains. Extracted DNA was quantified by real‐time PCR using the D17Z1 locus. Short tandem repeat typing was performed using an AmpF?STR® Identifiler kit. The yields of DNA obtained by the AutoMate Express? were higher from fresh bloodstains and fresh semen stains, almost the same from aged bloodstains and aged semen stains, but slightly lower from liquid blood compared with those obtained by the EZ1 Advanced XL. The addition of dithiothreitol or the use of PrepFiler? lysis buffer improved the EZ1 Advanced XL results from fresh bloodstains, but not for liquid blood and aged bloodstains. Our results demonstrated that the PrepFiler? lysis buffer is the main contributor to the higher DNA yields of the AutoM ate Express? for fresh bloodstains.  相似文献   

9.
10.
Abstract: The Quantifiler® Duo DNA Quantification kit enables simultaneous quantification of human DNA and human male DNA as well as detection of inhibitors of PCR in a single real-time PCR well. Pooled human male genomic DNA is used to generate standard curves for both human (ribonuclease P RNA component H1) and human male (sex determining region Y) specific targets. A shift in the cycle threshold (CT) values for the internal positive control monitors the presence of PCR inhibitors in a sample. The assay is human specific and exhibits a high dynamic range from 0.023 to 50 ng/μL. In addition, the multiplex assay can detect as little as 25 pg/μL of human male DNA in the presence of a 1000-fold excess of human female DNA. The multiplex assay provides assessment of the DNA extract and guidance for the selection of the appropriate AmpFℓSTR® Amplification Kit to obtain interpretable short tandem repeat profiles.  相似文献   

11.
Abstract: The AmpF?STR® MiniFilerTM PCR Amplification Kit is designed to genotype degraded and/or inhibited DNA samples when the AmpF?STR® IdentifilerTM PCR Amplification Kit is incapable of generating a complete genetic profile. Validation experiments, following the SWGDAM guidelines, were designed to evaluate the performance of MiniFiler. Data obtained demonstrated that MiniFiler, when used in conjunction with Identifiler, provided an increased ability to obtain genetic profiles from challenged samples. The optimum template range was found to be between 0.2 and 0.6 ng, with 0.3 ng yielding the best results. Full concordance was achieved between the MiniFiler kit and Identifiler kit except in a single case of a null allele at locus D21S11. Numerous instances of severe heterozygous peak imbalance (<50%) were observed in single source samples amplified within the optimum range of input DNA suggesting that caution be taken when attempting to deduce component genotypes in a mixture.  相似文献   

12.
Seventeen Y-STR loci included in the AmpF?STR® Yfiler™ PCR Amplification kit were typed in a population sample of 208 males from Upper (South) Egypt. Of 204 observed haplotypes, 200 were unique (96.6%) and 4 were found twice each. The 17 loci gave a discriminating power of 0.9998. DYS458 showed the highest diversity as a single-locus marker (h = 0.868) along with a high frequency of microvariants and new alleles (22% of the sample). Other loci revealed duplicated and null alleles. Comparative analysis with Y-STR datasets of relevant populations and submission of the haplotypes to the Y-STR Haplotype Reference Database (YHRD) were undertaken.  相似文献   

13.
Abstract: The AmpF?STR® Identifiler® Direct PCR Amplification Kit is a new short tandem repeat multiplex assay optimized to allow the direct amplification of single‐source blood and buccal samples on FTA® card without the need for sample purification and quantification. This multiplex assay has been validated according to the FBI/National Standards and SWGDAM guidelines. Validation results revealed that slight variations in primer concentration, master mix component concentration, and thermal cycling parameters did not affect the performance of the chemistry. The assay’s sensitivity was demonstrated by amplifying known amounts of white blood cells spotted onto FTA® cards, and the assay’s specificity was verified by establishing minimal cross‐reactivity with nonhuman DNA. No effect on the age of the sample stored on the FTA® substrate was observed and full concordance was established in the population study. These findings of the validation study support the use of the Identifiler® Direct Kit for forensic standards and database samples genotyping.  相似文献   

14.
Validation of the AmpF?STR® SEfiler Plus™ PCR Amplification kit with 29 and 30 PCR cycles for forensic STR analysis demonstrated that the kit had fewer artefacts than the AmpF?STR® SGM Plus™ kit (28 PCR cycles). The SEfiler Plus kit was more sensitive and devoid of colour artefacts, but showed more stutters, drop-ins, drop-outs and allelic imbalances.  相似文献   

15.
A 96-channel microfabricated capillary array electrophoresis (muCAE) device was evaluated for forensic short tandem repeat (STR) typing using PowerPlex 16 and AmpFlSTR Profiler Plus multiplex PCR systems. The high-throughput muCAE system produced high-speed <30-min parallel sample separations with single-base resolution. Forty-eight previously analyzed single-source samples were accurately typed, as confirmed on an ABI Prism 310 and/or the Hitachi FMBIO II. Minor alleles in 3:1 mixture samples containing female and male DNA were reliably typed as well. The instrument produced full profiles from sample DNA down to 0.17 ng, a threshold similar to that found for the ABI 310. Seventeen nonprobative samples from various evidentiary biological stains were also correctly typed. The successful application of the muCAE device to actual forensic STR typing samples is a significant step toward the development of a completely integrated STR analysis microdevice.  相似文献   

16.
About 120,000 reference samples are analyzed each year in the Forensic Laboratory of Lyon. A total of 1640 positive control experiments used to validate and optimize the analytical method in the routine process were submitted to a multivariate exploratory data analysis approach with the aim of better understanding the underlying sources of variability. The peak heights of the 16 genetic markers targeted by the AmpF?STR® Identifiler® STR kit were used as variables of interest. Six different 3130xl genetic analyzers located in the same controlled environment were involved. Two major sources of variability were found: (i) the DNA load of the sample modulates all peak heights in a similar way so that the 16 markers are highly correlated, (ii) the genetic analyzer used with a locus‐specific response for peak height and a better sensitivity for the most recently acquired. Three markers (FGA, D3S1358, and D13S317) were found to be of special interest to predict the success rate observed in the routine process.  相似文献   

17.
The allele frequencies of eight MiniFiler™ loci have been analyzed in 101 Japanese individuals living in Kanagawa with informed consent by means of ABI 310 Genetic Analyzer. A total of 7 alleles for D13S317, 8 alleles for D7S820, 11 alleles for D2S1338, 11 alleles for D21S11, 5 alleles for D16S539, 14 alleles for D18S51, 8 alleles for CSF1PO, and 13 alleles for FGA were observed. The polymorphic profiles of these MiniFiler™ loci in the present study were essentially the same as those obtained by using the AmpFlSTR® Identifiler® PCR Amplification kit. The combined matching probability of eight MiniFiler™ loci and cumulative probability of paternity exclusion were estimated as 1.97 × 10−10 and 0.9996, respectively. The MiniFiler™ kit was useful for individual identification in forensic analysis.  相似文献   

18.
We were presented with the STR (short tandem repeat) profiles from two separate paternity trios. Each trio consisted of a mother, an alleged father, and products of conception (POC) that contained a hydatidiform mole but no visible fetus. In both cases , antecedent pregnancies had followed alleged sexual assaults. Mole classification and pathogenesis are described in order to explain the analyses and statistical reasoning used in each case. One mole exhibited several loci with two different paternal alleles, indicating it was a dispermic (heterozygous) mole. Maternal decidua contaminated the POC, preventing the identification of paternal obligate alleles (POAs) at some loci. The other mole exhibited only one paternal allele/locus at all loci and no maternal alleles, indicating it was a diandric and diploid (homozygous) mole. In each case, traditional calculations were used to determine paternity indices (PIs) at loci that exhibited one paternal allele/locus. PIs at mole loci with two different paternal alleles/locus were calculated from formulas first used for child chimeras that are always dispermic. Combined paternity indices in both mole cases strongly supported the paternity of each suspect.  相似文献   

19.
In this study, gestational trophoblastic disease (GTD) was observed by short tandem repeat (STR) typing from the aborted tissues in a sexual assault case. By histological screening, the fetal tissue could not be distinguished from the maternal tissue in this case. Therefore, five specimens were collected randomly from the aborted tissues for DNA analysis. STR typing was performed by the commercial ABI Identifiler kit. The results showed that three specimens were of the maternal origin, one was a mixture of the mother and male fetus, and the other one was of male fetal origin with partial triploid. Three alleles were identified in each locus of D8S1179, D7S820 and VWA for the fetal specimen. For these three alleles, one matched the maternal origin and the others matched the putative paternal origin (suspect). Analysis of the Y-STR by using the commercial ABI Y-Filer kit, the fetal types matched the types of the suspect. We reported the case of partial mole on forensic evidence and gave the valuable information from its identification.  相似文献   

20.
Abstract: Three sampled populations of unrelated males—African American, Caucasian, and Hispanic, all from Texas—were typed for 16 Y short tandem repeat (STR) markers using the AmpFlSTR® YfilerTM kit. These samples also were typed previously for the 13 core CODIS autosomal STR loci. Most of the 16 marker haplotypes (2478 out of 2551 distinct haplotypes) were observed only once in the data sets. Haplotype diversities were 99.88%, 99.89%, and 99.87% for the African American, Caucasian, and Hispanic sample populations, respectively. FST values were very small when a haplotype comprised 10–16 markers. This suggests that inclusion of substructure correction is not required. However, haplotypes consisting of fewer loci may require the inclusion of FST corrections. The testing of independence of autosomal and Y STRs supports the proposition that the frequencies of autosomal and Y STR profiles can be combined using the product rule.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号