首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 625 毫秒
1.
The elemental objects of the research study are: determination of time periods corresponding to gunshot residue particles (GSR) deposition after the shot from selected pistols and a revolver, and evaluation of the deposited particles number. For several shooting experiments were used a pistol CZ model 85, caliber 9 mm Luger with common ammunition 9 mm Luger FMJ Sellier & Bellot, a pistol CZ model 70, caliber 7.65 mm Browning (32 ACP) with common 7.65 mm Browning FMJ Sellier & Bellot ammunition and a revolver S&W Modell 60, barell length 2-1/8', cal. .38 Special with common Sellier&Bellot (FMJ) ammunition. The results of the study have indicated the behavior of GSR particles deposited after a single discharge. The overall time interval of GSR particles deposition and the number of deposited particles with the above mentioned arms and ammunition were established. The results can potentially be used for clarifying the situation at crime scenes and for subsequent interpretation of GSR evidential value in caseworks.  相似文献   

2.
3.
Abstract:  In order to assess whether or not the class and individual characteristics of a firearm change over time, five different makes of Turkish self-loading pistol were tested and were each fired a large number of times. The class and individual characteristics were identified for each pistol and the first fired cartridge case was compared with the subsequent consecutive 250th fired cases for each pistol. It was found that there were slight changes in some of the individual and class characteristics; however, this was not statistically significant and did not affect the ability of the firearms examiner to match the first fired case to the last fired case for each firearm tested.  相似文献   

4.
Several series of experiments were performed to study the distribution of GSR particles in seven directions in the surroundings of shooting firearm (pistol CZ 85 caliber 9 mm Luger). External and internal conditions and two different primer types were used for the shooting experiments. The results showed that maximum number of GSR particles could be found in the right front quadrant at a distance of 2–4 m with respect to the shooting firearm position and shooting direction. GSR particles were even found in distance 10 m from shooting firearm. A significant influence of climatic conditions on GSR distribution was confirmed.  相似文献   

5.
Several different methods can be employed to test for gunshot residue (GSR) on a decedent's hands, including scanning electron microscopy with energy dispersive x-ray (SEM/EDX) and inductive coupled plasma-atomic emission spectrometry (ICP-AES). In part I of this 2-part series, GSR results performed by SEM/EDX in undisputed cases of suicidal handgun wounds were studied. In part II, the same population was studied, deceased persons with undisputed suicidal handgun wounds, but GSR testing was performed using ICP-AES. A total of 102 cases were studied and analyzed for caliber of weapon, proximity of wound, and the results of the GSR testing. This study found that 50% of cases where the deceased was known to have fired a handgun immediately prior to death had positive GSR results by ICP/AES, which did not differ from the results of GSR testing by SEM/EDX. Since only 50% of cases where the person is known to have fired a weapon were positive for GSR by either method, this test should not be relied upon to determine whether someone has discharged a firearm and is not useful as a determining factor of whether or not a wound is self-inflicted or non-self-inflicted. While a positive GSR result may be of use, a negative result is not helpful in the medical examiner setting as a negative result indicates that either a person fired a weapon prior to death or a person did not fire a weapon prior to death.  相似文献   

6.
毛发枪弹损伤的环境扫描电镜研究   总被引:1,自引:0,他引:1  
目的探讨毛发枪弹损伤微观形态与射击距离之间的关系。方法应用环境扫描电镜/能谱仪对64式手枪在0~200cm范围内射击造成的毛发损伤及附着物进行形态和成分分析。结果0~30cm射击,毛发表面粘附有大量密集分布的球形射击残留物颗粒,鳞片有严重斑纹状损伤和崩裂缺损;30~60cm射击,毛发表面粘附有较多散在分布的球形射击残留物颗粒,鳞片有轻微斑纹状损伤和崩裂缺损;100cm距离射击,毛发表面粘附有少数个别射击残留物颗粒,鳞片无斑纹状损伤;200cm距离射击,毛发表面无射击残留物。毛发枪弹射击断裂形态差异较大,大体分为剪切断裂和牵拉断裂两种类型,与射击距离无明显相关性。结论毛发表面粘附的大量球形射击残留物颗粒及其造成的鳞片斑纹状损伤对于法医学鉴定贴近距离射击((30cm)具有重要的实用价值。  相似文献   

7.
A statistical investigation of the relationship between firing range and the amount and distribution of gunshot residue (GSR), used automated image analysis (IA) to quantify GSR deposit resulting from firings into pig skin, from distances ranging between contact and 45 cm. Overall, for a Ruger .22 semi-automatic rifle using CCI solid point, high velocity ammunition, the total area of GSR deposit on the skin sections decreased in a non-linear fashion with firing range. More specifically there were significant differences in the amount of GSR deposited from shots fired at contact compared with shots fired from distances between 2.5 and 45 cm; and between shots fired from a distance of 20 cm or less, with shots fired at a distance of 30 cm or more. In addition, GSR particles were heavily concentrated in the wound tract only for contact and close range shots at 2.5 cm, while the particle distribution was more uniform between the wound tract and the skin surfaces for shots fired from distances greater than 2.5 cm. Consequently, for future scientific investigations of gunshot fatalities, once standards have been established for the weapon and ammunition type in question, image analysis quantification of GSR deposited in and around the gunshot wound may be capable of providing a reliable, statistical basis for estimating firing range.  相似文献   

8.
A statistical investigation of the relationship between firing range and the amount and distribution of gunshot residue (GSR), used automated image analysis (IA) to quantify GSR deposit resulting from firings into pig skin, from distances ranging between contact and 45 cm. Overall, for a Ruger .22 semi-automatic rifle using CCI solid point, high velocity ammunition, the total area of GSR deposit on the skin sections decreased in a non-linear fashion with firing range. More specifically there were significant differences in the amount of GSR deposited from shots fired at contact compared with shots fired from distances between 2.5 and 45 cm; and between shots fired from a distance of 20 cm or less, with shots fired at a distance of 30 cm or more. In addition, GSR particles were heavily concentrated in the wound tract only for contact and close range shots at 2.5 cm, while the particle distribution was more uniform between the wound tract and the skin surfaces for shots fired from distances greater than 2.5 cm. Consequently, for future scientific investigations of gunshot fatalities, once standards have been established for the weapon and ammunition type in question, image analysis quantification of GSR deposited in and around the gunshot wound may be capable of providing a reliable, statistical basis for estimating firing range.  相似文献   

9.
Research into the deposition patterns of primer gunshot residue (GSR) beyond a primary target was previously nonexistent. This study aimed to determine the deposition patterns of GSR once a bullet passed through an initial target and continued on its path into additional targets. Multiple repetitions were performed to assess the GSR deposition patterns after a bullet was shot through a closed window into either a dummy or a wall within an enclosed room. Samples were taken from both the primary and secondary target holes as well as from nontarget areas. Significant amounts of GSR were found on all samples. The results show that GSR continues to be deposited along the path of the bullet after passing through a primary glass target. These findings reiterate the lack of probative value in collecting GSR samples from gunshot victims even if they are in an enclosed area separate from the shooter.  相似文献   

10.
The susceptibility for recreational shooters to transfer gunshot residue (GSR) to both the interior and exterior of a vehicle is investigated. A comprehensive sampling protocol was used to assess the most likely areas of GSR transfer from recreational shooter contact, such as the steering wheel and the area, the firearms were stored (the trunk). Up to 315 characteristic GSR, particles were found in several locations throughout the interior of a vehicle. As many as 876 characteristic particles were found throughout a single vehicle. The data indicate that vehicles frequently occupied by firearms users are a potential source for inadvertent transfer of GSR to persons unrelated to firearm activity. In criminal cases where vehicles have been used, such transfer processes for GSR need to be considered within the context of any case interpretation. The implications for subsequent contamination and transfer processes from such vehicles require further investigation.  相似文献   

11.
An automated image analysis (IA) technique has been developed to obtain a measure of the amount (i.e. number and area) of gunshot residue (GSR) particles within and around a gunshot wound. Sample preparation and IA procedures were standardised to improve the reproducibility of the IA measurements of GSR. Measurements of GSR from test firings into goat hide were enhanced by staining the barium and lead components present on the skin sections with Alizarin Red S. The amount of GSR detected on the stained skin sections was compared with backscatter electron micrographs of the same sections. The differences were deemed to be insignificant when the variability in the repeated test firings were taken into consideration. Preliminary results indicated that the decreasing relationship between firing range and the amount of GSR deposited was non-linear, and that for firing ranges of up to 20 cm the amount of GSR deposited from repeated shots fired from the same distance was highly variable.  相似文献   

12.
Various 9‐mm ammunitions (A1, A4, A5, ST, GS, GSb, P.E.P., SeCa, HP, PTP/s, VM, McVG, DM41, PTP, SX2, PT, and MEN frangible) were tested regarding their velocity, energy, angle of impact, and potential wound channel after penetrating a car window at 30° and 90°. Test materials were gelatine, soap, and pig cadavers. The velocities of the projectiles were between c. 288 and 430 m/ses, the energy spread between 394 and 564 J. Handgun bullets fired through vehicular side window glass lose substantial energy reducing the effectiveness of the ammunition. This effect is greater when fired at an angle of 30° compared to 90°. At a shooting angle of 90°, none of the different projectiles showed remarkable differences considering its wound ballistic features. Accuracy is maintained at a 90° angle but seriously impaired at 30°. None of the examined ammunition complied with the demanded wound channel effectiveness of 30–60 J/cm.  相似文献   

13.
A study was conducted to assess the influence of a possible contamination of the victim's clothing by gunpowder residue on the estimation of shooting distance. The study was focused on the scenario in which the contamination might be caused by the surface on which the shot victim could fall. Contamination of two types of textile was examined after contact with two types of surfaces. One round was fired above those surfaces (the line of firing parallel to the surface) prior to the contact. It was found that few gunpowder residue particles could be transferred to the clothing. These findings should be taken into account when interpreting results for shooting distance estimation in cases when a minute quantity of gunpowder residue particles is found around the bullet entrance hole.  相似文献   

14.
An automated image analysis (IA) technique has been developed to obtain a measure of the amount (i.e. number and area) of gunshot residue (GSR) particles within and around a gunshot wound. Sample preparation and IA procedures were standardised to improve the reproducibility of the IA measurements of GSR. Measurements of GSR from test firings into goat hide were enhanced by staining the barium and lead components present on the skin sections with Alizarin Red S. The amount of GSR detected on the stained skin sections was compared with backscatter electron micrographs of the same sections. The differences were deemed to be insignificant when the variability in the repeated test firings were taken into consideration. Preliminary results indicated that the decreasing relationship between firing range and the amount of GSR deposited was non-linear, and that for firing ranges of up to 20 cm the amount of GSR deposited from repeated shots fired from the same distance was highly variable.  相似文献   

15.
Abstract:  Automated scanning electron microscopy with energy dispersive spectroscopy has been used to analyze airbag residue particles. Analysis of airbag residue from some passenger side airbags revealed some residue particles which are consistent with gunshot residue (GSR) samples. The source of these particles was determined to be percussion primers used to initiate the chemical reaction for deployment. This article identifies some vehicles which contain this type of airbag and demonstrates the types of particles which could be misidentified as being GSR. The low numbers of GSR particles in among the large particle populations of zirconium and/or copper–cobalt particles, which are clearly airbag residue, allow the trained analysts to distinguish the correct source of this residue. Particles containing high aluminum levels, elevated levels of allowable elements in GSR particles, or the presence of elements that are rare in GSR particles stand out as indications that the particles are not GSR in origin. This study serves as a guide to analysts who perform particle analysis in forensic investigations.  相似文献   

16.
Due to possible secondary transfer of gunshot residue (GSR) onto a suspect in police custody prior to sampling, a baseline must be created for the amount of GSR present. With an increase of “lead free” ammunition, testing for both gunpowder and primer GSR is relevant. Seventy samples were collected using carbon‐coated adhesive stubs from four Pittsburgh Police Stations and vehicles to investigate these locations as sources of secondary GSR contamination. These seventy samples were analyzed for primer GSR using scanning electron microscopy‐energy‐dispersive X‐ray spectrometry. One primer GSR particle was detected; no sample was classified as positive for primer GSR. These same samples were then analyzed for gunpowder GSR using liquid chromatography coupled to tandem mass spectrometry to test for akardite II, ethylcentralite, diphenylamine, N‐nitrosodiphenylamine, 2‐nitrodiphenylamine, and 4‐nitrodiphenylamine. Ethylcentralite was quantifiable in two test samples. These results suggest there is a negligible potential for secondary transfer of primer and gunpowder GSR.  相似文献   

17.
A 20-year-old male was found on the passenger side of a small car after a collision with a semi-trailer truck. Postmortem blood, collected from the chest cavity, and vitreous humor samples were collected following harvesting of the heart and bones. Gas chromatographic analysis revealed a blood ethanol concentration of 0.32 g/dL and a vitreous humor ethanol concentration of 0.09 g/dL. The stomach was intact and full of fluid and food, but its contents were not collected. Possible explanations for the large difference between the two results include diffusion of ethanol from the stomach into the chest cavity, contamination of the blood sample prior to collection, and ingestion of a large quantity of ethanol shortly before death. This case demonstrates the importance of proper quality assurance procedures in collecting postmortem specimens and of collecting a vitreous humor sample for ethanol analysis in postmortem toxicology cases.  相似文献   

18.
A severe traffic accident occurred on the German autobahn. According to eye witnesses, the car had changed from the left to the right lane at 160 km/h before crashing into a thicket at full speed. In the car, a sports pistol was found in the footwell of the driver's side. The emergency doctor who performed the external examination of the victim's body found a gunshot wound in the region of the driver's right lower jaw. As the prosecutor released the body without further examination, the family of the suicide asked for an autopsy, which demonstrated a lethal suicidal gunshot to the head; toxicological tests proved a previous consumption of cocaine.  相似文献   

19.
In this study, chemical composition and morphology of gunshot residue (GSR) of 9 × 19 mm Parabellum‐type MKE (Turkey)‐brand ammunition were analyzed by scanning electron microscope and energy dispersive X‐ray spectrometer. GSR samples were collected by “swab” technique from the shooter's right hand immediately after shooting. According to general principles of thermodynamics, it is likely that the structures will have a more regular (homogeneous) spherical form to minimize their surface area due to very high temperatures and pressures that occur during explosion. Studied samples were collected under the same conditions with the same original ammunition, from the same firearm and a single shooter. This is because many other variables may affect size, structure, and composition in addition to the concentrations of elements of the structure. Results indicated that the chemical compositions are effective in the formation of GSR morphological structures.  相似文献   

20.
Abstract: Firearms identification is based on the fundamental principle that it is impossible to manufacture two identical items at the microscopic level. As firearm manufacturing technologies and quality assurance are improving, it is necessary to continually challenge this principle. In this study, two different makes of 7.65 mm Browning/.32 Automatic caliber self‐loading pistols of Turkish manufacture were selected and examined. Ten pistols with consecutive serial numbers were examined and each fired 10 times. The fired cartridge cases were recovered for comparison purposes. It was found that for each make of pistol, the individual characteristics within the firing pin impression, ejector, and breech face marks of all 10 pistols were found to be significantly different.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号