The purpose of this study was to determine the performance characteristics of the Cozart Amphetamine Microplate EIA for detecting amphetamine in oral fluid. Oral fluid samples were collected using the Cozart RapiScan Collection System from 135 volunteer donors from drug treatment clinics. A further 35 oral fluid samples were collected from volunteer donors who were not drug users. The samples were analyzed in the laboratory using the Cozart Amphetamine Microplate EIA and confirmed using gas chromatography-mass spectrometry (GC-MS). The samples were stored frozen until analysis by GC-MS. The intra-assay precision for the Cozart Amphetamine Microplate EIA for amphetamine in oral fluid over forty assays was 2.74-7.1% CV (within assay) and 3.4-7.0% CV (within day). A total of 78 samples were positive for various amphetamines and related designer drugs. The Cozart Amphetamine Microplate EIA, using a cutoff of 45 ng/ml amphetamine equivalents in neat oral fluid, had a sensitivity of 91.7+/-3.3% and a specificity of 95.9+/-1.9% versus GC-MS using a cutoff of 30 ng/ml. A series of potential adulterants of oral fluid were evaluated and shown not to alter the outcome of the test result.  相似文献   

2.
The purpose of these studies was to evaluate the performance characteristics of the Cozart Microplate Enzyme Immunoassay (EIA) for the determination of methadone in oral fluid from patients in a drug misuse treatment program. Oral fluid specimens were collected using the Cozart RapiScan Collection system from 198 donors who were receiving treatment for their addiction and were monitored for drug misuse. Oral fluid specimens were also collected from forty volunteer donors who were not drug users. The specimens were analyzed in the laboratory by EIA and then analysed for methadone and its main metabolite EDDP by gas chromatography-mass spectrometry (GC-MS). A total of 103 samples were confirmed positive for methadone. The Cozart Microplate EIA for d-Methadone in oral fluid using a cutoff of 30 ng/mL in diluted oral fluid had a sensitivity of 91.3% +/- 2.8% and a specificity of 100% +/- 1.0% vs. GC-MS.  相似文献   

3.
The purpose of this study was to evaluate the efficiency of the Cozart RapiScan (CRS) drug test system for detecting opiates and cocaine in oral fluid. Oral fluid samples were collected using the Cozart RapiScan collection system from 358 donors who were receiving treatment for their addiction and were monitored for drug misuse. A further 103 oral fluid samples were collected from volunteer donors who were not drug users. The samples were analyzed in the laboratory using the two-panel Cozart RapiScan cartridge for opiates and cocaine and confirmed using gas chromatography-mass spectrometry (GC-MS). The samples were stored frozen at -20 degrees C until analysis by GC-MS. The overall accuracy of the CRS for both opiates and cocaine was 100%. Samples spiked at 50% above and below the cut-off consistently gave negative and positive results respectively. A total of 88 samples were positive for various opiates and 111 samples were positive for cocaine and/or its metabolites. The CRS for opiates and cocaine in oral fluid, using a cut-off of 30 ng/mL morphine or benzoylecgonine equivalents in neat oral fluid, had overall efficiencies of 98% and 99%, respectively, versus GC-MS. A series of potential adulterants of oral fluid were evaluated and shown not to alter the outcome of the test result.  相似文献   

4.
The purpose of this study was to evaluate the efficiency of the Cozart® RapiScan (CRS) drug test system for detecting opiates and cocaine in oral fluid. Oral fluid samples were collected using the Cozart® RapiScan collection system from 358 donors who were receiving treatment for their addiction and were monitored for drug misuse. A further 103 oral fluid samples were collected from volunteer donors who were not drug users. The samples were analyzed in the laboratory using the two-panel Cozart® RapiScan cartridge for opiates and cocaine and confirmed using gas chromatography–mass spectrometry (GC–MS). The samples were stored frozen at −20 °C until analysis by GC–MS. The overall accuracy of the CRS for both opiates and cocaine was 100%. Samples spiked at 50% above and below the cut-off consistently gave negative and positive results respectively. A total of 88 samples were positive for various opiates and 111 samples were positive for cocaine and/or its metabolites. The CRS for opiates and cocaine in oral fluid, using a cut-off of 30 ng/mL morphine or benzoylecgonine equivalents in neat oral fluid, had overall efficiencies of 98% and 99%, respectively, versus GC–MS. A series of potential adulterants of oral fluid were evaluated and shown not to alter the outcome of the test result.  相似文献   

5.
The use of amphetamine and 'ecstasy' (MDMA) has increased exponentially in many European countries since the late nineties, leading to a rapid growth in the number of clinical and forensic analyses. Therefore, a rapid screening procedure for these substances in biological specimens has become an important part of routine toxicological analysis in forensic laboratories. The objective of this study was to evaluate the Cozart amphetamine enzyme-linked immunosorbent assay (ELISA) for the screening of plasma samples and oral fluid samples (collected with the Intercept device). Authentic plasma samples from drivers (n=360) were screened, using an 1:5-fold dilution. True positive, true negative, false positive and false negative results were determined relative to the in-house routine GC-MS analysis. Samples consisted of 144 amphetamine-only positives, 141MDMA/MDA-only positives, and 74 negatives when using the limit of quantitation as the cut-off level for confirmation (10 ng/mL). Using these results, receiver operating characteristic (ROC) curves were generated and optimal cut-off values for the screening assay were calculated. Analysis showed that the ELISA is able to predict the presence of either amphetamine or *MDMA/MDA (*MDMA as its metabolite MDA) in plasma samples with 98.3% sensitivity and 100% specificity at a cut-off value of 66.5 ng/mL d-amphetamine equivalents. A similar analysis was conducted on 216 oral fluid specimens collected from a controlled double blind study. Subjects received placebo or a high (100 mg) or low (75 mg) dose of MDMA. Oral fluid samples were collected at 1.5 and 5.5h after administration. Combined results of the analysis of the high and low dose oral fluid samples indicated a screening cut-off of 51 ng/mL d-amphetamine equivalents with both a sensitivity and specificity of 98.6% (using a LC-MS/MS confirmation cut-off of 10 ng/mL). In conclusion, these data indicate that the Cozart AMP EIA plates constitute a fast and accurate screening technique for the identification of amphetamine and MDMA/MDA positive plasma samples and oral fluid specimens (collected with Intercept. It should be emphasized that method validation should be performed for each type of biological matrix.  相似文献   

6.
Testing for drugs in oral fluid is a convenient procedure for determining recent drug use. A number of issues are still to be resolved and this paper investigates the effects of storage systems on drug stability and recovery using three different collection devices supplied by Cozart, Immunalysis and Microgenics (third party). Drugs were analysed using a range of immunoassay systems followed by MS confirmation and quantitation. The reproducibility of the weight of specimen collected was excellent (CV<10%) for the three collection devices tested. Of the three systems studied, only the Cozart product gave acceptable recovery of THC from drug-spiked oral fluid. A combination of Cozart, Immunalysis and Diagnostix immunoassays with the Cozart collection system gave the most sensitive and discriminating screening assays for the drugs studied, namely THC, benzodiazepines, methamphetamine and morphine. Storage at either 5 degrees C or room temperature had no significant effect on drug recoveries.  相似文献   

7.
A study was performed to acquire urine, serum and oral fluid samples in cases of suspected driving under the influence of drugs of abuse. Oral fluid was collected using a novel sampling/testing device (Dr?ger DrugTest System). The aim of the study was to evaluate oral fluid and urine as a predictor of blood samples positive for drugs and impairment symptoms. Analysis for cannabinoids, amphetamine and its derivatives, opiates and cocaine was performed in urine using the Mahsan Kombi/DOA4-test, in serum using immunoassay and gas chromatography-mass spectrometry (GC-MS) confirmation and in oral fluid by GC-MS. Police and medical officer observations of impairment symptoms were rated and evaluated using a threshold value for the classification of driving inability. Accuracy in correlating drug detection in oral fluid and serum were >90% for all substances and also >90% in urine and serum except for THC (71.0%). Of the cases with oral fluid positive for any drug 97.1% of corresponding serum samples were also positive for at least one drug; of drug-positive urine samples this were only 82.4%. In 119 of 146 cases, impairment symptoms above threshold were observed (81.5%). Of the cases with drugs detected in serum, 19.1% appeared not impaired which were the same with drug-positive oral fluid while more persons with drug-positive urine samples appeared uninfluenced (32.7%). The data demonstrate that oral fluid is superior to urine in correlating with serum analytical data and impairment symptoms of drivers under the influence of drugs of abuse.  相似文献   

8.
Methamphetamine (MA) is the most commonly abused drug in Korea, followed by cannabis. Traditionally, MA analysis is carried out on both urine and hair samples and cannabis analysis in urine samples only. Despite the fact that oral fluid has become increasingly popular as an alternative specimen in the field of driving under the influence of drugs (DUID) and work place drug testing, its application has not been expanded to drug analysis in Korea. Oral fluid is easy to collect and handle and can provide an indication of recent drug abuse.In this study, we present an analytical method using GC–MS to determine tetrahydrocannabinol (THC) and its main metabolite 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid (THC-COOH) in oral fluid. The validated method was applied to oral fluid samples collected from drug abuse suspects and the results were compared with those in urine. The stability of THC and THC-COOH in oral fluid stored in different containers was also investigated.Oral fluid specimens from 12 drug abuse suspects, submitted by the police, were collected by direct expectoration. The samples were screened with microplate ELISA. For confirmation they were extracted using automated SPE with mixed-mode cation exchange cartridge, derivatized and analyzed by GC-MS using selective ion monitoring (SIM).The concentrations of THC and THC-COOH in oral fluid showed a large variation and the results from oral fluid and urine samples from cannabis abusers did not show any correlation. Thus, detailed information about time interval between drug use and sample collection is needed to interpret the oral fluid results properly. In addition, further investigation about the detection time window of THC and THC-COOH in oral fluid is required to substitute oral fluid for urine in drug testing.  相似文献   

9.
The aim of this project was to evaluate the Cozart RapiScan Oral fluid Drug Testing System as an on-site screening tool for vitreous humor samples collected during post-mortem examinations. Vitreous humor is easy to collect and as it is contained within the eye it is almost completely unaffected by post-mortem redistribution. The ability to carry out an initial drug screen on vitreous humor at the earliest stage of the death investigation process could contribute significantly to the assessment of the role drugs may have played prior to confirmation with toxicological analyses at the laboratory. Vitreous humor (n = 146) was collected from autopsy examinations (111 males and 35 females) with a specific focus on cases where death occurred following a road traffic accident or where an overdose was suspected. All samples were screened using the five-panel methadone Cozart RapiScan Cartridge with an overall positive rate of 29%. Of the positive results, 43% screened positive for benzodiazepines, 17% for cocaine, 7% for methadone and 33% for opiates. Positive samples, with the exception of benzodiazepines, and 20% of negative samples were analysed by GC/MS. This is the first reported use of this system as an on-site forensic tool in death investigation and for screening for drugs of abuse in vitreous humor. The conclusions from this study show that the Cozart RapiScan System could play an important role in obtaining information on the toxicological state of the person at the time of death.  相似文献   

10.
A qualitative and quantitative analytical method was developed and validated for the determination of 49 licit and illicit drugs in oral fluid. Small oral fluid samples, volume 1mL, were collected from volunteers using a modified Omni-Sal device and the analytes were extracted from an oral fluid/buffer mixture using a single Bond Elut Certify solid phase extraction cartridge. Liquid chromatography-tandem mass spectrometry (LC-MS-MS) and gas chromatography-repetitive full scan mass spectrometry (GC-MS) were used in parallel to analyze the extracts for the targeted drugs. Extracts were analyzed by GC-MS in their underivatized form and as their pentafluoropropionyl derivatives. Deuterated internal standards were used for quantification of drugs of abuse by LC-MS-MS to minimize matrix effects. Methadone-d(9) and tumoxetine were used as the internal standards for quantification of non-derivatized and derivatized analytes respectively by GC-MS. Linearity was demonstrated over the range 5-200 ng/mL and limits of detection were less than 4 ng/mL for each drug analyzed. The method demonstrated acceptable recoveries for most of the analytes and good intra- and inter-day precision. Acquisition of data by repetitive full scan GC-MS allows the addition of further analytes to the target menu.  相似文献   

11.
The objective of this study was to develop a two-step strategy for analysis of opiates and cocaine in hair samples involving an immunological screening procedure followed by confirmation of results using gas chromatography-mass spectrometry (GC-MS). A semi-quantitative automated competitive enzyme-linked immunosorbent assay (ELISA) methodology using Oral Fluid Micro-Plate Enzyme Immunoassays (Orasure Technologies, Inc.) was developed and validated. Applicability was proven by analysis of authentic head hair samples from drug users (n=103) and from opiate associated fatalities (n=21). The optimum cutoff values for the ELISA tests were 0.1 ng cocaine-equivalents/mg hair and 0.05 ng morphine-equivalents/mg hair using a 50 mg hair sample. Both ELISA tests had a sensitivity of 100%, the specificity was 66% for cocaine-equivalents and 42% for morphine-equivalents. The intraassay precision was 11% for the cocaine and 3% for the opiates ELISA, while interassay precision was 12% for the cocaine and 4% for the opiates ELISA test. The actual analyte concentrations in the hair samples were determined using GC-MS and were between 0.04 and 5.20 ng/mg for heroin (HER), between 0.04 and 30.01 ng/mg for 6-monoacetylmorphine (MAM), between 0.03 and 11.87 ng/mg for morphine (MOR), between 0.02 and 1.84 ng/mg for codeine (COD), between 0.02 and 2.48 ng/mg for acetylcodeine (AC), between 0.01 and 21.37 ng/mg for cocaine (COC), between 0.03 and 10.51 ng/mg for benzoylecgonine (BE) and between 0.05 and 1.26 ng/mg for cocaethylene (CE). The automated ELISA tests were proven to be valid screening procedures for the detection of cocaine and opiates in hair as confirmed by GC-MS. Screening methods provide rapid and inexpensive automated pre-test procedures to detect drugs in hair or other matrices. For forensic purposes screening therefore represents an ideal complement to routinely applied GC-MS procedures.  相似文献   

12.
This work presents the validation of a new immunological assay, the One-Step enzyme-linked immunosorbent assay (ELISA) tests from International Diagnostic Systems Corp. for the screening of drugs of abuse (cannabis, amphetamines, opiates, and cocaine) in human hair, with subsequent GC-MS confirmation. After decontamination and segmentation into small pieces, 50 mg of hair sample were incubated in 1 ml of methanol during 16 h at 40 degrees C. A 100 microL aliquot was collected and evaporated to dryness in presence of 100 microL of methanol/hydrochloric acid (99:1, v/v) to avoid amphetamines loss. The dried extract was dissolved in 100 microL of the "sample and standard diluent" solution included in the kit. This solution was submitted to analysis according to the recommended instructions of the manufacturer. During the validation phase, GC-MS confirmations were conducted according to our fully validated and published methods for opiates, cocaine, cannabis, and amphetamines determinations in hair. In a last development step, these procedures were slightly modified to directly confirm ELISA results by GC-MS using the methanolic extract. Ninety-three specimens were simultaneously screened by the ELISA tests (103 for tetrahydrocannabinol (THC)) and confirmed by GC-MS. Twenty were found positive for cannabis (THC: 0.10-6.50 ng/mg), 21 for cocaine (0.50-55.20 ng/mg), 24 for opiates (6-acetylmorphine (6-AM): 0.20-11.60 ng/mg, MOR: 0.20-8.90 ng/mg, codeine (COD): 0.20-5.90 ng/mg), and 13 for amphetamines (AP: 0.20 and 0.27 ng/mg, methamphetamine (MAP): 0.30 and 1.10 ng/mg, methylenedioxymethamphetamine (MDMA): 0.22-17.80 ng/mg). No false negative results were observed according to the Society of Hair Testing's (SoHT) cutoffs (0.5 ng/mg for cocaine, 0.2 ng/mg for opiates and amphetamines, and 0.1 ng/mg for THC). The One-Step ELISA kits appear suitable due to their sensitivity and specificity for drug of abuse screening in hair. This technology should find interest in workplace drug testing or driving license regranting, especially when many samples have to be tested with a high rate of negative samples, as ELISA is an easy and high-throughput method.  相似文献   

13.
Oral fluid is an interesting alternative matrix for drug testing in many environments, including law enforcement, workplace drug testing, and drug treatment facilities. Performance characteristics of the FDA-cleared, qualitative, Cozart RapiScan Opiate Oral Fluid Drug Testing System (Opiate Cozart RapiScan System or Opiate CRS) were compared to the semi-quantitative Cozart Microplate EIA Opiate Oral Fluid Kit (Opiate ELISA) and to gas chromatography/mass spectrometry (GC/MS). The following oral fluid opiate cutoffs were evaluated: the GC/MS limit of quantification (LOQ) of 2.5 mg/l; 15 microg/l currently used for oral fluid testing in the United Kingdom (UK); 30 microg/l (Opiate CRS cutoff); and 40 microg/l, the proposed Substance Abuse and Mental Health Services Administration (SAMHSA) cutoff. Subjects provided informed consent to participate in this IRB-approved research and resided on the closed research ward throughout the study. Three oral codeine doses of 60 mg/70 kg were administered over a 7-day period. After a 3-week break, subjects received three doses of 120 mg/70 kg within 7 days. Oral fluid specimens (N = 1273) were analyzed for codeine (COD), norcodeine (NCOD), morphine (MOR) and normorphine (NMOR) by GC/MS with an LOQ of 2.5 microg/l for all analytes. MOR and NMOR were not detected in any sample; 26.5% of the specimens were positive for COD and 13.7% for NCOD. Opiate CRS uses a preset, qualitative cutoff of 10 microg/l; this is equivalent to 30 microg/l in undiluted oral fluid as the oral fluid collection process involves a 1:3 dilution with buffer. Sensitivity, specificity, and efficiency of Opiate CRS compared to Opiate ELISA were 98.6, 98.1, and 98.2% at a 30 microg/l cutoff and 99.0, 96.2, and 96.6% at a 40 microg/l cutoff. Compared to the much lower GC/MS LOQ of 2.5 microg/l, sensitivity, specificity and efficiency were 66.8, 99.3 and 90.7%. Increasing the GC/MS cutoff to the current UK level yielded performance characteristics of 81.5% (sensitivity), 99.3% (specificity), and 95.4% (efficiency). Using a GC/MS cutoff identical to the preset Opiate CRS cutoff yielded sensitivity, specificity, and efficiency of 88.5, 99.2, and 97.5%, respectively. At the proposed SAMSHA confirmation cutoff of 40 microg/l, sensitivity increased with little change in specificity and efficiency (91.3% sensitivity, 98.9% specificity, and 97.5% efficiency). Oral fluid is a suitable matrix for detecting drugs of abuse. Opiate CRS, with a 30 microg/l cutoff, is sufficiently sensitive, specific and efficient for oral fluid opiate analysis, performing similarly to Opiate ELISA at the same cutoff, and having performance characteristics >91% when compared to GC/MS at the proposed SAMHSA cutoff.  相似文献   

14.
Drugged drivers pose a serious threat to other people in traffic as well as to themselves. Reliable oral fluid screening devices for on-site screening of drugged drivers would be both a useful and convenient means for traffic control. In this study we evaluated the appropriateness of Drugwipe 5 and Drugwipe Benzodiazepines oral fluid on-site tests for roadside drug screening. Drivers suspected of driving under the influence of drugs were screened with the Drugwipe tests. Oral fluid and whole blood samples were collected from the drivers and tested for amphetamine-type stimulant drugs, cannabis, opiates, cocaine and benzodiazepines by immunological methods, GC and GC-MS. The performance evaluations of the tests were made by comparing the results of the Drugwipe tests with laboratory GC-MS confirmation results of oral fluid or whole blood. In addition to the performance evaluations of the Drugwipe tests based on laboratory results, a questionnaire on the practical aspects of the tests was written for the police officers who performed the tests. The aim of the questionnaire was to obtain user comments on the practicality of the tests as well as the advantages and weak points of the tests. The results of the performance evaluations were: for oral fluid (sensitivity; specificity; accuracy) amphetamines (95.5%; 92.9%; 95.3%), cannabis (52.2%; 91.2%; 85.1%), cocaine (50.0%; 99.3%; 98.6%), opiates (100%; 95.8%; 95.9%), benzodiazepines (74.4%; 84.2%; 79.2%) and for whole blood accordingly, amphetamines (97.7%; 86.7%; 95.9%), cannabis (68.3%; 87.9%; 84.9%), cocaine (50.0%; 98.5%; 97.7%), opiates (87.5%; 96.9%; 96.6%) and benzodiazepines (66.7%; 87.0%; 74.4%). Although the Drugwipe 5 successfully detected amphetamine-type stimulant drugs and the police officers were quite pleased with the current features of the Drugwipe tests, improvements must still be made regarding the detection of cannabis and benzodiazepines.  相似文献   

15.
Identification of 6-acetylmorphine, a specific metabolite of heroin, is considered to be definitive evidence of heroin use. Although 6-acetylmorphine has been identified in oral fluid following controlled heroin administration, no prevalence data is available for oral fluid specimens collected in the workplace. We evaluated the prevalence of positive test results for 6-acetylmorphine in 77,218 oral fluid specimens collected over a 10-month period (January-October 2001) from private workplace testing programs. Specimens were analyzed by Intercept immunoassay (cutoff concentration=30 ng/ml) and confirmed by GC-MS-MS (cutoff concentrations=30 ng/ml for morphine and codeine, and 3 ng/ml for 6-acetylmorphine). Only morphine-positive oral fluid specimens were tested by GC-MS-MS for 6-acetylmorphine. A total of 48 confirmed positive morphine results were identified. An additional 107 specimens were confirmed for codeine only. Of the 48 morphine-positive specimens, 32 (66.7%) specimens were positive for 6-acetylmorphine. Mean concentrations (+/-S.E.M.) of morphine, 6-acetylmorphine and codeine in the 32 specimens were 755+/-201, 416+/-168 and 196+/-36 ng/ml, respectively. Concentrations of 6-acetylmorphine in oral fluid ranged from 3 to 4095 ng/ml. The mean ratio (+/-S.E.M.) of 6-acetylmorphine/morphine was 0.33+/-0.06. It is suggested that, based on controlled dose studies of heroin administration, ratios >1 of 6-acetylmorphine/morphine in oral fluid are consistent with heroin use within the last hour before specimen collection. The confirmation of 6-acetylmorphine in 66.7% of morphine-positive oral fluid specimens indicates that oral fluid testing for opioids may offer advantages over urine in workplace drug testing programs and in testing drugged drivers for recent heroin use.  相似文献   

16.
In a double-blind placebo controlled study on psychomotor skills important for car driving (Study 1), a 75 mg dose of +/- 3,4-methylenedioxymethamphetamine (MDMA) was administered orally to 12 healthy volunteers who were known to be recreational MDMA-users. Toxicokinetic data were gathered by analysis of blood, urine, oral fluid and sweat wipes collected during the first 5h after administration. Resultant plasma concentrations varied from 21 to 295 ng/ml, with an average peak concentration of 178 ng/ml observed between 2 and 4h after administration. MDA concentrations never exceeded 20 ng/ml. Corresponding MDMA concentrations in oral fluid, as measured with a specific LC-MS/MS method (which required only 50 microl of oral fluid), generally exceeded those in plasma and peaked at an average concentration of 1215 ng/ml. A substantial intra- and inter-subject variability was observed with this matrix, and values ranged from 50 to 6982 ng/ml MDMA. Somewhat surprisingly, even 4-5h after ingestion, the MDMA levels in sweat only averaged 25 ng/wipe. In addition to this controlled study, data were collected from 19 MDMA-users who participated in a driving simulator study (Study 2), comparing sober non-drug conditions with MDMA-only and multiple drug use conditions. In this particular study, urine samples were used for general drug screening and oral fluid was collected as an alternative to blood sampling. Analysis of oral fluid samples by LC-MS/MS revealed an average MDMA/MDEA concentration of 1121 ng/ml in the MDMA-only condition, with large inter-subject variability. This was also the case in the multiple drug condition, where generally, significantly higher concentrations of MDMA, MDEA and/or amphetamine were detected in the oral fluid samples. Urine screening revealed the presence of combinations such as MDMA, MDEA, amph, cannabis, cocaine, LSD and psilocine in the multiple-drug condition.  相似文献   

17.
The aim of this study was to assess the effectiveness of two current on-site oral fluid (OF) drug detection devices (OraLab and Dr?ger), as part of the Spanish participation in the Roadside Testing Assessment Project (ROSITA Project). The study was done in collaboration with the Spanish Traffic Police, in Galicia (NW Spain), during 2004 and 2005. A total of 468 drivers selected at the police controls agreed to participate through informed consent. In addition, saliva samples were collected and sent to the laboratory to confirm the on-site results. For this purpose, two different analytical liquid chromatography-mass spectrometry (LC-MS) methods were used to detect 11 drugs or metabolites in a 300 microL sample. Simultaneous analysis of morphine, 6-acetylmorphine, amphetamine, methamphetamine, MDA, MDMA, MDEA, MBDB, cocaine and benzoylecgonine was carried out using 100 microL of oral fluid, after an automated solid phase extraction. A different LC-MS method was performed to detect Delta(9)-THC in 200 microL of oral fluid using liquid-liquid extraction with hexane at pH 6. Both methods were fully validated, including linearity (1-250 ng/mL, 2-250 ng/mL) recovery (>50%), within-day and between-day precision (CV<15%), accuracy (mean relative error<15%), limit of detection (0.5 and 1 ng/mL), quantitation (1 and 2 ng/mL) and matrix effect. All of the positive cases and a random selection of 30% of the negatives were analyzed for confirmation analysis. Good results (sensitivity, specificity, accuracy, positive predictive value and negative predictive value>90%) were obtained for cocaine and opiates by OraLab, and for cocaine by Dr?ger. However, the results for the other compounds could be improved for both detection devices. Differences in the ease of use and in the interpretation mode (visual or instrumental) were observed.  相似文献   

18.
A sensitive GC-MS method for the simultaneous determination of opiates, cocaine, and metabolites in hair at a cut-off level of 0.1 ng/mg was adopted to assess past exposure to these drugs in applicants for driving licenses with a history of drug use. The sampling protocol consisted of collection of one hair (sample A, 5-cm length) and one urine sample. When hair and urine (EMIT Syva, cut-off levels: 0.3 mg/l for opiates, 0.15 mg/l for cocaine, GC-MS confirmation of positives) were both positive or negative the protocol was concluded. In the other cases, the assessment of 'current exposure' to drugs was carried out, in order to avoid seriated random urinalysis, by collecting a second hair sample (sample B) 6 weeks later and analysing the proximal 1-cm segment. Out of the 214 'A' hair samples analyzed, 14 (6.5%) tested positive for morphine and/or 6-acetylmorphine (6AM), and 26 (12%) for cocaine and/or benzoylecgonine (BE), whereas none of the samples tested positive for both drugs. Levels between 0.1 and 1 ng/mg of the single analytes were found in eight out of the 14 morphine-6AM positives (57%) and in 18 out of the 26 cocaine-BE positives (69%). The time course of positive cases showed a progressive decrease of morphine-6AM positives and a corresponding increase of cocaine-BE positives within the study period September 1995-February 1999. No cases with positive urine and negative hair were observed. Among the 40 positive cases, seven (four and three for opiates and cocaine, respectively) were found to be 'currently exposed to drug', four by urinalysis (three and one) and three by analysis of the hair sample B (1 and 2).  相似文献   

19.
Oral fluid is becoming increasingly useful for the detection of drugs, since it is a non-invasive specimen to collect and, because collection is directly observed, it is difficult to adulterate. A point-of-collection (POCT) oral fluid drug analysis kit has been developed for use in many drug testing situations. This paper summarizes the results of field evaluations of the ORALscreen System for screening of drugs in oral fluid. The ORALscreen System consists of an oral fluid collection device and a test device containing a lateral flow membrane immunoassay system. Paired samples (oral fluid and urine) were collected from drug users and the results from the ORALscreen POCT system were compared to urine screening results conducted in a licensed laboratory. The results demonstrate that the ORALscreen System has excellent percent agreement with the laboratory-based urine screening test results for the detection of cocaine and opiates through 2.5-3 days following drug use, respectively. Tetrahydrocannabinol (THC) was detected by ORALscreen on the day of use and 1 day after use. Good correlation between urine and oral fluid screening results was observed for the methamphetamine positive samples; however, the number of days following drug use was not determined.  相似文献   

20.
Phenylalkylamine derivatives, such as methamphetamine (MA), amphetamine (AM), 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyamphetamine (MDA), phentermine (PT), fenfluramine (FFA) and phenmetrazine (PM), and ketamine (KT) are widely abused recreational or anorectic drugs in Korea and are regulated under the Controlled Substance Act in Korea. Phenylalkylamines and ketamine analysis is normally performed using both urine and hair samples but there is no established method for the simultaneous analysis of all these phenylalkylamines and ketamine in oral fluids. Oral fluid is easy to collect/handle and can provide an indication of recent drug abuse. In this study, to confirm the presence of phenylalkylamine derivatives and ketamine in oral fluid after screening with an immunoassay, an analytical method using automated solid phase extraction (SPE) and gas chromatography-mass spectrometry (GC-MS) was developed and fully validated according to international guidelines. The applicability of the assay was demonstrated by analyzing of authentic oral fluid samples and the results of oral fluid analysis were compared with those in urine and hair to to evaluate the feasibility of oral fluid in forensic cases. The recovery of phenylalkylamines and ketamine from oral fluid collection devices was also assessed. Oral fluid specimens from 23 drug abuse suspects submitted by the police were collected using Salivette (Sarstedt, Nümbrecht, Germany), Quantisal (Immunalysis, Pomona, CA) or direct expectoration. The samples were screened using a biochip array analyzer (Evidence Investigator, Randox, Antrim, UK). For confirmation, the samples were analyzed by GC-MS in selected-ion monitoring (SIM) mode after extraction using automated SPE (RapidTrace, Zymark, MA, USA) with a mixed-mode cation exchange cartridge (CLEAN SCREEN, 130 mg/3 ml, UCT, PA, USA) and derivatization with trifluoroacetic anhydride (TFA). The results from the immunoassay were consistent with those from GC-MS. Twenty oral fluid samples gave positive results for MA, AM, PT and/or PM among the 23 cases, which gave positive results in urine and/or hair. Although large variations in the MA, AM, PT and PM concentrations were observed in three different specimens, the oral fluid specimen was useful for demonstrating phenylalkylamines and ketamine abuse as an alternative specimen for urine.  相似文献   