首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 23 毫秒
1.
Infrared spectroscopy has proved to be a very useful method for the routine identification of man-made textile fibres. This paper describes the way in which this technique can fit into casework procedure using two different preparative methods. Spectra can be recorded from samples of 3 μg down to less than 1 μg in weight.  相似文献   

2.
Forensic reports on traumatic peripheral nerve injuries include dysfunction degrees of extremities, which are arranged according to the Turkish Penalty Code. The aim of this study is to discuss the role and importance of electromyography while preparing forensic reports in the cases of traumatic peripheral nerve injuries and the usefulness of scoring systems. A modified global scale, recommended by Mondelli et al., was used to assess the electrophysiological impairment of each peripheral nerve. Forensic reports of 106 patients, reported between 2002 and 2004, were evaluated. Thirty-four percent of the cases were reported as "total loss of function," 41.5% were reported as "functional disability," and there were no dysfunctions in the other cases in forensic reports that were prepared based on Council of Social Insurance Regulations of Health Processes and Guide prepared by the Council of Forensic Medicine and profession associations of forensic medicine. When we rearranged these forensic reports based on the electrophysiological severity scale (ESS), it was clearly found that all of the score 2 cases and 86.7% of the score 3 cases corresponded to "functional disability" and 91.4% of the score 4 cases correspond to "total loss of function." We found a significant correlation between the ESS and functional evaluation in peripheral nerve injury cases. Evaluation of functional disabilities in peripheral nerve injuries with the ESS represents a standardized and objective method used for forensic reports.  相似文献   

3.
《Science & justice》2020,60(5):480-485
This study demonstrates how RGB color values from microscopic smears stained with the Periodic Acid-Schiff reagent under standardized microscopy conditions can be used to indicate the presence of vaginal secretions. Based on data obtained in the study, a numeric threshold determined from the sum of separate values for red, blue and green was determined to differentiate vaginal-based samples with other body fluids. Using this threshold, 55 of 57 vaginal-based samples tested positive for the presence of vaginal secretion. Conversely, 27 of 29 smears prepared from other body fluids yielded negative results. However, when graphing RGB sum values against a calculated RGB integer no overlap in data was obtained between all vaginal-based samples and other body fluid samples, clearly differentiating them. One-way ANOVA testing with a 95% confidence interval indicated that vaginal samples from different age groups showed no difference in RGB sum values. Similarly, the location that vaginal swabs were collected (from the outside of a condom or a vaginal swab) also showed no statistical difference using one-way ANOVA at 95% confidence. Furthermore, refrigerated test swabs aged up to 15 months showed no demonstrable differences. Pair-wise t-testing using RGB sum values, however, did show significant differences between vaginal samples and all other body fluids tested. Finally, the method successfully differentiated between pre-and post-coital penile swabs and finger swabs taken before and after digital vaginal penetration in anecdotal comparisons using the method.  相似文献   

4.
A physical fit is an important observation that can result from the forensic analysis of trace evidence as it conveys a high degree of association between two items. However, physical fit examinations can be time-consuming, and potential bias from analysts may affect judgment. To overcome these shortcomings, a data analysis algorithm using mutual information and a decision tree has been developed to support practitioners in interpreting the evidence. We created these tools using data obtained from physical fit examinations of duct tape and textiles analyzed in previous studies, along with the reasoning behind the analysts' decisions. The relative feature importance is described by material type, enhancing the knowledge base in this field. Compared with the human analysis, the algorithms provided accuracies above 90%, with an improved rate of true positives for most duct tape subsets. Conversely, false positives were observed in high-quality scissor cut (HQ-HT-S) duct tape and textiles. As such, it is advised to use these algorithms in tandem with human analysis. Furthermore, the study evaluated the accuracy of physical fits when only partial sample lengths are available. The results of this investigation indicated that acceptable accuracies for correctly identifying true fits and non-fits occurred when at least 35% of a sample length was present. However, lower accuracies were observed for samples prone to stretching or distortion. Therefore, the models described here can provide a valuable supplementary tool but should not be the sole means of evaluating samples.  相似文献   

5.
Testing the reliability of frontal sinuses in positive identification   总被引:4,自引:0,他引:4  
The use of frontal sinus radiographs in positive identification has become an increasingly applied and accepted technique among forensic anthropologists, radiologists, and pathologists. From an evidentiary standpoint, however, it is important to know whether frontal sinus radiographs are a reliable method for confirming or rejecting an identification, and standardized methods should be applied when making comparisons. The purpose of the following study is to develop an objective, standardized comparison method, and investigate the reliability of that method. Elliptic Fourier analysis (EFA) was used to assess the variation in 808 outlines of frontal sinuses by calculating likelihood ratios and posterior probabilities from EFA coefficients. Results show that using EFA coefficient comparison to estimate the probability of a correct identification is a reliable technique, and EFA comparison of frontal sinus outlines is recommended when it may be necessary to provide quantitative substantiation for a forensic identification based on these structures.  相似文献   

6.
Forensic paint comparisons are generally conducted on samples which, while small relative to their source, are still visible to the unaided eye and are thus located and analyzed without great difficulty. Here we demonstrate that a more detailed examination of candidate transfer surfaces can capture materials (questioned samples), even when such traces are invisible to the unaided eye. While certain analytical details (such as layer sequence or a pure FTIR spectrum) may not be obtainable from such traces due to their size and condition, a detailed analysis of the sample characteristics that are analytically accessible may still provide sufficient analytical data to arrive at a probative result. Here we present the application of this approach to a suspected paint transfer case, involving particles of paint as small as 40 μm in size. Using a combination of stereomicroscopy, polarized light microscopy, infrared microspectroscopy, Raman microspectroscopy, and SEM/EDS, all performed on a single, subsample of the original minute particle, it was possible to demonstrate evidence of a two‐way transfer between the suspected sources. Furthermore, the transferred paint particle in one direction could be classified as automotive in nature based on a combination of polymer composition, microscopic texture, and pigment package (which included three specifically identified pigments). This work demonstrates (i) the potential for improving detection limits when searching for a questioned sample, (ii) the potential benefits of higher resolution analyses on samples that would be traditionally labeled as “sample‐size limited,” and (iii) the value of case‐specific interpretation over standardized, one‐size fits all report templates.  相似文献   

7.
This study was undertaken to apply a new method of controlling type I error when performing pairwise comparisons. The Benjamini and Hochberg false discovery rate (FDR) controlling procedures have proved to be very powerful tools in solving many practical problems but have not yet been applied to pairwise comparisons of refractive index of glass samples. Students t-test and Welch test (unequal variance Student's t-test) were applied to all possible pairwise comparisons. The comparisons were made on the basis of refractive index values of 72 glass fragments from different car windows and 69 different fragments from one windscreen. The type I error was controlled by the use of Benjamini and Hochberg false discovery rate (FDR) controlling procedure. To illustrate the importance of controlling type I error when using pairwise comparisons, results of pairwise comparisons with the FDR controlling procedure were compared to those comparisons made without any controlling procedure. Significantly fewer false negative results (false rejection of H0) were found during the use of FDR procedure in the comparison of refractive indices from the same windscreen than when comparing without controlling type I error. The results of application of FDR method were also compared to the results of other post-hoc tests, such as Tukey HSD test and Bonfferoni test. The FDR method has higher power than Bonferroni method and Tukey HSD method and control errors better than comparing without controlling type I error. The method of choice, for pairwise comparison of glass fragments on the basis of refractive index is Welch test with FDR adjustment. The method gave type I errors at level about 5.3% and type II error at about 3.7%.  相似文献   

8.
Multiple analytical techniques for the screening of fentanyl-related compounds exist. High discriminatory methods such as GC–MS and LC–MS are expensive, time-consuming, and less amenable to onsite analysis. Raman spectroscopy provides a rapid, inexpensive alternative. Raman variants such as electrochemical surface-enhanced Raman scattering (EC-SERS) can provide signal enhancements with 1010 magnitudes, allowing for the detection of low-concentration analytes, otherwise undetected using conventional Raman. Library search algorithms embedded in instruments utilizing SERS may suffer from accuracy when multicomponent mixtures involving fentanyl derivatives are analyzed. The complexing of machine learning techniques to Raman spectra demonstrates an improvement in the discrimination of drugs even when present in multicomponent mixtures of various ratios. Additionally, these algorithms are capable of identifying spectral features difficult to detect by manual comparisons. Therefore, the goal of this study was to evaluate fentanyl-related compounds and other drugs of abuse using EC-SERS and to process the acquired data using machine learning—convolutional neural networks (CNN). The CNN was created using Keras v 2.4.0 with Tensorflow v 2.9.1 backend. In-house binary mixtures and authentic adjudicated case samples were used to evaluate the created machine-learning models. The overall accuracy of the model was 98.4 ± 0.1% after 10-fold cross-validation. The correct identification for the in-house binary mixtures was 92%, while the authentic case samples were 85%. The high accuracies achieved in this study demonstrate the advantage of using machine learning to process spectral data when screening seized drug materials comprised of multiple components.  相似文献   

9.
Fluorescence microscope is considered to be one of the most effective ways to examine the sequence of intersecting seal and toner lines of questioned documents. In reality, however, the toner (mainly divided into compact and noncompact toners) and seal of a questioned document have such a complex morphology and sequence of crossing lines that current methods cannot meet the requirement of practical document identification. In view of the challenges of document examination, a laser fluorescence microscope and method are developed in this study. The developed microscope provides additional functionality to traditional fluorescence microscopes of transmitted light modality, laser excitation, selectable excitation wavelength, and selectable fluorescence filters. The results obtained from the method of comparisons between transmitted light and fluorescence modalities were positive under most conditions, particularly for noncompact toner examination for which a 100% accuracy rate and 90% detection rate were achieved in blind testing.  相似文献   

10.
During the forensic examination of textile fibers, fibers are usually mounted on glass slides for visual inspection and identification under the microscope. One method that has the capability to accurately identify single textile fibers without subsequent demounting is Raman microspectroscopy. The effect of the mountant Entellan New on the Raman spectra of fibers was investigated to determine if it is suitable for fiber analysis. Raman spectra of synthetic fibers mounted in three different ways were collected and subjected to multivariate analysis. Principal component analysis score plots revealed that while spectra from different fiber classes formed distinct groups, fibers of the same class formed a single group regardless of the mounting method. The spectra of bare fibers and those mounted in Entellan New were found to be statistically indistinguishable by analysis of variance calculations. These results demonstrate that fibers mounted in Entellan New may be identified directly by Raman microspectroscopy without further sample preparation.  相似文献   

11.
Plastic bags are frequently used to package drugs, explosives and other contraband. There exists, therefore, a requirement in forensic casework to compare bags found at different locations. This is currently achieved almost exclusively by the use of physical comparisons such as birefringence patterns. This paper discusses some of the advantages and shortcomings of this approach, and presents stable isotope ratio mass spectrometry (IRMS) as a supplementary tool for effecting comparisons of this nature. Carbon and hydrogen isotopic data are presented for sixteen grip-seal plastic bags from a wide range of sources, in order to demonstrate the range of values which is likely to be encountered. Both isotopic and physical comparison (specifically birefringence) techniques are then applied to the analysis of rolls of bags from different manufacturing lots from a leading manufacturer. Both approaches are able to associate bags from a common production batch. IRMS can be applied to small fragments which are not amenable to physical comparisons, and is able to discriminate bags which could be confused using birefringence patterns alone. Similarly, in certain cases birefringence patterns discriminate bags with similar isotopic compositions. The two approaches are therefore complementary. When more than one isotopically distinct region exists within a bag (e.g. the grip-seal is distinct from the body) the ability to discriminate and associate bags is greatly increased.  相似文献   

12.
In this study, δ13C values of six cocaine samples were identified and classified using a single quadrupole mass spectrometer and an isotope ratio mass spectrometry (IRMS) as simultaneous gas chromatography detectors. Our instrument modification is simple to use and is useful (i) when the sample is of limited size or can only be injected once, (ii) to help identify peaks in a complicated IRMS chromatogram, and (iii) to help differentiate very simple systems when impurity profiling is not possible. The EI-MS confirmed the identity of cocaine in each sample. The IRMS data distinguished 12 of the 15 possible pair-wise comparisons at the 95% CL. Three samples could not be differentiated by their δ13C ratios for cocaine. ANOVA demonstrated that the measurement variance was consistently larger than the sample variance. As the δ13C values clearly show, this technique enables the exclusion of a potential common source even when two samples have otherwise identical chemical and physical properties.  相似文献   

13.
Comparison techniques used in bite mark analysis are many and varied, the choice of technique depending largely on personal preference. Until recently, no one technique has been shown to be better than the others, and very little research has been carried out to compare different methods. This study evaluates and compares the accuracy of direct comparisons between suspects' models and bite marks with indirect comparisons in the form of conventional traced overlays of suspects' models or a new method using photocopier-generated overlays. Artificial bite marks in pigskin were made using standardized sets of models and recorded as photographs and fingerprint powder lifts on tape. The bite mark photographs and fingerprint lifts were coded and randomized so that a blind comparison could be made with the models, traced overlays, and photocopier-generated overlays using a modified version of the American Board of Forensic Odontology Scoring (ABFO) System for Bite Marks. It was found that the photocopier-generated overlays were significantly more accurate at matching the correct bite mark to the correct models irrespective of whether the bite mark was recorded photographically or as a fingerprint lift. The photocopier-generated overlays were also found to be more sensitive at matching the correct bite marks to the correct models than the other two methods used. The modified ABFO scoring system was able to discriminate between a correct match and several incorrect matches by awarding a high score to the correct match.  相似文献   

14.
Female homicide-suicide perpetrators: a controlled study   总被引:1,自引:0,他引:1  
The record files of the Dade County Medical Examiner Department were reviewed and 133 homicide-suicides were identified. Of these, ten (or 7.5%) were female perpetrated. The chart data of these 10 female homicide-suicide perpetrators, chart data of 50 female homicide-suicide victims, and 50 female individual suicides systematically selected as controls were tabulated using a standardized instrument. The results were analyzed for differences using simple statistical methods. The comparisons revealed that female homicide-suicide perpetrators were more likely than female homicide-suicide victims to live in mobile homes, kill their lover or ex-lover, have their crime accidentally discovered, leave a suicide note, kill on a weekend, and be depressed, but are less likely than female homicide-suicide victims to live with a spouse. Additionally, female homicide-suicide perpetrators were more likely than individual female suicides to live in mobile homes but less likely to live alone and to be depressed.  相似文献   

15.
The CEPH human genome diversity cell line panel (CEPH-HGDP) of 51 globally distributed populations was used to analyze patterns of variability in 20 core human identification STRs. The markers typed comprised the 15 STRs of Identifiler, one of the most widely used forensic STR multiplexes, plus five recently introduced European Standard Set (ESS) STRs: D1S1656, D2S441, D10S1248, D12S391 and D22S1045. From the genotypes obtained for the ESS STRs we identified rare, intermediate or off-ladder alleles that had not been previously reported for these loci. Examples of novel ESS STR alleles found were characterized by sequence analysis. This revealed extensive repeat structure variation in three ESS STRs, with D12S391 showing particularly high variability for tandem runs of AGAT and AGAC repeat units. The global geographic distribution of the CEPH panel samples gave an opportunity to study in detail the extent of substructure shown by the 20 STRs amongst populations and between their parent population groups. An assessment was made of the forensic informativeness of the new ESS STRs compared to the loci they will replace: CSF1PO, D5S818, D7S820, D13S317 and TPOX, with results showing a clear enhancement of discrimination power using multiplexes that genotype the new ESS loci. We also measured the ability of Identifiler and ESS STRs to infer the ancestry of the CEPH-HGDP samples and demonstrate that forensic STRs in large multiplexes have the potential to differentiate the major population groups but only with sufficient reliability when used with other ancestry-informative markers such as single nucleotide polymorphisms. Finally we checked for possible association by linkage between the two ESS multiplex STRs closely positioned on chromosome-12: vWA and D12S391 by examining paired genotypes from the complete CEPH data set.  相似文献   

16.
This case report demonstrates a rape case, where no semen, hair, or fingerprints were left by the perpetrator at the crime scene, but rather uncharacteristic biological and physical evidence in the form of a lollipop and a pair of glasses. Three separate forensic laboratories collaborated using conventional forensic methods of PCR DNA typing, photography, and toolmark comparisons to provide investigators with scientific evidence which in turn was instrumental in bringing a violent criminal to justice. The importance of evaluating each item of evidence and realizing its forensic value is stressed in this case report.  相似文献   

17.
Forensic firearm examination provides the court of law with information about the source of fired cartridge cases. We assessed the validity of source decisions of a computer‐based method and of 73 firearm examiners who compared breechface and firing pin impressions of 48 comparison sets. We also compared the computer‐based method's comparison scores with the examiners' degree‐of‐support judgments and assessed the validity of the latter. The true‐positive rate (sensitivity) and true‐negative rate (specificity) of the computer‐based method (for the comparison of both the breechface and firing pin impressions) were 94.4% and at least 91.7%, respectively. For the examiners, the true‐positive rate was at least 95.3% and the true‐negative rate was at least 86.2%. The validity of the source decisions improved when the evaluations of breechface and firing pin impressions were combined and for the examiners also when the perceived difficulty of the comparison decreased. The examiners were reluctant to provide source decisions for "difficult" comparisons even though their source decisions were mostly correct. The correlation between the computer‐based method's comparison scores and the examiners' degree‐of‐support judgments was low for the same‐source comparisons to negligible for the different‐source comparisons. Combining the outcomes of computer‐based methods with the judgments of examiners could increase the validity of firearm examinations. The examiners' numerical degree‐of‐support judgments for their source decisions were not well‐calibrated and showed clear signs of overconfidence. We suggest studying the merits of performance feedback to calibrate these judgments.  相似文献   

18.
The concentrations of ten elements in 209 unrelated glass specimens received as evidence were used to assess the frequencies of errors of false association (Type II errors) using several comparison criteria at specified significance levels (Type I errors). Pairwise comparisons of the samples using either the equal-variance t-test or Welch's modification (unequal variances) result in a small number of errors of false association, even when adjusting the significance level (Bonferroni correction) for multivariate comparisons. At the 95% confidence level (overall Type I error of 0.05, or individual element comparison error of 0.005), only two Type II errors are made in 21736 comparisons (0.009%) when using the equal-variance t-test for comparison of sample means. In this study, the range overlap test using three replicate measurements per specimen results in no errors of false association. Most specimen pairs in this data set are readily discriminated either by differences in the concentrations of several elements or by an extremely large difference in the concentrations of one or more element.  相似文献   

19.
According to their standardized treatment within the Indian legal tradition (Dharmaśāstra), ordeals (Sanskrit: divya) are supposed to occur, under certain circumstances, when one person formally accused another of some crime in a court of law. While not disputing the general accuracy of this standardized treatment of ordeals, this article argues for the widespread practice in pre-modern India of another—hitherto unrecognized—type of ordeal that fails to fit this basic scenario, for such ordeals would occur when someone was widely believed to have committed some wrongdoing, but was not forced to stand trial in a formal judicial court. In order to prove his innocence and, thereby, mitigate the damage caused by his suspected guilt, such an individual could—and sometimes did—arrange for himself to undergo an ordeal at his own expense and independently of any formal plaint. After establishing the practice of ordeals of this sort in pre-modern India, this article then examines some possible explanations for their development.  相似文献   

20.
The foreign textile fibers recovered from one item of evidence from each of 20 unrelated crimes in three categories (bank robbery, kidnapping, and homicide) were cross-compared. The items of evidence were scraped to remove the trace evidence and a sample of the collected fibers was examined using a standard scheme of analysis. The fibers were examined with light microscopy (including polarized light microscopy), fluorescence microscopy, and microspectrophotometry. The fibers were divided into natural and manufactured groups and then categorized by color and generic (polymer) class. Cross-comparing all 2083 fibers resulted in 2,168,403 comparisons, after removing duplicate (same fiber) comparisons. Colorless and denim fibers were excluded from this study. No two fibers were found to exhibit the same microscopic characteristics and analytical properties. Therefore, it is rare to find two unrelated items that have foreign fibers that are analytically indistinguishable. These results corroborate other population studies conducted in Europe and target fiber studies conducted both in the US and in Europe.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号