首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In forensic genetic analyses, mixtures of various biological materials are common samples. Micromanipulation, which is performed based on differences in cellular morphology, is an effective method for the isolation of cells from mixtures. In this study, mucosal cell was isolated from somatic cellular mixtures (blood and saliva) based on micromanipulation and a low volume‐PCR (LV‐PCR) platform. One hundred and twenty‐six parallel LV‐PCR processes were performed using an Identifiler® kit, with 107 reactions yielding single‐source DNA profiles. Among them, 54 full profiles (50%) and 37 partial profiles (13–15 loci) were obtained. Based on the above method, we obtained a single‐source DNA profile from a cigarette butt contaminated by two victims’ blood in a murder case. The generated genotype was used to query a DNA database, and a perfect match was found.  相似文献   

2.
PowerPlex® Y23 is a novel kit for Y‐STR typing that includes new highly discriminating loci. The Israel DNA Database laboratory has recently adopted it for routine Y‐STR analysis. This study examined PCR amplification from 1.2‐mm FTA punch in reduced volumes of 5 and 10 μL. Direct amplification and washing of the FTA punches were examined in different PCR cycle numbers. One short robotically performed wash was found to improve the quality and the percent of profiles obtained. The optimal PCR cycle number was determined for 5 and 10 μL reaction volumes. The percent of obtained profiles, color balance, and reproducibility were examined. High‐quality profiles were achieved in 90% and 88% of the samples amplified in 5 and 10 μL, respectively, in the first attempt. Volume reduction to 5 μL has a vast economic impact especially for DNA database laboratories.  相似文献   

3.
Abstract: A year after the introduction of Identifiler? into the forensic DNA laboratories of the Institute of Environmental Science and Research Limited (ESR), increasing occurrences of dropout of the three loci, D7S820, D18S51, and FGA, were observed in samples where the DNA was not degraded and sufficient DNA was present that full DNA profiles were to be expected. The dropout was either partial or complete at these loci. Full profiles could sometimes be obtained by reamplification of samples using the same input amount of DNA. After a thorough investigation of the methods and procedures used in the laboratory, the cause of this inhibition was identified as the cleaning agent TriGene? ADVANCE. This was determined after the deliberate addition of varying amounts of different cleaning reagents into the DNA amplification reactions. At concentrations of 0.004% TriGene? ADVANCE caused inhibition resulting in tri‐loci dropout. At concentrations of 0.04% and higher, complete inhibition was observed. An effect was also seen on the amplification of samples using the Y STR profiling system PowerPlex®Y. This work highlights the importance of checking all reagents and chemicals prior to use, even those with no apparent direct influence on the DNA profiling process.  相似文献   

4.
Abstract: The quality and efficiency of a standard organic DNA isolation method and a silica‐based method using the QIAGEN Blood Maxi Kit were compared to obtain human DNA and short tandem repeats (STRs) profiles from 39 exhumed bone samples for paternity testing. DNA samples were quantified by real‐time PCR, and STR profiles were obtained using the AmpFlSTR® Identifiler® PCR amplification kit. Overall, the silica‐based method recovered less DNA ranging from 0 to 147.7 ng/g (average 7.57 ng/g, median = 1.3 ng/g) than did the organic method ranging from 0 to 605 ng/g (average 44.27 ng/g, median = 5.8 ng/g). Complete profiles (16/16 loci tested) were obtained from 37/39 samples (95%) using the organic method and from 9/39 samples (23%) with the silica‐based method. Compared with a standard organic DNA isolation method, our results indicate that the published silica‐based method does not improve neither the quality nor the quantity of DNA for STR profiling.  相似文献   

5.
The majority of microfluidic devices used as a platform for low‐cost, rapid DNA analysis are glass devices; however, microchip fabrication in glass is costly and laborious, enhancing the interest in polymeric substrates, such as poly (methyl methacrylate) (PMMA), as an inexpensive alternative. Here, we report amplification in PMMA polymerase chain reaction (PCR) microchips providing full short tandem repeat profiles (16 of 16 loci) in 30–40 min, with peak height ratios and stutter percentages that meet literature threshold requirements. In addition, partial profiles (15 of 16 loci) were generated using an ultrafast PCR method in 17.1 min, representing a ~10‐fold reduction in reaction time as compared to current amplification methods. Finally, a multichamber device was demonstrated to simultaneously amplify one positive, one negative, and five individual samples in 39 min. Although there were instances of loci dropout, this device represents a first step toward a microfluidic system capable of amplifying more than one sample simultaneously.  相似文献   

6.
Current forensic DNA profiling methods rely on the analysis of samples at specialised laboratories with an average turnaround time of several days. The ability to rapidly determine a partial profile of short tandem repeats at the point-of-arrest would be of great benefit to police forces around the world, for example enabling a suspect to be rapidly included or excluded from an investigation. We have developed a homogeneous PCR method for the interrogation of STR loci utilising fluorescent oligonucleotide probes and melting curve analysis. Alleles of the D18S51, TH01 and D8S1179 loci were differentiated and identified on the basis of target length and probe melting temperature. Assay performance was evaluated by comparing melting peak data with the AmpFlSTR® SGM Plus® system. The method is compatible with direct analysis of unpurified buccal swab samples, enabling a partial STR profile to be generated within 1 h.  相似文献   

7.
《Science & justice》2020,60(6):567-572
Forensic DNA profiling is a standard method used in the attempt to identify deceased individuals. In routine investigations, and if available, the preferred sample type is usually blood. However, this requires the invasive re-opening of the body, days or weeks after the autopsy, which is undesirable in resource-constrained mortuary settings. Motivated by the ease of sampling as well as reduced health and safety risks, this study aimed to establish the success rate of generating a full DNA profile on first attempt from buccal swab lysates using a direct PCR approach. Buccal swab samples were collected from 100 unidentified deceased males, and were subjected to direct DNA profiling with use of the Promega PowerPlex® Y23 Kit. At the time of sample collection, these individuals had been stored for between 1 and 887 days. This study shows that full DNA profiles were initially obtained from 73% of samples, which constitutes the first empirical data pertaining to first time success rates of direct PCR from post-mortem buccal lysates. Further investigation of partial and failed DNA profiles using real-time PCR showed that samples did not contain PCR inhibitors, DNA was not degraded, but DNA concentration was particularly low. Repeating DNA profiling with increased lysate input and extra PCR cycles yielded an additional six full DNA profiles, resulting in an overall success rate of 79%. Overall, DNA profile success rate was not associated with the duration of storage (p = 0.387). Lastly, massively parallel sequencing with the ForenSeq™ Signature DNA Prep kit provided more informative profiles for three additional samples. These results indicate that blood should therefore remain the sample of choice in a post-mortem setting, yet buccal lysates hold potential to be optimised further, which may ease the human identification workflow.  相似文献   

8.
Abstract: Reducing amplicon sizes has become a major strategy for analyzing degraded DNA typical of forensic samples. However, amplicon sizes in current mini‐short tandem repeat‐polymerase chain reaction (PCR) and mini‐sequencing assays are still not suitable for analysis of severely degraded DNA. In this study, we present a multiplex typing method that couples ligase detection reaction with PCR that can be used to identify single nucleotide polymorphisms and small‐scale insertion/deletions in a sample of severely fragmented DNA. This method adopts thermostable ligation for allele discrimination and subsequent PCR for signal enhancement. In this study, four polymorphic loci were used to assess the ability of this technique to discriminate alleles in an artificially degraded sample of DNA with fragment sizes <100 bp. Our results showed clear allelic discrimination of single or multiple loci, suggesting that this method might aid in the analysis of extremely degraded samples in which allelic drop out of larger fragments is observed.  相似文献   

9.
Long PCR for VNTR analysis   总被引:2,自引:0,他引:2  
The Polymerase Chain Reaction (PCR) has revolutionized the analysis of DNA from a variety of sources. With its sensitivity and ability to amplify degraded DNAs and small quantities of samples, coupled with fast turn-around-time, PCR is often the analytical method of choice for DNA profiling in forensic laboratories. RFLP methods, while requiring larger amounts of high molecular weight DNA and needing approximately 6-8 weeks of analytical time, still provide a higher power of discrimination per locus than that achieved using the loci currently available for PCR. The combination of both RFLP and PCR would be advantageous for some applications. A new technique, Long PCR, allows for the effective amplification of long DNA targets from approximately 0.5 kb to > 20 kb of genomic DNA. Currently, several Long PCR systems are commercially available. Using a Taq/Pyrococcus DNA polymerase enzyme system and DNA isolated from bloodstains, we have successfully amplified 1-20 ng of Chelex-extracted DNA, an amount commonly used in Amp-FLP technology. The robustness of Long PCR in comparison to RFLP was also examined through the use of partially degraded blood samples. Long PCR was then used to amplify both D2S44 and D5S110 RFLP loci. Although all D2 and D5 alleles were detected, the larger alleles were amplified at significantly lower levels than the smaller alleles.  相似文献   

10.
目的研制适用于数据库样本荧光STR直接复合扩增体系。方法针对常规血卡、FTA和903血卡样本,配制扩增缓冲液基准母液,采用不同配方的扩增缓冲体系进行直接扩增及检测。考察不同种类增强剂、4种商业化DNA聚合酶、不同复性温度和终延伸时间对检材的检测效果,并验证优化体系的适应性。结果采用本文所建体系对各类血卡样本进行检验,均可获得样本清晰、完整的STR分型。体系选择BSA\Tween20\DMSO\甘油等增强剂组合、Typer热启动聚合酶1.5U/10μL、57~59℃复性温度、30~50min终延伸时间,采用10μL体系即可对直径1.2mm FTA卡血样进行有效分型。结论本文所研制的缓冲体系能够满足常规血卡、FTA和903血卡样本直接扩增检验的需要。  相似文献   

11.
STR profiling using hard tissues obtained from a severely decomposed body is sometimes a laborious work. There is now on a market a new DNA extraction kit, PrepFiler™ Forensic DNA Extraction Kit (AppliedBiosystems), and we tested it for missing persons. Postmortem intervals ranged from weeks to several years. Fifteen bone fragments and eleven nails were used in this report. Genomic DNA was quantified by QuantiFiler® DUO Quantification Kit (AppliedBiosystems), and STRs were analyzed using AmpFlSTR® Identifiler® PCR Amplification Kit (AppliedBiosystems). The profiling of 16 STR loci was successful in all nail samples. However, STR profiling was successful in only 6 of 15 bone materials. Nine cases failed to analyze STR polymorphisms using another DNA extraction kit, the QIAamp DNA Mini Kit (QIAGEN). For bone samples, it seems that STR profiling depends on the quality of samples.  相似文献   

12.
Disputes over the identity of a urine sample donor have been reported, and urine authentication by genetic profiling has helped resolved the cases. However, since genotyping of urine is not always required, many drug-testing laboratories may face sample storage issues. Several studies have investigated the use of FTA® cards as a convenient tool for keeping specimen at room temperature for extended periods of time. However, generating complete STR profile from some FTA®-deposited urine samples remains challenging due to low levels of genetic material content, necessitating amendments to the laboratory’s standard protocols. This work therefore aims to evaluate the effects of two DNA template preparation methods, both employing FTA® cards as the storage medium, on the success rates of STR profiling from urine. Specimen from a female volunteer, representing a particularly low-yield sample, was employed. Aliquots of 1 and 2 mL were used as the starting material to evaluate DNA template preparation using the FTA® manufacturer’s protocol for disc purification against elution of DNA from the FTA® using Prepfiler™ Forensic DNA Extraction Kit. AmpFSTR™ Identifiler™ Plus PCR Amplification Kit was used to amplify the STR markers, and the PCR products were analysed using Applied Biosystems™ 3500xL Genetic Analyzer. The DNA profile qualities were examined in terms of number of loci detected and peak height balance. Comparisons with the profiles obtained from DNA isolated using QIAamp® DNA Micro Kit from 1 and 2 mL of the same batch of urine were also made. The optimised protocol was then tested on urine samples from three male volunteers. The results showed that the purification of FTA® punches according to the manufacturer’s protocol enabled full DNA profiles to be obtained from both 1 and 2 mL of urine from all samples tested, including male samples. In contrast, no DNA profile could be generated from the DNA eluted with the Prepfiler™ kit. When compared with the more conventional solid-phase DNA extraction method, the profiles generated from the FTA® punches exhibited similar reproducibility and quality to those from the template isolated by the QIAamp® Kit. This work further demonstrated the feasibility of FTA® cards as a tool for specimen storage and DNA template preparation from small volumes of urine for authentication by STR profiling. Full STR profiles could be generated from sample from both sexes without modification of the PCR conditions or injection time.  相似文献   

13.
中国“罪犯DNA数据库”STR基因座研究   总被引:27,自引:6,他引:21  
选择合适的 STR基因座 ,建立中国“罪犯 DNA数据库”模式库。以 2 2 11名汉族、15 0名维吾尔族、10 4名回族群体为分析对象 ,提取罪犯血样 DNA,用复合 PCR和四色荧光技术检测了 D3S135 8、v WA、FGA、D8S1179、D2 1S11、D18S5 1、D5 S818、D13S317、D16 S5 39、TH0 1、TPOX、CSF1PO、D7S82 0等 13个 STR基因座及性别 Amelogenin基因座。在 13个 STR基因座中 ,除 TH0 1、TPOX基因座外 ,其余各基因座的个体鉴别能力 (DP)值均接近 0 .9,杂合度(H)均大于 0 .7,排除概率 (PE)大都在 0 .5以上 ,其中 FGA、D8S1179、D2 1S11和 D18S5 1基因座 DP≥ 0 .95 ,H≥ 0 .85 ,PE≥ 0 .6 5 ,表明它们在法医学上极有应用价值。TH0 1和 TPOX在多态性方面较差 (H分别为 0 .6 430和 0 .6 2 96 ,PE分别为0 .40 46和 0 .370 1) ,但也符合应用于法医学的要求。13个基因座的平均偶合率为 5× 10 - 1 5 ~ 1.2× l0 - 1 4 ,适合作为中国人群的遗传学标志 ,用于建立中国“罪犯 DNA数据库”  相似文献   

14.
Throughout the years, DNA barcoding has gained in importance in forensic entomology as it leads to fast and reliable species determination. High‐quality results, however, can only be achieved with a comprehensive DNA barcode reference database at hand. In collaboration with the Bavarian State Criminal Police Office, we have initiated at the Bavarian State Collection of Zoology the establishment of a reference library containing arthropods of potential forensic relevance to be used for DNA barcoding applications. CO1‐5P’ DNA barcode sequences of hundreds of arthropods were obtained via DNA extraction, PCR and Sanger Sequencing, leading to the establishment of a database containing 502 high‐quality sequences which provide coverage for 88 arthropod species. Furthermore, we demonstrate an application example of this library using it as a backbone to a high throughput sequencing analysis of arthropod bulk samples collected from human corpses, which enabled the identification of 31 different arthropod Barcode Index Numbers.  相似文献   

15.
Significant efforts are being devoted to the development of methods enabling rapid generation of short tandem repeat (STR) profiles in order to reduce turnaround times for the delivery of human identification results from biological evidence. Some of the proposed solutions are still costly and low throughput. This study describes the optimization of an analytical process enabling the generation of complete STR profiles (single‐source or mixed profiles) for human identification in approximately 5 h. This accelerated process uses currently available reagents and standard laboratory equipment. It includes a 30‐min lysis step, a 27‐min DNA extraction using the Promega Maxwell®16 System, DNA quantification in <1 h using the Qiagen Investigator® Quantiplex HYres kit, fast amplification (<26 min) of the loci included in AmpF?STR® Identifiler®, and analysis of the profiles on the 3500‐series Genetic Analyzer. This combination of fast individual steps produces high‐quality profiling results and offers a cost‐effective alternative approach to rapid DNA analysis.  相似文献   

16.
A universal method allowing for DNA profiling from bones exposed to seawater has not been reported yet. This study refers on the identification of a body immersed in seawater for 8 months. The biological material for identification was the mandibular body, usually characterized by low success rates of DNA analysis. Initially, two extraction protocols were performed with negative results: one used for bones immersed in fresh water and a silica‐column procedure. A third protocol was performed, which combined the extraction of a higher amount of bone powder, the use of multi‐silica‐based extraction columns followed by a concentration step. This protocol allowed to obtain low copy number DNA and to generate a 12‐loci STR profile by combining conventional STR typing and mini‐STR technologies. This protocol could be suitable when human bones have been exposed to severe environmental conditions, and the available nuclear DNA is highly degraded and in low copy number.  相似文献   

17.
A population study on two new short tandem repeat (STR) loci D6S477 and D19S433 was performed on 214 unrelated Italian Caucasians. The DNA was amplified by PCR and separation and detection of the amplified STR fragments were carried out by use of a PE/ABD PRISM 377 DNA sequencer 377 automated system (Applied Biosystems Division/Perkin Elmer). Both loci meet Hardy-Weinberg expectations. There is no evidence for departures from expectations between the two loci. The combined probability of discrimination and probability of exclusion for the two STR loci are 0.997161 and 0.883183, respectively. The results demonstrate that these loci can be useful for human identification in forensic cases in Italy.  相似文献   

18.
A single nucleotide polymorphism (SNP) multiplex has been developed to analyse highly degraded and low copy number (LCN) DNA template, i.e. <100 pg, for scenarios including mass disaster identification. The multiplex consists of 20 autosomal non-coding loci plus Amelogenin for sex determination, amplified in a single tube PCR reaction and visualised on the Applied Biosystems 3100 capillary electrophoresis (CE) system. Allele-specific primers tailed with shared universal tag sequences were designed to speed multiplex design and balance the amplification efficiencies of all loci through the use of a single reverse and two differentially labelled allele denoting forward universal primers. As the multiplex is intended for use with samples too degraded for conventional profiling, a computer program was specifically developed to aid interpretation. Critical factors taken into account by the software include empirically determined extremes of heterozygous imbalance (Hb) and the drop-out threshold (Ht) defined as the maximum peak height of a surviving heterozygous allele, where its partner may have dropped out. The discrimination power of the system is estimated at 1 in 4.5 million, using a White Caucasian population database. Comparisons using artificially degraded samples profiled with both the SNP multiplex and AMPFISTR SGM plus (Applied Biosystems) demonstrated a greater likelihood of obtaining a profile using SNPs for certain sample types. Saliva stains degraded for 147 days generated an 81% complete SNP profile whilst short tandem repeats (STRs) were only 18% complete; similarly blood degraded for 243 days produced full SNP profiles but only 9% with STRs. Reproducibility studies showed concordance between SNP profiles for different sample types, such as blood, saliva, semen and hairs, for the same individual, both within and between different DNA extracts.  相似文献   

19.
《Science & justice》2021,61(4):339-344
When a body is decomposed, hard tissues such as teeth may provide the only DNA source for human identification. There is currently no consensus as to the best DNA extraction method, and there is a lack of empirical data regarding tooth morphotype and condition that may impact DNA recovery. Therefore, this study sought to investigate which variables significantly improved DNA concentration, integrity and profiling success. A total of 52 human teeth were assessed, representing all tooth morphotypes from three deceased individuals. DNA was extracted using both the QIAamp® DNA Investigator Kit and the phenol-chloroform method. DNA concentration and degradation index were assessed using real time PCR, prior to conventional DNA profiling. Contrary to international guidelines promoting the use of molars, DNA profiling from molars was the least successful, with premolars, followed by canines, performing the best. The presence of fillings reduced the DNA quantity and quality obtained and may explain the poor performance of molars. DNA from the maxillae were significantly less degraded when the QIAamp® was used, although this did not influence DNA profiling success. A significant increase in DNA concentration, integrity and profiling success was observed in diseased teeth (periodontitis) compared to those without disease. This may be due to increased white blood cell presence at the site. There was no significant difference in DNA profiling success between the two DNA extraction methods. However, different teeth yielded failed DNA profiles for each extraction method, suggesting that repeated attempts, using alternative DNA extraction methods, is recommended. The recovery of additional DNA profiling information from degraded samples may help to ultimately reduce the burden of unidentified human remains.  相似文献   

20.
Autosomal short tandem repeats (STRs) have been widely used in forensic investigations. Prior to the application of any DNA based identification method, it is essential to estimate the allele frequencies and forensic statistical parameters of targeted STR loci in each population in order to provide a more precise reference database for forensic investigation. The GlobalFiler™ Kit is a multiplex assay that combines the 13 original CODIS loci with 7 non-overlapping loci from the expanded European Standard Set (ESS), as well as the highly discriminating SE33 locus, two Y-based loci and the sex determining maker, Amelogenin. The full complement of loci in the GlobalFiler™ Kit are: D13S317, D7S820, D5S818, CSF1PO, D1S1656, D12S391, D2S441, D10S1248, D18S51, FGA, D21S11, D8S1179, vWA, D16S539, TH01, D3S1358, AMEL, D2S1338, D19S433, DYS391, TPOX, D22S1045, SE33 and a Y-specific insertion/deletion locus (Yindel). The 6-dye GlobalFiler™ PCR Amplification kit (ThermoFisher Scientific) comprises 21 autosomal STRs have already been proven to be able to provide reliable DNA profiling results and enhance the power of discrimination between individuals. In this study, we are presenting an analysis of GlobalFiler STR loci on 209 unrelated individuals from Serbia.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号