首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   131篇
  免费   16篇
世界政治   2篇
外交国际关系   5篇
法律   101篇
中国共产党   1篇
中国政治   12篇
政治理论   3篇
综合类   23篇
  2023年   4篇
  2022年   4篇
  2021年   8篇
  2020年   6篇
  2019年   1篇
  2017年   5篇
  2016年   3篇
  2015年   13篇
  2014年   13篇
  2013年   9篇
  2012年   11篇
  2011年   4篇
  2010年   6篇
  2009年   10篇
  2008年   9篇
  2007年   10篇
  2006年   5篇
  2005年   6篇
  2004年   5篇
  2003年   6篇
  2002年   4篇
  2001年   2篇
  2000年   3篇
排序方式: 共有147条查询结果,搜索用时 265 毫秒
81.
Flies of the Calliphoridae Family are the most forensically important insects because of their abundance on the decedent during the first minutes following death. Necrophagous insects are attracted at a distance by a decomposing body, through the use of volatile chemical cues. We tested the possible attractive role of some volatile organic chemicals (VOCs) released by decaying cadavers, on male and female of Lucilia sericata Meigen (Diptera: Calliphoridae). Two complementary approaches were used. Electroantennography (EAG) allowed identifying the semiochemicals that are detected by the olfactory system of L. sericata. Dose-response tests with EAG showed that dimethyl disulfide (DMDS) and butan-1-ol elicited the highest responses. Behavioral assays showed that, among the VOCs tested, DMDS and butan-1-ol are attractive for L. sericata, while the other VOCs are repulsive or do not cause any behavior. Our results may have potential implications in a better understanding of attractiveness of blowflies toward a corpse.  相似文献   
82.
For the past 10 years, medical imaging techniques have been increasingly applied to forensic investigations. To obtain histological and toxicological information, tissue and liquid samples are required. In this article, we describe the development of a low-cost, secure, and reliable approach for a telematic add-on for remotely planning biopsies on the Virtobot robotic system. Data sets are encrypted and submitted over the Internet. A plugin for the OsiriX medical image viewer allows for remote planning of needle trajectories that are used for needle placement. The application of teleradiological methods to image-guided biopsy in the forensic setting has the potential to reduce costs and, in conjunction with a mobile computer tomographic scanner, allows for tissue sampling in a mass casualty situation involving nuclear, biological, or chemical agents, in a manner that minimizes the risk to involved staff.  相似文献   
83.
Conventional computed tomography is an emerging modality in forensic identification but is not sufficiently accurate for use in dental identification primarily because of problems with metallic dental restoration-induced streak artifact. In this study, the accuracy and reliability of recording forensic information from cone beam computed tomography (CBCT) scans of the jaws when compared to conventional panoramic radiographs has been analyzed under experimental conditions. Information could be recorded with near-perfect repeatability and reproducibility. Information could also be recorded accurately, the sensitivity being 96.6% (95% CI, 95.1-98.1) and specificity being 98.4% (95% CI, 96.2-100). The metal dental restoration-induced streak artifact was at a level that permitted, in most cases, accurate observations. This is considered an important step in validating CBCT as a tool in comparative dental identification of bodies. It may have a role in mass fatalities and in chemical, biological, radiological, and nuclear incidents, but further studies are required to assess the feasibility of this.  相似文献   
84.
Commercial‐off‐the‐shelf (COTS) materials were evaluated as surface samplers for the Department of Homeland Security Chemical Forensics Program. The program helps evidence collectors identify trace chemical residues at incident scenes. COTS items are widely available, produced in large lots, and with strict controls. Chemical attribution signatures were collected from common surfaces. Eight tape lift candidates were considered, five were chosen based on performance and tested for analytical interferences and extraction efficiencies with 14 chemicals. Three products (duct tape, print lifters, command strips) were evaluated for uptake from common interior surfaces (glass, tile, ABS plastic). Duct tape provided highest recoveries across all surfaces. Even the most volatile analytes were detected in the ABS plastic samples (nondetections in others), regardless of tape lift material used. The porous plastic substrate provides better target retention than glass and tile surfaces. Forensic field operators should sample surfaces made of ABS plastic (keyboards, remotes, phones, etc.) whenever possible.  相似文献   
85.
本文是根据自己多年的公安教学实践写成的。在课堂教学中,深切体会到目前公安院校课堂教学的诸多弊端:教学方法单一;部分教师的教学囿于教材面上的内容;在传授知识的过程中,忽视学生能力的培养等等。针对上述问题,提出应全面提高公安院校师资队伍素质;改革教学方法和手段;改革教学内容和课程体系等对策。  相似文献   
86.
《Science & justice》2021,61(5):635-648
A variety of suspended silica and metal nanoparticles have been used over the last 20 years to enhance latent fingermarks. This study quantitatively evaluates enhancement of natural and sebum-enriched fingermarks from three adult subjects acquired with a consistent applied force on glass with a fingermark press using suspended commercially available polystyrene (PS) particles. Images of the enhanced fingermarks acquired with total internal reflection (TIR), or standard overhead white light (WL), illumination are compared with fingermarks enhanced with conventional methods including cyanoacrylate fuming. The different enhancement and illumination methods are quantified based on the brightness and contrast of the fingermark images, as well as the number of minutiae that can be identified and matched to those on an inked manually acquired “template” fingermark using automatic fingerprint identification system (AFIS) software. Enhanced fingermarks acquired with the press are shown to be more consistent than manually acquired fingermarks based on these metrics. The results demonstrate that TIR illumination from a large-area illuminator built in house gives enhanced fingermark images with more matched minutiae and contrast superior to that for WL illumination for all types of enhancement. “Wet-powdering” with PS particles gives fingermark images that are for the most part comparable in terms of the number of matched minutiae to fingermarks enhanced with more conventional methods, suggesting that this novel enhancement method has a performance comparable to conventional enhancement methods. Interestingly, the age of the fingermark appears to have almost no effect on this new type of enhancement; sebum-enriched fingermarks ranging in age from 12 h to 435 days appear to have statistically identical numbers of matched minutiae.  相似文献   
87.
88.
The identification of gold‐bearing material is essential for combating the theft of gold in South Africa. Material seized in police operations is generally a mixture of gold from different mines, and as such cannot be traced back to a single location. ICP‐OES analysis of material dissolved by acid dissolution provided a database of gold compositions comprising gold from South African mines, illegal gold stolen from the mines, and commercial gold alloys and jewelery. Discrimination between legal and illegal gold was possible due to the presence of Pb, As, Sb, Sn, Se, and Te in the stolen material, elements which are not present in legally produced gold. The presence of these elements is a quick and simple way to distinguish between gold alloys based on refined gold, such as in commercially manufactured jewelery, and gold alloys containing a proportion of unrefined and therefore illegally obtained gold.  相似文献   
89.
Fingerprints deposited at crime scene can be a source of DNA. Previous reports on the effects of fingerprint enhancement methods have focused mainly on fingermarks deposited in blood or saliva. Here, we evaluate the effects of fingerprint enhancement methods on fingerprints deposited on porous surfaces. We performed real‐time quantification and STR typing, the results of which indicated that two methods (iodine fuming and 1,2‐indanedione in ethyl acetate enhancement) had no effect on the quantity of DNA isolated and resultant STR alleles when compared to control samples. DNA quantities and allele numbers were lower for samples enhanced with silver nitrate and 1,2‐indanedione in acetic acid when compared to control samples. Based on DNA quantity, quality, and observable stochastic effects, our data indicated that iodine fuming and 1,2‐indanedione in ethyl acetate were the preferred options for the enhancement of fingerprints on porous surfaces.  相似文献   
90.
Heroin samples, seized from the North Korean merchant vessel Pong Su in Australian waters, were analyzed to determine geographic origin. Duplicate samples were analyzed by the National Measurement Institute's Australian Forensic Drug Laboratory and the United States Drug Enforcement Administration's Special Testing and Research Laboratory. Alkaloid ratios were determined by both liquid chromatography-diode array detection (LC-DAD) and capillary electrophoresis-diode array detection (CE-DAD) techniques. Acid/neutral manufacturing by-products were determined by solvent extraction followed by gas chromatography-mass spectrometry (GC-MS). Solvents, trapped in the heroin particles during manufacture, were detected by both static headspace GC-MS and purge and trap GC-MS. The alkaloid ratios obtained were consistent with heroin of a Southeast Asian (SEA) origin and principal component analysis of the alkaloid results demonstrated the presence of at least four subgroupings within the seizure. The solvent analysis detected diethyl ether and ethyl acetate, solvents typically seen in SEA heroin. However, the acid/neutral analysis revealed compounds not normally seen in heroin of a SEA origin. Furthermore, sterol-like molecules, always detected in the acid/neutral analysis of SEA heroin, were absent from the Pong Su samples. The Pong Su heroin, although similar to SEA heroin, has sufficient differences to classify it as having an unknown origin at the time of this writing.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号