首页 | 本学科首页   官方微博 | 高级检索  
     检索      


A solid-phase microextraction method for the detection of ignitable liquids in fire debris
Authors:Yoshida Hiroaki  Kaneko Tsuyoshi  Suzuki Shinichi
Institution:National Research Institute of Police Science, Kashiwa-shi, Chiba 277-0882, Japan. yoshida@nrips.go.jp
Abstract:A solid-phase microextraction (SPME) procedure involving direct contact between the SPME fibers and the solid matrix and subsequent gas chromatography/mass spectrometric analysis for the detection of accelerants in fire debris is described. The extraction performances of six fibers (100 mum polydimethylsiloxane, 65 mum polydimethylsiloxane-divinylbenzene, 85 mum polyacrylate, 85 mum carboxen-polydimethylsiloxane, 70 mum Carbowax-divinylbenzene, and 50/30 mum divinylbenzene-Carboxen-polydimethylsiloxane) were investigated by directly immersing the fibers into gasoline, kerosene, and diesel fuel. For simulated fire debris, in the direct contact extraction method, the SPME fiber was kept in contact with the fire debris matrix during extraction by penetrating plastic bags wrapping the sample. This method gave comparable results to the headspace SPME method in the extraction of gasoline and kerosene, and gave an improved recovery of low-volatile components in the extraction of diesel fuel from fire debris. The results demonstrate that this procedure is suitable as a simple and rapid screening method for detecting ignitable liquids in fire debris packed in plastic bags.
Keywords:forensic science  arson analysis  solid-phase microextraction  ignitable liquids  accelerants  fire debris  plastic evidence bag  gas chromatography  mass spectrometry
本文献已被 PubMed 等数据库收录!