首页 | 本学科首页   官方微博 | 高级检索  
     检索      


An evaluation of the underlying mechanisms of bloodstain pattern analysis error
Authors:Behrooz Nima  Hulse-Smith Lee  Chandra Sanjeev
Institution:Department of Mechanical and Industrial Engineering, University of Toronto, 5 King's College Road, Toronto, Ontario M5S 3G8, Canada.
Abstract:An experiment was designed to explore the underlying mechanisms of blood disintegration and its subsequent effect on area of origin (AO) calculations. Blood spatter patterns were created through the controlled application of pressurized air (20-80 kPa) for 0.1 msec onto suspended blood droplets (2.7-3.2 mm diameter). The resulting disintegration process was captured using high-speed photography. Straight-line triangulation resulted in a 50% height overestimation, whereas using the lowest calculated height for each spatter pattern reduced this error to 8%. Incorporation of projectile motion resulted in a 28% height underestimation. The AO xy-coordinate was found to be very accurate with a maximum offset of only 4 mm, while AO size calculations were found to be two- to fivefold greater than expected. Subsequently, reverse triangulation analysis revealed the rotational offset for 26% of stains could not be attributed to measurement error, suggesting that some portion of error is inherent in the disintegration process.
Keywords:forensic science  bloodstain pattern analysis  fluid dynamics  blood
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏