首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Pitfalls of Computed Tomography 3D Reconstruction Models in Cranial Nonmetric Analysis*
Authors:Barbara Bertoglio MSc  PhD  Sofia Corradin MS  Annalisa Cappella MSc  PhD  Debora Mazzarelli BSc  Lucie Biehler-Gomez MSc  PhD  Carmelo Messina MD  Grazia Pozzi MD  Luca Maria Sconfienza MD  PhD  Francesco Sardanelli MD  Chiarella Sforza MD  PhD  Danilo De Angelis DDS  PhD  Cristina Cattaneo MD  PhD
Institution:1. LABANOF, Dipartimento di Scienze Biomediche per la Salute, Sezione di Medicina Legale, Università degli Studi di Milano, Via Luigi Mangiagalli 37, Milan, 20133 Italy;2. LABANOF, Dipartimento di Scienze Biomediche per la Salute, Sezione di Medicina Legale, Università degli Studi di Milano, Via Luigi Mangiagalli 37, Milan, 20133 Italy

Laboratorio di Anatomia Funzionale dell'Apparato Stomatognatico (LAFAS), Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, Via Luigi Mangiagalli 31, Milan, 20133 Italy;3. LABANOF, Dipartimento di Scienze Biomediche per la Salute, Sezione di Medicina Legale, Università degli Studi di Milano, Via Luigi Mangiagalli 37, Milan, 20133 Italy

Fondazione Isacchi Samaja ONLUS, Via Nino Bixio 30, Milan, 20129 Italy;4. IRCCS Istituto Ortopedico Galeazzi, Via Riccardo Galeazzi 4, Milan, 20161 Italy

Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, Via Luigi Mangiagalli 31, Milan, 20133 Italy;5. IRCCS Istituto Ortopedico Galeazzi, Via Riccardo Galeazzi 4, Milan, 20161 Italy;6. Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, Via Luigi Mangiagalli 31, Milan, 20133 Italy

IRCCS Policlinico San Donato, Piazza Edmondo Malan 2, Milan, 20097 Italy;7. Laboratorio di Anatomia Funzionale dell'Apparato Stomatognatico (LAFAS), Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, Via Luigi Mangiagalli 31, Milan, 20133 Italy

Abstract:Many studies in the literature have highlighted the utility of virtual 3D databanks as a substitute for real skeletal collections and the important application of radiological records in personal identification. However, none have investigated the accuracy of virtual material compared to skeletal remains in nonmetric variant analysis using 3D models. The present study investigates the accuracy of 20 computed tomography (CT) 3D reconstruction models compared to the real crania, focusing on the quality of the reproduction of the real crania and the possibility to detect 29 dental/cranial morphological variations in 3D images. An interobserver analysis was performed to evaluate trait identification, number, position, and shape. Results demonstrate a false bone loss in 3D models in some cranial regions, specifically the maxillary and occipital bones in 85% and 20% of the samples. Additional analyses revealed several difficulties in the detection of cranial nonmetric traits in 3D models, resulting in incorrect identification in circa 70% of the traits. In particular, pitfalls included the detection of erroneous position, error in presence/absence rates, in number, and in shape. The lowest percentages of correct evaluations were found in traits localized in the lateral side of the cranium and for the infraorbital suture, mastoid foramen, and crenulation. The present study highlights important pitfalls in CT scan when compared with the real crania for nonmetric analysis. This may have crucial consequences in cases where 3D databanks are used as a source of reference population data for nonmetric traits and pathologies and during bone-CT comparisons for identification purposes.
Keywords:nonmetric traits  computed tomography  CT accuracy  anatomical variants  cranial traits  forensic anthropology
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号