首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Fluorat-02-3M liquid analyzer essentially extends the range of hemoglobin measurements, increasing its concentration in the studied extract from 0.1 to 100 micrograms in a 100 microliters sample (the lower threshold concentration remains unchanged: 0.005 in a 100-microliters sample) in detection of the blood in stains on material evidence pieces by fluorescent hemotest. This allows detection of blood in both washed and clearly seen blood stains on pieces of material evidence. Examples of using this method for measuring mass concentrations of zinc in water extracts on a Fluorat-02-3M analyzer are presented. The analyzer was developed at the Bureau of Forensic Medical Expert Evaluations of the Leningrad region for tentative detection of seminal fluid in stains on material evidence pieces. The results of this method are objectively recorded.  相似文献   

2.
Russian and foreign methods used in forensic medicine for detection of the semen in stains on material evidences are compared. The potentialities of quantitative immunofluorescence test for detection of the semen in stains on material evidences, developed at Bureau for Forensic Medical Expert Evaluations of the Leningrad region, are described. Unlike other methods used in Russia, this method detects the semen in stains in the absence of spermatozoa and in stains with very low amount of the semen. Our modification allows objective recording of the results with computer processing. The method is cheaper than its foreign analogs and its sensitivity is similar to them.  相似文献   

3.
The authors give the comparative analysis of Russian and foreign forensic medical methods of species character identification of the blood from the stains on the material evidences and bone fragments. It is shown that for this purpose it is feasible to apply human immunoglobulin G (IgG) and solid phase enzyme immunoassay (EIA) with the kit "IgG general-EIA-BEST". In comparison with the methods used in Russia this method is more sensitive, convenient for objective registration and computer processing. The results of experiments shown that it is possible to use the kit "IgG general-EIA-BEST" in forensic medicine for the species character identification of the blood from the stains on the material evidences and bone fragments.  相似文献   

4.
A quantitative modification of immunofluorescent test (IFT) is described. It was used for species identification of blood stains on material evidence objects. This modification is 1000 times more sensitive than electrophoretic methods traditionally used for this purpose in forensic medicine. Computer processing of the results helps objectively and persuasively determine the species appurtenance of blood and other biological objects. Results of the test represented as histograms should be attached to forensic medical conclusions as proofs for the court.  相似文献   

5.
The objective of the present study was to evaluate sensitivity and specificity of the HemDirect method on test-plates (Seratec) for detecting human hemoglobin (HHb). These characteristics were compared with those of other widely used methods designed for the detection of blood traces, viz. thin layer chromatography, hemotest, spectrofluorimetry, and identification of blood species specificity (by countercurrent immunoelectrophoresis in agar and on the acetate-cellulose film). It was shown that the HemDirect test is highly specific and far more sensitive than other techniques used for the same purpose in the practical work. It can be recommended as the method of choice for the detection of blood microtraces.  相似文献   

6.
Blood stains on a knife were identified by DNA genotyposcopy. The statistical validation method has confirmed that the blood stains on material evidence belonged to the victim, the probability of random coincidence being less than 10(-11). The efficacy of using hypervariable locus-specific DNA probes and the possibility of detecting DNA impressions in blood stains stored for more than 3 months have been demonstrated.  相似文献   

7.
Quantitative analysis of serum proteins in blood stains by rocket immunoelectrophoresis showed the following results: Long elution times in processing blood stains do not produce a significantly higher yield of serum proteins in stains, and they increase the risk of structural alteration of protein molecules. The amount of proteins detected decreases with increasing age of blood stains. Some proteins are already altered in stains after a short storage time and are no longer useful for phenotyping. Our results confirm that blood stain material should be processed as soon as possible.  相似文献   

8.
《Science & justice》2014,54(6):432-438
Current methods of detection and identification of blood stains rely largely on visual examination followed by presumptive tests such as Kastle–Meyer, Leuco-malachite green or luminol. Although these tests are useful, they can produce false positives and can also have a negative impact on subsequent DNA tests. A novel application of visible wavelength reflectance hyperspectral imaging has been used for the detection and positive identification of blood stains in a non contact and non destructive manner on a range of coloured substrates. The identification of blood staining was based on the unique visible absorption spectrum of haemoglobin between 400 and 500 nm. Images illustrating successful discrimination of blood stains from nine red substances are included. It has also been possible to distinguish between blood and approximately 40 other reddish stains. The technique was also successfully used to detect latent blood stains deposited on white filter paper at dilutions of up to 1 in 512 folds and on red tissue at dilutions of up to 1 in 32 folds. Finally, in a blind trial, the method successfully detected and identified a total of 9 blood stains on a red T-shirt.  相似文献   

9.
Presumptive tests for blood are very simple and sensitive tests used in the search for evidence. They also provide initial information on the nature of stains. A second test can confirm their nature. However, these tests can present false–negative results for different reasons. Some of those reasons have been studied, while others, those caused by the substrate material that contains the stain, are less well known. This work studies the effect of one component of a leather substrate—quebracho extract—on presumptive and human hemoglobin blood tests. Assays were performed using samples of blood dilutions contaminated with quebracho extract and others formed on a substrate containing the contaminant. Results show an undoubted interference that causes false negatives and even visible to the naked eye stains and also indicate that some tests (phenolphthalein) are more affected than others. Examiners should be taken into account when working on this kind of substrates.  相似文献   

10.
A method for simultaneous detection and identification of the blood in stains on material evidence has been tried. Previously these two procedures were carried out in succession and took 2 days, while the new method takes 2-10 min. The method is highly sensitive and specific. Positive results were obtained only with human blood. The method is recommended for practice, specifically, for investigation of complex blood traces (washed and old) on material evidence.  相似文献   

11.
The performance of typing group-specific component (Gc) in bloodstains by two isoelectric focusing methods followed by its detection with silver staining has been compared with an established forensic system of typing phosphoglucomutase (PGM1) locus phenotypes by isoelectric focusing (IEF) in 1 mm gels. For Gc typing ultra-thin isoelectric focusing (UTIEF) gels and immobilized pH gradient (IPG) gels were used. Both laboratory prepared stains and casework stains were examined. The Gc UTIEF method is approximately eight times more sensitive than the existing PGM1 1 mm IEF method for control and casework stains. However, on average, a larger amount of stain was taken from casework stains than control stains for each typing system. A total of 53 casework stains were examined. Comparable success rates of 62% and 64% were obtained for typing Gc on UTIEF gels and PGM1 by 1 mm IEF, respectively. A success rate of 55% was obtained for typing Gc on IPGs. Bloodstains that were over 200 days old were successfully grouped by all three methods.  相似文献   

12.
A sensitive microplate hemagglutination-inhibition technique has been used to ascertain the distributions of secreted blood group substances (BGS) in a population of 176 semen specimens and to characterize the stability of these substances in dried semen stains. The BGS concentrations in semen were found to vary throughout a wide range of titer. Despite this latitude of variation, the titers for the component BGS within the blood groups could be described by a log-normal distribution function. Studies of a number of sequential semen specimens obtained from the same donors revealed that the intraindividual variation in BGS titers was much more limited than the interindividual BGS titers. Attempts to correlate variations in titers between A and H in Group A semen or B and H in Group B semen indicated that the levels of these component substances vary independently. Studies of the stability of BGS in Groups A and O semen suggested that these substances were stable when the semen stains were stored at -20 degrees C, 4 degrees C, or at ambient laboratory temperature in a dry state. In contrast, stains stored at 37 degrees C under humid conditions suffered a dramatic loss in BGS titer, with the half-life of the BGS being on the order of 30 days.  相似文献   

13.
A novel method for the non-destructive age determination of a blood stain is described. It is based on the measurement of the visible reflectance spectrum of the haemoglobin component using a microspectrophotometer (MSP), spectral pre-processing and the application of supervised statistical classification techniques. The reflectance spectra of sample equine blood stains deposited on a glazed white tile were recorded between 1 and 37 days, using an MSP at wavelengths between 442 nm and 585 nm, under controlled conditions. The determination of age was based on the progressive change of the spectra with the aging of the blood stain. These spectra were pre-processed to reduce the effects of baseline variations and sample scattering. Two feature selection methods based on calculation of Fisher's weights and Fourier transform (FT) of spectra were used to create inputs into a statistical model based on linear discriminant analysis (LDA). This was used to predict the age of the blood stain and tested by using the leave-one-out cross validation method. When the same blood stain was used to create the training and test datasets an excellent correct classification rate (CCR) of 91.5% was obtained for 20 input frequencies, improving to 99.2% for 66 input frequencies. A more realistic scenario where separate blood stains were used for the training and test datasets led to poorer successful classification due to problems with the choice of substrate but nevertheless up to 19 days a CCR of 54.7% with an average error of 0.71 days was obtained.  相似文献   

14.
Blood detection and identification at crime scenes are crucial for harvesting forensic evidence. Unfortunately, most tests for the identification of blood are destructive and time consuming. We present a fast and nondestructive identification test for blood, using noncontact reflectance spectroscopy. We fitted reflectance spectra of 40 bloodstains and 35 nonbloodstains deposited on white cotton with spectroscopic features of the main compounds of blood. Each bloodstain was measured 30 times to account for aging effects. The outcome of the blood measurements was compared with the reflectance of blood-mimicking stains and various body fluids. We found that discrimination between blood and nonblood deposited on white cotton is possible with a specificity of 100% and a sensitivity of 98%. In conclusion, a goodness of fit between the sample's reflectance and the blood component fit may allow identification of blood at crime scenes by remote spectroscopy.  相似文献   

15.
The survival of human proteins in blood stains on fragments of cloth buried in exposed soil was examined in a 15-month investigation carried out from September 1990 to December 1991. During this period there was a wide variety of weather conditions. Samples were exhumed at 4-weekly intervals for 16 weeks and finally at 65 weeks; extracts of the stains were tested for albumin and IgG using a highly specific and sensitive enzyme-linked immunosorbent assay (ELISA) performed with monoclonal antibodies. Human albumin survived well throughout the 15 months of study, but IgG could be detected only in the 4- and 8-week samples. The reactions for IgG were weaker than those for albumin, although the method's sensitivity (10 ng) was the same for each protein. Appropriate buried and non-buried control experiments were carried out using cloth, either unstained or stained with human blood or animal sera; there was no cross-reactivity between human and the other species investigated and soil did not affect the assay; under laboratory conditions, IgG and albumin survived equally well. The system's versatility was illustrated by using monoclonal anti-bovine-albumin to detect specific albumin in the extracts of buried cloth which has been stained with bovine serum. It was concluded that ELISA performed with monoclonal antibodies could be of great value in identifying blood stains for forensic purposes.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

16.
Trying to optimize the preparation of blood stains, we found methanol fixation not to produce very good results for the determination of ABO blood group antigens. It is advantageous to transfer blood stains before testing to cotton cloth. This transfer is also of practical use if blood stains are to be saved on a smooth surface for lateral determination. We testet on 35 different carrier materials, on which blood stains in casework often were found, whether blood grouping gave better results on either the original material or after transfer. Results are shown on a table. The test revealed, that solubility of the stain in aqua dest is a good sign for a successful transfer. Blood stains on pine-wood soil, soil and loam were not suited for ABO grouping.  相似文献   

17.
Blood, saliva and semen are some of the forensically most relevant biological stains found at crime scenes. mRNA profiling is a reliable approach for the identification of the origin of an evidentiary trace. A stable set of markers and the knowledge about the effects of RNA degradation under different environmental conditions is necessary for the determination of an unknown biological stain. The aim of this work was to compare RNA degradation for human blood, semen and saliva at three different concentrations during a 1-year time period and exposed to dry and humid conditions. Also, this study addressed the question whether there are relevant differences in the efficiency of two RNA extraction methods.  相似文献   

18.
Liquid blood and blood stains were examined after storage under different conditions and temperature regimes ranging from 18 to 26 degrees C. Blood stains were washed by distilled water or heated to 120 degrees C for as long as 4 hours. Then, blood groups were determined by absorption-elution.  相似文献   

19.
Biological stains can be difficult to detect at crime scenes or on items recovered from crime scenes. The use of a versatile light source may assist in their detection. The ability of Polilight to locate potential semen, saliva, and blood stains on a range of substrates and at different dilutions was tested. We also tested the use of Polilight in comparison with conventional chemical-based presumptive screening tests such as acid phosphatase (AP), Phadebas, and luminol, often used in casework for detecting potential semen, saliva, and blood stains, respectively. The Polilight was able to locate stains that were not apparent to the naked eye. The color of the material on which a stain is deposited can have an effect on the detectibility of the stain. The Polilight was found to be comparable with the AP and Phadebas tests in terms of its sensitivity. In a comparative study between the AP test and Polilight on 40 casework exhibits, one false-negative result was observed when using the Polilight. On a series of mock casework exhibits it was determined that the Polilight can be used successfully to locate saliva stains for DNA analysis. The sensitivity of luminol for detecting potential bloodstains was greater than that of Polilight; however the Polilight has particular application in instances where a bloodstain may have been concealed with paint. Overall, the Polilight is a relatively safe, simple, noninvasive, and nondestructive technique suitable for use in forensic casework.  相似文献   

20.
A new method for the detection of minor C, Cw, c, E, e-antigens of the Rhesus system in blood stains has been developed based on the absorption-elution technique with the use of anti-C, anti-Cw, anti-c, anti-E, and anti-e sera and standard erythrocyte preparations preliminarily treated with highly active proteases (protease C or papain). This method makes it possible to determine complete Rhesus phenotype in blood stains and substantially extend the possibilities of their differentiation on material objects (evidence) for the purpose of forensic-biological examination.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号