共查询到9条相似文献,搜索用时 0 毫秒
1.
Andrzej Olejniczak M.Sc. Aleksandra W. Cyganiuk M.Sc. Jerzy P. Lukaszewicz Ph.D. 《Journal of forensic sciences》2010,55(3):747-752
Abstract: This article extends the application of 1,2,4‐triazine‐based chromogenic reagents to the detection of nonferrous metal traces left on contact with canvas and human skin. The possibility of detection of iron traces resulting from contact with objects made of stainless steel was investigated as well. Additionally, the ability of triazines to form chromatic complexes with Zn2+, Ni2+, Co2+, Cu2+, Cr3+, and Al3+ ions was studied spectrophotometrically. Molar absorption coefficients, ranging from 8.8 to 29.9 × 103/M/cm, provide high sensitivity of 1,2,4‐triazines toward nonferrous ions, thus, enabling the detection at concentrations as low as a few μM. The method was sensitive enough to detect traces resulting from a 1‐min contact with a stainless steel made object, which is commonly considered as a corrosion‐resistant material. The amounts of metal ions transferred to the skin after a 2‐min contact with objects made of brass, zinc, and copper were sufficient to develop chromatic imprints. 相似文献
2.
Eckenrode BA Ramsey SA Stockham RA Van Berkel GJ Asano KG Wolf DA 《Journal of forensic sciences》2006,51(4):780-789
The Scent Transfer Unit (STU-100) is a portable vacuum that uses airflow through a sterile gauze pad to capture a volatiles profile over evidentiary items for subsequent canine presentation to assist law enforcement personnel. This device was evaluated to determine its ability to trap and release organic compounds at ambient temperature under controlled laboratory conditions. Gas chromatography-mass spectrometry (GC-MS) analyses using a five-component volatiles mixture in methanol injected directly into a capture pad indicated that compound release could be detected initially and 3 days after the time of collection. Additionally, 15 compounds of a 39-component toxic organic gaseous mixture (10-1000 parts per billion by volume [p.p.b.(v)]) were trapped, released, and detected in the headspace of a volatiles capture pad after being exposed to this mixture using the STU-100 with analysis via GC-MS. Component release efficiencies at ambient temperature varied with the analyte; however, typical values of c. 10% were obtained. Desorption at elevated temperatures of reported human odor/scent chemicals and colognes trapped by the STU-100 pads was measured and indicated that the STU-100 has a significant trapping efficiency at ambient temperature. Multivariate statistical analysis of subsequent mass spectral patterns was also performed. 相似文献
3.
Abstract: Most thermosensitive surfaces of thermal paper turn black when they come into contact with polar organic solvents such as are used in ninhydrin petroleum benzin solution. This dark staining reduces the contrast between the developed fingerprint and the background to such an extent that the identification process becomes very difficult. Integrating polyvinylpyrrolidones (PVP) into a ninhydrin solution prevents the black staining, and the developed fingerprints appear in clear contrast to the background. The new ninhydrin solution containing PVP is successful compared to the two‐step ninhydrin–acetone washing method for thermal paper which is popular in Germany. 相似文献
4.
Matan Shelomi B.S. Leia M. Matern B.S. Jenna M. Dinstell Daren W. Harris Robert B. Kimsey Ph.D. 《Journal of forensic sciences》2012,57(6):1507-1511
Abstract: The question of whether the insect repellent N,N‐Diethyl‐meta‐toluamide (DEET) affected fly attraction, oviposition, and larval development was investigated; in part, to determine whether the common habit of wearing DEET as a repellent could affect the rate of human decomposition. Experiments using pig surrogates of human decedents were carried out in a rural environment. Dead piglets were sprayed with DEET, and fly behavior, colonization levels, and maggot development were compared with those in nonsprayed controls. Piglets treated with DEET experienced significant delays in fly visitation and oviposition and delayed appearance of each larval instar, as well as reduced total larval numbers (p < 0.01 for all variables), with subsequently reduced decomposition (p < 0.05). Such changes in fly behavior and larval population development would significantly impact the estimation of the period following the death from entomological evidence in decedents wearing DEET at the time of their death. 相似文献
5.
This paper describes a procedure for the determination of psilocin and psilocybin in mushroom extracts using high-performance liquid chromatography with postcolumn chemiluminescence detection. A number of extraction methods for psilocin and psilocybin in hallucinogenic mushrooms were investigated, with a simple methanolic extraction being found to be most effective. Psilocin and psilocybin were extracted from a variety of hallucinogenic mushrooms using methanol. The analytes were separated on a C12 column using a (95:5% v/v) methanol:10 mM ammonium formate, pH 3.5 mobile phase with a run time of 5 min. Detection was realized through a dual reagent chemiluminescence detection system of acidic potassium permanganate and tris(2,2'-bipyridyl)ruthenium(II). The chemiluminescence detection system gave improved detectability when compared with UV absorption at 269 nm, with detection limits of 1.2 x 10(-8) and 3.5 x 10(-9) mol/L being obtained for psilocin and psilocybin, respectively. The procedure was applied to the determination of psilocin and psilocybin in three Australian species of hallucinogenic mushroom. 相似文献
6.
7.
James H. Watterson Ph.D. D.A.B.F.T. Jolina E. Botman B.Sc. 《Journal of forensic sciences》2009,54(3):708-714
Abstract: Enzyme‐linked immunosorbent assay (ELISA) and liquid chromatography tandem mass spectrometry (LC/MS/MS) were used to detect diazepam exposure in skeletal tissues of rats (n = 15) given diazepam acutely (20 mg/kg, i.p.), and killed at various times postdose. Marrow, epiphyseal, and diaphyseal bone were isolated from extracted femora. Bone was cleaned, ground, and incubated in methanol. Marrow underwent ultrasonic homogenization. Extracts and homogenates were diluted in phosphate buffer, and then underwent solid‐phase extraction and ELISA. Relative sensitivity of detection was examined in terms of relative decrease in absorbance (ELISA) and binary classification sensitivity (ELISA and LC/MS/MS). Overall, the data showed differences in relative sensitivity of detection of diazepam exposure in different tissue types (marrow > epiphyseal bone > diaphyseal bone), which is suggestive of heterogenous distribution in these tissues, and a decreasing sensitivity with increasing dose‐death interval. Thus, the tissue type sampled and dose‐death interval may contribute to the probability of detection of diazepam exposure in skeletal tissues. 相似文献
8.
9.
Charles W. Beason M.S. James R. Jauchem Ph.D. C. D. Clark III B.S. James E. Parker M.S. David A. Fines B.S. 《Journal of forensic sciences》2009,54(5):1113-1118
Abstract: Conducted energy weapons (such as the Advanced TASER X26 model produced by TASER International), incapacitate individuals by causing muscle contractions. To provide information relevant to development of future potential devices, a “Modifiable Electronic Stimulator” was used to evaluate the effects of changing various parameters of the stimulating pulse. Muscle contraction was affected by pulse power, net/gross charge, pulse duration, and pulse repetition frequency. The contraction force increased linearly as each of these factors was increased. Elimination of a precursor pulse from X26‐like pulses did not have a significant effect on the normalized force measured. Muscle‐contraction force increased as the spacing increased from 5 to 20 cm, with no further change in force above 20 cm of spacing. Therefore, it is suggested that any future developments of new conducted energy weapons should include placement of electrodes a minimum of 20 cm apart so that efficiency of the system is not degraded. In the current study, the 50% probability of fibrillation level of X26‐like pulses ranged from 4 to 5 times higher than the X26 itself. Relatively large variations about the X26 operating level were found not to result in fibrillation or asystole. Therefore, it should be possible to design and build an X26‐type device that operates efficiently at levels higher than the X26. 相似文献