首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Abstract: Multiplex autosomal short tandem repeat (STR) genotyping enables researchers to obtain genetic information from ancient human samples. In this study, we tested newly developed AmpF?STR® MiniFiler? kit for autosomal STR analysis of ancient DNA (aDNA), using human femurs (n = 8) collected from medieval Korean tombs. After extracting aDNA from the bones, autosomal STR analyses were repeated for each sample using the AmpF?STR® MiniFiler? and Identifiler? kits. Whereas only 21.87% of larger‐sized loci profiles could be obtained with the Identifiler? kit, 75% of the same loci profiles were determined by MiniFiler? kit analysis. This very successful amplification of large‐sized STR markers from highly degraded aDNA suggests that the MiniFiler? kit could be a useful complement to conventional STR kit analysis of ancient samples.  相似文献   

2.
Abstract: A sexual assault case resulted in a pregnancy, which was subsequently aborted. The alleged father of the fetus was unknown. Maternal and fetal types were obtained using the 11‐locus AmpF?STR® SGM Plus® kit. The national DNA database was searched for the paternal obligatory alleles and detected two suspects who could not be excluded as father of the male fetus. Additional typing using the AmpF?STR® Minifiler? kit, containing three additional autosomal loci, was not sufficient to exclude either suspect. Subsequent typing using the PowerPlex® 16, containing four additional loci, and Y‐Filer? kits resulted in excluding one suspect. Searching a database for paternal obligatory alleles can be fruitful, but is fraught with possible false positive results so that finding a match must be taken as only preliminary evidence.  相似文献   

3.
Abstract: Analysis of length polymorphism at short tandem repeat (STR) loci utilizing multiplex polymerase chain reaction (PCR) remains the primary method for genotyping forensic samples. The AmpF?STR® Identifiler® Plus PCR Amplification Kit is an improved version of the AmpF?STR® Identifiler® PCR Amplification Kit and amplifies the core CODIS loci: D3S1358, D5S818, D7S820, D8S1179, D13S317, D16S539, D18S51, D21S11, CSF1PO, FGA, TH01, TPOX, and vWA. Additional loci amplified in the multiplex reaction are the sex‐determinant, amelogenin, and two internationally accepted loci, D2S1338 and D19S433. While the primer sequences and dye configurations were unchanged, the AmpF?STR® Identifiler® Plus PCR Amplification Kit features an enhanced buffer formulation and an optimized PCR cycling protocol that increases sensitivity, provides better tolerance to PCR inhibitors, and improves performance on mixture samples. The AmpF?STR® Identifiler® Plus PCR Amplification Kit has been validated according to the FBI/National Standards and Scientific Working Group on DNA Analysis Methods (SWGDAM) guidelines. The validation results support the use of the AmpF?STR® Identifiler® Plus PCR Amplification Kit for human identity and parentage testing.  相似文献   

4.
Significant efforts are being devoted to the development of methods enabling rapid generation of short tandem repeat (STR) profiles in order to reduce turnaround times for the delivery of human identification results from biological evidence. Some of the proposed solutions are still costly and low throughput. This study describes the optimization of an analytical process enabling the generation of complete STR profiles (single‐source or mixed profiles) for human identification in approximately 5 h. This accelerated process uses currently available reagents and standard laboratory equipment. It includes a 30‐min lysis step, a 27‐min DNA extraction using the Promega Maxwell®16 System, DNA quantification in <1 h using the Qiagen Investigator® Quantiplex HYres kit, fast amplification (<26 min) of the loci included in AmpF?STR® Identifiler®, and analysis of the profiles on the 3500‐series Genetic Analyzer. This combination of fast individual steps produces high‐quality profiling results and offers a cost‐effective alternative approach to rapid DNA analysis.  相似文献   

5.
Abstract: The Quantifiler® Duo DNA Quantification kit enables simultaneous quantification of human DNA and human male DNA as well as detection of inhibitors of PCR in a single real-time PCR well. Pooled human male genomic DNA is used to generate standard curves for both human (ribonuclease P RNA component H1) and human male (sex determining region Y) specific targets. A shift in the cycle threshold (CT) values for the internal positive control monitors the presence of PCR inhibitors in a sample. The assay is human specific and exhibits a high dynamic range from 0.023 to 50 ng/μL. In addition, the multiplex assay can detect as little as 25 pg/μL of human male DNA in the presence of a 1000-fold excess of human female DNA. The multiplex assay provides assessment of the DNA extract and guidance for the selection of the appropriate AmpFℓSTR® Amplification Kit to obtain interpretable short tandem repeat profiles.  相似文献   

6.
7.
Abstract: The AmpF?STR® Identifiler® Direct PCR Amplification Kit is a new short tandem repeat multiplex assay optimized to allow the direct amplification of single‐source blood and buccal samples on FTA® card without the need for sample purification and quantification. This multiplex assay has been validated according to the FBI/National Standards and SWGDAM guidelines. Validation results revealed that slight variations in primer concentration, master mix component concentration, and thermal cycling parameters did not affect the performance of the chemistry. The assay’s sensitivity was demonstrated by amplifying known amounts of white blood cells spotted onto FTA® cards, and the assay’s specificity was verified by establishing minimal cross‐reactivity with nonhuman DNA. No effect on the age of the sample stored on the FTA® substrate was observed and full concordance was established in the population study. These findings of the validation study support the use of the Identifiler® Direct Kit for forensic standards and database samples genotyping.  相似文献   

8.
In this study, DNA was extracted using an AutoMate Express? and an EZ1 Advanced XL from liquid blood, fresh and aged bloodstains, and fresh and aged semen stains. Extracted DNA was quantified by real‐time PCR using the D17Z1 locus. Short tandem repeat typing was performed using an AmpF?STR® Identifiler kit. The yields of DNA obtained by the AutoMate Express? were higher from fresh bloodstains and fresh semen stains, almost the same from aged bloodstains and aged semen stains, but slightly lower from liquid blood compared with those obtained by the EZ1 Advanced XL. The addition of dithiothreitol or the use of PrepFiler? lysis buffer improved the EZ1 Advanced XL results from fresh bloodstains, but not for liquid blood and aged bloodstains. Our results demonstrated that the PrepFiler? lysis buffer is the main contributor to the higher DNA yields of the AutoM ate Express? for fresh bloodstains.  相似文献   

9.
Abstract: Archived slides of cell smears treated with histological stains for sperm detection are often the only source of DNA available when cold cases are reopened. There have been conflicting reports as to the negative effects of particular histological stains on DNA recovery and quality from human cells, making stain selection an important consideration for forensic laboratories. This study investigates the effect of several staining systems on DNA recovery from histological slide samples stored from 0 to 10 weeks. DNA profiles obtained after analysis of these samples with AmpFlSTR® Identifiler? and increased cycle AmpFlSTR® SGM Plus? short tandem repeat (STR) profiling systems and the effects that these stains have on DNA quantity and quality over time are described. Results indicate that Christmas Tree and Hematoxylin and Eosin stains do not have significantly different effects on DNA quality after 10‐week storage of slides. This research will assist scientists to select staining systems that have minimal deleterious effects on the DNA recovered.  相似文献   

10.
Qiagen's Investigator? Quantiplex kit, a total human DNA quantitation kit, has a 200‐base pair internal control, fast cycling time, and scorpion molecules containing a covalently linked primer, probe, fluorophore, and quencher. The Investigator? Quantiplex kit was evaluated to investigate a value under which complete short tandem repeat (STR) failure was consistently obtained. Buccal swabs were extracted using the Qiagen QIAamp® DNA Blood Mini Kit, quantified with the Investigator? Quantiplex kit using a tested half‐volume reaction, amplified with the ABI AmpFlSTR® Identifiler kit, separated on the 3100Avant Genetic Analyzer, and data analyzed with GeneMapper® ID v.3.2. While undetected samples were unlikely to produce sufficient data for statistical calculations or CODIS upload (2.00 alleles and 0.82 complete loci on average), data may be useful for exclusionary purposes. Thus, the Investigator? Quantiplex kit may be useful for predicting STR success. These findings are comparable with previously reported data from the Quantifiler? Human kit.  相似文献   

11.
About 120,000 reference samples are analyzed each year in the Forensic Laboratory of Lyon. A total of 1640 positive control experiments used to validate and optimize the analytical method in the routine process were submitted to a multivariate exploratory data analysis approach with the aim of better understanding the underlying sources of variability. The peak heights of the 16 genetic markers targeted by the AmpF?STR® Identifiler® STR kit were used as variables of interest. Six different 3130xl genetic analyzers located in the same controlled environment were involved. Two major sources of variability were found: (i) the DNA load of the sample modulates all peak heights in a similar way so that the 16 markers are highly correlated, (ii) the genetic analyzer used with a locus‐specific response for peak height and a better sensitivity for the most recently acquired. Three markers (FGA, D3S1358, and D13S317) were found to be of special interest to predict the success rate observed in the routine process.  相似文献   

12.
European forensic laboratories are replacing the STR multiplex kits with the new generation 16/17 STR kits. This study examines the influence of the new generation kits and the new Applied Biosystems 3500xL Genetic Analyzer on the designation of long D2S1338 and D19S433 off‐ladder alleles. Different allele calls were obtained using the new NGM? (Applied Biosystems) and PowerPlex® ESI? (Promega) kits compared with AmpF?STR® SGM Plus? kit (Applied Biosystems). Sequence analysis was used to determine accurate allele designation. The new multiplex kits and the 3500xL Genetic Analyzer improved accuracy of long allele designations. DNA databases worldwide include countless profiles obtained by previous kits. Discrepancies between the new and former technologies may cause failure to detect hits. Discordance is expected due to primer sequence differences between various kits. An additional discordance, occurring in long alleles, independent of primer sequence is reported in this study.  相似文献   

13.
Forensic anthropologists use a number of maceration techniques to facilitate skeletal analysis of personal identity and trauma, but they may unwittingly eliminate valuable DNA evidence in the process. This study evaluated the effect of 10 maceration methods on gross bone structure and the preservation of DNA in ribs of 12 pigs (Sus scrofa). A scoring system was applied to evaluate the ease of maceration and resulting bone quality while DNA purity was quantified by optical densitometry analysis, followed by polymerase chain reaction (PCR) amplification of three mitochondrial and three nuclear loci. The results demonstrated that while mitochondrial DNA could be amplified for all experiments, cleaning treatments using bleach, hydrogen peroxide, ethylenediaminetetraacetic acid/papain, room temperature water and detergent/sodium carbonate followed by degreasing had low DNA concentrations and failed to generate nuclear PCR products. In general, treatments performed at high temperatures (90 degrees C or above) for short durations performed best. This study shows that traditionally "conservative" maceration techniques are not necessarily the best methods to yield DNA from skeletal tissue.  相似文献   

14.
Calcified tissues, such as bone and tooth, and some other sample types, such as those containing adhesive, present a challenge to standard extraction protocols. We have developed a lysis reagent, BTA™ lysis buffer, which is designed for use with PrepFiler™ Kit reagents. The BTA™ lysis buffer disrupts calcified tissue matrices and achieves effective extraction of DNA from pulverized bone and tooth samples. In addition, the BTA™ lysis buffer mildly but efficiently extracts DNA from challenging substrates like tape, chewing gum, and cigarette butts and, as with bone and tooth, DNA from these lysates is purified using established PrepFiler™ reagent extraction protocols.We successfully extracted DNA from powdered human bone samples, chewed gum and smoked cigarettes using BTA™ lysis buffer. Extraction yields for bone, gum and cigarette samples tested were consistent and reproducible. This extraction method efficiently removed potential PCR inhibitors from all samples tested, and CT values for the internal PCR control of Quantifiler® Human DNA Quantification Kit were consistent and within the normal range. The DNA extracted from these samples also provided conclusive profiles that were free of PCR artifacts when amplified using the AmpF?STR® Identifiler® PCR Amplification Kit. The protocol is easily adapted for automation.  相似文献   

15.
Abstract: The quality and efficiency of a standard organic DNA isolation method and a silica‐based method using the QIAGEN Blood Maxi Kit were compared to obtain human DNA and short tandem repeats (STRs) profiles from 39 exhumed bone samples for paternity testing. DNA samples were quantified by real‐time PCR, and STR profiles were obtained using the AmpFlSTR® Identifiler® PCR amplification kit. Overall, the silica‐based method recovered less DNA ranging from 0 to 147.7 ng/g (average 7.57 ng/g, median = 1.3 ng/g) than did the organic method ranging from 0 to 605 ng/g (average 44.27 ng/g, median = 5.8 ng/g). Complete profiles (16/16 loci tested) were obtained from 37/39 samples (95%) using the organic method and from 9/39 samples (23%) with the silica‐based method. Compared with a standard organic DNA isolation method, our results indicate that the published silica‐based method does not improve neither the quality nor the quantity of DNA for STR profiling.  相似文献   

16.
We have implemented and validated customized protocols for automated Quantifiler® setup, template normalization and PCR setup using the Tecan HID EVOlution™ qPCR/STR setup. The protocols were validated for the Quantifiler® human DNA quantification, AmpF?STR® SGM Plus® and SEfiler Plus™ PCR Amplification Kits (Applied Biosystems) according to EN/ISO 17025.  相似文献   

17.
We have validated and implemented a protocol for DNA extraction from various types of biological materials using a Qiagen BioRobot EZ1 Workstation. The sample materials included whole blood, blood from deceased, buccal cells on Omni swabs and FTA Cards, blood on FTA Cards and cotton swabs, and muscle biopsies. The DNA extraction was validated according to EN/ISO 17025 for the STR kits AmpF?STR® Identifiler® and AmpF?STR® Yfiler® (Applied Biosystems). Of 298 samples extracted, 11 (4%) did not yield acceptable results. In conclusion, we have demonstrated that extraction of DNA from various types of biological material can be performed quickly and without the use of hazardous chemicals, and that the DNA may be successfully STR typed according to the requirements of forensic genetic investigations accredited according to EN/ISO 17025.  相似文献   

18.
Abstract: This paper reports the results of a commission to develop a field deployable rapid short tandem repeat (STR)‐based DNA profiling system to enable discrimination between tissues derived from a small number of individuals. Speed was achieved by truncation of sample preparation and field deployability by use of an Agilent 2100 BioanalyserTM. Human blood and tissues were stabbed with heated stainless steel wire and the resulting sample dehydrated with isopropanol prior to direct addition to a PCR. Choice of a polymerase tolerant of tissue residues and cycles of amplification appropriate for the amount of template expected yielded useful profiles with a custom‐designed quintuplex primer set suitable for use with the BioanalyserTM. Samples stored on wires remained amplifiable for months, allowing their transportation unrefrigerated from remote locations to a laboratory for analysis using AmpFlSTR® Profiler Plus® without further processing. The field system meets the requirements for discrimination of samples from small sets and retains access to full STR profiling when required.  相似文献   

19.
Forensic laboratories employ various approaches to obtain short tandem repeat (STR) profiles from minimal traces (<100 pg DNA input). Most approaches aim to sensitize DNA profiling by increasing the amplification level by a higher cycle number or enlarging the amount of PCR products analyzed during capillary electrophoresis. These methods have limitations when unequal mixtures are genotyped, since the major component will be over-amplified or over-loaded. This study explores an alternative strategy for improved detection of the minor components in low template (LT) DNA typing that may be better suited for the detection of the minor component in mixtures. The strategy increases the PCR amplification efficiency by extending the primer annealing time several folds. When the AmpF?STR® Identifiler® amplification parameters are changed to an annealing time of 20 min during all 28 cycles, the drop-out frequency is reduced for both pristine DNA and single or multiple donor mock case work samples. In addition, increased peak heights and slightly more drop-ins are observed while the heterozygous peak balance remains similar as with the conventional Identifiler protocol. By this extended protocol, full DNA profiles were obtained from only 12 sperm heads (which corresponds to 36 pg of DNA) that were collected by laser micro dissection. Notwithstanding the improved detection, allele drop-outs do persist, albeit in lower frequencies. Thus a LT interpretation strategy such as deducing consensus profiles from multiple independent amplifications is appropriate. The use of extended PCR conditions represents a general approach to improve detection of unequal mixtures as shown using four commercially available kits (AmpF?STR® Identifiler, SEfiler Plus, NGM and Yfiler). The extended PCR protocol seems to amplify more of the molecules in LT samples during PCR, which results in a lower drop-out frequency.  相似文献   

20.
Validation of the AmpF?STR® SEfiler Plus™ PCR Amplification kit with 29 and 30 PCR cycles for forensic STR analysis demonstrated that the kit had fewer artefacts than the AmpF?STR® SGM Plus™ kit (28 PCR cycles). The SEfiler Plus kit was more sensitive and devoid of colour artefacts, but showed more stutters, drop-ins, drop-outs and allelic imbalances.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号