首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 109 毫秒
1.
Planimetric measurements were employed for reading the results of an elution test to determine Lewis blood groups in dry human bloodstains. In the absorption-elution test, two varieties of indicators were used to detect eluted Lewis antibodies. First, 64 blood-stains aged between 2 to 8 months were tested with glutaraldehyde (GLA)-treated erythrocytes (planimetric hemagglutination assay, PMHA). This method demonstrated that dry stains weighing approximately 0.4 mg (equivalent to 3 microliters of whole blood) were sufficient for detection of Lea or Leb antigen. Results were obtained within 1 h. Then, 37 of these stains were tested with Lewis substance-coated latex particles (planimetric latex agglutination assay, PMLA). The presence of Lea and Leb antigen were detected from dry stains weighing 0.1 mg (equivalent to 1 microL of whole blood) within 3 h. Both these assays are faster and simpler with accuracy than the enzyme-linked immunosorbent assay (ELISA). Latex particles coated with Lewis substance are, in particular, strongly agglutinated and show agglutination patterns more clearly than erythrocytes. The blind tests using these two methods properly classified 7 Le(a + b-) and 23 Le(a-b + ) bloodstains; whereas, 5 Le(a-b-) stains were undetermined by the criteria for these tests. These results indicate the usefulness of the PMHA and PMLA for typing Lewis blood groups from small bloodstains.  相似文献   

2.
The Lewis blood grouping of human saliva stains could be detected by an enzyme-linked immunosorbent assay (ELISA) using anti-Le(a) and anti-Le(b) monoclonal antibodies with an avidin-biotin complex (ABC). The saliva stains (1.0 by 1.0 cm in size) were used as samples and not only could the Lewis substances of 57 individual stains be correctly typed by this method, but also it was clarified that there are several different secretion patterns of amounts of Le(a) and Le(b) substances in 3 individual Lewis types.  相似文献   

3.
应用时间决定性荧光免疫测定法(TR-FIA法),对129例健康成人唾液中Lweis及H1血型物质进行定量检测。Le阳性个体均不同程度地检出了Lea和Leb物质。Lea物质含量:Le(a+b-)型>Le(a-b+)型;Leb物质含量:Le(a-b+)型>Le(a+b-)型。Le(a+b-)型的Lea物质>Leb,Le(a-b+)型的Leb物质>Lea物质。Le阴性的部分个体未能检出Lewis物质,其余个体也仅检出微量。根据Lea和Leb物质在唾液中的相对含量,可以推测红细胞Lewis型,并提示Leb物质可能由Lea物质转化而形成。  相似文献   

4.
本实验应用单克隆抗人精子抗体和酶标记羊抗人精子抗体,采用ELISA方法确定精子抗原成份的存在。对10份新鲜精液,15份精斑进行了验测,其结果阳性率为100%。新鲜精液(精子数约10,000万个/ml)稀释100万倍,精斑浸出液稀释50万倍,均可出现阳性。对唾液斑、尿斑、乳汁斑、阴道斑、汗斑及输精管结扎的精液均为阴性。实验结果表明,本法检验精子抗原具有灵敏度高,特异性好的优点。  相似文献   

5.
The localization of ABH and Lewis antigens was examined in formalin-fixed, paraffin-embedded human tracheal and epiglottic glands using monoclonal anti A, B, H, Lea and Leb antibodies. The mucous cells of the glands showed reactivity with antibodies corresponding to the respective ABO blood groups of the tissue donors. The mucous cells from one blood group A, Le(a-b-) individual showed no reactivity with any antibodies and those from another blood group A, Le(a-b-) individual showed reactivity only with anti A antibody. In individuals from blood group Le(a + b-) of all ABO groups, the mucous cells reacted exclusively with anti Lea. In blood group O, Le(a-b+) individuals, the mucous cells showed intense reaction with anti H and Leb antibodies and weak to moderate reactivity with anti Lea. In Le(a-b+) individuals of A1, B and A1B blood groups, the mucous cells showed strong reactivity with anti A and/or B antibodies, moderate with anti Leb, weak or no activity with anti Lea and absent with anti H. In blood group A2 Le(a-b+) individuals, the mucous cells stained with anti A were weakly stained or completely unstained with anti H antibody, but cells negative with anti A gave strong positive reactions with anti H antibody.  相似文献   

6.
A blood group substance (BGS), a protein with ABH antigenic activity, was isolated from human seminal plasma and designated as p 84 (Sato, 1995). We have developed a method for determining the ABO blood type of semen by performing a sandwich enzyme-linked immunosorbent assay (ELISA) in which p 84 is captured with an anti-p 84 monoclonal antibody, and evaluated the specificity and sensitivity of this method. Although BGS activity was detected in semen sensitively by this method, it was not detected in saliva, urine, breast milk, blood or vaginal secretions. Since the concentration of p 84 in semen was independent of the secretion status, the status can be determined as non-secretor when p 84 but not BGS activity was detected. To determine the stability of BGS activity on p 84, dried stains of semen on filter paper were kept at 4, 26, and 37 degrees C for 8 months, 2 years and 1 month, respectively, and their BGS activities were examined. After 8 months at 4 degrees C, over 60% of the original BGS activity was recovered from the stain. The activity could be detected even from a square as small as 0.25 by 0.25 cm. After 1 month at 37 degrees C and 2 years at 26 degrees C, 31 and 20% of the BGS activity, respectively, still remained. It could be detected from the pieces of 1.0 by 1.0 cm and 0.5 by 0.5 cm squares, kept for 1 month at 37 degrees C and 2 years at 26 degrees C, respectively. Finally, semen was mixed with saliva or blood at varying volumetric ratios and used for the sources of dried stains. The BGS activity of p 84 could be detected in the stains until the ratio between semen and saliva or blood reached 1:4. We conclude that this sandwich ELISA offers a more sensitive and specific method for determining the ABO blood type of semen samples obtained from sexual assault victims than existing methods, such as the conventional absorption-elution and classical hemagglutination-inhibition tests.  相似文献   

7.
Among various seminal plasma proteins, semenogelin (Sg), produced in the seminal vesicle, has been considered a candidate for demonstrating the presence of semen. Sg consists of two proteins, one 52 kDa (Sg-I) in size, and the other a mixture of 71 and 76 kDa proteins (Sg-II). Recombinant Sg-I and Sg-II proteins were obtained using a baculovirus system and then injected into a rabbit to produce the respective antibodies [Characterization of recombinant precursor proteins of the human seminal plasma sperm motility inhibitor synthesized in insect cells, Int. J. Mol. Med. 2 (1998) 693]. When liquefied seminal plasma was immunoblotted with the anti-Sg-I and Sg-II antibodies, the anti-Sg-II antibody identified a wider range of the polypeptides originating from Sg than did the anti-Sg-I antibody. A dot-blot-immunoassay using anti-Sg-II antibody revealed a clear immunoreactive spot even when the semen was diluted 6400-fold. However, this assay showed that the Sg antigen was undetectable in saliva, urine, vaginal secretions, sweat, nasal secretions and serum. To determine the stability of Sg antigenic activity, filter paper with dried semen stains were kept at 37, 4 and 22 degrees C for 1, 6 and 18 months, respectively, and the Sg antigenic activity was examined. The activity was detectable in an area not less than 0.5 cm x 0.5 cm under all of the above environmental conditions during each period. Finally, semen was mixed with saliva or blood at various volumetric ratios, and used as a source of dried stains. The Sg antigenic activity was detectable in the stains until the ratio of semen to saliva or blood reached 1:8. These results suggest that Sg may be useful as a marker for semen identification.  相似文献   

8.
<正> 1978年美国Sensabaugh分离出精浆特异蛋白P30,并成功的制备出相应的抗P30血清。1987年我国也研制出抗人精浆特异蛋白P30血清,并应用该种抗血清建立了几种琼脂扩散和电泳方法鉴定人精斑。由于人精液中P30含量不高,平均为1.52±0.676mg/ml,鉴定微量精斑存在困难。为了更有效的提高方法的灵敏度。我们建立了鉴定微量人精斑的ELISA固相P30抗体法,现报告如下。  相似文献   

9.
阐明非分泌型的基因型与血型物质分泌量和Lewis表型的关系。应用时间决定性荧光免疫测定法(TR-FIA),检测传统的A型Lewis阳性非分泌型个体唾液中H、A及Lewis抗原含量,并以序列特异性PCR,确定其基因型。非分泌型个体唾液中检出了高含量的Lea抗原,其中8例不同程度的检出了少量H、A和Leb抗原,其FUTZ位点为se2/se2纯合型,属Le(a+b+)型;1例基因型为se3/se5杂合型,未能检出H、A及Leb抗原,属Le(a+b-)型。se2是弱分泌基因,se3及se5是非分泌基因。  相似文献   

10.
本文用IEF结合使用过氧化物酶标记第二抗体的酶免疫分析法检测了17名键康成年男性的精液(斑)和唾液斑及10名健康成年女性的阴道分泌液中的GC表现型。结果发现17份人类精斑均可测出三种GC蛋白普通表现型。在10份阴道液中测出一份样本的GC表现型,3份样本有不甚清楚的GC带,不能定型,其他样本均无GC带。17份唾液斑未测出GC。本法的灵敏度(0.675ng)比文献报道的用过氧化物酶标记第二抗体的酶免疫分析(5.6ng)高。  相似文献   

11.
The ABH group in a trace amount of saliva could be determined by an enzyme-linked immunosorbent assay (ELISA) using an avidin-biotin-peroxidase complex (ABC) technique. In this method ABH blood group substances as a solid phase are adsorbed to wells of a microtiter plate made of polystyrene. The primary antibody corresponding to the blood antigen adheres onto the wells, and reacts with the biotinylated secondary antibody. The previously formed ABC reagent is then added to the above wells, and finally the absorbance produced by the interaction of the peroxidase activity with a chromogenic substance is measured at 492 nm. This method proved to be clearly more sensitive for the detection of ABH blood groups in secretor-saliva than the conventional hemagglutination inhibition test. Also the ABH group of non-secretor-saliva could be easily determined by this method.  相似文献   

12.
本文介绍了利用型特异性沉淀素血清环状沉淀法检验人唾液斑、精液斑ABO血型的方法与实验结果,并与中和试验及解离试验进行了比较。实验结果表明,本法操作简便,对多种干扰条件下的唾液斑、精斑均具有高度的型特异性,并能从分泌液与血液的混合斑中准确地鉴别出分泌液的血型。本法仅需0.4cm的分泌斑纱线即可进行血型鉴定,其灵敏度高于中和试验而略低于热解离试验,并能有效地检出陈旧分泌液斑中的型物质,因此适于在实际检案中应用。  相似文献   

13.
Forensic investigations often demand a clear definition of secretor status. Lewis-typing of secretion stains may help to verify non-secretor results and to identify mixtures of secretions from Le (a-b-) persons and secretors (or non-secretors). Furthermore it gives an additional check on secretor status, determined by ABO-grouping. Few problems may arise, when testing prepared saliva or semen stains. Therefore our interest was focussed on the possibility of Lewis-typing in stains appearing in forensic case work such as cigarette tips, stamps and envelope flaps, semen stains and vaginal swabs, nasal secretion, sweat and urine stains. All stains with the exception of sweat and urine were successfully Lewis-typed. In saliva stains Lewis substances could be determined even after 5 years and in semen stains for at least up to 40 days.  相似文献   

14.
Saliva and saliva-stained materials were examined as potential sources of deoxyribonucleic acid (DNA) for DNA analysis and identity testing. In this paper, the authors demonstrate that DNA was isolated and DNA banding patterns suitable for DNA typing were obtained from fresh saliva and various saliva-stained materials, such as envelopes, buccal swabs, gags, and cigarettes. Furthermore, DNA and DNA banding patterns were obtained from actual forensic evidentiary samples containing mixed saliva/semen stains. The DNA banding patterns obtained from saliva or saliva-stained material were indistinguishable from the patterns obtained from blood or hair from the same individual. Intact DNA was readily isolated and DNA banding patterns were obtained from saliva stored at -20 degrees C and dried saliva stains stored under varying conditions. We conclude that saliva and saliva-stained material can be good sources of DNA for analysis and for DNA typing in certain forensic settings.  相似文献   

15.
The stability of salivary α‐amylase is a critical factor in both catalytic and immunological method‐based forensic saliva identification. This study aimed to assess the sensitivity of catalytic and immunological tests on degraded saliva samples. Degraded saliva stains were prepared by microbial decomposition using humid soil. Salivary α‐amylase activity was catalytically detected both qualitatively and quantitatively using the Phadebas® amylase test. As immunological methods, we conducted qualitative and quantitative tests using the RSID?‐saliva test and ELISA, respectively. Salivary α‐amylase activity of degraded samples (incubated at 37°C for 12 h) was significantly lower than that of controls in the quantitative tests. All the degraded samples obtained by the humid soil produced negative results in the Phadebas® tests, but showed positive results in the RSID?‐saliva test and ELISA. These results suggest that immunological tests are effective for testing degraded saliva samples that have lost their enzymatic activity.  相似文献   

16.
p- and o-Aminomethamphetamine were synthesized as haptens to be coupled with carrier protein at the benzene ring of methamphetamine. Immunogens were prepared by the glutaraldehyde method or the MBS (N-(m-maleimidobenzoyloxy)succinimide) type cross-linking reagent method. In particular, immunization with p-aminomethamphetamine-bovine serum albumin (BSA) conjugate prepared by the glutaraldehyde method gave an anti-methamphetamine antiserum having a low cross-reactivity with methylephedrine. With the antiserum, three kinds of immunoassays for methamphetamine were established. An enzyme immunoassay (EIA) and an enzyme-linked immunosorbent assay (ELISA) were developed with alkaline phosphatase (ALP) as a label enzyme. The amount of antibody bound ALP conjugate was determined by its activity in dephosphorylating p-nitrophenyl phosphate in EIA and nicotinamide adenine dinucleotide phosphate (NADP+) in ELISA. The range of methamphetamine measurable by ELISA was 0.025-0.5 ng/well and its sensitivity was superior to that of EIA (0.3-300 ng/tube). A latex agglutination inhibition reaction test (LAIRT) was also developed for the mass screening method of urine samples. The sensitivity of this method for methamphetamine was 0.1 micrograms/ml urine.  相似文献   

17.
应用超薄层聚丙烯酰胺凝胶等电聚焦技术对辽宁地区200例正常人精子黄递酶Ⅲ型(DIA)的分布进行了研究。其基因频率分别为DIA_3~1=0.6850,DIA_3~2=0.2875,DIA_5~3=0.0275。由阴道液、唾液、乳汁及无精子症精液不能判定DIA_3型。室温保存精斑可检出时限为9个月。  相似文献   

18.
The detection of p30 by means of an indirect thin-layer immunoassay (TIA) is described. Extracts from 20 samples can be analyzed in approximately 2 h with a detection limit of approximately 50 ng. The p30 protein was detected in seminal stains which had been stored at room temperature for six months and at 130 degrees C for 4 h. Blood, saliva, urine, perspiration, and tears did not interfere with the method. The reliability of the method was demonstrated in a blind study.  相似文献   

19.
An ELISA method for the detection of salivary amylase in dried stains using a monoclonal anti-human salivary amylase antibody was developed. Studies demonstrated the assay to be sensitive down to 0.0002 Sigma units and showed a linear response between absorbance and salivary amylase activity between 0.002 and 0.2 units. The assay showed no cross reactivity with either commercially purchased human pancreatic or bacterial amylase. Sample studies utilizing swabs from several human body fluids showed that 100% of all saliva containing swabs (sixteen of sixteen) and 13% of non-saliva human body fluid swabs (eight of sixty-three) showed a net absorbance with the method. Of these eight non-saliva swabs yielding a net absorbance, none exceeded a salivary amylase activity of 0.003 units. In contrast, only three of the sixteen saliva-containing swabs (swabs produced from saliva diluted 1:5, 1:6, and 1:10, respectively) showed an activity below 0.2 units. Of these swabs, the 1:100 dilution showed the lowest activity (0.048). This value is still more than ten times that of the non-saliva containing swab with the highest activity.  相似文献   

20.
Immunocytochemical studies were performed on tracheal wall samples embedded in paraffin; the samples were taken at 23 autopsies. In all cases, the red cells had been typed in postmortem serological studies as being Le(a-b-). Blood-group antigens were demonstrated by the indirect immunoperoxidase technique, using monoclonal Anti-A, Anti-B, Anti-Lea and Anti-Leb; H was detected by UEA 1. The secretor characteristics could clearly be diagnosed from the ABH staining pattern of the mucous glands. In 11 cases, the lewis antigen labeling patterns were identical to the group of Lewis-positive individuals. It seems probable, from the statistical point of view, that these 11 individuals were, in fact, Lewis-positive and that the negative serology resulted from deterioration of the cadaver blood samples. The immunocytochemistry was quite different in the remaining 12 cases: (a) secretors (n = 9) were completely negative for Lea, Leb was equally negative in one case, but in the remainder it was detectable within mucous epithelia in minimal amounts and in an atypical granular distribution; (b) nonsecretors (n = 3) reversely exhibited complete negativity for Leb but a minimal staining for Lea. These findings are in harmony with the well established Lewis serology typing of secretions in Lewis negative individuals. Thus, a minimal Lewis antigen biosynthesis and secretion seem to occur in the absence of the Le gene: A alpha-4-L-fucosyltransferase of low activity might be the product of the allele le.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号