首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 765 毫秒
1.
Using a mathematical method of experiment planning (Latin square), the authors suggest the optimal conditions for extraction of propifenasone and paracetamol, the basic components of caffeine and saridon tablets, from water solutions: extraction with ethylacetate (pH 2) for 5 min in the presence of an electrolyte (sodium chloride or ammonium sulfate) quantum satis. The possibility of extraction of caffeine and codeine under these conditions was tested. When extracting the components of caffeine and saridon tablets, paracetamol, propifenasone, and caffeine should be extracted with ethylacetate at pH 2 and codeine by chloroform at pH 10.  相似文献   

2.
Kratom is an herbal product commonly used for its effects which are similar to opioids and stimulants. Few studies demonstrate the dangers and lethality of Kratom, and most fatalities from Kratom involve other abused substances. In the current case report, a 33‐year‐old white man with a known history of opioid abuse and mental illnesses was found unresponsive in his basement with no obvious signs of trauma. After resuscitative efforts, he was pronounced dead and taken for autopsy evaluation. Blood from the inferior vena cava was analyzed for common abused substances. The laboratory toxicology work‐up revealed positive findings of caffeine, cotinine, and naloxone with low levels of Δ‐9 tetrahydrocannabinol. However, a marked level of mitragynine at 1.9 mg/L was observed, the highest reported to date. Given the facts and evidence, the medical examiner certified the cause of death as “mitragynine toxicity” and the manner of death was classified as an “accident.”  相似文献   

3.
A simple, quick, selective, sensitive, and effective field-friendly method capable of being used by nonexperts has been developed for detecting mitragynine in Mitragyna speciosa (kratom) using surface-enhanced Raman spectroscopy (SERS). Over 100 samples and blanks (known to be either positive or negative for the presence of mitragynine) were examined in duplicate using five identical handheld Raman spectrometers, which provided a data set of over 1,000 examinations. Based on the results of these analyses, the method yielded a true-positive rate of 99.3%, a true-negative rate of 97.9%, a false-positive rate of 2.1%, and a false-negative rate of 0.7%. The average minimum detectable concentration (Cm) of mitragynine that reproducibly yielded a match for one of the library spectra on all five instruments was determined to be 342 ng/mL (ppb). This Cm value is a conservative estimate considering that the extraction process was not fully optimized by this study, which was not necessary since the Cm value achieved was well below typical mitragynine concentrations in kratom (1.3–2.3%). The method is ideal (i) for prioritizing samples for additional testing using other more time-consuming laboratory-based techniques needed to detect and quantify mitragynine and (ii) for field use at international mail facility (IMF) satellite laboratories to help interdict kratom and prevent this dangerous product from reaching the U.S. supply chain.  相似文献   

4.
Kratom is a plant originating in Southeast Asia that has been used for its dose-dependent stimulant and opioid effects. The main active compound in kratom is mitragynine, an alkaloid with affinity for the mu-opioid receptor. Toxicity and fatalities related to kratom use have increased substantially in recent years. In this case report, we describe a 44-year-old man who was found deceased in bed. The only significant finding at autopsy was abdominal distension with >4 L of ascites. Toxicology testing was performed on femoral blood which showed 79 ng/mL of hydromorphone, 560 ng/mL of mitragynine, and 240 ng/mL of olanzapine. In addition, creatinine and urea in vitreous humor were significantly elevated, consistent with renal impairment. Death was attributed to hydromorphone toxicity with mitragynine being a contributing factor.  相似文献   

5.
The presence of the heroin metabolite 6-monoacetylmorphine (6-MAM) in urine is used to definitively identify recent heroin abuse. A rapid and sensitive GC-MS method for the simultaneous analysis of codeine, norcodeine, morphine, normorphine and 6-MAM in urine was developed and successfully applied to the analysis of 321 'heroin-positive' urine specimens from individual subjects (identified by the presence of 6-MAM), to provide quantitative urinary opiate excretion data for heroin abusers.The cohort analysed was composed of 238 males (age range 16-53 years) and 83 females (age range 16-50 years). The concentrations of free 6-MAM, morphine and codeine determined in these 321 specimens ranged between 103-246,312, 129-193,600 and 103-519,000 microg/l, respectively. Free norcodeine and normorphine concentrations were found to range between 143-50,200 and 205-149,700 microg/l, respectively. A statistically significant relationship was determined between the subject age and the 6-MAM concentration, possibly indicating opiate tolerance in these individuals.  相似文献   

6.
A fatal case involving the suicidal ingestion of secobarbital, nitrazepam, and codeine is presented. The drugs were quantified using gas chromatography for codeine and high-performance liquid chromatography for the two other drugs. The blood concentrations of secobarbital, nitrazepam, and codeine were found to be 11.48, 1.72, and 0.036 microgram/ml, respectively. Results are discussed in the light of the existing literature.  相似文献   

7.
Mixed drug reactions are frequently encountered in emergency department overdose cases and also in fatal intoxications. Assessment of the relative contribution of each drug in producing adverse effects is often compounded by lack of case history and the paucity of cases reported in the literature. This report describes a fatal intoxication with three common over-the-counter medications: guaifenesin, diphenhydramine, and chlorpheniramine. A 48-year-old woman was found dead in the attic bedroom of her residence. Specimens obtained at autopsy for toxicologic analysis included heart blood, urine, bile, gastric contents, vitreous humor, and cerebrospinal fluid. The over-the-counter drugs were identified and quantitated by acid/neutral or basic liquid-liquid extraction followed by gas chromatographic analysis with nitrogen phosphorus detection. Concentrations of guaifenesin, diphenhydramine, and chlorpheniramine detected in the heart blood were 27.4, 8.8, and 0.2 mg/L, respectively. The cause of death was determined to be acute intoxication by the combined effects of guaifenesin, diphenhydramine, and chlorpheniramine, and the manner of death was determined to be suicide. To our knowledge, the blood guaifenesin concentration in this case is the highest reported concentration to date associated with an acute intoxication.  相似文献   

8.
The leaves of Mitragyna speciosa are used as a substitute for opium. Criminal penalties for possession of mitragynine in this country are assigned for possession of defined quantities of mitragynine and its identification as Mitragyna speciosa by thin-layer chromatography and gas chromatography.  相似文献   

9.
Amberlite XAD-2, a nonionic polystyrene divinylbenzene resin, was first used for the analysis of drugs in urine and a number of reports have described the development at optimal conditions for extraction, including type of resin columns, pH conditions, and eluting solvents. XAD-4 and XAD-7 resins were compared to the similarly structured XAD-2 resin and no significant advantage over the XAD-2 resin for drug screening was observed. A quantity of 5 to 6 g of resin was found to have sufficient capacity for the extraction of 200 ml of pentobarbital solution (1 mg/100ml). A column flow rate of approximately 15 ml/min (gravitational flow) was sufficient for analysis and slower rates were not more efficient. A mixture of ethyl acetate and 1,2-dichloroethane (3:2) was found to give best overall recovery (66 to 94%) of drugs, the resulting extracts being reasonably free of interfering substances. A pH value of 8.5 is recommended as optimum for comprehensive analysis of acidic and basic drugs. Recovery studies were conducted on spiked samples to determine drug losses occuring during various steps in the XAD-2 extraction procedure for four acidic (amobarbital, secobarbital, pentobarbital, and phenobarbital) and four basic (morphine, codeine, meperidine, and methadone) drugs. A relatively small amount (0 to 5%) of the drugs was not adsorbed by the resin and amounts varying from 6 to 40% failed to be desorbed by the eluting solvent. Additional losses occurred during the removal and analysis of TLC spots. Recovery of drugs from aqueous solutions analyzed with the XAD-2 resin were compared to recoveries reported in the literature with other XAD-2 resin methods for the extraction of drugs from urine. Recovery of phenobarbital, morphine, and codeine improved by 4 to 23% while recoveries of amobarbital, pentobarbital, secobarbital, methadone, and meperidine were 4 to 28% less efficient when compared to literature data.  相似文献   

10.
A morphine to codeine ratio greater than unity (M/C>1) has been suggested as an indicator of heroin use in living individuals. The aim of this study was to examine the morphine to codeine ratio in a large population (N=2438) of forensically examined autopsy cases positive for 6-monoacetylmorphine (6-MAM) and/or morphine in blood and/or urine. Blood and urine concentrations of 6-MAM, morphine and codeine were examined using GC-MS and LC-MS/MS methods. In 6-MAM positive samples, the M/C ratio was greater than unity in 98% (N=917) of the blood samples and 96% (N=665) of the urine samples. Stratification of 6-MAM negative cases by M/C above or below unity revealed similarities in morphine and codeine concentrations in cases where M/C>1 and 6-MAM positive cases. Median blood and urine morphine concentrations were 8-10 times greater than codeine for both groups. Similarly to 6-MAM positive cases, 25-44 year-old men prevailed in the M/C>1 group. In comparison to cases where M/C ≤ 1, the M/C ratio was a hundred times higher in both 6-MAM positive and M/C>1 cases. The range of morphine concentration between the lowest and the highest quintile of codeine in M/C>1 cases was similar to that in 6-MAM positive cases. This range was much higher than for M/C ≤ 1 cases. Moreover, linear regression analyses, adjusted for age and gender, revealed a strong positive association between morphine and codeine in 6-MAM positive and M/C>1 cases. The M/C ratio appeared to be a good marker of heroin use in post-mortem cases. Both blood and urine M/C>1 can be used to separate heroin users from other cases positive for morphine and codeine.  相似文献   

11.
High performance liquid chromatography with diode array detection (HPLC-DAD) was used to develop a method for the simultaneous determination of morphine, codeine, 6-acetylmorphine (6AM), cocaine, benzoylecgonine (BEG), cocaethylene, methadone and its metabolite, 2-ethylidene-1,5-dimethyldiphenylpyrrolidine (EDDP), in plasma. Following solid-phase extraction with Bond Elut Certify cartridges, chromatography was performed on an X-Terra RP8 column (250 mm x 4.6 mm i.d., 5 microm particle size), using acetonitrile-phosphate buffer pH 6.53 as mobile phase and elution in the gradient mode. The detector response was linear at concentrations over the range 0.1-10 microg/mL in plasma, and the correlation coefficients for the eight drugs studied were all higher than 0.99. The average extraction recoveries from plasma ranged from 60% for BEG to 95% for methadone. The precision was acceptable, with coefficients of variation oscillating between 2.55% and 6.45%. The accuracy was found to be within satisfactory limits (+/- 8.1%). Finally, the method was applied to 21 plasma samples from fatal overdoses, obtaining positive results for two or more drugs.  相似文献   

12.
A capillary column gas chromatographic method is described for the simultaneous determination of morphine, codeine, heroin, 3- and 6-monoacetylmorphine, nalorphine, naloxone, ethylmorphine, and naltrexone. The drugs were extracted from 2 ml plasma, urine, or other biological samples, including tissue under alkaline conditions in chloroform-isopropanol-n-heptane (50:17:33, v/v), with levallorphan as an internal standard. The drugs were extracted into acid and then reextracted into chloroform after the acid had been alkalinized. After derivatization with trifluoroacetic anhydride, an aliquot was injected into a 25m capillary column equipped with a nitrogen phosphorus detector. The lower limits of detectability, extraction recovery, and the within-run and day-to-day precision of results were determined for each drug. Our results indicate that the procedure is suitable for use in overdose screening and therapeutic drug monitoring.  相似文献   

13.
GC法检测血液和尿液中甲基苯丙胺和咖啡因   总被引:1,自引:1,他引:0  
目的建立同时测定血、尿中甲基苯丙胺和咖啡因含量的方法。方法应用GC/NPD技术,以4-苯基丁胺为内标,直接碱化,用氯仿提取,三氟乙酸酐衍生化,8CB熔融石英毛细管柱(30m×0.25mm×0.25μm)分析。结果生物样品中甲基苯丙胺与咖啡因在0.012—7.5μg/mL浓度范围内线性关系良好,检测限(S/N=3)依次为1.2ng/mL,0.6ng/mL(血);1.6ng/mL,0.8ng/mL(尿)。苯丙胺在0.017—10.0μg/mL浓度范围内线性关系良好,检测限为1.6mg/mL(血),3.2ng/mL(尿)。所有样本回收率均大于85%。结论本方法准确、灵敏,适用于血、尿中甲基苯丙胺及其代谢物苯丙胺的三氟乙酸酐衍生化物和咖啡因的同时检测,为判定滥用毒品种类、追查毒品来源以及研究生物体内甲基苯丙胺和咖啡因的交互影响提供了检测手段。  相似文献   

14.
The toxicological findings of a multi-drug related fatal poisoning are described here. A 35-year-old Caucasian male found dead on the kitchen floor was a known user of abused drugs and had been taking aspirin alone or in combination with phenacetin and caffeine for the relief of joint pains. The gross examination of the organs at autopsy revealed slight grooving of the uncus and various stages of necrosis in the renal papillae. Histological examination confirmed the gross appearance of pulmonary congestion and edema, cerebral edema and interstitial nephritis of the tubules. Toxicological evaluation of the blood and urine samples disclosed the presence of propoxyphene (51 and 250 mg/l), salicylate (185 and 2750 mg/l), caffeine (16 and 37 mg/l), and phenacetin (9.6 and 20 mg/l). Furthermore, acetaminophen also was present in the plasma (54 mg/l) and urine. A gas liquid chromatographic method for simultaneous analysis of phenacetin and caffeine utilizing a nitrogen phosphorus detector was proposed.  相似文献   

15.
16.
Concentrations of unconjugated morphine, codeine and 6-acetylmorphine (6-AM), the specific metabolite of heroin, were determined in urine specimens from 339 individuals apprehended for driving under the influence of drugs (DUID) in Sweden. After an initial screening analysis by immunoassay for 5-classes of abused drugs (opiates, cannabinoids, amphetamine analogs, cocaine metabolite and benzodiazepines), all positive specimens were verified by more specific methods. Opiates and other illicit drugs were analyzed by isotope-dilution gas chromatography-mass spectrometry (GC-MS). The limits of quantitation for morphine, codeine and 6-AM in urine were 20 ng/mL. Calibration plots included an upper concentration limit of 1000 ng/mL for each opiate. We identified the heroin metabolite 6-AM in 212 urine specimens (62%) at concentrations ranging from 20 ng/mL to > 1000 ng/mL. The concentration of 6-AM exceeded 1000 ng/mL in 79 cases (37%) and 31 cases (15%) were between 20 and 99 ng/mL. When 6-AM was present in urine the concentration of morphine was above 1000 ng/mL in 196 cases (92%). The concentrations of codeine in these same urine specimens were more evenly distributed with 35% being above 1000 ng/mL and 21% below 100 ng/mL. These results give a clear picture of the concentrations of unconjugated morphine, codeine and 6-acetylmorphine that can be expected in opiate-positive urine specimens from individuals apprehended for DUID after taking heroin.  相似文献   

17.
A simple and rapid method for the analysis of heroin seizures by micellar electrokinetic chromatography with short-end injection is described. Separations were performed using an uncoated fused silica capillary, 50 cm x 50 microm I.D. x 360 microm O.D. with an effective separation length of 8 cm. The system was run at 25 degrees C with an applied negative voltage of -25 kilovolts. Injection of each sample was for 2 s at -50 mbar. UV detection was employed with the wavelength set at 210 nm. The background electrolyte consisted of 85:15 (water:acetonitrile, v/v) containing final concentrations of 25 mM SDS and 15 mM sodium borate, pH 9.5. Samples and standards were prepared in 0.1% v/v acetic acid and diluted in the run buffer containing 1 mg/ml of N,N-dimethyl-5-methoxytryptamine as an internal standard. Under these conditions a text mixture containing caffeine, paracetamol, morphine, codeine, heroin, and acetylcodeine was resolved within 1.5 min. The method was used to determine the concentration of heroin in heroin seizure samples, and the results were in good agreement with those obtained by a validated gas chromatographic method.  相似文献   

18.
目的建立了鸦片中吗啡、可待因、蒂巴因、罂粟碱、那可汀5种常量生物碱和牛心果碱、劳丹宁、劳丹素等12种痕量生物碱同时分离鉴定的超高效液相色谱-高分辨四极杆飞行时间串联质谱(UPLC/Q-TOF)方法。方法采用Agilent Eclipse Plus C18RRHD(2.1 mm×100 mm,1.8μm)色谱柱,以10 mM甲酸铵溶液和乙腈体系梯度洗脱,使用ESI离子源,正离子模式下采集数据。结果借助UPLC的快速分离和Q-TOF-MS测定的精确分子量和二级碎片信息,实现了17种生物碱的检测。应用SIMCA-P软件对78份国产鸦片和200份缅甸产鸦片进行偏最小二乘法判别分析(partial least squaresdiscriminate analysis,PLS-DA),比较不同地区鸦片样品中生物碱的差异,建立了区分国产鸦片和缅甸产鸦片的判别方法。结论所建立的方法用于鸦片样品中常量和痕量生物碱的检测及鸦片样品的产地判别,具有快速、高效、灵敏、准确的特点。  相似文献   

19.
The inhalation of heroin vapors after heating on aluminium foil ("chasing the dragon") is gaining popularity nowadays among heroin users seeking to avoid the risks of parenteral drug administration. The heroin-smoking procedure was simulated under laboratory conditions by heating the samples on aluminium foil at 250 to 400 degrees C and collecting the vapors in a condenser trap. A total of 72 pyrolysis products of diacetylmorphine, street heroin, residues from aluminium foils used to smoke street heroin, typical by-products, and adulterants were detected by gas chromatography/mass spectrometry (GC/MS). About half of these compounds could be identified. Diacetylmorphine (base and salt) undergoes substantial to complete degradation. Some typical street heroin constituents, like morphine, codeine, acetylcodeine, papaverine, and caffeine, are rather heat-stable. Other compounds, like noscapine and paracetamol, are pyrolyzed to a greater extent. The principal chemical reactions leading to the formation of pyrolysis products are desacetylation, transacetylation, N-demethylation, O-methylation, ring cleavage and oxydation.  相似文献   

20.
A totally automated procedure has been developed for the detection and quantitation of morphine and codeine in urine case samples. The samples were initially screened for these drugs by a Syva EMIT Toxicology System (ETS). A Zymate laboratory robotic system confirms positive samples from Syva ETS by performing the hydrolysis, extraction, and derivatization of morphine and codeine. The derivatized morphine and codeine were detected using gas chromatography/mass spectrometry (GC/MS). Enzymatic hydrolysis conditions were experimentally optimized during method development. The automation of these procedures has proven to be reliable and efficient.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号