首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
目的建立一种自动化提取脱落上皮细胞类生物检材DNA的方法。方法附着于不同载体上的脱落上皮细胞类生物检材共278份,应用Eppendorf epMotion 5075LH工作站结合DNA IQTM系统提取模板DNA,并用Identifiler试剂盒进行STR检验。结果在278份被检的生物检材,其中126份检材获得13个基因座以上的STR分型,不同类型的检材其检出率不相同,最高达73.44%,最低为10.89%。结论脱落上皮细胞类检材应用自动化工作站提取DNA模板可在法医日常检案中广泛应用。  相似文献   

2.
The Netherlands Forensic Institute recently validated a fully automated system for sample lysis, the AutoLys workstation and AutoLys tubes, developed in collaboration with Hamilton Robotics. We have carried out the developmental validation of the AutoLys system and concluded it offers a solution to drastically reduce user-errors, increase DNA yields, gain in productivity, while maintaining quality. This article reports on the study setup and discusses the results of comparing the AutoLys workstation to the conventional (manual) method. The AutoLys system proved to successfully process all commonly found forensic sample types, producing high quality extracts, containing on average 12.1% more DNA than manually extracted samples (as determined by qPCR and STR-profiling). The optimized robotic protocol minimizes the risk on cross-contamination (no cross-contamination detected in over 500 samples tested) and retains the flexibility to adjust chemically relevant variables specific to a laboratory's individual requirements. The fully automated process enables complete sample-tracking, drastically reducing the risk on user-errors. The NFI is currently validating an on-deck magnetic bead-based purification of the lysates.  相似文献   

3.
An ultrasound-assisted extraction method is proposed for the determination of trace elements in hair samples by inductively coupled plasma-mass spectrometry (ICP-MS) for forensic investigation. Prior to analysis, 25 mg of hair samples were accurately weighed into (15 mL) conical tubes. Then, 2 mL of 20% HNO3 is added to the samples, sonicated at 2 min (50 W, 100% amplitude), and then further diluted to 10 mL with Milli-Q water. Resulted diluted slurries are centrifuged and the analytes are directly determined in the supernatant. Calibrations against aqueous solutions were carried out with rhodium as internal standard. The method was successfully applied for the extraction of Al, As, Ba, Be, Cd, Co, Cr, Cu, Mn, Pb, Tl, U, V and Zn with a method detection limit (3 s, n = 20) of 0.1, 0.4, 0.2, 0.09, 0.08, 0.04, 0.1, 2.9, 1.0, 0.9, 0.04, 0.05, 0.1 and 4.2 ng/g, respectively. Method accuracy is traceable to Certified Reference Materials (CRMs) 85 and 86 human hair from the International Atomic Energy Agency (IAEA). Additional validation data are provided based on the analysis of hair samples from the trace elements intercomparison program operated by the Institut National de Sante’ Publique du Quebec, Canada. The proposed method is very simple and can be applied for forensic purposes with the elimination of sample digestion step prior to analysis. Then, a considerable improvement in the sample throughput is archived with the use of the proposed method.  相似文献   

4.
This article describes a fully automated procedure for detecting cannabinoids in human hair samples. The procedure uses alkaline hydrolysis and headspace solid-phase dynamic extraction (HS-SPDE), followed by on-coating derivatization and gas chromatography-mass spectrometry (GC-MS). SPDE is a further development of solid-phase microextraction (SPME), based on an inside needle capillary absorption trap. It uses a hollow needle with an internal coating of polydimethylsiloxane as extraction and pre-concentration medium.Ten mg of hair were washed with deionised water, petroleum ether and dichloromethane. After adding deuterated internal standards, the sample was hydrolyzed with sodium hydroxide and directly submitted to HS-SPDE. After absorption of analytes for an on-coating derivatization procedure, the SPDE-needle was directly placed into the headspace of a second vial containing N-methyl-N-trimethylsilyl-trifluoroacetamide before GC-MS analysis. The limit of detection was 0.14 ng/mg for Delta(9)-tetrahydrocannabinol, 0.09 ng/mg for cannabidiol, and 0.12ng/mg for cannabinol. Absolute recoveries were in the range of 0.6 to 8.4%. Linearity was verified over a range from 0.2 to 20 ng/mg, with coefficients of correlation between 0.998 and 0.999. Intra- and inter-day precision were determined at two different concentrations and resulted in ranges between 2.3 and 6.0% (intra-day) and 3.3 and 7.6% (inter-day). Compared with conventional methods of hair analysis, this automated HS-SPDE-GC-MS procedure is substantially faster. It is easy to perform without using solvents and with minimal sample quantities, and it yields the same sensitivity and reproducibility. Compared to SPME, we found a higher extraction rate, coupled with a faster automated operation and greater stability of the device.  相似文献   

5.
目的利用TE-MAGS在TECAN工作站上结合磁珠试剂盒,建立自动化工作站批量纯化现场检材DNA的方法,并探讨其在法医物证检案中的应用。方法灵敏度测试:标准品使用0.1ng/μL 9947A,用200μL TES稀释制备DNA总量0.1ng~1ng共10种的标准样品,采用本文方法提取纯化,使用IdentifilerTM试剂盒扩增,用3130XL型测序仪检测,Gene Mapper ID-X分析,分析STR图谱质量;纯化能力测试:在1ng总量的标准样品中加入腐殖酸、血红素,采用本文方法提取纯化、扩增检测,分析STR图谱质量;实际案件应用对比:收集304份现场检材,分别采用本方法和硅珠法进行提取纯化,经扩增检测,统计对比两种提取纯化方法 STR分型成功率。结果灵敏度测试:0.1ng~0.2ng总量标准样品提取的DNA模板,扩增后可检测到部分基因座STR图谱,0.3ng~1ng总量标准样品提取的DNA模板,扩增后可以得到完整的STR图谱;纯化能力测试:对混合有一定浓度的腐殖酸、血红素的标准样品的提取产物检测图谱未见明显抑制;实际案件应用对比测试:304份现场检材工作站磁珠法检出成功率(50%)高于硅珠法(40.8%)。结论本文所建立的方法缓冲范围较大,回收率高,纯化能力强,提取产物STR分型成功率高,适合现场检材批量化DNA检验。  相似文献   

6.
目的建立自动化工作站同步提取不同种类涉案法医生物检材DNA的新方法。方法选用TECAN Freedom EVO100.4、75—2型自动化提取、加样工作站,采用磁珠法及Chelex-100法对各类涉案生物检材进行DNA提取、PCR扩增、毛细管电泳检测其STR分型,进行比较测试。在“全国公安机关DNA数据库应用系统”中建立并应用实验室信息管理系统(LIMS)模拟实施规范化DNA检案。结果1552份各类检材,采用工作站-磁珠法提取DNA效果最佳,STR检测成功率为95%,工作站-Chelex法为88%;二者分别与其手工提取法比较,成功率无明显差异。92个样本同期检测,自动化工作站较手工操作DNA检案时间可缩减1.25倍。结论工作站域珠法提取涉案检材DNA,可获得满意的STR分型结果。应用LIMS管控,可有效防控污染,明显提高检案效率及鉴定质量。  相似文献   

7.
自动化工作站是指运用生化技术对生物性检材进行批量处理分析的全自动化工作平台,它可在短时间内批量进行移液,加样,混合等操作,特别适合用于大量生物性检材的PCR模板的制备。本文仅对DNA提取自动化工作站的基本模式、基本方法、法医学应用等进行综述,以期使该技术在法医DNA分析中得到更广泛的应用。  相似文献   

8.
应用自动化工作站提取常见生物样本DNA   总被引:5,自引:2,他引:5  
目的建立使用自动化工作站提取法医案件生物样本DNA的方法。方法选用Biomek 3000自动化工作站,采用DNA IQTM系统及Chelex法对法医案件中常见生物样本进行DNA提取,荧光定量技术进行定量,PCR扩增16个STR基因座并与手工提取方法比较。结果与手工提取方法进行比较,选用自动化工作站结合使用DNAIQTM系统及Chelex法提取DNA可获得满意的STR检验结果。结论自动化工作站可用于法医案件中常见生物样本的DNA提取。  相似文献   

9.
10.
A laboratory study interested in the analysis of human hair for drugs-of-abuse was conducted to determine if drugs could be detected and quantified from hair. Supercritical fluid extraction (SFE) techniques followed by GC-MS analysis were applied to extract amphetamines from hair. The group of amphetamines included methylenedioxyamphetamine (MDA), methylenedioxymetamphetamine (MDMA), methylenedioxyethylamphetamine (MDEA) and internal standard mephentermine (MP). To validate information on amphetamine use in hair, powdered hair samples free from drugs were collected and soaked in a known amphetamine standard solution. Authentic fortified case hair samples taken from known drug users known to have consumed amphetamines were also analyzed for amphetamine. Results from this study show that amphetamine use can be detected in spiked and authentic fortified human hair using SFE techniques for qualitative and quantitative reproducible results.  相似文献   

11.
磁珠DNA自动提取系统是将磁珠分离技术与DNA自动提取工作站结合运用,以达到高效提取DNA的目的,它具有操作时间短、准确性高、检材用量少等特点,特别适用于大批量生物检材的快速提取,是目前主流的DNA自动化提取方法。本文对磁珠DNA自动提取系统的基本组成、工作原理、操作流程及其在法医检验领域中的应用等进行了综述,并对该系统的发展前景进行了展望。  相似文献   

12.
This preliminary study compares the benzodiazepine results for 10 post-mortem scalp hair samples using a classical solid-phase extraction (SPE) and a molecularly imprinted solid-phase extraction (MISPE) system. The hair samples selected for testing were from drug-related deaths where a positive benzodiazepine blood result was obtained. Samples were decontaminated with 0.1% sodium dodecyl sulfate, distilled water and dichloromethane, incubated overnight in methanol/25% aqueous ammonium hydroxide (20:1), extracted by SPE or MISPE and subsequently analysed by liquid chromatography-tandem mass spectrometry (LC-MS-MS). Both extraction methods detected diazepam, nordiazepam, oxazepam, temazepam and nitrazepam in the samples. Diazepam was detected in a greater number of samples using MISPE due to both its lower limit of detection (LOD) and higher extraction recovery as a result of excellent molecular recognition of the template (diazepam) imparted by the imprinting process. The selective recognition of two diazepam analogues, nordiazepam and oxazepam, was demonstrated using MISPE since they were also detected in a greater number of samples. In contrast, another diazepam analogue, temazepam, was detected in a greater number of samples using SPE since the LOD using this extraction was lower than with MISPE. Nitrazepam was detected in one sample using both extraction methods. Overall the MISPE and SPE hair results were in good qualitative agreement. For the samples, where both extraction methods detected nordiazepam, temazepam and oxazepam, the concentrations were always higher for SPE. This is probably due to the MIP procedure producing extracts with fewer matrix interferences than the extracts produced using the classical SPE method. MISPE could be used as a complementary method to classical SPE for the analysis of benzodiazepine positive hair samples collected from chronic users.  相似文献   

13.
The unlabeled antibody (PAP) immunoperoxidase technique was applied to the ABO blood grouping of human scalp hairs. Hair samples were subjected to longitudinal- or cross-sectioning, thus obtaining suitable samples for subsequent immunostaining. The immunostaining was carried out using rabbit anti-A and anti-B sera as the primary antibodies. With this technique, the group-specific staining which is revealed as a dark brown precipitate was clearly observed within the medullae of the hair shaft, and depending on the presence or absence of these precipitates, respective blood groups of unknown hair samples were determined. At the hair root, on the other hand, positive stainings were observed not only in medullary cells but also in some cortical cells of the keratogenous zone. From the present study, it can be safely said that this technique is of practical use for the ABO blood grouping from a minute (less than 3 mm) hair sample.  相似文献   

14.
国产磁珠结合自动化工作站批量提取生物检材DNA的应用   总被引:3,自引:4,他引:3  
目的建立国产磁珠结合自动化工作站批量提取案件中生物检材DNA的方法。方法采用国产磁珠结合Bio-Robert Universal System自动化工作站对案件中常见的生物样本进行DNA提取,检测Identifiler系统16个STR基因座,在ABI3130XL遗传分析仪上进行STR分型。其中210份样品同时在ABI7500型荧光定量PCR仪上进行定量。结果9100份10类生物检材应用国产磁珠结合自动化工作站,大部分可提取到足够的DNA进行STR检验。STR检验成功率最高的为口腔拭子、肌肉,达100%,接触细胞检材的成功率较低,为50.0%。结论国产磁珠结合自动化工作站可用于案件中常见的大部分生物样本的DNA提取。  相似文献   

15.
The potential to recover genetic profiles from evidence samples has substantially increased since robust and sensitive amplification kits are commercially available. Nevertheless, even the best amplification kits cannot succeed when the extracted DNA is of poor quality. In this study we compared the efficiency of silica (QIAamp DNA Mini Kit), Chelex and Phenol-Chloroform (PC) based protocols to recover DNA from different categories of samples (blood and saliva on cotton swabs, muscles, cigarette butts, saliva on foods and epidermal cells on clothes). The efficiency of the QIAamp system was improved when samples were treated with QIAshredder homogenizing columns. Overall, conventional Chelex or PC protocols allowed to recover conclusive SGM Plus profiles for 61% of the samples considered in this study. Contrastingly, 82% of them were successfully genotyped after being treated with a combination of QIAshredder and QIAamp systems. Our results further suggested that the QIAshredder/QIAamp protocol was particularly helpful to analyze evidence samples with few DNA and/or that were collected on substrates containing PCR inhibitors.  相似文献   

16.
17.
In our laboratory, analysis of human hair for the detection of drugs of abuse was first performed in 1995. Initially, requests for hair analysis were few, and it is only since 1997 that these analyses have become routine. As demand grew, we developed an automatic solid-phase extraction method; the use of a robot ASPEC allowed us to drop certain fastidious manipulations, and to treat a large number of samples at a time. This method is described, along with analysis by gas-chromatography-mass spectrometry (GC/MS) in selected ion monitoring mode (SIM), for the following drugs: codeine, 6-monoacetylmorphine (6-MAM), morphine, cocaine, methadone, ecstasy (MDMA) and Eve (MDE). This requires prior derivatization with propionic anhydride. The different validation parameters, linearity, repeatability, recovery and detection limits are described, as well as the application of this method to some real cases. Analysis of these cases is also performed by an ion trap GC/MS in chemical ionization mode (GC/IT/CI/MS) in order to demonstrate the usefulness of this technique as a complement to routine analysis. Analysis by GC/IT/CI/MS indeed avoids the risk of false-positive results by the identification of metabolites.  相似文献   

18.
The present paper describes a qualitative and quantitative method for the simultaneous detection of opiates, cocaine and benzoylecgonine from human hair samples. Every step of the analytical procedure was studied to find the optimized conditions. Nine different incubation systems were examined. The influence of different pH values of samples on the isolation of analytes from the incubation media by Bond Elut cartridges and the stability of the compounds of interest in the different incubation media and conditions were investigated. The extracting power of different incubation media was studied as well. The phosphate buffer 0.1 N at pH 5 was chosen as the extraction medium in an optimized procedure for simultaneous determination of opiates, cocaine and benzoylecgonine in hair samples. The method developed was validated. Recoveries were 90% for morphine (M), 81% for 6-monoacetylmorphine (6-AM), 90% for codeine (CD), 86% for cocaine (C) and 90% for benzoylecgonine (BE). Relative standard deviation for inter-day precision was better than 12%. The limits of detection resulted as 0.05 ng/mg for M and C, as 0.08 for 6-AM and as 0.2 ng/mg for BE. Forty hair samples collected from drug abusers admitted to centers for detoxification treatment were analyzed obtaining 23 positive results for opiates and/or cocaine. Twelve hair specimens longer than 10 cm were analyzed following a sectional approach. In the six positive cases, it was interesting to find that the 6-AM/M ratio generally decreased for each sample from the proximal segment to the distal segments. Moreover, the 6-AM/M ratio was generally lower than 1 in the intermediate and distal segments.  相似文献   

19.
萃取方式对海洛因滥用者毛发中代谢物分析的影晌   总被引:1,自引:1,他引:1  
目的比较液相萃取和同相萃取对毛发中海洛因毒品代谢物分析的影响。方法对海洛因吸食者毛发和空白添加标准品毛发经甲醇超声后的提取液分别进行液相萃取、同相萃取,然后进行衍生化和GC/MS—SIM检测。结果利用同相萃取法对添加6-单乙酰吗啡的毛发进行萃取和测试,6-单乙酰吗啡的回收率为32.O%,相对标准偏差(RSD)为2.4%;而液相萃取回收率为52.6%,相对标准偏差(RSD)为4.6%。结论固相萃取较之液液萃取,有更好的重复性,更少的杂质干扰和有机溶剂消耗等优势,但甲醇超声液需要挥干后才能进行同相萃取,而且6-单乙酰吗啡的水解率高。  相似文献   

20.
An alternative simplified procedure for the genetic analysis of salivary protein complex (SPC) which eliminates the need for a specific concentrated parotid sample is proposed. After the technique is applied isoelectric focusing and protein detection is carried out by silver staining. The chance of exclusion of non-fathers for these systems in our population is 0.161711 for Pr, 0.07948 for Db, 0.07836 for Pa and 0.00995 for PIF. The total exclusion rate for these systems is 0.30042.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号