首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A new rapid DNA solution, the RapidHIT®ID, can accommodate two different sample cartridges, ACE, for the analysis of a single swab and EXT, for the analysis of DNA extracts. An efficient internal validation designed for low‐throughput rapid DNA is described. An evaluation of the EXT sample cartridge is also described. Each cartridge generated profiles with sufficient data quality to meet CODIS eligibility in fewer than 120 min. The results exhibited 100% correlation when compared to conventional DNA typing methods. Precision, reproducibility, stochastic, mixture, and contamination experiments produced expected results. Sensitivity of the ACE sample cartridge was acceptable for buccal swab analysis. The sensitivity of the EXT sample cartridge is discussed. The ACE validation and the EXT evaluation utilized a minimalist, cost‐saving, efficient design to generate a validated RapidHIT®ID instrument capable of producing genetic profiles from both extracted forensic DNA samples and buccal swab samples within 120 min.  相似文献   

2.
Abstract: Multiplex autosomal short tandem repeat (STR) genotyping enables researchers to obtain genetic information from ancient human samples. In this study, we tested newly developed AmpF?STR® MiniFiler? kit for autosomal STR analysis of ancient DNA (aDNA), using human femurs (n = 8) collected from medieval Korean tombs. After extracting aDNA from the bones, autosomal STR analyses were repeated for each sample using the AmpF?STR® MiniFiler? and Identifiler? kits. Whereas only 21.87% of larger‐sized loci profiles could be obtained with the Identifiler? kit, 75% of the same loci profiles were determined by MiniFiler? kit analysis. This very successful amplification of large‐sized STR markers from highly degraded aDNA suggests that the MiniFiler? kit could be a useful complement to conventional STR kit analysis of ancient samples.  相似文献   

3.
The Quantifiler® Trio Quantification Kit has been developed to quantify the total amount of amplifiable and human male DNA in samples and to estimate the extent of DNA degradation. To minimize the cost of DNA quantification, we evaluated kit performance using a reduced volume of reagents (1/10‐volume) using DNA samples of varying types and concentrations. Our results demonstrated concordance between the manufacturer's method and the low‐volume method for DNA quantification, DNA degradation index estimation, and human male DNA quantification. We confirmed the practical utility of the low‐volume method with 109 casework samples by evaluating short tandem repeat (STR) profiling success with respect to DNA quantity and quality. We also defined a cutoff value for DNA quantity to ensure reliable STR results. Using a reduced volume of reagents, 10 times more reactions per kit are possible; accordingly, this method reduces the cost of DNA quantification, while maintaining performance.  相似文献   

4.
A common problem in forensic DNA typing is PCR inhibition resulting in allele dropout and peak imbalance. In this paper, we have utilized the Plexor® real‐time PCR quantification kit to evaluate PCR inhibition. This is performed by adding increasing concentrations of various inhibitors and evaluating changes in melt curves and PCR amplification efficiencies. Inhibitors examined included calcium, humic acid, collagen, phenol, tannic acid, hematin, melanin, urea, bile salts, EDTA, and guanidinium thiocyanate. Results were plotted and modeled using mathematical simulations. In general, we found that PCR inhibitors that bind DNA affect melt curves and CT takeoff points while those that affect the Taq polymerase tend to affect the slope of the amplification curve. Mixed mode effects were also visible. Quantitative PCR results were then compared with subsequent STR amplification using the PowerPlex® 16 HS System. The overall results demonstrate that real‐time PCR can be an effective method to evaluate PCR inhibition and predict its effects on subsequent STR amplifications.  相似文献   

5.
Qiagen's Investigator? Quantiplex kit, a total human DNA quantitation kit, has a 200‐base pair internal control, fast cycling time, and scorpion molecules containing a covalently linked primer, probe, fluorophore, and quencher. The Investigator? Quantiplex kit was evaluated to investigate a value under which complete short tandem repeat (STR) failure was consistently obtained. Buccal swabs were extracted using the Qiagen QIAamp® DNA Blood Mini Kit, quantified with the Investigator? Quantiplex kit using a tested half‐volume reaction, amplified with the ABI AmpFlSTR® Identifiler kit, separated on the 3100Avant Genetic Analyzer, and data analyzed with GeneMapper® ID v.3.2. While undetected samples were unlikely to produce sufficient data for statistical calculations or CODIS upload (2.00 alleles and 0.82 complete loci on average), data may be useful for exclusionary purposes. Thus, the Investigator? Quantiplex kit may be useful for predicting STR success. These findings are comparable with previously reported data from the Quantifiler? Human kit.  相似文献   

6.
Abstract: The quality and efficiency of a standard organic DNA isolation method and a silica‐based method using the QIAGEN Blood Maxi Kit were compared to obtain human DNA and short tandem repeats (STRs) profiles from 39 exhumed bone samples for paternity testing. DNA samples were quantified by real‐time PCR, and STR profiles were obtained using the AmpFlSTR® Identifiler® PCR amplification kit. Overall, the silica‐based method recovered less DNA ranging from 0 to 147.7 ng/g (average 7.57 ng/g, median = 1.3 ng/g) than did the organic method ranging from 0 to 605 ng/g (average 44.27 ng/g, median = 5.8 ng/g). Complete profiles (16/16 loci tested) were obtained from 37/39 samples (95%) using the organic method and from 9/39 samples (23%) with the silica‐based method. Compared with a standard organic DNA isolation method, our results indicate that the published silica‐based method does not improve neither the quality nor the quantity of DNA for STR profiling.  相似文献   

7.
Psilocybe cubensis, or “magic mushroom,” is the most common species of fungus with psychedelic characteristics. Two primer sets were designed to target Psilocybe DNA using web‐based software and NBCI gene sequences. DNA was extracted from eighteen samples, including twelve mushroom species, using the Qiagen DNeasy® Plant Mini Kit. The DNA was amplified by the polymerase chain reaction (PCR) using the primers and a master mix containing either a SYBR® Green I, Radiant? Green, or LCGreen Plus® intercalating dye; amplicon size was determined using agarose gel electrophoresis. The PCR assays were tested for amplifiability, specificity, reproducibility, robustness, sensitivity, and multiplexing with primers that target marijuana. The observed high resolution melt (HRM) temperatures for primer sets 1 and 7 were 78.85 ± 0.31°C and 73.22 ± 0.61°C, respectively, using SYBR® Green I dye and 81.67 ± 0.06°C and 76.04 ± 0.11°C, respectively, using Radiant? Green dye.  相似文献   

8.
The goal of this work was to optimize and validate a fast amplification protocol for the multiplex amplification of the STR loci included in AmpFlSTR® Profiler Plus® to expedite human DNA identification. By modifying the cycling conditions and by combining the use of a DNA polymerase optimized for high speed PCR (SpeedSTAR™ HS) and a more efficient thermal cycler instrument (Bio-RAD C1000™), we were able to reduce the amplification process from 4 h to 26 min. No modification to the commercial AmpFlSTR® Profiler Plus® primer mix was required. When compared to the current Royal Canadian Mounted Police (RCMP) amplification protocol, no differences with regards to specificity, sensitivity, heterozygote peak height ratios and overall profile balance were noted. Moreover, complete concordance was obtained with profiles previously generated with the standard amplification protocol and minor alleles in mixture samples were reliably typed. An increase in n − 4 stutter ratios (2.2% on average for all loci) was observed for profiles amplified with the fast protocol compared to the current procedure. Our results document the robustness of this rapid amplification protocol for STR profiling using the AmpFlSTR® Profiler Plus® primer set and demonstrate that comparable data can be obtained in substantially less time. This new approach could provide an alternative option to current multiplex STR typing amplification protocols in order to increase throughput or expedite time-sensitive cases.  相似文献   

9.
European forensic laboratories are replacing the STR multiplex kits with the new generation 16/17 STR kits. This study examines the influence of the new generation kits and the new Applied Biosystems 3500xL Genetic Analyzer on the designation of long D2S1338 and D19S433 off‐ladder alleles. Different allele calls were obtained using the new NGM? (Applied Biosystems) and PowerPlex® ESI? (Promega) kits compared with AmpF?STR® SGM Plus? kit (Applied Biosystems). Sequence analysis was used to determine accurate allele designation. The new multiplex kits and the 3500xL Genetic Analyzer improved accuracy of long allele designations. DNA databases worldwide include countless profiles obtained by previous kits. Discrepancies between the new and former technologies may cause failure to detect hits. Discordance is expected due to primer sequence differences between various kits. An additional discordance, occurring in long alleles, independent of primer sequence is reported in this study.  相似文献   

10.
Abstract:  With <100 pg of template DNA, routine short tandem repeat (STR) analysis often fails, resulting in no or partial profiles and increased stochastic effects. To overcome this, some have investigated preamplification methods that include the addition of proofreading enzymes to the PCR cocktail. This project sought to determine whether adding proofreading polymerases directly in the STR amplification mixture would improve the reaction when little template DNA is available. Platinum Taq High Fidelity and GeneAmp High Fidelity were tested in Profiler Plus? STR reactions alone and in combination with AmpliTaq® Gold. All reactions included the additional step of a post‐PCR purification step. With both pristine low template DNA and casework samples, the addition of these polymerases resulted in comparable or no improvement in the STR amplification signal. Further, stochastic effects and artifacts were observed equally across all enzyme conditions. Based on these studies, the addition of these proofreading enzymes to a multiplex STR amplification is not recommended for low template DNA work.  相似文献   

11.
Abstract: DNA mixtures with two or more contributors are a prevalent form of biological evidence. Mixture interpretation is complicated by the possibility of different genotype combinations that can explain the short tandem repeat (STR) data. Current human review simplifies this interpretation by applying thresholds to qualitatively treat STR data peaks as all‐or‐none events and assigning allele pairs equal likelihood. Computer review, however, can work instead with all the quantitative data to preserve more identification information. The present study examined the extent to which quantitative computer interpretation could elicit more identification information than human review from the same adjudicated two‐person mixture data. The base 10 logarithm of a DNA match statistic is a standard information measure that permits such a comparison. On eight mixtures having two unknown contributors, we found that quantitative computer interpretation gave an average information increase of 6.24 log units (min = 2.32, max = 10.49) over qualitative human review. On eight other mixtures with a known victim reference and one unknown contributor, quantitative interpretation averaged a 4.67 log factor increase (min = 1.00, max = 11.31) over qualitative review. This study provides a general treatment of DNA interpretation methods (including mixtures) that encompasses both quantitative and qualitative review. Validation methods are introduced that can assess the efficacy and reproducibility of any DNA interpretation method. An in‐depth case example highlights 10 reasons (at 10 different loci) why quantitative probability modeling preserves more identification information than qualitative threshold methods. The results validate TrueAllele® DNA mixture interpretation and establish a significant information improvement over human review.  相似文献   

12.
PowerPlex® Y23 is a novel kit for Y‐STR typing that includes new highly discriminating loci. The Israel DNA Database laboratory has recently adopted it for routine Y‐STR analysis. This study examined PCR amplification from 1.2‐mm FTA punch in reduced volumes of 5 and 10 μL. Direct amplification and washing of the FTA punches were examined in different PCR cycle numbers. One short robotically performed wash was found to improve the quality and the percent of profiles obtained. The optimal PCR cycle number was determined for 5 and 10 μL reaction volumes. The percent of obtained profiles, color balance, and reproducibility were examined. High‐quality profiles were achieved in 90% and 88% of the samples amplified in 5 and 10 μL, respectively, in the first attempt. Volume reduction to 5 μL has a vast economic impact especially for DNA database laboratories.  相似文献   

13.
STR typing of DNA evidence can identify the donor with a high power of discrimination but cannot identify the tissue origin of a body‐fluid stain. Using RNA to attribute a crime scene stain to a particular tissue may aid in reconstruction efforts. With blood from 10 donors, four DNA and RNA coextraction kits were evaluated by measuring yields and STR and mRNA profiles. T tests indicated some significant differences in kit performance. The Zymo Research ZR‐Duet? kit performed best based on average DNA (41.4 ng) and mRNA (4.07 ng) yields and was the only kit to provide complete DNA/RNA profiles for all samples. The consistency of this kit was challenged by data from additional blood and saliva donors. Further testing is advised before a superior kit is unequivocally chosen. Stand‐alone DNA or RNA purification generally offers higher yield, but coextraction may still allow successful STR profiling and tissue source identification.  相似文献   

14.
Abstract:  The male‐specific Y‐chromosomal short tandem repeat (STR) is a useful tool in forensic casework. The Y haplotype comprised of 16 loci, which is amplified simultaneously by AmpFlSTR® YfilerTM PCR kit and provides strong exculpatory evidence in individual identification. We reported a rare Y‐STR profile with a null allele at the DYS448 locus and an off‐ladder allele at the DYS456 locus, when genotyping material from a vaginal swab in an alleged rape case. Sequence analysis revealed that the DYS448 null allele was a true type of null allele because of a total deletion of 11 upstream repeats and 9 bp of the N42 region, and there were numerous primer binding site mutations as well. The amplicon of the DYS456 locus was a small 92‐bp fragment that was off‐ladder, and sequencing analysis showed that there were only 10 repeats (AGAT)10. This Y chromosome haplotype that was comprised of two variations provided helpful evidence for personal identification.  相似文献   

15.
Abstract: This paper reports the results of a commission to develop a field deployable rapid short tandem repeat (STR)‐based DNA profiling system to enable discrimination between tissues derived from a small number of individuals. Speed was achieved by truncation of sample preparation and field deployability by use of an Agilent 2100 BioanalyserTM. Human blood and tissues were stabbed with heated stainless steel wire and the resulting sample dehydrated with isopropanol prior to direct addition to a PCR. Choice of a polymerase tolerant of tissue residues and cycles of amplification appropriate for the amount of template expected yielded useful profiles with a custom‐designed quintuplex primer set suitable for use with the BioanalyserTM. Samples stored on wires remained amplifiable for months, allowing their transportation unrefrigerated from remote locations to a laboratory for analysis using AmpFlSTR® Profiler Plus® without further processing. The field system meets the requirements for discrimination of samples from small sets and retains access to full STR profiling when required.  相似文献   

16.
Forensic evidence samples are routinely found as stains on various substrates, which may contain substances known to inhibit polymerase chain reaction (PCR). The goal of this study was to evaluate post‐Chelex®100 purification using powdered activated carbon (PAC). Mock crime scene DNA extracts were analyzed using quantitative PCR and short tandem repeat (STR) profiling to test the DNA recovery and inhibitor removal using PAC with those of the Amicon®Ultra 100K. For extracted bloodstains on soil and wood substrates, PAC and Amicon®Ultra 100K generated similar DNA yield and quality. Moreover, the two methods significantly decreased the concentration of humic substances and tannins compared to nonpurified extracts (< 0.001). In instances where extracts contained indigo dye (bloodstains on denim), Amicon®Ultra 100K performed better than PAC due to improved amplifiability. Efficient adsorption of humic substances and tannins, which are common inhibitors, indicates PAC's potential application in the purification of high‐template DNA extracts.  相似文献   

17.
Next‐generation sequencing technologies enable the identification of minor mitochondrial DNA variants with higher sensitivity than Sanger methods, allowing for enhanced identification of minor variants. In this study, mixtures of human mtDNA control region amplicons were subjected to pyrosequencing to determine the detection threshold of the Roche GS Junior® instrument (Roche Applied Science, Indianapolis, IN). In addition to expected variants, a set of reproducible variants was consistently found in reads from one particular amplicon. A BLASTn search of the variant sequence revealed identity to a segment of a 611‐bp nuclear insertion of the mitochondrial control region (NumtS) spanning the primer‐binding sites of this amplicon (Nature 1995;378:489). Primers (Hum Genet 2012;131:757; Hum Biol 1996;68:847) flanking the insertion were used to confirm the presence or absence of the NumtS in buccal DNA extracts from twenty donors. These results further our understanding of human mtDNA variation and are expected to have a positive impact on the interpretation of mtDNA profiles using deep‐sequencing methods in casework.  相似文献   

18.
Abstract: Archived slides of cell smears treated with histological stains for sperm detection are often the only source of DNA available when cold cases are reopened. There have been conflicting reports as to the negative effects of particular histological stains on DNA recovery and quality from human cells, making stain selection an important consideration for forensic laboratories. This study investigates the effect of several staining systems on DNA recovery from histological slide samples stored from 0 to 10 weeks. DNA profiles obtained after analysis of these samples with AmpFlSTR® Identifiler? and increased cycle AmpFlSTR® SGM Plus? short tandem repeat (STR) profiling systems and the effects that these stains have on DNA quantity and quality over time are described. Results indicate that Christmas Tree and Hematoxylin and Eosin stains do not have significantly different effects on DNA quality after 10‐week storage of slides. This research will assist scientists to select staining systems that have minimal deleterious effects on the DNA recovered.  相似文献   

19.
Abstract: Laboratory automation has the ability to increase the throughput and efficiency of laboratory processes to keep pace with current backlogs and requests for analysis. This paper addresses the specific studies employed to properly evaluate an automated method for DNA quantitation setup using Applied Biosystems Quantifiler? Human DNA Quantification kit on a Biomek® 3000. The calibration of robotic pipetting as well as comparison with manually performed steps confirmed the accuracy of the automated methods used. Reproducibility studies evaluated differences between robotic and manually prepared human DNA standard curves. Additional studies examined DNA samples of known quantities, extract storage formats, sensitivity, and an assessment of contamination. The Biomek® 3000 not only demonstrated reproducibility and accuracy that equaled or surpassed the manual method but also revealed a contamination‐free method to replace the multiple pipetting steps required during quantitation setup.  相似文献   

20.
Abstract: Obtaining complete short tandem repeat (STR) profiles from fingerprints containing minimal amounts of DNA, using standard extraction techniques, can be difficult. The aim of this study was to evaluate a new kit, Fingerprint DNA Finder (FDF Kit), recently launched for the extraction of DNA and STR profiling from fingerprints placed on a special device known as Self‐Adhesive Security Seal Sticker® and other latent fingerprints on forensic evidentiary material like metallic guns. The DNA extraction system is based on a reversal of the silica principle, and all the potential inhibiting substances are retained on the surface of a special adsorbent, while nucleic acids are not bound and remain in solution dramatically improving DNA recovery. DNA yield was quite variable among the samples tested, rendering in most of the cases (>90%) complete STR profiles, free of PCR inhibitors, and devoid of artifacts. Even samples with DNA amount below 100 pg could be successfully analyzed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号