首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 343 毫秒
1.
This study originated from discussions and recommendations of the Technical Working Group on DNA Analysis Methods (TWGDAM). Four bloodstain deoxyribonucleic acid (DNA) extraction protocols and five semen stain DNA extraction protocols were evaluated. Nine laboratories participated in the extraction of DNA from 20 bloodstains and 20 semen stains using each protocol. All blood and semen stains originated from a single donor and were prepared under uniform conditions to permit the direct comparison of DNA yields and restriction fragment lengths. The extracted DNA from approximately 600 bloodstains and 700 semen stains was quantified by yield gel analysis and a slot blot hybridization technique. The extracted DNA was digested and restriction fragment length polymorphism (RFLP) patterns were generated using three single-locus probes. The RFLP sizing data produced from the blood and semen stains were evaluated with respect to (1) DNA extraction method, (2) gel length, (3) agarose type, (4) presence or absence of ethidium bromide in the gel, and (5) fragment sizes obtained from DNA isolated directly from the donor's liquid blood. This study demonstrates conclusively that high-molecular-weight DNA can be isolated using either organic or nonorganic DNA extraction protocols and that the resulting RFLP sizes are highly reproducible regardless of gel length, agarose type, or presence/absence of ethidium bromide.  相似文献   

2.
The purpose of this work was to conduct a comparative study of the sensitivity and specificity of phenolphthalein, tetramethylbenzidine, leucomalachite green, and orthotolidine as presumptive tests for blood. The findings of this study indicate that the phenolphthalein and the leucomalachite green tests are the most specific and that the tetramethylbenzidine and orthotolidine tests are the most sensitive of the group. The author concludes that the phenolphthalein test is the best single test for evaluating suspected bloodstains.  相似文献   

3.
A novel approach to the presumptive screening of questioned semen stains has been developed which enables the rapid identification of stains which are devoid of semen. Questioned semen stains can be swabbed with a moist cotton swab, and the prostatic acid phosphatase (SAP) activity transferred to the swab identified through assay with 5-bromo-4-chloro-3-indolyl phosphate (BCIP). Controlled laboratory studies revealed that the BCIP swab procedure was as sensitive as the semiquantitative SAP test currently employed in the FBI Laboratory for the presumptive screening of semen stains. A validation study of the BCIP swab procedure in parallel with the current procedure using 4305 case evidence stains indicated that the BCIP swab procedure was as effective as the current procedure in identifying those questioned stains which lack semen. The advantage of the BCIP swab procedure is that it can be performed on questioned stains in situ and thereby avoids the requirement of removing and extracting the stain before assay of SAP activity.  相似文献   

4.
Preliminary tests for the detection of stains at crime scenes aim to focus the police work making them more efficient in the combat of criminality. The application of the luminol chemiluminescence reaction (3-aminoftalhidrazida) in presumptive tests for the detection of bloodstains is known for more than 40 years in forensic science. This reaction is based on the emission of light through the chemical reaction of luminol mixed with hydrogen peroxide and a hydroxide in the presence of a catalytic molecule (iron from the hemoglobin) (Laux [1]).This work evaluates the luminol interference and its effect on subsequent serological and DNA testing. Samples prepared with blood and different concentrations of luminol solution containing luminol, peroxide of hydrogen and sodium carbonate, were analyzed. Additionally, samples of serial dilutions of standard DNA mixed with luminol solution were also analyzed. Although presumptive tests with luminol do not establish the characterization and identification of stains at crime scenes, preliminary results indicated that it is suitable for the detection of invisible bloodstains for forensic analysis, with few detrimental effects on the serological tests and subsequent DNA recovery and typing.  相似文献   

5.
A presumptive reagent for dilute blood detection other than luminol is fluorescein. The sensitivity of fluorescein approaches the sensitivity of detection levels of luminol. The fluorescein detection method offers the advantages of working in a lighted environment, and the reaction persists longer than luminol. A series of diluted bloodstains, ranging from neat to 1:1,000,000, was placed on a variety of substrates. Three sets were made per substrate. One set was exposed to fluorescein, one set was exposed to luminol, and one set served as an uncontaminated control. The fluorescein signal persisted longer than luminol. However, background staining for fluorescein was observed on some substrates within 30 s to 1 min, and no background staining was observed for luminol. Stains on non-absorbent surfaces were detectable at 1:100,000 dilutions, and stains on absorbent surfaces were detectable usually at no more than 1:100. The sensitivity of detection of fluorescein was comparable to that of luminol in this study. In all cases, where sufficient DNA was recovered, typeable results at all 13 core CODIS STR loci were obtained from treated bloodstains and controls. The results from STR typing indicate that there was no evidence of DNA degradation.  相似文献   

6.
When bloodstains are detected at crime scene using presumptive tests (e.g. luminol, phenolphthalein, leuchomalachite green), it is important to establish the real human nature of each stain. This is possible using confirmatory tests. One of these is rapid stain identification-blood (RISD-blood) a lateral flow immuno-chromatographic strip test format which allows the identification of human blood by detection of glycophorin A, a red blood cell membrane antigen, using two anti-human glycophorin A (GPA) monoclonal antibodies.The aim of this study is to assess the sensitivity of RSID-blood test in old, degraded bloodstains and in some bloodstains previously treated with BlueStar Forensic, a presumptive test which is often used in crime scene investigations to detect latent bloodstains. The genetic analysis of all bloodstains of confirmed human nature was subsequently performed using the AmpF1STR Identifiler PCR Amplification Kit (Applied Biosystems), to validate the possibility of obtain a consistent and reliable DNA typing results.  相似文献   

7.
This study was designed to test the following factors involved with processing luminol treated bloodstained evidence: 1) The reactivity of other presumptive chemical color tests, phenolphthalin (PT) and tetramethylbenzidine (TMB), following the application of the light emitting luminol presumptive test. 2) The effect of different cleanings of various bloody substrates on the luminol test. 3) The effect of different cleanings of various bloody substrates on the ability to obtain DNA suitable for PCR testing. 4) The ability to extract DNA from luminol treated bloodstained substrates using three extraction techniques. 5) The effect of spraying washed and unwashed bloodstains on various substrates with luminol on the ability to correctly type the DNA using PCR. Our findings indicated that luminol did not adversely effect the PCR testing and did not interfere with the PT and TMB presumptive tests for blood. It was determined that the substrate and the method of cleaning were the major factors affecting DNA yield and the ability to type the bloodstains using PCR based technologies.  相似文献   

8.
The PrepFiler™ is a new kit recently introduced by Applied Biosystems for DNA extraction from a wide range of forensic samples. In the present study we tested the performance of PrepFiler™ kit against other commonly used commercially available kits on a variety of real forensic casework samples: bloodstains on different substrates, washed bloodstains, semen stains, saliva stains, hairs, bones, tissues, nails, prints after chemical treatments, skin swabs.  相似文献   

9.
Biological stains can be difficult to detect at crime scenes or on items recovered from crime scenes. The use of a versatile light source may assist in their detection. The ability of Polilight to locate potential semen, saliva, and blood stains on a range of substrates and at different dilutions was tested. We also tested the use of Polilight in comparison with conventional chemical-based presumptive screening tests such as acid phosphatase (AP), Phadebas, and luminol, often used in casework for detecting potential semen, saliva, and blood stains, respectively. The Polilight was able to locate stains that were not apparent to the naked eye. The color of the material on which a stain is deposited can have an effect on the detectibility of the stain. The Polilight was found to be comparable with the AP and Phadebas tests in terms of its sensitivity. In a comparative study between the AP test and Polilight on 40 casework exhibits, one false-negative result was observed when using the Polilight. On a series of mock casework exhibits it was determined that the Polilight can be used successfully to locate saliva stains for DNA analysis. The sensitivity of luminol for detecting potential bloodstains was greater than that of Polilight; however the Polilight has particular application in instances where a bloodstain may have been concealed with paint. Overall, the Polilight is a relatively safe, simple, noninvasive, and nondestructive technique suitable for use in forensic casework.  相似文献   

10.
Presumptive tests for blood play a critical role in the examination of physical evidence and in the determination of subsequent analysis. The catalytic power of hemoglobin allows colorimetric reactions employing phenolphthalein (Kastle‐Meyer test) to indicate “whether” blood is present. Consequently, DNA profiles extracted from phenolphthalein‐positive stains are presumed to be from blood on the evidentiary item and can lead to the identification of “whose” blood is present. Crushed nodules from a variety of legumes yielded phenolphthalein false‐positive reactions that were indistinguishable from true bloodstains both in color quality and in developmental time frame. Clothing and other materials stained by nodules also yielded phenolphthalein false‐positive reactivity for several years after nodule exposure. Nodules from leguminous plants contain a protein (leghemoglobin) which is structurally and functionally similar to hemoglobin. Testing of purified leghemoglobin confirmed this protein as a source of phenolphthalein reactivity. A scenario is presented showing how the presence of leghemoglobin from nodule staining can mislead investigators.  相似文献   

11.
Extracts of vaginal swabs free of both blood and semen, collected from three donors throughout several menstrual cycles, have been examined by cellulose acetate membrane electrophoresis for the presence of lactate dehydrogenase (LDH) isozymes. LDH activity, predominantly in the form of LDH-5 was detected in some extracts. Mixtures of these particular extracts with peripheral blood gave LDH patterns similar to those observed for menstrual blood. The results indicate that LDH isozyme patterns cannot be used to differentiate between stains of menstrual blood and bloodstains that have become mixed or contaminated with vaginal secretions.  相似文献   

12.
In this study, DNA was extracted using an AutoMate Express? and an EZ1 Advanced XL from liquid blood, fresh and aged bloodstains, and fresh and aged semen stains. Extracted DNA was quantified by real‐time PCR using the D17Z1 locus. Short tandem repeat typing was performed using an AmpF?STR® Identifiler kit. The yields of DNA obtained by the AutoMate Express? were higher from fresh bloodstains and fresh semen stains, almost the same from aged bloodstains and aged semen stains, but slightly lower from liquid blood compared with those obtained by the EZ1 Advanced XL. The addition of dithiothreitol or the use of PrepFiler? lysis buffer improved the EZ1 Advanced XL results from fresh bloodstains, but not for liquid blood and aged bloodstains. Our results demonstrated that the PrepFiler? lysis buffer is the main contributor to the higher DNA yields of the AutoM ate Express? for fresh bloodstains.  相似文献   

13.
Human erythrocyte peptidase A (Pep A) displays a genetic polymorphism in blacks. Its occurrence in human semen was examined for its possible use as a semen typing system. Studies by starch gel electrophoresis, in which the Pep A was located by an improved method, were carried out on semen, semen stains, and vaginal swabs taken at known times after intercourse. In addition, a large number of vaginal swabs, negative for semen, were taken from females throughout their menstrual cycles and examined for Pep A activity. The results indicated that Pep A typing could be carried out on semen and semen stains. However, it was possible to determine the Pep A type on vaginal swabs only when they had been taken within about 3 h after intercourse.  相似文献   

14.
In recent years the forensic scientist has been afforded great advances in technology both in the detection of latent bloodstains and in acquiring reliable DNA typing results from very small pieces of physical evidence. Scientists are now able to detect minute quantities of latent bloodstains by utilizing the luminol reagent, oftentimes indicating that an attempt has been made to conceal any evidence of bloodshed. With the introduction of PCR based technology to the forensic arena, scientists are now routinely able to obtain DNA typing results from previously insufficient amounts of biological material, items as small as a single hair, saliva on a cigarette butt, or a bloodstain the size of a pin head. We present here a merging of these two advances coupled with a new collection medium for post luminol treated latent bloodstains. The forensic scientist is now able to routinely isolate and recover an adequate amount of DNA suitable for PCR typing at all of the Promega GenePrint PowerPlex 1.1 loci. In this study, several dilutions of latent bloodstains were prepared in an effort to simulate transferred bloodstains that are routinely encountered in a crime scene setting. The latent bloodstains were treated with luminol and subsequently collected using conventional cotton tipped swabs as well as a Puritan sponge tipped swab. PCR typing at the Promega GenePrint PowerPlex 1.1 loci was then attempted upon all dilutions of the latent bloodstains for both collection mediums. The results clearly indicate that it is now routinely possible to recover adequate amounts of DNA suitable for PCR typing upon post luminol treated bloodstains.  相似文献   

15.
Luminol, leuchomalachite green, phenolphthalein, Hemastix, Hemident, and Bluestar are all used as presumptive tests for blood. In this study, the tests were subjected to dilute blood (from 1:10,000 to 1:10,000,000), many common household substance, and chemicals. Samples were tested for DNA to determine whether the presumptive tests damaged or destroyed DNA. The DNA loci tested were D2S1338 and D19S433. Leuchomalachite green had a sensitivity of 1:10,000, while the remaining tests were able to detect blood to a dilution of 1:100,000. Substances tested include saliva, semen, potato, tomato, tomato sauce, tomato sauce with meat, red onion, red kidney bean, horseradish, 0.1 M ascorbic acid, 5% bleach, 10% cupric sulfate, 10% ferric sulfate, and 10% nickel chloride. Of all the substances tested, not one of the household items reacted with every test; however, the chemicals did. DNA was recovered and amplified from luminol, phenolphthalein, Hemastix, and Bluestar, but not from leuchomalachite green or Hemident.  相似文献   

16.
应用‘Myo’小卫星 DNA 探针,Southern 印迹杂交技术,对血斑、精斑、同一个体不同组织进行 DNA 指纹图分析,均获得清晰的图谱。同一个体的血斑与血液、精斑与精液以及不同的组织其 DNA 指纹图谱完全相同。可以根据斑痕或组织与嫌疑个体的血液或某一组织 DNA 的指纹图谱比对以做出同一认定。50μl 血液量的血斑、5μl 精液量的精斑可以获得清晰易辨的指纹图谱。五年的精斑、两年的血斑亦可做出与同源个体新鲜精液、血液完全一致的 DNA 指纹图谱。对杀人、强奸杀人、碎尸等不同案件的血痕、精斑、不同组织碎块进行了 DNA 指纹图检验,均做出了正确的个体认定。本方法的应用为我国法医物证检验提供了新的分析手段,使个体认定得以实现。  相似文献   

17.
Saliva and saliva-stained materials were examined as potential sources of deoxyribonucleic acid (DNA) for DNA analysis and identity testing. In this paper, the authors demonstrate that DNA was isolated and DNA banding patterns suitable for DNA typing were obtained from fresh saliva and various saliva-stained materials, such as envelopes, buccal swabs, gags, and cigarettes. Furthermore, DNA and DNA banding patterns were obtained from actual forensic evidentiary samples containing mixed saliva/semen stains. The DNA banding patterns obtained from saliva or saliva-stained material were indistinguishable from the patterns obtained from blood or hair from the same individual. Intact DNA was readily isolated and DNA banding patterns were obtained from saliva stored at -20 degrees C and dried saliva stains stored under varying conditions. We conclude that saliva and saliva-stained material can be good sources of DNA for analysis and for DNA typing in certain forensic settings.  相似文献   

18.
Abstract: It is common in forensic casework to encounter situations where the suspect has set a fire to cover up or destroy possible evidence. While bloodstain pattern interpretation, chemical enhancement of blood, and recovery of deoxyribonucleic acid (DNA) from bloodstains is well documented in the literature, very little information is known about the effects of heat or fire on these types of examinations. In this study, a variety of known types of bloodstain patterns were created in a four‐room structure containing typical household objects and furnishings. The structure was allowed to burn to flashover and then it was extinguished by firefighters using water. Once the structure cooled over night, the interior was examined using a bright light. The bloodstains were evaluated to see if the heat or fire had caused any changes to the patterns that would inhibit interpretation. Bloodstain patterns remained visible and intact inside the structure and on furnishings unless the surface that held the blood was totally burned away. Additionally, a variety of chemical techniques were utilized to better visualize the patterns and determine the possible presence of blood after the fire. The soot from the fire formed a physical barrier that initially interfered with chemical enhancement of blood. However, when the soot was removed using water or alcohol, the chemicals used, fluorescein, luminol, Bluestar®, and Hemastix®, performed adequately in most of the tests. Prior to DNA testing, the combined phenolphthalein/tetramethyl benzidine presumptive test for the presence of blood was conducted in the laboratory on samples recovered from the structure in an effort to assess the effectiveness of using this type of testing as a screening tool. Test results demonstrated that reliance on obtaining a positive presumptive result for blood before proceeding with DNA testing could result in the failure to obtain useful typing results. Finally, two DNA recovery methods (swabbing the stain plus cutting or scraping the stain) were attempted to evaluate their performance in recovering samples in an arson investigation. Recovery of DNA was more successful in some instances with the swabbing method, and in other instances with the cutting/scraping method. Therefore, it is recommended that both methods be used. For the most part, the recovered DNA seemed to be unaffected by the heat, until the temperature was 800°C or greater. At this temperature, no DNA profiles were obtained.  相似文献   

19.
This study was designed to analyze the effects of the environment and substrata on the quality of deoxyribonucleic acid (DNA) isolated from evidentiary specimens. The quality of DNA isolated from actual casework specimens was determined by measuring its size by agarose gel electrophoresis. The information obtained could be used to predict the suitability of the DNA in the samples for restriction fragment length polymorphism (RFLP) analysis. The evidentiary specimens chosen for DNA were classified according to substrate (scrapings, plastic bags, synthetics, denim, and carpet) and according to a subjective evaluation of the condition of the stain (soiled, damp, or putrefied) and to its size (small or large). The results show that DNA of sufficient quality and high molecular weight (HMW) can be reliably isolated from bloodstains deposited on evidentiary items which have an unknown environmental history and which have dried onto a variety of substrata. Subsequent RFLP analysis of a selected number of these samples verified that the DNA was suitable for this type of analysis.  相似文献   

20.
In forensics, bloodstains on dark fabrics might be invisible for the naked eye. Although several visualization, presumptive, and confirmatory blood tests have been developed, all have one or more disadvantages, especially on DNA analysis. We report here the use of a visualization assay that can visually detect blood drops up to 1/20 dilution. In this assay, the fabric is placed between two wet filter papers and covered by glass surfaces on both sides. Pressure is applied on the glass surfaces in which bloodstains transfer onto the filter papers through capillary forces. Detected stains can be tested with other more sensitive presumptive blood tests performed on the filter paper. Even more, DNA analysis can be performed on the transferred bloodstains. The presented visualization assay is easy to perform, extremely cheap, requires little hands on time, and does not affect bloodstain pattern analysis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号