首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Fentanyl deaths have increased with availability of transdermal patches. Interpretation of postmortem fentanyl levels may be complicated by postmortem redistribution and absorption of fentanyl from a patch. We applied an unused 100‐μg/h fentanyl patch onto the lower abdomen of a decedent with no premortem fentanyl exposure. Ocular fluid, blood, and urine were collected prior to placement, and the decedent was refrigerated for 23 h. Prior to the autopsy, urine, subcutaneous tissue under the patch, and samples from the same anatomic sites were obtained. We observed no fentanyl in any postpatch placement samples (LOD: 0.1 ng/mL for blood and vitreous fluid, 1.0 ng/mL urine, 2.0 ng/g for tissues). Although we observed no postmortem absorption of fentanyl, this was only a single case; therefore, we recommend that patches be removed after receipt of a cadaver before initiation of an autopsy, with the location of removed patch documented.  相似文献   

2.
Fentanyl transdermal patches have been used to treat cancer‐ and noncancer‐related chronic pain. However, its inappropriate or illegal application may cause fatal poisoning. We herein present the case of a Japanese woman in her 40s who was found dead with seven 25‐μg/h fentanyl transdermal patches on her body. We established a detailed toxicological analysis procedure to quantify fentanyl, and its metabolite norfentanyl, and other drugs (acetaminophen, allylisopropylacetylurea, celecoxib, estazolam, promethazine, and sertraline) in human whole blood by ultra‐high‐performance liquid chromatography–tandem mass spectrometry. The measured fentanyl and norfentanyl concentrations in the femoral and cardiac blood were 0.051 and 0.072 μg/mL and 0.033 and 0.076 μg/mL, respectively. The decedent's fentanyl concentrations were consistent with previously reported postmortem blood levels for fatal cases of poisoning by fentanyl transdermal patches. Based on the decedent's case history, autopsy findings, and toxicological analyses, the cause of death was identified as intoxication with transdermal fentanyl.  相似文献   

3.
Opioid‐related mortality happens, even in healthcare settings. We describe serial postmortem fentanyl blood concentrations in a hospital inpatient who fatally abused transdermal fentanyl. This is a single‐patient case report. A 42‐year‐old man with lymphoma was started on transdermal fentanyl therapy while hospitalized for chronic abdominal pain. The patient was last seen awake 1.3 h prior to being found apneic and cyanotic. During the resuscitation attempt, a small square‐shaped film was removed from the patient's oropharynx. Femoral blood was collected 0.5 and 2 h postmortem, and the measured fentanyl concentration increased from 1.6 to 14 ng/mL. Study limitations include potential laboratory or collection errors and missing data. (i) Providers must be vigilant for signs of fentanyl patch abuse. (ii) Postmortem blood concentrations are not static postmortem, likely secondary to decreasing pH, increased aqueous solubility, and tissue redistribution, and are therefore unlikely to accurately represent antemortem blood concentrations.  相似文献   

4.
Fentanyl is a synthetic opioid agonist used for pain control. Often administered as a transdermal patch, it is an interesting drug for study of postmortem redistribution. We hypothesized that fentanyl concentrations would increase over time after death, as measured in blood drawn on the day prior to autopsy and in blood drawn at the time of autopsy in ten cases where fentanyl patches were identified at the scene. Concentrations were compared, and heart blood to femoral blood ratios were calculated as markers of postmortem redistribution. Fentanyl concentrations measured in peripheral blood drawn the day of autopsy (peripheral blood 2 [PB2]) were higher than those drawn the day prior to autopsy (peripheral blood 1 [PB1]) with a mean ratio (PB2/PB1) of 1.80. The ratio of heart blood concentrations (HB) to femoral blood concentrations drawn at autopsy (PB2) had a mean ratio (HB/PB2) of 1.08. Some cases had blood from the same source analyzed at two different laboratories, and concentrations of fentanyl in those samples showed inter‐ and intralaboratory differences up to 25 ng/mL. Postmortem fentanyl concentrations may be affected by antemortem factors, postmortem redistribution, and laboratory variability. Forensic pathologists must use caution in interpreting fentanyl levels as part of death investigation.  相似文献   

5.
Matching dental antemortem (AM) and postmortem (PM) data for human identification is especially challenging when the workforce is limited. Dental hygienists have served mass fatality incidents (MFIs) due to dental-related expertise. However, forensics within dental hygiene education and research on transferable skills is limited. This qualitative balance design study assessed senior dental hygiene students' match accuracy of simulated cases varying in dental identifiers based on AM full mouth series (FMS) radiographs and oral photographs to PM WinID3® odontograms to demonstrate possible disaster victim identification (DVI) transferable skills gained during formal education. A convenience sample of senior dental hygiene students (n = 31) was presented information on WinID3® interpretation, then presented with 5 mismatched cases and asked to visually interpret each to make 10 total matches; five based on AM FMS with simulated PM WinID3® odontograms and five based on AM photographs with PM WinID3® odontograms. Match accuracy scores ranged from 41.9% to 58.1% for cases with 1–10 identifiers, and 77.4% to 93.5% for cases with 11–40 identifiers. Accuracy when matching AM radiographs to PM odontograms versus AM photographs to PM odontograms was compared and revealed no statistical differences in match accuracy depending on image type (p = 0.388 to 1.000). Results of this pilot study suggests transferable match accuracy skills resulted from the participants' dental hygiene formal education. These baseline skills with additional specialized training support the rationale for dental hygienists serving on DVI teams. More research is needed in education and practice when preparing dental hygienists for forensic-based service.  相似文献   

6.
Acetyl fentanyl is a Schedule I controlled synthetic opioid that is becoming an increasingly detected “designer drug.” Routine drug screening procedures in local forensic toxicology laboratories identified a total of 41 overdose deaths associated with acetyl fentanyl within multiple counties of the southwestern region of the state of Pennsylvania. The range, median, mean, and standard deviation of blood acetyl fentanyl concentrations for these 41 cases were 0.13–2100 ng/mL, 11 ng/mL, 169.3 ng/mL, and 405.3 ng/mL, respectively. Thirty‐six individuals (88%) had a confirmed history of substance abuse, and all but one case (96%) were ruled multiple drug toxicities. This report characterizes this localized trend of overdose deaths associated with acetyl fentanyl and provides further evidence supporting an alarmingly concentrated opiate and opioid epidemic of both traditional and novel drugs within this region of the United States.  相似文献   

7.
In forensic science, fingerprints are a common source of evidentiary information. However, latent examination is not always successful and trace human DNA cannot always be obtained. Thus, examining the fingerprint microbiome may offer a suitable alternative to more traditional methods of forensic identification. The Zymo Research ZR Bacterial/Fungal DNA MicroPrep™ Kit, Qiagen QIAmp® DNA Mini Kit, Promega Wizard® Genomic DNA Purification Kit, and the MPBio FastDNA® Spin Kit were compared for their ability to yield a sufficient amount of bacterial DNA for next-generation sequencing in order to obtain a microbiome profile. Prints were deposited onto slides, allowed to sit for up to 1 month, and total DNA isolated and quantified using each kit. The kit from Zymo Research yielded the most concentrated DNA sample (0.0084 ng/µL) in the least amount of time as compared to other kits examined. Although this amount of DNA was far below the recommended DNA concentration threshold recommended for next-generation sequencing, a microbiome profile was successfully obtained. As interest in using the microbiome of an individual as a forensic tool continues to increase, there is the possibility that the microbiome of a fingerprint could complement traditional human DNA profiling in the future. This study provides evidence that trace amounts of bacterial DNA from fingerprints is quantifiable and sufficient for microbiome analysis.  相似文献   

8.
Postmortem redistribution of fentanyl in the rabbit was investigated after application of the 50-μg/h Durogesic pain patch. Patches were applied for 48 hours. Two cycles of patch administration were used before characterization of the postmortem redistribution. Fentanyl showed marked redistribution into the femoral and pulmonary veins of the rabbit through 48 hours after the animals were humanely killed and the pain patches removed. The plasma concentration of 2.34 ng/mL in the femoral blood before killing the animals increased 5.6-fold by 48 hours after patch removal to 13.2 ng/mL. This postmortem concentration is approximately 3-fold the C(max) determined during antemortem pharmacokinetic analysis, 4 ng/mL, which was achieved 24 hours after the application of the second 50-μg/h Durogesic pain patch. After blood sampling for 48 hours after animal termination with patch removal compared with sampling for 48 hours from animals not terminated and with patch removal, the exposure ratios in the terminated animals were approximately 30-fold, indicating that between the postmortem redistribution of fentanyl and the cessation of hepatic clearance of fentanyl in the rabbit, the postmortem redistribution of fentanyl leads to an elevated measures of postmortem blood concentrations relative to antemortem blood concentrations.  相似文献   

9.
Dextromethorphan (DXM) is abused most commonly among adolescents as a recreational drug to generate a dissociative experience. The objective of the study was to assess driving with and without DXM ingestion. The effects of one‐time maximum daily doses of DXM 120 mg versus a guaifenesin 400 mg dose were compared among 40 healthy subjects using a crossover design. Subjects’ ability to drive was assessed by their performance in a driving simulator (STISIM® Drive driving simulator software) and by conducting a standardized field sobriety test (SFST) administered 1‐h postdrug administration. The one‐time dose of DXM 120 mg did not demonstrate driving impairment on the STISIM® Drive driving simulator or increase SFST failures compared to guaifenesin 400 mg. Doses greater than the currently recommended maximum daily dose of 120 mg are necessary to perturb driving behavior.  相似文献   

10.
Mitragyna speciosa (MS), a plant commonly known as kratom, is a widely used “legal high” opiate alternative for pain relief. DNA extracted from MS and 26 additional plant species was amplified by PCR using primers targeting the strictosidine beta-D-glucosidase (SGD) and secologanin synthase 2 (SLS2) genes and detected by high-resolution melt curves using three intercalating dyes. Amplicon sizes were confirmed using agarose gel electrophoresis. The observed melt temperatures for SGD and SLS2 were 77.08 ± 0.38°C and 77.61 ± 0.46°C, respectively, using SYBR® Green I; 80.18 ± 0.27°C and 80.59 ± 0.08°C, respectively, using Radiant Green; and 82.19 ± 0.04°C and 82.62 ± 0.13°C, respectively, using the LCGreen® PLUS dye. The SLS2 primers demonstrated higher specificity and identified MS DNA at 0.05 ng/μL. In a duplex reaction, SLS2 and tetrahydrocannabinoic acid synthase gene primers detected and differentiated MS and Cannabis sativa (CS) by melt peaks at 82.63 ± 0.35°C and 85.58 ± 0.23°C, respectively, using LCGreen® PLUS.  相似文献   

11.
The exhibits obtained in wildlife offence cases quite often present a challenging situation for the forensic expert. The selection of proper approach for analysis is vital for a successful analysis. A generalised forensic analysis approach should proceed from the use of non-destructive techniques (morphological and microscopic examination) to partially destructive and finally destructive techniques (DNA analysis). The findings of non-destructive techniques may sometime be inconclusive but they definitely help in steering further forensic analysis in a proper direction. We describe a recent case where a very small dried skin piece (< 0.05 mg) with just one small trimmed guard hair (0.4 cm) on it was received for species identification. The single guard hair was examined microscopically to get an indication of the type of species. We also describe the extraction procedure with a lower amount of sample, using an automated extraction method (Qiagen Biorobot EZ1®) and PCR amplification of three mitochondrial genes (16s rRNA, 12s rRNA and cytochrome b) for species identification. Microscopic examination of the single hair indicated a viverrid species but the initial DNA analysis with 16s rRNA (through NCBI BLAST) showed the highest homology (93%) with a hyaenid species (Hyaena hyaena). However, further DNA analysis based on 12s rRNA and cytochrome b gene proved that the species was indeed a viverrid i.e. Viverricula indica (small Indian civet). The highest homology shown with a Hyaenid species by the 16s rRNA sequence from the case sample was due to lack of a 16s rRNA sequence for Viverricula indica in the NCBI data base. The case highlights the importance of morphological and microscopic examinations in wildlife offence cases. With respect to DNA extraction technology we found that automatic extraction method of Biorobot EZ1® (Qiagen) is quite useful with less amount of sample (much below recommended amount).  相似文献   

12.
Visualization of fingerprint deposits by digital color mapping of light reflected from the surface of heated brass, copper, aluminum, and tin has been investigated using Adobe® Photoshop®. Metals were heated to a range of temperatures (T) between 50°C and 500°C in 50°C intervals with enhancement being optimal when the metals are heated to 250°C, 350°C, 50°C, and 300°C, respectively, and the hue values adjusted to 247°, 245°, 5°, and 34°, respectively. Fingerprint visualization after color mapping was not degraded by subsequent washing of the metals and color mapping did not compromise the visibility of the fingerprint for all values of T. The optimum value of T for fingerprint visibility is significantly dependent of the standard reduction potential of the metal with Kendall's Tau (τ) = 0.953 (p < 0.001). For brass, this correlation is obtained when considering the standard reduction potential of zinc rather than copper.  相似文献   

13.
Blood spatter analysis is an important step for crime scene reconstruction. The presence of saliva in blood spatter could indicate expectorated blood which is difficult to distinguish from impact spatter. In this study, four saliva test methods (SALIgAE®, Phadebas® sheet, RSID-Saliva kit, and starch gel diffusion) were compared to identify the best method for detecting expectorated blood spatter. The RSID-Saliva kit showed the highest sensitivity even when saliva was mixed with blood, and was not inhibited by the presence of blood. The SALIgAE® test provided easy and rapid results, but the yellow color of a positive reaction was overwhelmed by the red color of the blood. The starch gel diffusion method and the Phadebas® sheet exhibited relatively low sensitivity and the assay took a long time. When using the RSID-Saliva kit for identifying saliva in blood, results should be read within 10 min.  相似文献   

14.
In forensic DNA casework, the interpretation of an evidentiary profile may be dependent upon the assumption on the number of individuals from whom the evidence arose. Three methods of inferring the number of contributors—NOCIt, maximum likelihood estimator, and maximum allele count, were evaluated using 100 test samples consisting of one to five contributors and 0.5–0.016 ng template DNA amplified with Identifiler® Plus and PowerPlex® 16 HS. Results indicate that NOCIt was the most accurate method of the three, requiring 0.07 ng template DNA from any one contributor to consistently estimate the true number of contributors. Additionally, NOCIt returned repeatable results for 91% of samples analyzed in quintuplicate, while 50 single‐source standards proved sufficient to calibrate the software. The data indicate that computational methods that employ a quantitative, probabilistic approach provide improved accuracy and additional pertinent information such as the uncertainty associated with the inferred number of contributors.  相似文献   

15.
A woman was found unresponsive with an empty bottle of Cogentin® prescribed to another. Admitted to an area hospital, her condition steadily declined until death 29 h after admission. Following toxicological screening on hospital (admission) whole blood, the only significant compound detected was benztropine. Benztropine was confirmed at 0.28 mg/L – the highest antemortem blood concentration recorded in a case of toxicity or fatality uniquely associated with benztropine. A second serum antemortem specimen showed a benztropine concentration of 0.19 mg/L. Despite over 24 h in the hospital, benztropine was also found in the postmortem specimens collected at autopsy. Peripheral blood, central blood, liver, and gastric concentrations were 0.47 mg/L, 0.36 mg/L, 9.6 mg/kg, and 44 mg, respectively. These results indicate that benztropine exhibited a potential difference between whole‐blood and serum (plasma) concentrations. Additionally, in consideration of literature data, benztropine was found indicative of a compound prone to at least some postmortem redistribution.  相似文献   

16.
The use of narrow‐banded visible light sources in improving the visibility of injuries has been hardly investigated, and studies examining the extent of this improvement are lacking. In this study, narrow‐banded beams of light within the visible light spectrum were used to explore their ability in improving the visibility of external injuries. The beams of light were induced by four crime‐lites® providing narrow‐banded beams of light between 400 and 550 nm. The visibility of the injuries was assessed through specific long‐pass filters supplied with the set of crime‐lites®. Forty‐three percent of the examined injuries improved in visibility by using the narrow‐banded visible light. In addition, injuries were visualized that were not visible or just barely visible to the naked eye. The improvements in visibility were particularly marked with the use of crime‐lites® “violet” and “blue” covering the spectrum between 400–430 and 430–470 nm. The simple noninvasive method showed a great potential contribution in injury examination.  相似文献   

17.
Recently, different portable hand-held and battery-powered dental X-ray units have become available. Especially for forensic odontological purposes, they offer diverse advantages such as for use in disaster areas and crime-scene locations as also in autopsy rooms and mortuaries. For any application, the most important feature of these hand-held devices is the delivered image quality. The aim of this study is to evaluate the radiographic image quality acquired by two portable X-ray devices in combination with two types of image receptors and to compare the findings with the image quality of a standard intra-oral X-ray device.Eleven samples consisting of eight teeth, two dry skeletal specimens and one formalin-fixed mandible part were mounted on blocks for standardised (re)positioning. Radiological images were acquired with two hand-held (AnyRay® 60 kVp, 0.02–4.00 mAs and NOMAD® 60 kVp, 0.023–2.277 mAs) and one wall-mounted (MinRay® 60/70 kVp 0.14–22.4 mAs) X-ray device combined with two image receptor systems (VistaScan® phosphor storage plate (PSP) and SIGMA® M CMOS Active Pixel technology sensor). The effect of X-ray source-to-object distance (SOD) was checked at 20 cm in conjunction with object to image receptor distances (OIDs) of 0.8 and 2.5 cm. For each parameter setup, the exposure times were run from low till high. An expert consent statement was achieved by agreement of four expert observers selecting the optimal images based on a developed four point quality rating system. Next, a selection of the images was assembled in a set of 198 observation screens and scored by seven observers. The observation screens were designed to compare observer scores, relations between devices, receptors and OIDs and images obtained from the different devices at equal exposure levels (mAs). All results were statistically analysed.Radiological image quality was significantly higher for phosphor plate compared with the CMOS digital receptor system (p < 0.0001). Furthermore, a significantly superior image quality was obtained for OID = 0.8 than for OID = 2.5 (p = 0.039). A significant difference in image quality between the three devices was also established (p = 0.02). The present study demonstrated the feasibility of portable X-ray systems for forensic odontological applications based on rendering optimal image quality, provided an in vitro guideline of optimal parameter settings and offered a radiological image database usable in further research.  相似文献   

18.
The processing of skeletal material poses several challenges for forensic laboratories. Current methods can be laborious, time-consuming, require dedicated equipment, and are vulnerable to contamination. In this study, various sample mass (1 × 50 mg, 3 × 50 mg, and 1 × 150 mg chip(s)) and incubation times (2, 4, and 16 h) were tested using the PrepFiler® BTA™ Forensic DNA Extraction Kit to digest whole bone chips in lieu of powdering. The most effective method was then applied to bones and tooth fragments collected from contemporary human cadavers exposed to various environmental conditions using an automated platform. Over a third of the samples tested generated full DNA profiles without having to powder the bone/tooth fragment or further alter the manufacturer's protocol. However, for most samples resulting in incomplete STR profiles due to low amounts of DNA, slightly better results were achieved with powdered tissue. Overall, this work demonstrates the potential use of a faster, nonpowdering DNA extraction method for processing skeletal samples as an effective first-pass screening tool.  相似文献   

19.
In order to increase the understanding regarding the oral abuse and potential toxicity of fentanyl patches seven cases were identified over a 3-year period where fentanyl, either alone or in combination with other factors, contributed to death following the oral abuse of Duragesic patches. The decedents comprised three females and four males with ages ranging from 20 to 51 years. Postmortem blood fentanyl concentrations were determined in all cases and ranged from 7 to 97 ng/mL. Two deaths were classified as a fentanyl overdose, three deaths were classified as a fentanyl and ethanol overdose, one death was considered a mixed drug intoxication and the remaining death was determined to be a combination of fentanyl and medical causes. These cases represent the largest reported series of deaths following the oral administration of transdermal fentanyl patches and provide detailed information on the potential for the abuse of transdermal Duragesic patches via this route. The postmortem blood fentanyl concentrations detected for each of the decedents demonstrate the potentially fatal blood concentrations that can arise after this relatively rare route of administration.  相似文献   

20.
Forensic evidence samples are routinely found as stains on various substrates, which may contain substances known to inhibit polymerase chain reaction (PCR). The goal of this study was to evaluate post‐Chelex®100 purification using powdered activated carbon (PAC). Mock crime scene DNA extracts were analyzed using quantitative PCR and short tandem repeat (STR) profiling to test the DNA recovery and inhibitor removal using PAC with those of the Amicon®Ultra 100K. For extracted bloodstains on soil and wood substrates, PAC and Amicon®Ultra 100K generated similar DNA yield and quality. Moreover, the two methods significantly decreased the concentration of humic substances and tannins compared to nonpurified extracts (< 0.001). In instances where extracts contained indigo dye (bloodstains on denim), Amicon®Ultra 100K performed better than PAC due to improved amplifiability. Efficient adsorption of humic substances and tannins, which are common inhibitors, indicates PAC's potential application in the purification of high‐template DNA extracts.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号