1.
A simple and rapid method for the extraction of four diazine herbicides (terbacil, bromacil, norflurazon and PAC) from human whole blood, plasma and urine with use of Bond Elut C18 cartridges is presented. Whole blood, plasma and urine samples containing the herbicides, after mixing with distilled water, were loaded on Bond Elut C18 cartridges and the herbicides were eluted with chloroform/methanol (9:1). They were detected by capillary gas chromatography with flame ionization detection (FID) with splitless injection. Separation of the four diazine herbicides from each other and from impurities was generally satisfactory with the use of an intermediately polar DB-17 capillary column. The recovery of all compounds, which had been added to whole blood, plasma and urine, was > 89%. The calibration curve for the herbicides, which has been added to whole blood, plasma and urine, showed linearity in the range 1.6–100 ng on column. Their detection limits were 1.2–1.4 ng on column for whole blood and plasma, and 1.1–1.2 ng on column for urine.  相似文献   

2.
A method has been developed for the rapid extraction of cocaine and benzoylecgonine from post-mortem blood and urine samples. Solid phase columns containing C8 packing material gave clean, emulsion free extracts from body fluids. The total time for each extraction was approx. 10 min and the system has the capacity for the simultaneous extraction of up to 10 samples. Urine can be extracted directly, blood samples were sonicated before extraction to allow for their easy passage through the columns. The method gave excellent recoveries of cocaine (98-100%) from spiked samples at concentrations of between 50 ng/ml and 10 micrograms/ml. Analysis of the extracts was by high performance liquid chromatography (HPLC).  相似文献   

3.
目的采用固相萃取-气相色谱法检测全血中佐匹克隆。方法采用Oasis HLB固相萃取柱对样品进行前处理,去离子水、0.5%氨水-甲醇/水((V/V 40∶60)溶液先后淋洗,二氯甲烷/异丙醇(V/V 75∶25)洗脱后进行GC/NPD检测。结果血液中佐匹克隆在50~5 000ng/mL范围内线性良好(R2=0.998 8),平均萃取回收率为96.9%,检出限为30ng/mL,日内RSD为2.1%~5.7%,日间RSD为3.3%~6.2%,结论固相萃取-气相色谱检测法灵敏度高,重现性好,可在血液中佐匹克隆的检测中选用。  相似文献   

4.
The use of the peroxidase-anti-peroxidase (PAP) technique has been described previously for the detection of cellular antigens and in particular ABO antigens from tissue samples (Pedal and Hülle 1984; Pedal and Baedeker 1985; Pedal et al. 1985). In this survey, the PAP method has been employed to study the detection of ABO antigens in cells from body fluids of particular interest to forensic science, namely buccal cells and vaginal cells. Also tested, but in a limited number, were mixtures of body fluids and semen samples. No false reactions were obtained from buccal cells, all samples corresponding to the ABO blood type of the donor. Preliminary results from vaginal cells, vaginal/buccal cell mixtures, and semen were encouraging but must be treated with caution due to the limited number tested. Vaginal smears contaminated with semen showed varying degrees of nonspecificity.  相似文献   

5.
6.
Immunoaffinity extraction units (LSD ImmunElute) are commercially available for the analysis of lysergic acid diethylamide (LSD) in urine. The ImmunElute resin contains immobilized monoclonal antibodies to LSD. We applied the ImmunElute procedure to serum and also to human hair samples. For hair analysis the samples were first extracted with methanol under sonication. The extracts were then purified using the ImmunElute resin. LSD analysis was carried out with HPLC and fluorescence detection. The immunoaffinity extraction provides highly purified extracts for chromatographic analysis. The limit of detection (signal-to-noise ratio = 3) has been determined to be < 50 pg regardless of which sample material was used. The procedure was applied to authentic hair samples from drug abusers (n = 11). One of these samples tested positive with an amount of 110 pg LSD in 112 mg extracted hair corresponding to a concentration of 1 pg/mg.  相似文献   

7.
8.
This preliminary study compares the benzodiazepine results for 10 post-mortem scalp hair samples using a classical solid-phase extraction (SPE) and a molecularly imprinted solid-phase extraction (MISPE) system. The hair samples selected for testing were from drug-related deaths where a positive benzodiazepine blood result was obtained. Samples were decontaminated with 0.1% sodium dodecyl sulfate, distilled water and dichloromethane, incubated overnight in methanol/25% aqueous ammonium hydroxide (20:1), extracted by SPE or MISPE and subsequently analysed by liquid chromatography-tandem mass spectrometry (LC-MS-MS). Both extraction methods detected diazepam, nordiazepam, oxazepam, temazepam and nitrazepam in the samples. Diazepam was detected in a greater number of samples using MISPE due to both its lower limit of detection (LOD) and higher extraction recovery as a result of excellent molecular recognition of the template (diazepam) imparted by the imprinting process. The selective recognition of two diazepam analogues, nordiazepam and oxazepam, was demonstrated using MISPE since they were also detected in a greater number of samples. In contrast, another diazepam analogue, temazepam, was detected in a greater number of samples using SPE since the LOD using this extraction was lower than with MISPE. Nitrazepam was detected in one sample using both extraction methods. Overall the MISPE and SPE hair results were in good qualitative agreement. For the samples, where both extraction methods detected nordiazepam, temazepam and oxazepam, the concentrations were always higher for SPE. This is probably due to the MIP procedure producing extracts with fewer matrix interferences than the extracts produced using the classical SPE method. MISPE could be used as a complementary method to classical SPE for the analysis of benzodiazepine positive hair samples collected from chronic users.  相似文献   

9.
Active compounds of some mushrooms e.g. Psilocybe cubensis, Paneolus subalteatus or Stropharia coronilla, the psychotropic agents psilocybin and psilocin, have hallucinogenic effects. In one case of 'magic mushroom' intake, we had to analyse blood and urine. Psilocin was detected in the urine with REMEDi HS. Most of the psilocin was excreted as the glucuronide. Therefore an enzymatic hydrolysis should be the first step in analysis. Free psilocin was determined at a concentration of 0.23 mg/l while the total amount was 1.76 mg/l urine. The concentration of psilocin in serum was too low for detection with REMEDi HS. We proved a GC-MS-method with d(3)-morphine as internal standard and silylation with MSTFA. Similarly to urine, most of the psilocin in serum was found in the conjugated form. The concentration of free psilocin was 0.018 mg/l, that of total psilocin, 0.052 mg/l serum.  相似文献   

10.
This article describes a fully automated procedure for detecting cannabinoids in human hair samples. The procedure uses alkaline hydrolysis and headspace solid-phase dynamic extraction (HS-SPDE), followed by on-coating derivatization and gas chromatography-mass spectrometry (GC-MS). SPDE is a further development of solid-phase microextraction (SPME), based on an inside needle capillary absorption trap. It uses a hollow needle with an internal coating of polydimethylsiloxane as extraction and pre-concentration medium.Ten mg of hair were washed with deionised water, petroleum ether and dichloromethane. After adding deuterated internal standards, the sample was hydrolyzed with sodium hydroxide and directly submitted to HS-SPDE. After absorption of analytes for an on-coating derivatization procedure, the SPDE-needle was directly placed into the headspace of a second vial containing N-methyl-N-trimethylsilyl-trifluoroacetamide before GC-MS analysis. The limit of detection was 0.14 ng/mg for Delta(9)-tetrahydrocannabinol, 0.09 ng/mg for cannabidiol, and 0.12ng/mg for cannabinol. Absolute recoveries were in the range of 0.6 to 8.4%. Linearity was verified over a range from 0.2 to 20 ng/mg, with coefficients of correlation between 0.998 and 0.999. Intra- and inter-day precision were determined at two different concentrations and resulted in ranges between 2.3 and 6.0% (intra-day) and 3.3 and 7.6% (inter-day). Compared with conventional methods of hair analysis, this automated HS-SPDE-GC-MS procedure is substantially faster. It is easy to perform without using solvents and with minimal sample quantities, and it yields the same sensitivity and reproducibility. Compared to SPME, we found a higher extraction rate, coupled with a faster automated operation and greater stability of the device.  相似文献   

11.
12.
A new solid-phase extraction procedure for the determination of cocaine and benzoylecgonine in amniotic fluid, using high flow co-polymeric sorbents is reported. The recoveries of cocaine and benzoylecgonine within the range 0.1-1 mg/l were 95.7% and 50.3%, respectively. The use of high-flow sorbents allowed the easy extraction of amniotic fluid regardless of sample viscosity or physical nature. The use of these solid-phase columns provided many advantages over the more commonly used solvent extraction, including an increase in extraction speed and efficiency, reduced operator time, reduced solvent use and disposal volumes and exceptional extract quality. Further, the determination of amniotic fluid obtained from pregnant cocaine users may provide important information about handling of cocaine by the fetus at various gestational ages. The procedure was successfully applied to amniotic fluid from suspected cocaine abusers.  相似文献   

13.
目的建立分子印迹固相萃取(MISPE)、GC/MS分析方法,用于血液中苯丙胺类毒品检测。方法 10mmol/L醋酸铵缓冲液(pH8.0)4倍稀释空白添加血液,1mL甲醇,1mL10mmol/L醋酸铵缓冲液(pH8.0)活化苯丙胺类分子印迹固相萃取柱;2×1mL去离子水、1mL60%的乙腈去离子水、1mL1%醋酸乙腈洗涤杂质;2×1mL1%甲酸/甲醇洗脱,洗脱液挥干定容,经GC/NPD、GC/MS分析检测。结果各种苯丙胺类毒品回收率均在90%以上,在20~5 000ng/mL浓度范围内线性关系良好,r2为0.995 7~0.998 9,LOQ在16~30ng/mL之间,LOD在8~15ng/mL之间。结论本方法回收率高,净化效果显著,稳定性好,杂质干扰少,可用于血液中低浓度苯丙胺类毒品的分析检测。  相似文献   

14.
Six cases of suspected poisoning were studied. The various body tissues and fluids of all the cases were analysed and malathion was found positive. The quantitative analysis was performed using high performance liquid chromatography. The distribution of malathion was studied in lungs, liver, kidneys, spleen, brain, heart, blood, muscles, urine and gastric contents.  相似文献   

15.
A method to use ionizing radiation to inactivate HIV (Human Immunodeficiency Virus) in human body fluids was studied in an effort to reduce the risk of accidental infection to forensic science laboratory workers. Experiments conducted indicate that an X-ray absorbed dose of 25 krad was required to completely inactivate HIV. This does not alter forensically important constituents such as enzymes and proteins in body fluids. This method of inactivation of HIV cannot be used on body fluids which will be subjected to deoxyribonucleic acid (DNA) typing.  相似文献   

16.
A 54 year-old female expired at her residence. Her husband, a physician, signed a certificate stating that her death was due to cerebrovascular accident (CVA) and released her body to a funeral home, where she was embalmed. Since the deceased had a long history of medical problems and drug abuse, an autopsy was performed and no evidence of CVA was found. Toxicological analyses of body fluids and tissues revealed the presence of ethchlorvynol in high concentration in the bile (112 mg/l). The bloody fluid collected from the heart contained a concentration of ethchlorvynol below the limit for quantitation. Other findings included phenobarbital (32.8 mg/l) in heart bloody fluid and methanol (an ingredient of embalming fluid). The significance of the findings is discussed in relation to embalmment prior to autopsy and toxicological analyses. Ethchlorvynol concentration in the bile is compared to other fatal cases due to ethchlorvynol overdose.  相似文献   

17.
《Science & justice》2023,63(4):493-499
Forensic scientists are often asked to assist the court by evaluating the significance of finding body fluids on the hands of an individual; however, there is an absence of published data regarding the background levels of body fluids on hands. Whilst the scientist can use casework experience to inform the courts on the significance of the results, it would be advantageous to have data which could assist with this interpretation. This study was designed to ascertain the background levels of blood, semen, saliva, hairs/fibres and staining/debris on hands in the general population by sampling from delegates attending a scientific conference.The findings suggest that approximately one third of the population would be expected to have hairs or fibres on their hands and that females are more likely to have visible staining on their hands than males. Presumptive tests for blood and semen yielded negative results in all samples; however, almost 2 % of the samples were found to contain a very low number of sperm heads. In contrast, the majority of samples tested positive for the presence of saliva using the presumptive Phadebas® amylase test. The data supports the caution applied by forensic practitioners when evaluating the presence of saliva detected using the presumptive Phadebas® amylase test based on the lack of specificity and indicates that the RSID™-Saliva test would be more suitable to use.  相似文献   

18.
Two cases of fatal overdose with morphine are presented. Large amounts of the drug were involved in both cases, one by oral ingestion, the other by intravenous injection. Morphine concentrations in various body fluids and tissues are compared to those in the literature.  相似文献   

19.
Meng PJ  Wang JH  Jiang ZL  Yao LJ  Wang YJ 《法医学杂志》1999,15(1):17-8, 63
A solid-phase extraction method of morphine from urine and blood has introduced. The effect of 5 SPE columns, 3 eluents and pH on morphine recovery has been investigated systematically. Derivative GC was used as a method of detection. The result showed that the column and the eluent of such as GDX-301, GDX-403 and C18 chloroform:isopropanol (9:1) had good behaviors to extraction of morphine. When GDX-301 was used as a sorbent, the recovery of morphine from urine was above 90% at pH 9, then went down with the increase of pH. While the recovery from blood was growing with the increase of pH, which reached above 90% in strong alkaline. The extraction method is simple, inexpensive, efficient and reproducible, which provides an effective and practical method to extract morphine and similar illicit drugs from biological fluids.  相似文献   

20.
Raman spectroscopy was used to compare body fluids commonly found at crime scenes in a nondestructive manner. The dry traces of semen, vaginal fluid, sweat, saliva, and blood were analyzed using confocal Raman microscopy with a 785-nm excitation. The results show that the five fluids can be differentiated from one another by visual comparison of their Raman spectra, and that the laser radiation does not damage the sample. The Raman signature of each body fluid is specific and correlates with the known composition of the fluid. Dry traces of human and canine semen exhibited distinctly different Raman signatures. Overall, this preliminary study demonstrates the great potential of Raman spectroscopy for nondestructive, confirmatory identification of body fluids for forensic purposes.  相似文献   