首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到5条相似文献,搜索用时 0 毫秒
1.
The purpose of this study was to evaluate the potential of inorganic analysis techniques for the discrimination of document (multipurpose office) paper. A set of 25 different multipurpose office papers from the European market was used for comparison. It appeared that for the single techniques LA–ICP–MS had the highest overall discriminating power. Despite its lower sensitivity, XRF also showed good discriminating power but the correlation with LA–ICP–MS is high. The combination of LA–ICP–MS and IRMS provides a powerful and strongly discriminating set of techniques.  相似文献   

2.
This work presents the validation of a new immunological assay, the One-Step™ enzyme-linked immunosorbent assay (ELISA) tests from International Diagnostic Systems Corp. for the screening of drugs of abuse (cannabis, amphetamines, opiates, and cocaine) in human hair, with subsequent GC–MS confirmation. After decontamination and segmentation into small pieces, 50 mg of hair sample were incubated in 1 ml of methanol during 16 h at 40 °C. A 100 μL aliquot was collected and evaporated to dryness in presence of 100 μL of methanol/hydrochloric acid (99:1, v/v) to avoid amphetamines loss. The dried extract was dissolved in 100 μL of the “sample and standard diluent” solution included in the kit. This solution was submitted to analysis according to the recommended instructions of the manufacturer. During the validation phase, GC–MS confirmations were conducted according to our fully validated and published methods for opiates, cocaine, cannabis, and amphetamines determinations in hair. In a last development step, these procedures were slightly modified to directly confirm ELISA results by GC–MS using the methanolic extract. Ninety-three specimens were simultaneously screened by the ELISA tests (103 for tetrahydrocannabinol (THC)) and confirmed by GC–MS. Twenty were found positive for cannabis (THC: 0.10–6.50 ng/mg), 21 for cocaine (0.50–55.20 ng/mg), 24 for opiates (6-acetylmorphine (6-AM): 0.20–11.60 ng/mg, MOR: 0.20–8.90 ng/mg, codeine (COD): 0.20–5.90 ng/mg), and 13 for amphetamines (AP: 0.20 and 0.27 ng/mg, methamphetamine (MAP): 0.30 and 1.10 ng/mg, methylenedioxymethamphetamine (MDMA): 0.22–17.80 ng/mg). No false negative results were observed according to the Society of Hair Testing's (SoHT) cutoffs (0.5 ng/mg for cocaine, 0.2 ng/mg for opiates and amphetamines, and 0.1 ng/mg for THC). The One-Step™ ELISA kits appear suitable due to their sensitivity and specificity for drug of abuse screening in hair. This technology should find interest in workplace drug testing or driving license regranting, especially when many samples have to be tested with a high rate of negative samples, as ELISA is an easy and high-throughput method.  相似文献   

3.
《Science & justice》2022,62(5):494-505
The overlay method is used in forensic podiatry to compare the shape, position, and overall fit of features between questioned and reference footprint evidence. However, the scientific foundation underpinning its validity in the comparison of insole footprints is not fully understood because of a lack of published data defining its statistical operating parameters. A review of literature revealed its subjective nature with little scientific validation, limited only to face validity.The aim of this study investigated strength of agreement between three expert footprint examiners’ overlay comparisons of ten reference insole footprints using Cohen’s weighted kappa (Kw). Validity of method was explored using measures of sensitivity, specificity, false positive rate (FPR), false negative rate (FNR), receiver operating characteristic (ROC) curve and area under the ROC curve (AUC). Results showed two examiners demonstrated high inter-rater consistency between their overlay comparisons (Kw: 0.981; 95 %CI: 0.943 to 1.020 for Rater1 v Rater2) whilst one examiner did not (Kw: 0.340; 95 %CI: 0.148 to 0.532 for Rater1 v Rater3; Kw: 0.310; 95 %CI: 0.100 to 0.519 for Rater2 v Rater3). Validity was investigated using a conclusion scale in a verbal expressions table to indicate support or rejection of compatibility of footprints between one questioned insole and ten reference insoles. Data analysis indicated validity as follows: Sensitivity: 77.8 %, Specificity: 61.9 %, FPR: 38.1 % and FNR: 22.2 %. ROC analysis corroborated this finding. AUC was calculated at 0.762 or 76.2 % indicating an ‘acceptable’ measure of overall accuracy of the overlay method for insole footprint comparison. Findings provide novel data supporting previous suggestions that the overlay method should not be used in isolation to compare insole footprints. Data also offers insight into the scientific foundation of this method, whilst highlighting its limitations and providing some implications and recommendations for forensic podiatry practice.  相似文献   

4.
We present the results of an initial investigation into the efficacy of using testate amoebae for the discrimination of soils from wet ground and puddles, as little attention has been given to these organisms in forensic science. The preservation of testate amoebae in these sediments is generally good, although test concentrations are low. Statistical analysis suggests that testate amoebae assemblages are somewhat spatially distinct and have potential to be used for soil discrimination. A case study is presented where mineralogical (X-ray diffraction) and testate amoebae analyses are used in conjunction to clarify the scene of crime in a ‘cold case’ murder enquiry. Testate amoebae were recovered from dried sediment residues on clothing 10 years after the murder. Despite these promising results, further experimental work is crucial to examine the spatial and temporal variation of amoebae assemblages in water films, wet ground and puddles before they can be added to the armoury of methods available to the forensic biologist.  相似文献   

5.
FTIR spectroscopy has been found to be a valuable probe for the analysis of the distribution of organic components such as nitroglycerine in gunshot residues deposited on and around the bullet entrance hole of the clothing of the victim in short range firearm discharges. The method can be utilised for the detection and estimation of organic gunshot residues (OGSR) on the hands and clothing of the shooter. The method is specific and sensitive and is likely to be free from interference from, for example, environmental pollution. The method shows potential to be utilised as a suitable alternative to the widely used SEM-EDX analysis of the total contents of lead, barium and antimony present in the gunshot deposits around the bullet entrance hole. The method was tested in the laboratory and the results were validated by Gas Chromatography-Mass Spectrometry (GC-MS).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号