首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Oral fluid is an interesting alternative matrix for drug testing in many environments, including law enforcement, workplace drug testing, and drug treatment facilities. Performance characteristics of the FDA-cleared, qualitative, Cozart RapiScan Opiate Oral Fluid Drug Testing System (Opiate Cozart RapiScan System or Opiate CRS) were compared to the semi-quantitative Cozart Microplate EIA Opiate Oral Fluid Kit (Opiate ELISA) and to gas chromatography/mass spectrometry (GC/MS). The following oral fluid opiate cutoffs were evaluated: the GC/MS limit of quantification (LOQ) of 2.5 mg/l; 15 microg/l currently used for oral fluid testing in the United Kingdom (UK); 30 microg/l (Opiate CRS cutoff); and 40 microg/l, the proposed Substance Abuse and Mental Health Services Administration (SAMHSA) cutoff. Subjects provided informed consent to participate in this IRB-approved research and resided on the closed research ward throughout the study. Three oral codeine doses of 60 mg/70 kg were administered over a 7-day period. After a 3-week break, subjects received three doses of 120 mg/70 kg within 7 days. Oral fluid specimens (N = 1273) were analyzed for codeine (COD), norcodeine (NCOD), morphine (MOR) and normorphine (NMOR) by GC/MS with an LOQ of 2.5 microg/l for all analytes. MOR and NMOR were not detected in any sample; 26.5% of the specimens were positive for COD and 13.7% for NCOD. Opiate CRS uses a preset, qualitative cutoff of 10 microg/l; this is equivalent to 30 microg/l in undiluted oral fluid as the oral fluid collection process involves a 1:3 dilution with buffer. Sensitivity, specificity, and efficiency of Opiate CRS compared to Opiate ELISA were 98.6, 98.1, and 98.2% at a 30 microg/l cutoff and 99.0, 96.2, and 96.6% at a 40 microg/l cutoff. Compared to the much lower GC/MS LOQ of 2.5 microg/l, sensitivity, specificity and efficiency were 66.8, 99.3 and 90.7%. Increasing the GC/MS cutoff to the current UK level yielded performance characteristics of 81.5% (sensitivity), 99.3% (specificity), and 95.4% (efficiency). Using a GC/MS cutoff identical to the preset Opiate CRS cutoff yielded sensitivity, specificity, and efficiency of 88.5, 99.2, and 97.5%, respectively. At the proposed SAMSHA confirmation cutoff of 40 microg/l, sensitivity increased with little change in specificity and efficiency (91.3% sensitivity, 98.9% specificity, and 97.5% efficiency). Oral fluid is a suitable matrix for detecting drugs of abuse. Opiate CRS, with a 30 microg/l cutoff, is sufficiently sensitive, specific and efficient for oral fluid opiate analysis, performing similarly to Opiate ELISA at the same cutoff, and having performance characteristics >91% when compared to GC/MS at the proposed SAMHSA cutoff.  相似文献   

2.
唾液中乙醇含量检测试剂条的研究   总被引:1,自引:0,他引:1  
目的根据唾液和血液中乙醇含量相关性的实验结果,建立了一种简便快速、准确可靠的检测唾液中乙醇含量的方法。方法本方法利用酶学原理,将一定量乙醇氧化酶(ALO)和过氧化物酶以及底物四甲基联苯胺(TMB)固定于试剂条上,当样本中含有乙醇时,酶学反应使底物TMB显色,通过比对反应的不同颜色,对样本中乙醇质量浓度进行半定量。结果用本方法检测300个自愿者的唾液,和用GC/MS法对照检测志愿者唾液中的乙醇含量,定量结果基本一致。本产品检测过程仅需2min,其检测的阈值为0.1mg/mL,敏感度为96.5%,特异性为91%,准确性为94.7%。结论采用酶学方法制备的乙醇含量检测试剂条,通过显色反应对唾液中的乙醇含量进行半定量检测,其特点为快速简便、准确可靠,适合现场使用。  相似文献   

3.
The RSID-saliva test and the SALIgAE-saliva test are two recently developed forensic saliva detection kits. In this study, we compared the sensitivity and the specificity of the two test kits with the Phadebas amylase test by analyzing amylases from various sources including human, animals, plants, and micro-organism. The data demonstrate that the RSID-saliva test and the SALIgAE-saliva test offer higher sensitivity and specificity for the detection of saliva than the Phadebas amylase test. The detection limits of the RSID-saliva test, the SALIgAE-saliva test, and the Phadebas amylase test equate to 10, 4, and 1000 nL, respectively for human saliva. The RSID-saliva test and the SALIgAE-saliva test were further evaluated by analyzing semen, vaginal secretion, breast milk, blood, urine, sweat, and feces. The results of the two tests are in good agreement. The two tests reacted with urine, breast milk, and feces, but not with semen, vaginal secretion, blood, and sweat.  相似文献   

4.
The objective of this study was to develop a two-step strategy for analysis of opiates and cocaine in hair samples involving an immunological screening procedure followed by confirmation of results using gas chromatography-mass spectrometry (GC-MS). A semi-quantitative automated competitive enzyme-linked immunosorbent assay (ELISA) methodology using Oral Fluid Micro-Plate Enzyme Immunoassays (Orasure Technologies, Inc.) was developed and validated. Applicability was proven by analysis of authentic head hair samples from drug users (n=103) and from opiate associated fatalities (n=21). The optimum cutoff values for the ELISA tests were 0.1 ng cocaine-equivalents/mg hair and 0.05 ng morphine-equivalents/mg hair using a 50 mg hair sample. Both ELISA tests had a sensitivity of 100%, the specificity was 66% for cocaine-equivalents and 42% for morphine-equivalents. The intraassay precision was 11% for the cocaine and 3% for the opiates ELISA, while interassay precision was 12% for the cocaine and 4% for the opiates ELISA test. The actual analyte concentrations in the hair samples were determined using GC-MS and were between 0.04 and 5.20 ng/mg for heroin (HER), between 0.04 and 30.01 ng/mg for 6-monoacetylmorphine (MAM), between 0.03 and 11.87 ng/mg for morphine (MOR), between 0.02 and 1.84 ng/mg for codeine (COD), between 0.02 and 2.48 ng/mg for acetylcodeine (AC), between 0.01 and 21.37 ng/mg for cocaine (COC), between 0.03 and 10.51 ng/mg for benzoylecgonine (BE) and between 0.05 and 1.26 ng/mg for cocaethylene (CE). The automated ELISA tests were proven to be valid screening procedures for the detection of cocaine and opiates in hair as confirmed by GC-MS. Screening methods provide rapid and inexpensive automated pre-test procedures to detect drugs in hair or other matrices. For forensic purposes screening therefore represents an ideal complement to routinely applied GC-MS procedures.  相似文献   

5.
Development and Validation of the Validity Indicator Profile   总被引:1,自引:0,他引:1  
The Validity Indicator Profile (VIP; Frederick, 1997) is a two-alternative forced choice (2AFC) procedure intended to identify when the results of cognitive and neuropsychological testing may be invalid because of malingering or other problematic response styles. The test consists of 100 problems that assess nonverbal abstraction capacity and 78 word-definition problems. The VIP attempts to establish whether an individual's performance in an assessment battery should be considered representative of his or her true overall capacities (valid or invalid). Performances classified as valid are classified as compliant and reflect a high effort to respond correctly. Performances classified as invalid are subclassified as careless (low effort to respond correctly), irrelevant (low effort to respond incorrectly), or malingering (high effort to respond incorrectly). The VIP development sample included 944 nonclinical participants and 104 adults undergoing neuropsychological evaluation. The cross-validation sample consisted of 152 nonclinical participants, 61 brain-injured adults, 49 individuals considered to be at risk for malingering, and 100 randomly generated VIP protocols. The nonverbal subtest of the VIP demonstrated an overall classification rate of 79.8%, with 73.5% sensitivity and 85.7% specificity. The verbal subtest of the VIP demonstrated an overall classification rate of 75.5%, with 67.3% sensitivity and 83.1% specificity.Ross Crosby was at NCS Assessments, Minnetonka, Minnesota, during much of this project  相似文献   

6.
Zhou XR  Fan LH  Yang XP 《法医学杂志》2011,27(6):413-6, 420
目的 建立本实验室用动态姿势图识别非器质性或伪装平衡功能障碍的客观方法.方法 对104例正常受试者行动态姿势图检查后指导其伪装平衡功能障碍再进行动态姿势图检查,将伪装前后的平衡分进行配对t检验;应用以往研究提示伪装的7条标准对本实验的50例伪装前后的姿势图表现(包括原始曲线)进行判别,按照90%的敏感性选取并建立本实验...  相似文献   

7.
Saliva stains present a unique challenge in the forensic setting, often challenging the analyst to weigh the value of presumptive indication of the fluid versus the potential for DNA analysis to yield identification information. There are many situations in which determining the presence of a body fluid is probative and further corroborates DNA evidence. That said, even a minute portion of sample consumed by a screening test could mean the difference between a full, partial, or null profile obtained through DNA analysis. The basis of presumptive testing or screening of saliva has historically been based on the presence of amylase, a component found in relatively high concentrations in human saliva versus other body fluids and substances. Though the current available methods for the screening of saliva in a forensic application have grown in number, the popularity of these methods seemingly has not. This study attempts to identify a specific and sensitive saliva screening test by comparing three modern techniques--the recently released SALIgAE, Phadebas, and starch-iodine mini-centrifuge test--on the basis of sensitivity, specificity, mixtures, and simulated casework samples while also considering sample consumption. The Phadebas method for presumptive saliva testing detected dilutions of neat saliva down to 1:200 versus considerably less sensitive results with SALIgAE and the starch-iodine mini-centrifuge test. Utilizing a screening test with a high degree of sensitivity, such as Phadebas, allows an analyst to gain a maximum amount of information in the form of body fluid indication and DNA results because of the consumption of a small portion of sample.  相似文献   

8.
The detection of saliva in forensic casework is extremely important in many types of cases. This study describes a relatively sensitive method, based on a red dye bound to starch, for the detection of amylase. The sensitivity and specificity of the method has been examined by testing over 50 household products, various body fluids and five laboratory chemicals. This study demonstrated for the first time that positive results can be obtained from certain washing powders as well as other household products. As well as detecting amylase in saliva, positive Red-Starch results were obtained from faeces and urine. The method was found to be suitable for the detection of mixtures of saliva and semen in conjunction with the Brentamine test for the detection of acid phosphatase.  相似文献   

9.
Saliva or "oral fluid" has been presented as an alternative matrix to document drug use. The non-invasive collection of a saliva sample, which is relatively easy to perform and can be achieved under close supervision, is one of the most important benefits in a driving under the influence situation. Moreover, the presence of Delta9-tetrahydrocannabinol (THC) in oral fluid is a better indication of recent use than when 11-nor-Delta9-tetrahydrocannabinol-9-carboxylic acid (THC-COOH) is detected in urine, so there is a higher probability that the subject is experiencing pharmacological effects at the time of sampling. In the first part of the study, 27 drug addicts were tested for the presence of THC using the OraLine IV s.a.t. device to establish the potential of this new on-site DOA detection technique. In parallel, oral fluid was collected with the Intercept DOA Oral Specimen Collection device and tested for THC by gas chromatography mass spectrometry (GC/MS) after methylation for THC (limit of quantification: 1 ng/mL). The OraLine device correctly identified nine saliva specimens positive for cannabis with THC concentrations ranging from 3 to 265 ng/mL, but remained negative in four other samples where low THC concentrations were detected by GC/MS (1-13 ng/mL). One false positive was noted. Secondly, two male subjects were screened in saliva using the OraLine and Intercept devices after consumption of a single cannabis cigarette containing 25mg of THC. Saliva was first tested with the OraLine device and then collected with the Intercept device for GC/MS confirmation. In one subject, the OraLine on-site test was positive for THC for 2 h following drug intake with THC concentrations decreasing from 196 to 16 ng/mL, while the test remained positive for 1.5 h for the second subject (THC concentrations ranging from 199 to 11 ng/mL). These preliminary results obtained with the OraLine IV s.a.t. device indicate more encouraging data for the detection of THC using on-site tests than previous evaluations.  相似文献   

10.
11.
The Word Memory Test (WMT) is claimed to measure effort and to detect cognitive response bias. Archival data from n = 2526 cases referred in 2009–2016 for medicolegal assessment were analyzed. Each participant underwent a medical and a psychological examination including a cognitive test battery and several validity measures including the WMT. The WMT validity test scores do not approximately follow a normal distribution. Thus, parametric statistics for WMT validity scores may not be appropriate. WMT performance explains 0–20% of the variance in cognitive test performance. This is more than what substantial brain damage accounts for. The standard uniform cutoff indicating a ‘fail’ in all three WMT effort subtests (equal or less than 82.5% correct responses) seems not supported by the data. Taking into account the context of the testing, cutoffs may be chosen according to the desired sensitivity or specificity. ROC-statistics with modified Slick criteria as gold standard for malingering look alike for the three WMT effort subtests, with a AUC between 0.86 and 0.88. The WMT seems a good indicator of both effort and (Slick) malingering, however, little is gained by administering the entire test.  相似文献   

12.
The stability of salivary α‐amylase is a critical factor in both catalytic and immunological method‐based forensic saliva identification. This study aimed to assess the sensitivity of catalytic and immunological tests on degraded saliva samples. Degraded saliva stains were prepared by microbial decomposition using humid soil. Salivary α‐amylase activity was catalytically detected both qualitatively and quantitatively using the Phadebas® amylase test. As immunological methods, we conducted qualitative and quantitative tests using the RSID?‐saliva test and ELISA, respectively. Salivary α‐amylase activity of degraded samples (incubated at 37°C for 12 h) was significantly lower than that of controls in the quantitative tests. All the degraded samples obtained by the humid soil produced negative results in the Phadebas® tests, but showed positive results in the RSID?‐saliva test and ELISA. These results suggest that immunological tests are effective for testing degraded saliva samples that have lost their enzymatic activity.  相似文献   

13.
The sensitivity of a simple radioimmunoassay (RIA) for the detection of 19-OH prostaglandin F1 alpha/F2 alpha (PG F) has been evaluated on a number of semen samples from vasectomized, infertile and fertile donors. The specificity of the test has been examined by testing saliva, sweat and urine from a number of male and female donors. The assay technique could readily detect the PG in semen stains prepared from 0.2 microliter of semen from normal, infertile and vasectomized donors. The detection limit of the assay system, based on the observed displacement, was calculated to be approximately 0.05 microliter semen. The assay could be conducted over a pH range of 7.5-10.5 even after the PG has been heated to 100 degrees C. The 19-OH series of PG were absent from sweat, saliva and female urine using the normal assay protocol; volumes in excess of 100 microliters of some urines particularly from women in labour and those with acute urinary tract infection showed some displacement. Low levels of PG were detected in 50% of the male urine analysed. However, urine samples from men who had engaged in recent sexual activity contained relatively high concentrations of PG which could be readily detected in 10 microliters of urine. These results emphasise the potential of these compounds as specific and sensitive markers for the presence of human semen.  相似文献   

14.
15.

Aim

This study determined the extent to which alcohol and marijuana use during adolescence mediates the relation between transmissible risk for substance use disorder (SUD) and lifetime number of different types of violent offenses.

Methods

The transmissible liability index was administered to 359 10-12 year old youths who were tracked to 22 years of age. Past year frequency of alcohol and marijuana consumption was longitudinally tracked to age 22 at which time lifetime violent offenses was recorded.

Results

Rate of increase in marijuana use mediated the association between transmissible risk and lifetime number of different types of violent offenses. No association was found between past year frequency of alcohol use and violent offenses.

Conclusions

Prevention directed at lowering the psychological characteristics associated with transmissible risk for SUD may also reduce violent offending.  相似文献   

16.
Alcohol screening with the Alcoscan test strip in forensic praxis   总被引:1,自引:0,他引:1  
The Alcoscan test strip was applied as an assay for the screening of alcohol in vitreous humor and urine samples in autopsy cases and in saliva from drunken drivers. The method gives instant and reliable semi-quantitative information on the presence of alcohol and is valuable when considering the necessity of chemical sampling especially during autopsy.  相似文献   

17.
The breath analyzer is an indispensable tool for identifying alcohol levels among drivers. While numerous studies have shown high correlations between blood and breath alcohol concentrations, most are limited by the study design. This study seeks to assess this relationship by minimizing potential measurement bias, document time from alcohol consumption to testing, and adjusting for potential confounders. A blinded study was performed using conditions closely resembling those in the field. The Draeger 7110 MKIII IL breath analyzer was used to assess breath alcohol concentrations (BrAC). Participants were 61 healthy volunteers aged 21–37 years with body mass index ≤30 and no history of alcoholism. A total of 242 valid blood/breath tests were performed in four test sets. The study results showed a high correlation coefficient between BrAC and blood alcohol concentration (BAC) levels (r = 0.983) with high sensitivity (97%) and specificity (93%). This strong association between the breath analyzer and BAC persisted even after adjustment for various stages of alcohol absorption. These results illustrate the high diagnostic sensitivity of the breath analyzer in field‐tested conditions.  相似文献   

18.
The disposition in mice of the cannabimimetics JWH-018 and JWH-073 in blood and brain following inhalation of the smoke from the herbal incense product (HIP) "Magic Gold" containing 3.6% JWH-018, 5.7% JWH-073 and less than 0.1% JWH-398 (w/w) is presented. Specimens were analyzed by HPLC/MS/MS. The validation of the method is also presented. Five C57BL6 mice were sacrificed 20 min after exposure to the smoke of 200 mg of "Magic Gold" and a second set of five exposed mice were sacrificed after 20 h. Twenty minutes after exposure to "Magic Gold" smoke, blood concentrations of JWH-018 ranged from 42 to 160 ng/mL (mean: 88 ng/mL ± 42) and those of JWH-073 ranged from 67 to 244 ng/mL (mean: 134 ng/mL ± 62). Brain concentrations 20 min after exposure to "Magic Gold" smoke for JWH-018 ranged from 225 to 453 ng/g (mean: 317 ng/g ± 81) and those of JWH-073 ranged from 412 to 873 ng/g (mean: 584 ng/g ± 163). Twenty hours after exposure to "Magic Gold" smoke, JWH-018 was detected and quantified in only two of the five blood samples. Blood concentrations of JWH-018 were 3.4 ng/mL and 9.4 ng/mL. JWH-073 was detected in only one blood specimen 20 h after exposure at 4.3 ng/mL. Brain concentrations 20 h post exposure for JWH-018 ranged from 7 to 32 ng/g (mean: 19 ng/g ± 9). JWH-073 was not detected in 20 h post exposure brain specimens. JWH-398 was not detected in any of the blood or brain samples. The disposition data presented with the limited data available from human experience provide reasonable expectations for forensic toxicologists in JWH-018 or JWH-073 cases. As with THC after smoking marijuana, blood and brain concentrations of JWH-018 and JWH-073 after HIP smoking can be expected to rise initially to readily detected values, and then drop dramatically over the next few hours to several ng/mL or ng/g, and finally to be at extremely low or undetectable concentrations by 24h apparently due to extensive biotransformation, and redistribution to body fat.  相似文献   

19.
Huestis and Cone reported in [J. Anal. Toxicol. 22 (1998) 445] that serial monitoring of Delta9-THC-COOH/creatinine ratios in paired urine specimens collected at least 24h apart could differentiate new drug use from residual Delta(9)-THC-COOH excretion following acute marijuana use in a controlled setting. The best accuracy (85.4%) for predicting new marijuana use was for a Delta(9)-THC-COOH/creatinine ratio > or = 0.5 (dividing the Delta9-THC-COOH/creatinine ratio of specimen no. 2 by the specimen no. 1 ratio). In previous studies in this laboratory [J. Anal. Toxicol. 23 (1999) 531 and Forensic Sci. Int. 133 (2003) 26], urine specimens were collected from chronic marijuana users > or = 24 h or > = 48 h apart in an uncontrolled setting. Subjects with a history of chronic marijuana use were screened for cannabinoids with the EMIT II Plus cannabinoids assay (cut-off 50 ng/ml) followed by confirmation for Delta9-THC-COOH by GC-MS (cut-off 15 ng/ml). Creatinine was analyzed as an index of dilution. The objective of the present study was to evaluate whether creatinine corrected specimens could differentiate new marijuana or hashish use from the excretion of residual Delta(9)-THC-COOH in chronic marijuana users based on the Huestis 0.5 ratio. Urine specimens (N=376) were collected from 29 individuals > or = 96 h between urine collections. The mean urinary Delta9-THC-COOH concentration was 464.4 ng/ml, mean Delta9-THC-COOH/creatinine ratio (ng/(ml Delta9-THC-COOH mmoll creatinine)) was 36.8 and the overall mean Delta9-THC-COOH/creatinine ratio of specimen 2/mean Delta9-THC-COOH/creatinine ratio of specimen 1 was 1.37. The Huestis ratio calculation indicated new drug use in 83% of all sequentially paired urine specimens. The data were sub-divided into three groups (Groups A-C) based on mean Delta9-THC-COOH/creatinine values. Interindividual mean Delta9-THC-COOH/creatinine values ranged from 4.7 to 13.4 in Group A where 80% of paired specimens indicated new drug use (N=10) and 20.4-39.6 in Group B where 83.6% of paired specimens indicated new drug use (N=7). Individual mean Delta9-THC-COOH/creatinine values ranged from 44.2 to 120.2 in Group C where 84.5% of paired urine specimens indicated new marijuana use (N=12). Correcting Delta9-THC-COOH excretion for urinary dilution and comparing Delta9-THC-COOH/creatinine concentration ratios of sequentially paired specimens (collected > or = 96 h apart) may provide an objective indicator of ongoing marijuana or hashish use in this population.  相似文献   

20.
Because serum Procalcitonin is reported to be a valid postmortem marker of sepsis, this prospective study was carried out to determine whether the semi-quantitative PCT-Q((R))-Test (B.R.A.H.M.S., Germany) is a reliable indicator of postmortem Procalcitonin (PCT) serum levels, thus enabling a quick "tableside" diagnosis of sepsis. Postmortem PCT-levels of 70 forensic and 78 clinical-pathological autopsy cases (n=148) were examined using the B.R.A.H.M.S-PCT-Q-Test during autopsy. 27 cases were categorized as the cases of sepsis according to the ACCP/SCCM Consensus Conference criteria. 121 cases were assigned to the non-sepsis group. Among the 148 cases, 18 samples could not be analyzed by the reason of strong hemolysis. Using a cut-off point of 2 ng/ml, 20 cases of sepsis were identified (true positive) whereas 3 cases of sepsis were not detected (false negative). In the non-sepsis group (107 cases) 6 cases showed a positive testing (false positive). When applied within 48 h postmortem, the PCT-Q-Test showed a sensitivity of 86.96% and a specificity of 94.39% (at cut-off 2 ng/ml). Likelihood ratios and positive predictive values proved to be lower in the forensic autopsy group (PPV: 59.3% in forensic case vs. 85.1% in clinicopathological cases; NPV: 98.73% in forensic cases vs. 95.2% in clinicopathological cases). The PPVs using a cut-off point of 10 ng/ml were 100% in both groups independent of sepsis prevalences. The results show, that a high NPV for prevalences ranging from 3% to 30% can be reached using a 2 ng/ml cut-off point, whereas a cut-off of 10 ng/ml ensures a high PPV for the respective prevalences in the absence of exclusion criteria. The study provides strong evidence that the introduction of rapid diagnostic test (RDTs) of postmortem PCT serum levels may be useful in achieving rapid distinction between sepsis and non-sepsis-related causes of death, especially in conjunction with the medical case history and further autopsy results. In addition, the use of RDTs enables clinicians to conduct an evidence-based validation of clinical diagnosis, thus facilitating future clinical decision-making.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号