共查询到20条相似文献,搜索用时 15 毫秒
1.
Charles W. Beason M.S. James R. Jauchem Ph.D. C. D. Clark III B.S. James E. Parker M.S. David A. Fines B.S. 《Journal of forensic sciences》2009,54(5):1113-1118
Abstract: Conducted energy weapons (such as the Advanced TASER X26 model produced by TASER International), incapacitate individuals by causing muscle contractions. To provide information relevant to development of future potential devices, a “Modifiable Electronic Stimulator” was used to evaluate the effects of changing various parameters of the stimulating pulse. Muscle contraction was affected by pulse power, net/gross charge, pulse duration, and pulse repetition frequency. The contraction force increased linearly as each of these factors was increased. Elimination of a precursor pulse from X26‐like pulses did not have a significant effect on the normalized force measured. Muscle‐contraction force increased as the spacing increased from 5 to 20 cm, with no further change in force above 20 cm of spacing. Therefore, it is suggested that any future developments of new conducted energy weapons should include placement of electrodes a minimum of 20 cm apart so that efficiency of the system is not degraded. In the current study, the 50% probability of fibrillation level of X26‐like pulses ranged from 4 to 5 times higher than the X26 itself. Relatively large variations about the X26 operating level were found not to result in fibrillation or asystole. Therefore, it should be possible to design and build an X26‐type device that operates efficiently at levels higher than the X26. 相似文献
2.
Abstract: Electronic control devices (including the Advanced TASER® X26 model produced by TASER International) incapacitate individuals by causing muscle contractions. To provide information relevant to development of future potential devices, effects of monophasic square waves with different parameters were compared with those of the X26 electronic control device, using two animal models (frogs and swine). Pulse power, electrical pulse charge, pulse duration, and pulse repetition frequency affected muscle contraction. There was no difference in the charge required, between the square waveform and the X26 waveform, to cause approximately the same muscle‐contraction response (in terms of the strength‐duration curve). Thus, on the basis of these initial studies, the detailed shape of a waveform may not be important in terms of generating electro‐muscular incapacitation. More detailed studies, however, may be required to thoroughly test all potential waveforms to be considered for future use in ECDs. 相似文献
3.
James R. Jauchem Ph.D. 《Journal of forensic sciences》2015,60(Z1):S116-S129
TASER® conducted electrical weapons (CEWs) are an important law-enforcement tool. The purposes of this study are a) to review recent literature regarding potential pathophysiological responses to applications of CEWs, and other related issues and b) to evaluate whether enough data exist to determine the acceptability of longer-duration (or repeated) exposures. This is a narrative review, using a multidisciplinary approach of analyzing reports from physiological, legal-medical, and police-strategy literature sources. In general, short-duration exposures to CEWs result in limited effects. Longer-duration or repeated exposures may be utilized with caution, although there are currently not enough data to determine the acceptability of all types of exposures. Data examined in the literature have inherent limitations. Appropriateness of specific types of CEW usage may be determined by individual police agencies, applying risk/benefit analyses unique to each organization. While more research is recommended, initial concepts of potential future long-duration or repeated CEW applications are presented. 相似文献
4.
James A. Comeaux B.S. James R. Jauchem Ph.D. D. Duane Cox Carrie C. Crane B.Appl.Arts Sci. John A. D'Andrea Ph.D. 《Journal of forensic sciences》2013,58(4):1026-1031
Conducted energy weapons (CEWs) (including the Advanced TASER® X26 model produced by TASER International, Inc.) incapacitate individuals by causing muscle contractions. In this study using anesthetized swine, the potential incapacitating effect of primarily monophasic, 19‐Hz voltage imposed by the commercial CEW was compared with the effect of voltages imposed by a laboratory device that created 40‐Hz square waves. Forces of muscle contraction were measured with the use of strain gauges. Stimulation with 40‐Hz square waves required less pulse energy than stimulation with the commercial CEW to produce similar muscle contraction. The square‐pulse stimulation, at the higher repetition rate, caused a more complete tetanus at a lower energy. Use of such a simple shape of waveform may be used to make future nonlethal weapon devices more efficient. 相似文献
5.
James R. Jauchem Ph.D. Jennie M. Burns Ph.D. William B. Voorhees M.S. Michael B. Jirjis Ph.D. 《Journal of forensic sciences》2019,64(4):1196-1202
In laboratory studies of the pig Sus scrofa, hematocrit has consistently increased after conducted‐electrical‐weapon (CEW) exposures, possibly due to contraction of the spleen. Splenectomized animals and intact sham control animals were exposed, each for 30 sec, to a benchtop‐produced electrical waveform of net charge levels similar to those of some CEWs. Changes in the blood were compared statistically. Hematocrit increased significantly in both splenectomized and sham animals. There were no significant main‐effect differences between values of hematocrit from the two groups. There were, however, significant interactive effects of time and splenectomy for hematocrit, red blood cell count, and hemoglobin. After peak values were reached for these variables, values returned toward baseline levels more slowly in splenectomized animals. This may have been due to the lack of a spleen to sequester red blood cells (thereby resulting in more cells remaining in the general circulation), unlike sham animals with intact spleens. 相似文献
6.
Asser H. Thomsen M.D. Anne Grethe Jurik D.M.Sc. Lars Uhrenholt Ph.D. D.C. Annie Vesterby D.M.Sc. 《Journal of forensic sciences》2010,55(4):1126-1129
Abstract: Ankylosing spondylitis (AS) is a chronic rheumatic disease that causes spinal rigidity with an increased risk of spinal fractures. We present a case report where a middle‐aged man, in apparent good health, died following a fall from his bike. Postmortem computed tomography (CT) showed several fractures in the cervical and thoracic spine, with displacement into the spinal canal as well as spinal changes consistent with AS. The cause of death was determined to be upper spinal cord injury caused by cervical spinal fractures that were facilitated by spinal rigidity from AS. Further investigation into the medical records revealed that the decedent had previously been treated for AS. This case report illustrates the importance of obtaining a detailed medical history when investigating deaths, including nonfatal conditions, such as AS. Furthermore, it shows the value of CT in the evaluation of the mechanism and manner of death. 相似文献
7.
James R. Jauchem Ph.D. 《Journal of forensic sciences》2010,55(2):521-526
Abstract: Conducted energy weapons (CEWs) are used by law‐enforcement personnel to incapacitate individuals quickly and effectively, without causing lethality. CEWs have been deployed for relatively long or repeated exposures during law‐enforcement operations. The purpose of this technical note is to describe, in detail, some aspects of an anesthetized swine model used in our laboratory and to answer specific questions related to the model. In particular, tiletamine/zolazepam‐induced, propofol‐maintained anesthesia appears to be a useful technique for studying effects of CEW applications on muscle contraction and blood factors such as muscle enzymes. Because effects of CEWs on breathing have not been fully elucidated, a spontaneously breathing model is preferable to one in which mechanical ventilation is supplied. Placement of the swine in a supine position may facilitate measurement of muscle contractions, without compromising other physiological parameters. 相似文献
8.
Eun‐Jung Park M.D. Sang‐Cheon Choi M.D. Jung‐Hwan Ahn M.D. Young‐Gi Min M.D. 《Journal of forensic sciences》2013,58(1):179-183
The objectives of our study were to investigate the dose–response relationship of the TASER X26 discharge duration in an anesthetized swine model. Fourteen swines were anesthetized and then exposed to TASER X26 discharge for 5 sec (n = 5) or for 10 sec (n = 6). The sham control group (n = 3) was anesthetized and studied using the same protocol except TASER X26 discharges during the experiments. Hemodynamic parameters were obtained. Blood pressure and total peripheral resistance decreased significantly after TASER discharge and returned to baseline value at 15 min after 5 sec of TASER discharge but did not return to baseline values during the 30‐min observation period after 10 sec of TASER discharge. Repetitive TASER X26 discharge resulted in adverse physiologic events with a dose–response relationship related to the duration of TASER X26 discharge in an anesthetized swine model. 相似文献
9.
Jauchem JR 《Journal of forensic sciences》2011,56(Z1):S229-S233
Conducted energy weapons (CEWs) are used by law enforcement personnel to incapacitate individuals quickly and effectively, without intending to cause lethality. CEWs have been deployed for relatively long or repeated exposures in some cases. In laboratory animal models, central venous hematocrit has increased significantly after CEW exposure. Even limited applications (e.g., three 5-sec applications) resulted in statistically significant increases in hematocrit. Preexposure hematocrit was significantly higher in nonsurvivors versus survivors after more extreme CEW applications. The purpose of this technical note is to address specific questions that may be generated when examining these results. Comparisons among results of CEW applications, other electrical muscle stimulation, and exercise/voluntary muscle contraction are included. The anesthetized swine appears to be an acceptable animal model for studying changes in hematocrit and associated red blood cell changes. Potential detrimental effects of increased hematocrit, and considerations during law enforcement use, are discussed. 相似文献
10.
Emmanouil I. Sakelliadis M.D. M.Sc. Ph.D. Konstantinos D. Katsos M.D. Ph.D. Evmorfili I. Zouzia M.D. Konstantinos Moraitis B.Sc. M.Sc. Ph.D. Chara A. Spiliopoulou Pharm.D. M.D. Ph.D. 《Journal of forensic sciences》2020,65(3):991-994
We present two cases of elevator-related deaths that occurred in two different elevators, and deaths were caused by a similar, but unusual, mechanism. An elevator is a platform or compartment housed in a shaft for raising and lowering people or things to different levels. Elevator-related deaths and injuries are rarely reported in the literature. In most of these cases, cause of death was attributed to falls. It seems that most of the elevator accidents may be attributed to factors related to device maintenance inadequacies or even to device malfunctioning. In our cases, both elevator cars were not equipped with full-length inner doors, thus allowing both accidents to occur. Since 2014, the European Union adopted a relative directive, which imposes the need to equip all elevators with such full-length doors. The enforcement of the above-mentioned EU Directive is crucial, in order to prevent similar accidents in the future. 相似文献
11.
Petar Škavić M.D. Nikica Šprem Ph.D. Antun Kostelić Ph.D. 《Journal of forensic sciences》2015,60(5):1380-1382
Animal‐inflicted injuries to humans are a major public health problem around the world resulting in great morbidity, money loss, and mortality. They are related to wild and domestic animals alike. Animals can cause injuries by various mechanisms—biting, stinging, crushing, goring, stomping, butting, kicking, pecking, etc. We present a case of a ram's attack with fatal consequences. A 4‐year‐old, 120 kg jezersko‐sol?ava breed ram with prior history of aggressive behavior inflicted multiple injuries to his 83‐year‐old owner, who died in the hospital a few hours later due to severe blunt force injuries sustained in the attack. The autopsy revealed the cause of death to be multiple injuries of the thorax and the head. Sheep, even though they are not considered aggressive or large farm animals such as cattle and horses, can inflict serious injuries with devastating results. 相似文献
12.
Wanying Cao HBSc Eugene Liscio PEng Hannah Elizabeth Ruffo HBSc Corrin Marie Doucette BSc Yu Ran Zhou BSc 《Journal of forensic sciences》2023,68(2):647-654
TASER® weapons are conducted energy weapons (CEWs) that are frequently used by police departments around the world. CEWs can be deployed in two methods: drive stun application and probe deployment. This study aims to examine damages caused by TASER devices on fabrics and whether types of fabric material and TASER models could contribute to different damage features. Three types of white fabric were used, including 100% cotton, 100% polyester, and 65:35 polyester-cotton blend. Three models: TASER X26P, TASER X2, and TASER 7 were shot onto each type of fabric, with five repetitions each. Each damaged area on the fabric caused by a probe is a sample (n = 90) and was examined with a Keyence digital microscope. Images were captured by the Keyence microscope and measurements were recorded, including damage dimensions, fabric condition, evidence of burning, and extra findings. The presence of fused yarn ends was found to be statistically significant across the fabric types, and no damage features were found that may assist in the identification of TASER models. Other damage features including damage dimensions, discoloration, and fiber deformation were not found to be showing apparent differences according to statistical analysis. The conclusions made by this research should be used with caution due to the small sample size. 相似文献
13.
Konstantinos D. Katsos M.D. Emmanouil I. Sakelliadis M.D. M.Sc. Ph.D. Konstantinos Moraitis M.Sc. Ph.D. Chara A. Spiliopoulou Pharm.D. M.D. Ph.D. 《Journal of forensic sciences》2019,64(5):1559-1562
A case of a ram attack that caused injuries to a 73‐year‐old man is presented. The deceased survived the attack and had the opportunity to speak with a friend over the phone before being transferred to the hospital. After a 21‐day hospitalization, the patient passed away. A postmortem examination was performed to ascertain the cause of death. The autopsy findings are presented along with a brief review of the literature. Attacks by agricultural animals (or livestock) around the world are reported in the scientific literature. Fatalities from ram attacks are extremely rare. The need to implement specific codes in the ICD system, relevant to each animal attack, appears to be of great importance, in order to allow tracking of animal‐related deaths. 相似文献
14.
Elena Tugaleva M.D. Donald R. Gorassini Ph.D. Michael J. Shkrum M.D. 《Journal of forensic sciences》2016,61(6):1498-1507
Hanging deaths from investigation standpoint are rarely problematic. Unusual circumstances can on occasion raise suspicion of foul play. Associated neck injuries are reported in the literature with variable frequency (from 0% to 76.8%). This study retrospectively analyzed 755 hanging deaths in Ontario (Canada) to evaluate the demographic features and circumstances of hanging fatalities, and the frequency of hanging‐related neck injuries. A number of cases showed unusual/special circumstances (e.g., complex, double suicides, restraints). Among 632 cases with complete autopsies, hyoid and larynx fractures were present in 46 cases (7.3%) with the most common being isolated hyoid fractures. The incidence of cricoid fractures was 0.5% and cervical spine injuries, 1.1%. A higher incidence of neck injuries occurred among males, long drop hangings, and in cases with complete suspension. There was a tendency for the number of fractures to increase with increasing age and weight of the deceased. 相似文献
15.
Anna Smędra‐Kaźmirska M.D. Ph.D. Maciej Barzdo M.D. Ph.D. Agnieszka P. Jurczyk M.D. Ph.D. Jarosław Berent M.D. Ph.D. 《Journal of forensic sciences》2015,60(5):1365-1368
Pursuant to the Polish Weapons and Ammunitions Law, muzzle‐loading black powder weapons, manufactured before 1885, or their replicas, as well as suitable projectiles, can be possessed legally without registration and special licenses. The aim of the study was to assess the penetration depth of projectiles fired from a black powder weapon, replica of Colt Navy of 1851, in 20% gelatin blocks and to compare the obtained results with the actual injuries found on autopsy of a 78‐year‐old man who had committed suicide. In the experiments, we used the black powder weapon and ammunitions, as well as gelatin blocks serving as a soft tissue model. We ascertained that solid spherical projectiles fired from black powder weapons cause extensive injuries, especially in the initial segment of the wound canal. Additionally, based on the presence and location of the wad in the wound canal, the distance from which the shot was fired can be determined. 相似文献
16.
Abstract: An unexpected infant death is usually investigated with a complete autopsy. If evidence of prior trauma is found at autopsy in these cases, suspicion is raised for nonaccidental trauma. In a young infant, the residua of trauma received during birth has the potential to be incorrectly interpreted as nonaccidental trauma. We report a the findings of a 4 1/2‐month‐old‐infant that died unexpectedly with a healing linear skull fracture and a circular lesion over the calvarium found at autopsy. Though this lesion was concerning, the remainder of the autopsy and the histological findings did not support a diagnosis of recent trauma. Review of the literature describing birth injuries made the diagnosis of healing, residual birth trauma more convincing in this case. 相似文献
17.
Abstract: This study examined the effects of heat on the amplification of DNA from the dental pulp of Sus scrofa molars and investigated the protection afforded to the pulp tissue by the dental enamel, alveolar process, and soft tissue of the head. Segments of defleshed maxilla and mandible encasing the first molar (n = 60) were subject to a range of temperatures for 15 min. Dental pulps were retrieved. Amplifications using three‐primer and four‐primer multiplexes showed no degradation of the largest fragment following exposure to 450°C. Amplifications in the three‐primer multiplex (283 bp) were successful following exposure to 525°C in maxillary samples only. This study revealed the enamel density of maxillary molars to be greater than mandibular molars in Sus scrofa. Following incineration of intact heads for 15 min (n = 10) and 1 h (n = 4) at an average temperature of 625°C, amplifications of the largest fragment (450 bp) were successful from both maxillary and mandibular teeth. 相似文献
18.
H. Theodore Harcke M.D. Timothy Monaghan M.D. Nicole Yee B.S. Louis Finelli M.D. 《Journal of forensic sciences》2009,54(5):1123-1126
Abstract: Our objective is to document the recovery of DNA from the spinal cord or surrounding dura mater in 11 cases of severely burned human remains. Radiographs established that portions of charred tissue contained spine segments. Multidetector computed tomography (MDCT) revealed that each spine specimen contained an intact spinal cord remnant. A full DNA profile was obtained from seven specimens using spinal cord dura mater in six specimens and spinal cord medulla in one specimen. A partial profile was obtained from four specimens (spinal cord dura mater, 2; spinal cord medulla, 2). Bone and muscle surrounding the spinal cord appear to insulate nucleic acid containing tissue from critical thermal degradation. The spinal cord, which is easily identified by MDCT examination of remains and easily recovered at the postmortem examination, can be a source of DNA with extraction yields comparable with other tissue sources. Specimens of dura mater are preferable as processing time is faster than bone. 相似文献
19.
Sebastian N. Kunz M.D. Bettina Zinka Ph.D. Sybille Fieseler M.D. Matthias Graw Ph.D. Oliver Peschel Ph.D. 《Journal of forensic sciences》2012,57(6):1591-1594
Abstract: Conducted electrical weapons (CEWs) such as the TASER® M‐ and X‐series deliver short high‐voltage, low‐current energy pulses to temporarily paralyze a person by causing electrical interruption of the body’s normal energy pulses. Despite many scientific publications, which classify the health risks of an appropriate use of the TASER device as minor, there still is a continuous uncertainty about possible side effects with human application. Based on a literature search of the National Library of Medicine’s MEDLINE database’s PubMed system of current publications, the following article describes the mechanisms by which the device operates and discusses possible pathophysiological consequences. The majority of current human literature has not found evidence of clinical relevant pathophysiological effects during and after an exposure of professionally applied CEWs. However, to be able to exclude possible health risks, a medical checkup of people who have been exposed to CEWs is essential. 相似文献