首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Electrokinetic injection (EI) is the primary method used in forensic laboratories to load amplified PCR product in capillary electrophoresis for short tandem repeat (STR) fragment separation. Because all samples subjected to capillary electrophoresis use internal lane standard (ILS), this study investigated the consequence of varying the volume of ILS and its effects on allele peak heights and number of alleles detected. Results demonstrated that when the volume of ILS is reduced, the average peak height and number of alleles increased, thereby increasing the sensitivity of the detection method. Sizing anomalies were observed; however, they did not adversely affect accuracy and precision. The method developed in this study offers a simple and universal procedure to increase the alleles detected in forensic STR analysis. Reducing the volume of ILS to achieve greater sensitivity is applicable to all STR amplification kits and capillary electrophoresis instruments currently used in forensic DNA analysis.  相似文献   

2.
Common analytical methods used for identifying samples obtained from clandestine laboratories were evaluated for their ability to differentiate between possible amphetamine isomers and homologs. A series of ring-substituted (4-methyl, 4-methoxy, and 3,4-methylenedioxy) amphetamine and N-methylphenethylamine isomers was analyzed using color tests, thin-layer chromatography, gas chromatography/mass spectrometry (GC/MS) and GC/infrared (GC/IR). The N-acetyl derivatives of the isomers were analyzed using GC/IR/MS. GC/IR/MS readily differentiated the 4-methylphenylalkylamine isomers. MS and IR spectra were also obtained for each pair of the 4-methoxyphenylalkylamine isomers and the 3,4-methylenedioxyphenylalkylamine isomers, but differentiation via GC/IR/MS was difficult. The N-acetyl derivatives of each pair of isomers could be readily differentiated using GC/IR/MS. Good library researchable spectra for N-acetylamphetamine could be obtained for IR identification with 10 ng (on-column) and MS identification with 2 ng. The spectrometrically independent IR and MS data obtained for the N-acetyl derivatives indicated that the combination of GC/IR/MS can add a significant level of confidence in the analysis of ring-substituted arylalkylamines.  相似文献   

3.
The goal of this paper is to demonstrate that electrospray mass spectrometry when used with spectral libraries becomes a useful method for rapid identification of inorganic oxidizers commonly present in commercial and improvised explosives. Electrospray ionization mass spectra (ESI-MS) of oxidizers reveal a series of characteristic cluster ions. Such a set of cluster ions can be regarded as a "fingerprint" of a particular oxidizer. With the aid of a spectral library, tentative identification of inorganic oxidizer becomes automated and an easy-to-implement process. The oxidizer identity may be further confirmed by using tandem mass spectrometry (MS/MS). Because it is not necessary to separate the components before analysis, results become available in real time. Little sample consumption and the ease of sample preparation should also be noted. The methodology can be readily employed on various ESI-MS systems that are already in use in analytical laboratories. This is another important benefit as the ESI-MS instrumentation is becoming increasingly common in forensic laboratories.  相似文献   

4.
Comprehensive two-dimensional gas chromatography (GC x GC) is applied to analysis of drug standard mixtures containing 78 drugs of interest in forensic samples. For this study, underivatised drugs were employed. While several of the drugs were not detected at the low concentrations employed in the samples, most could be satisfactorily assigned their first and second dimension retentions in the GC x GC retention plane. For this study, time-of-flight mass spectrometry (TOFMS) detection was used. The enhanced separation possible in GC x GC is demonstrated, and typical linearity and apparatus precision are shown for tramadol, diazepam, olanzapine and desipramine using selected qualifier ions. Mass spectral library search quality for the detection of drugs in a selection of authentic forensic cases, along with retention position in the 2D retention plane, is used to support positive identification of the presence of the drugs. The analysis of 'difficult' drugs paracetamol and phenytoin is shown to produce anomalous chromatographic peak shape in the 2D plane, whereas most drugs gave acceptable peak shapes. The GC x GC technique was applied to screening drugs in forensic samples, with either flame ionisation (FID) or TOFMS detection, and compared favourably with conventional single column GC-MS analysis when tested for diazepam in an authentic forensic study.  相似文献   

5.
目的建立血样中褪黑素的固相萃取方法。方法采用OasisHLB固相萃取柱提取,GC/NPD定量检验,GC/MS定性检验。结果血样中褪黑素平均萃取回收率达80%以上,最低检出限0.02μg/mL,线性良好,相关系数R2=0.9978。结论该方法操作简便快速,提取回收率高,重现性好,提取物干净,可用于实际案件当中。  相似文献   

6.
Since the early 1990s, the FBI Laboratory has sponsored Scientific Working Groups to improve discipline practices and build consensus among the forensic community. The Scientific Working Group on the Forensic Analysis of Chemical, Biological, Radiological and Nuclear Terrorism developed guidance, contained in this document, on issues forensic laboratories encounter when accepting and analyzing unknown samples associated with chemical terrorism, including laboratory capabilities and analytical testing plans. In the context of forensic analysis of chemical terrorism, this guidance defines an unknown sample and addresses what constitutes definitive and tentative identification. Laboratory safety, reporting issues, and postreporting considerations are also discussed. Utilization of these guidelines, as part of planning for forensic analysis related to a chemical terrorism incident, may help avoid unfortunate consequences not only to the public but also to the laboratory personnel.  相似文献   

7.
The aim of this study was to evaluate the performance of a technique for the simultaneous testing of opiates, cocaine and metabolites in hair by interlaboratory comparison. Sixteen forensic and clinical laboratories with different degrees of experience in hair analysis participated voluntarily in the study (no selection criteria were applied). The suggested analytical procedure, the one routinely used in our laboratory, consisted of incubation in HCl 0.1N (45 degrees C, overnight), solid phase extraction (with Bond Elut Certify) cartridges), derivatisation (trimethylsilyl (TMS) derivatives) and GC-MS analysis. Three different mixtures of finely cut (1 mm or less) hair were prepared using drug-users' and drug-free hair: one 'negative' sample (<0.1 ng/mg for morphine, 6-acetylmorphine (6AM), cocaine and benzoylecgonine (BE)), one 'low concentration' sample (between 0.5 and 2 ng/mg) and one 'high concentration' sample (>3 ng/mg). Accuracy and precision (CV% lower than 5.1, 9.9, 5.2, 3.8, 7.3 and 8.3% for morphine, 6AM, codeine, cocaine, BE, and methylecgonine (ME), respectively; range 0.5-5 ng/mg) of the method and homogeneity of the mixtures were evaluated in our laboratory by intraday (CV% lower than 12% for all analytes) and interday analyses (CV% lower than 17% for all analytes except 6AM, 25%). Participants in the study were grouped into: (1) laboratories (n = 6) obtaining the best qualitative and quantitative values, corresponding to those with long experience in hair analysis; (2) laboratories (n = 5) with no reported false positive and/or false negatives; (3) laboratories (n = 5) with one or more reported false positives/false negatives. The results obtained by the labs of the first group were used as reference values. The scatter of data was similar to those obtained in other published studies.  相似文献   

8.
Toxicological evaluation of postmortem urine collected from a 41-year-old deceased white male detected anhydroecgonine ethyl ester (ethylecgonidine, AEEE), a transesterification product of smoked cocaine co-abused with ethanol. A solid phase extraction (SPE) method was used to extract cocaine, AEEE, and related metabolites from urine. SPE on a 1 mL urine sample from the decedent followed by GC-MS detected AEEE. Other metabolites identified by GC-MS included cocaine, cocaethylene, and anhydroecgonine methyl ester (AEME). To determine whether some or all of the AEEE was artifactually produced in the heated GC injector port, an alternative LC-MS method was developed. LC/MS following SPE found at least 50 ng/mL of AEEE in the extract. The mass fragmentation (MS/MS and MS3) of AEEE detected in the urine was compared to spectra of authentic, synthesized compound. AEEE is a potential additional forensic marker for the co-abuse of smoked cocaine and ethanol.  相似文献   

9.
Liquid-liquid or solid phase extraction methods are widely used for isolating analytes from urine, blood and other samples. But the preparation procedures of the samples are laborious, intensive, and costly. In addition, the organic solvents used are toxic to both the human body and the environment. An accurate, simple and rapid method for analysis of some compounds is required for forensic, judicial, and clinical purposes. Solid phase micro-extraction membrane (SPMEM) is a new, simple and solventless preparation technique. It integrates sampling, extraction and concentration into a single step and has the advantages of both the solid phase micro-extraction (SPME) and membrane separation. In this paper, a new kind of membrane used for the solid phase micro-extraction was prepared with amide compounds. The extraction conditions such as adsorption time, desorption solvents, methods and time are studied and optimized. The dichlorvos in the blood, morphine and phenobarbital in the urine were perfectly separated by using this solid phase micro-extraction membrane, and were tested by gas chromatograph-mass spectrometer (GC-MS). All the data were acquired in scan mode except that of morphine which was obtained in a selected ion monitoring (SIM) mode. Ions used for identification were those with m/z 57, 115, 162, 215, 285.  相似文献   

10.
Abstract: The analysis of mixtures of “crystal meth” (usually comprised of methyl sulfone [MS] and methamphetamine [MA]) by gas chromatography‐mass spectrometry (GCMS) is routine in many forensic drug laboratories. The utilization of Raman spectroscopy for the identification of such mixtures quickly and without the need for a separation technique is discussed. Samples were dissolved in water and Raman spectra of the resulting aqueous solutions were collected. By comparing these spectra to spectra of methylsulfone and MA mixtures of known composition, an indication of the composition of the sample can be obtained in only a few minutes. This spectral comparison also can be used as a semi‐quantitative analysis of MA concentrations in such exhibits.  相似文献   

11.
An impressively large number of clandestinely produced controlled-substance analogues (designer drugs) of amphetamine with high structural variety have been encountered in forensic samples in recent years. The continuous designer drug exploration and their widespread consumption results in an increasing number of reports regarding abuse and intoxication. This study presents the analytical properties of a series of new fluoro-methoxy-substituted controlled-substance analogues of amphetamine. Three ring positional isomeric fluoroamphetamines, two isomeric fluoromethoxyamphetamines, two N-alkyl 4-fluoroamphetamines, and one 4-fluorophenylbutan-2-amine were identified and differentiated by gas chromatography-mass spectrometry (GC-MS), 1H- and 13C-nuclear magnetic resonance (NMR), and gas chromatography-infrared spectroscopy (GC-IR). The regioisomeric 2-, 3-, and 4-fluoroamphetamines and the regioisomeric fluoro-methoxyamphetamines show virtually identical mass spectra so that this method is insufficient to discriminate between these closely related compounds. The mass spectra of the acetylated compounds allowed a differentiation of the 4-fluoroamphetamine from its regioisomeric 2- and 3-fluoroamphetamines. The gas chromatographic properties of the three regioisomeric fluoroamphetamines and their acetylated and trifluoroacetylated derivatives are also so similar that a complete separation of these compounds could not be achieved under GC-MS conditions. The two isomeric compounds 5-fluoro-2-methoxyamphetamine and 3-fluoro-4-methoxyamphetamine on the other hand showed significant different gas chromatographic retention times so that a separation was uncomplicated. The trifluoroacetylation of these compounds proved to be an effective method for their mass spectral differentiation. Gas chromatography-infrared spectroscopy and 1H- and 13C-nuclear magnetic resonance allowed an unequivocal differentiation of all studied regioisomeric fluoroamphetamines and fluoro-methoxyamphetamines.  相似文献   

12.
The chemical analysis of gamma-hydroxybutyric acid (GHB) in most forensic laboratories is complicated by the highly polar nature of the GHB molecule, which makes it unsuitable for direct analysis by gas chromatography (GC). Consequently, a popular analytical approach is to convert GHB into the corresponding lactone or a derivative compound that is then identified by mass spectrometry employed in conjunction with GC (GC/MS). An alternative approach is presented here where GHB may be isolated as a free acid specie from complex aqueous solutions employing a liquid-liquid extraction technique. This approach can yield a relatively pure residue of GHB that presents an infrared transmission spectrum that is sufficiently distinct for identification purposes. Infrared spectroscopy (IR) is a very popular technique that is available to most crime laboratories. The liquid-liquid extraction behavior of GHB is examined in detail and the uniqueness of the infrared spectrum is discussed.  相似文献   

13.
In the spring of 2000, the National Institute of Standards and Technology and nineteen participants conducted a comparison of smokeless powder additive compositional measurements. The purpose of this exercise was to determine the state-of-the-practice for forensic smokeless powder determinations. For the comparison, two handgun reloading powder samples were mixed and were compositionally evaluated for homogeneity by NIST. Participant laboratories included military, academic, and state/local, federal, and international forensic agencies. We solicited qualitative data identifying nitroglycerin, diphenylamine, N-nitrosodiphenylamine, and ethyl centralite. In addition, some laboratories provided identification of additional ingredients, such as nitrocellulose, or reported other measurements, such as dimensional morphology. In this paper, laboratory identification of the smokeless powder additives and a summary of the measurement methods used for the evaluations are presented. All laboratories correctly identified NG and the major stabilizers. Some disparity between laboratories was noted for the identification of minor (<0.01% by weight) stabilizers and stabilizer decomposition products.  相似文献   

14.
The AmpliType HLA DQ alpha forensic DNA amplification and typing kit is designed for the qualitative analysis of the human leukocyte antigen (HLA) DQ alpha alleles present in deoxyribonucleic acid (DNA) extracted from forensic samples. The AmpliType kit is the first forensic DNA typing product based on the GeneAmp polymerase chain reaction (PCR) process. The kit was evaluated by five forensic science laboratories (test sites) to assess their ability to perform DNA typing using PCR on sample types typically encountered by forensic laboratories. None of the DNA-containing samples was mistyped. Of the 180 DNA-containing samples analyzed, results were reported for 178 (98.9%). Of the 178 samples with results, all were correctly typed. Two sites did not report a result for one sample each. Four of the five laboratories experienced no significant levels of contamination in the DNA-containing samples. At the one site with the highest number of DNA-containing samples with contamination, the typing results were not compromised. This site was able to correct the contamination problem through simple procedural changes and stricter attention to sterile technique. Blank controls were important to monitor contamination. In conclusion, the trial demonstrated that forensic science laboratories are capable of setting up a PCR-based DNA typing laboratory and successfully using the AmpliType HLA DQ alpha forensic DNA amplification and typing kit to analyze forensic samples.  相似文献   

15.
目的研究图像降噪和图像增强方法对人脸识别系统识别性能的影响,以期为人脸识别系统应用过程中的图像处理方法选取提供理论指导和技术方案。方法收集33起人像鉴定领域实际案例中的人脸图像素材,研究以高斯滤波和小波变换为代表的图像降噪技术以及具有边缘保持和小波变换特性的单帧图像超分辨率增强技术对人脸识别系统识别性能的影响,并对不同图像处理方法对人脸识别性能的影响进行量化比较分析。结果本文研究的图像降噪技术均显著提高了人脸识别系统的识别准确性,而图像增强技术虽然提高了人脸图像显示效果,但对人脸识别系统的识别性能无正向促进作用。此外,高斯模糊图像处理的图像降噪方法虽然简单,但与本文研究的其他方法比较,其在人脸识别系统识别性能改善方面效果最显著。结论人脸图像质量对人脸识别系统的识别性能具有显著影响,可以通过图像处理技术改善人脸图像质量进而提高人脸识别系统的识别准确性。其中,图像降噪处理可以显著提高人脸识别系统的识别性能,且比图像增强技术更适合于实际人像鉴定应用中的人脸识别系统识别性能增强。  相似文献   

16.
The authors give the comparative analysis of Russian and foreign forensic medical methods of species character identification of the blood from the stains on the material evidences and bone fragments. It is shown that for this purpose it is feasible to apply human immunoglobulin G (IgG) and solid phase enzyme immunoassay (EIA) with the kit "IgG general-EIA-BEST". In comparison with the methods used in Russia this method is more sensitive, convenient for objective registration and computer processing. The results of experiments shown that it is possible to use the kit "IgG general-EIA-BEST" in forensic medicine for the species character identification of the blood from the stains on the material evidences and bone fragments.  相似文献   

17.
Erythritol tetranitrate (ETN), an ester of nitric acid and erythritol, is a solid crystalline explosive with high explosive performance. Although it has never been used in any industrial or military application, it has become one of the most prepared and misused improvise explosives. In this study, several analytical techniques were explored to facilitate analysis in forensic laboratories. FTIR and Raman spectrometry measurements expand existing data and bring more detailed assignment of bands through the parallel study of erythritol [15N4] tetranitrate. In the case of powder diffraction, recently published data were verified, and 1H, 13C, and 15N NMR spectra are discussed in detail. The technique of electrospray ionization tandem mass spectrometry was successfully used for the analysis of ETN. Described methods allow fast, versatile, and reliable detection or analysis of samples containing erythritol tetranitrate in forensic laboratories.  相似文献   

18.
Although the diamond anvil cell (DAC) has been used in many forensic science laboratories for the analysis of trace evidence, few applications of this technique for the analysis of controlled substances have been reported. This may be due to both an unfamiliarity on the part of forensic drug chemists with this accessory and the nature and quality of spectra that result from use of a DAC on a dispersive instrument. Along with low energy throughput, which results in relatively high noise levels, strong broad diamond absorptions occur. With the use of a Fourier transform infrared instrument, these do not present a problem and nanogram quantities of materials can be analyzed when the DAC is used with an infrared microscope. Since single crystals can be sampled with the DAC, simple physical separations (involving particle-picking) can be used in certain cases to isolate drugs from particulate mixtures for infrared analysis. This method is especially useful for some "difficult" mixtures and residues, and several examples of such analyses involving samples of forensic science interest are presented.  相似文献   

19.
Fourier transform Raman and infrared spectra of pure cis(Z)- and trans(E)-2,5-dimethoxy-4,beta-dimethyl-beta-nitrostyrene (precursors of the psychotomimetic street drug STP or DOM) were recorded in the solid state. The spectra show characteristic features of the ethylene moiety and of the aryl and nitro substituents which permit ready differentiation and identification of these isomers. A very strong Raman line at 1670 cm-1 from the cis isomer for the C=C stretching mode, in comparison with a strong Raman line at 1641 cm-1 for the trans isomer, affords primary differentiation of these substances. A second characteristic, of both the Raman and infrared (IR) spectra, is that the frequency of the strong symmetric nitro (NO2) stretching band is about 40 cm-1 higher in the cis (1346 cm-1) than the trans isomer (1301 cm-1). All major IR and Raman bands are reported and given vibrational assignments.  相似文献   

20.
《Science & justice》2022,62(1):60-75
Cocaine is one of the most widely used illicit drugs worldwide. Cocaine powders seized by the Police may contain numerous other substances besides the drug itself. These can be impurities originating from the coca plant or the production process, or be purposely added to the drug formulation as adulterants and cutting agents. In forensic laboratories, identification of cocaine is routinely done through GC-MS analysis, but other components are often ignored even if the method allows for their detection. Yet, they can provide valuable insight into the history of a seizure and its potential connection to other samples. To explore this idea, an extensive review of common impurities and adulterants encountered in cocaine is presented. Based on their incidence, concentration in the end product and compatibility with GC-MS methods, their overall usefulness as candidates for the statistical investigation of existing forensic data is evaluated. The impurities cis- and trans-cinnamoylcocaine, tropacocaine, norcocaine and N-benzoylnormethylecgonine as well as the adulterants lidocaine, procaine, tetracaine, benzocaine, caffeine, acetylsalicylic acid, phenacetin, ibuprofen, levamisole, hydroxyzine and diltiazem are promising candidates to provide additional forensic intelligence. Future research on optimized routine GC-MS methods, signal reproducibility, comparison, statistics and databases is suggested to facilitate this concept. Ultimately, such an approach may significantly advance the amount of information that is extracted from routine casework data, elucidate developments in the cocaine markets in the past and facilitate Police work in the future. Preliminary assessment of existing data from the forensic laboratory of the Amsterdam Police has been included to show that the detection of the identified target impurities is feasible, and that small adjustments to the analysis method could significantly increase the detectability of these analytes in prospective drug screenings. Forensic intelligence based on retrospective data mining of cocaine containing casework samples may thus be realized with minimal additional laboratory efforts by using already available instrumentation, samples and data.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号