首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This study investigated and evaluated the safety margins of the continuous long duration (up to 30 min) effect of the TASER X26 waveform, using a Sus scrofa model. Long duration continuous stimulus has not been evaluated on humans or human surrogates prior to this study. Swine were used as models due to similarities with humans in their skin and cardiovascular systems. Very long duration was used to determine both exposure dose and possible adverse physiological effects of dose. The trial began with an application of 10 min, and subsequent animals received increasing exposure time up to a survived maximum duration of 30 min. At the onset of this work, it was hypothesized that there would be a time limit after which most animals would not survive consistent with increased dose response. However, this hypothesis was not supported by the experimental results. All animals (10 of 10) survived up to 3 min. Seven of the 10 animals survived up to a 10‐min exposure and 3 of 5 animals with a 30‐min target exposure survived the full exposure. Surviving animals were recovered and observed for 24 h, with no postrecovery deaths. This suggests that swine (based on physiology) will not experience a fatal event when exposed to the TASER X26 for a continuous 3 min. Conclusions regarding longer duration (10–30 min) are not as certain due to the small sample sizes at these time intervals.  相似文献   

2.
The abundance of, and reliance upon, human electro‐muscular incapacitation (HEMI) devices, especially in law enforcement, has generated scrutiny and examination of these technologies. The purpose of this study was to examine cardiovascular effects resulting from typical (5 sec) and longer activation (20 sec) HEMI applications studying myocardial function and peripheral vascular system using a combination of invasive cardiovascular catheters and transesophageal echocardiography (TEE). Six healthy swine (Sus scrofa) 3–5 months in age and weighing between 60 and 86 kg were anesthetized and exposed to the TASER Model X26 waveform while transesophageal echocardiography was performed. Stroke volume was shown to statistically decrease during HEMI application indicating an increase in systemic vascular resistance, but HEMI application did not result in myocardial dysfunction (“cardiac stunning”).  相似文献   

3.
IntroductionLaw enforcement officers use conducted electrical weapons (CEW) such as the TASER X26® to control violently resistive subjects. There are no studies in the medical literature examining the effects of these weapons on the human stress response. This is the first study to compare the human stress response to conducted electrical weapons, oleoresin capsicum (O.C.), a cold-water tank immersion, and a defensive tactics drill.MethodsSubjects were randomized to one of the four interventions studied. Subjects received either a 5-s exposure from the TASER X26 CEW with the probes fired into the back from 7 ft, a 5-s spray of O.C., a skin and mucous membrane irritant, to the eyes, a 45-s exposure of the hand and forearm in a 0 °C cold water tank, or a 1-min defensive tactics drill.ResultsAlpha-amylase had the greatest increase from baseline at 10–15 min with the defensive tactics drill. Cortisol had the greatest increase at 15–20 min with O.C. Cortisol remained most elevated at 40–60 min in the defensive tactics drill group.ConclusionsOur preliminary data suggests that physical exertion during custodial arrest may be most activating of the human stress response, particularly the sympathetic–adrenal–medulla axis. This may suggest that techniques to limit the duration of this exertion may be the safest means to apprehend subjects, particularly those at high-risk for in-custody death. Conducted electrical weapons were not more activating of the human stress response than other uses of force.  相似文献   

4.
Electronic control devices (ECDs) may eventually be deployed by the military in a manner resulting in longer exposures than those encountered during law-enforcement operations. In a previous study, 18 repeated cycling (5-second on/5-second off) exposures (within a 3-minute period) of anesthetized swine to an ECD (TASER International's Advanced TASER X26 device) resulted in leg muscle contraction, acidosis, and increases in blood electrolytes. In the current study, experiments were performed to examine effects of exposures to a different cycling rate (7-second on/3-second off), from a modified X26 ECD, on 10 swine (Sus scrofa), maintained on propofol anesthesia. In contrast with the previous study, a large number of animals (6/10) died immediately after the exposures. There were no major differences in pre-exposure blood factors from survivors versus nonsurvivors, with the exception of hematocrit and 2 isoenzymes of lactate dehydrogenase. It is doubtful that these factors would be useful in predicting survival after ECD exposure. Blood pH was significantly decreased after exposure, but (in animals that survived) subsequently returned to baseline levels. On the basis of the overall survival rate, further development of useful ECDs (for long-term incapacitation during military operations) may require consideration of longer pauses between repeated exposures over a 3-minute period.  相似文献   

5.
Conducted energy weapons (CEWs) (including the Advanced TASER® X26 model produced by TASER International, Inc.) incapacitate individuals by causing muscle contractions. In this study using anesthetized swine, the potential incapacitating effect of primarily monophasic, 19‐Hz voltage imposed by the commercial CEW was compared with the effect of voltages imposed by a laboratory device that created 40‐Hz square waves. Forces of muscle contraction were measured with the use of strain gauges. Stimulation with 40‐Hz square waves required less pulse energy than stimulation with the commercial CEW to produce similar muscle contraction. The square‐pulse stimulation, at the higher repetition rate, caused a more complete tetanus at a lower energy. Use of such a simple shape of waveform may be used to make future nonlethal weapon devices more efficient.  相似文献   

6.
TASER® weapons are conducted energy weapons (CEWs) that are frequently used by police departments around the world. CEWs can be deployed in two methods: drive stun application and probe deployment. This study aims to examine damages caused by TASER devices on fabrics and whether types of fabric material and TASER models could contribute to different damage features. Three types of white fabric were used, including 100% cotton, 100% polyester, and 65:35 polyester-cotton blend. Three models: TASER X26P, TASER X2, and TASER 7 were shot onto each type of fabric, with five repetitions each. Each damaged area on the fabric caused by a probe is a sample (n = 90) and was examined with a Keyence digital microscope. Images were captured by the Keyence microscope and measurements were recorded, including damage dimensions, fabric condition, evidence of burning, and extra findings. The presence of fused yarn ends was found to be statistically significant across the fabric types, and no damage features were found that may assist in the identification of TASER models. Other damage features including damage dimensions, discoloration, and fiber deformation were not found to be showing apparent differences according to statistical analysis. The conclusions made by this research should be used with caution due to the small sample size.  相似文献   

7.
Estimating age‐at‐death of individuals represented only by skeletonized human remains is a fundamental aspect of forensic anthropological casework. Recently, several researchers have proposed that bone mineral density (BMD) is a useful predictor of age‐at‐death in forensic contexts. Navega et al. (JFS 63(2):497–503) developed an online application called DXAGE for calculating age‐at‐death from BMD parameters. This study tests the utility of DXAGE by utilizing data from the National Health and Nutrition Examination Survey (NHANES). BMD data from a female subsample (n = 470) of the NHANES 2007–2008 dataset were analyzed, and the relationship between predicted age and real age was examined. Inaccuracy was 14.25 years, and bias was ?7.20 years. Results show that there is a weak correlation between predicted and actual age (r = 0.47) using the DXAGE application. While BMD data are potentially useful for predicting age age‐at‐death, the DXAGE application should be used cautiously in forensic anthropological contexts.  相似文献   

8.
Abstract: Electronic control devices (including the Advanced TASER® X26 model produced by TASER International) incapacitate individuals by causing muscle contractions. To provide information relevant to development of future potential devices, effects of monophasic square waves with different parameters were compared with those of the X26 electronic control device, using two animal models (frogs and swine). Pulse power, electrical pulse charge, pulse duration, and pulse repetition frequency affected muscle contraction. There was no difference in the charge required, between the square waveform and the X26 waveform, to cause approximately the same muscle‐contraction response (in terms of the strength‐duration curve). Thus, on the basis of these initial studies, the detailed shape of a waveform may not be important in terms of generating electro‐muscular incapacitation. More detailed studies, however, may be required to thoroughly test all potential waveforms to be considered for future use in ECDs.  相似文献   

9.
“Bullet wipe” is the material deposited by a bullet on any surface with which it comes into contact after it is fired and may contain debris from the gun barrel, including particles of primer and metal fragments from previously fired bullets. X‐ray analysis is a non‐destructive method by which traces of metallic elements can be visually detected. The analysis of osseous defects for radiodense bullet wipe (RBW) assists in determining the presence or absence of perforating gunshot wounds, especially in fragmented, skeletonized remains. The aim of our current study was to determine the frequency of RBW around entrance firearms injuries that perforated bone. We prospectively analyzed entrance gunshot wounds for RBW over a three‐year period using digital X‐ray analysis (n = 59). We retrospectively reviewed the corresponding autopsy reports to determine the frequency of RBW by biologic sex, reported ancestry, age‐at‐death, location of wound, manner of death, range of fire, bullet caliber, and presence of bullet jacket. Data were analyzed by Fisher's exact test or Chi‐square test with significance levels accepted at p < 0.05. RBW was present in 66% (n = 39) of examined cases. Decedent characteristics did not significantly alter RBW distribution, including biologic sex (p = 0.75), reported ancestry (p = 0.49), and age‐at‐death (p = 0.43). Additionally, the location of the osseous entrance gunshot wound, manner of death, range of fire, and cartridge caliber did not affect RBW detection. All cases involving non‐jacketed rounds (n = 5) showed RBW (p = 0.30). To our knowledge, this study is the first to report the frequency of RBW detection from osseous entrance gunshot wounds.  相似文献   

10.
In a previous study, 18 repeated exposures of anaesthetized swine to an electro-muscular incapacitating device (TASER International's ADVANCED TASER X26 electronic control device) resulted in acidosis and increases in blood electrolytes. In the current study, experiments were performed to investigate effects of a more typical scenario of repeated exposures of the device on muscle contraction and changes in blood factors. Ten swine were exposed for 5s, followed by a 5-s period of no exposure, three times. Selected blood factors were monitored for 3h following exposure. Transient increases in blood glucose, lactate, sodium, potassium, calcium, and pCO(2) were consistent with previous reports in the literature dealing with studies of muscle stimulation or exercise. Blood pH was decreased immediately following exposure, but subsequently returned toward a normal level. Oxygen saturation (measured by pulse oximetry) was not changed significantly. In conclusion, three repeated TASER device exposures had only transient effects on blood factors, which all returned to pre-exposure levels, with the exception of hematocrit (which remained elevated after 3h). Since the increase in this factor was less than that which may occur after short periods of exercise, it is unlikely that this would be an indicator of any serious harm.  相似文献   

11.
Suchey–Brooks method has been studied many times with varying reports of accuracy and reliability. A systematic review and meta-analyses were utilized to quantitatively determine the accuracy and reliability of the Suchey–Brooks (S-B) method. A systematic search of PubMed and EBSCO health and medical databases was performed. Meta-analyses were performed to quantify the relationship between actual known age at death and the S-B method using Spearman's Rho and Pearson's r for (1) combined males and females estimates, (2) male-only estimates, and (3) female-only estimates. Overall correlation coefficient using Cohen's kappa, Spearman's Rho, and Pearson's r was also calculated to determine the interrater and intrarater reliability using the S-B method. Eighteen studies classified as moderate-to-high methodological quality met the inclusion criteria. The sample sizes were different for the combined male and female (n = 2620), male-only (n = 2602), and female-only (n = 1431) meta-analyses. The effect size of the age at death meta-analyses was large and significant for combined males and females (Spearman's Rho = 0.62; Pearson's r = 0.65), male-only (Spearman's Rho = 0.77; Pearson's r = 0.75), and female-only (Spearman's Rho = 0.71; Pearson's r = 0.71). The overall correlation coefficients of the interrater (Kappa = 0.76; Spearman's Rho = 0.73; Pearson's r = 0.80) and intrarater (Kappa = 0.81; Spearman's Rho = 0.91; Pearson's r = 0.83) reliability meta-analyses were large and significant. A significant degree of heterogeneity was present in all meta-analyses, with minimal evidence of publication bias. The meta-analyses results suggest the S-B method is highly reliable with a moderate-to-high degree of accuracy. Our results also identified sample size and accuracy differences between male and female individuals.  相似文献   

12.
A series of experiments were performed to evaluate and document the effect of a TASER (“stun gun”) on triacetone triperoxide (TATP), an easily manufactured explosive used often in IEDs and suicide bombing vests. TATP samples were synthesized and subjected to several tests of their sensitivity. These samples were run through a BAM Friction test with a result of <0.5 N, Impact Test with a result of 5.8 ± 0.4 cm, and Electrostatic Discharge test with a result of 0.073 ± 0.018 J. In addition, TATP was shocked with a TASER in a variety of configurations. The TATP reacted in 17/17 tests when the TASER arced through the TATP and 0/4 times when the TATP was configured in such a way that the TATP was not subjected to the electrical arc. Based on the experimental data, TATP will readily explode in a variety of configurations by a TASER or similar device. Testing should be expanded, as the data presented here are limited to a single formulation of TATP. Just one of a large array of TASER‐like devices by a single manufacturer were tested; other devices, scenarios and formulations of TATP and other likely threat materials should be assessed.  相似文献   

13.
This study examined associations between criminal recidivism after discharge from forensic treatment and variables related to either the time before the current forensic treatment, or the current forensic treatment, or the follow-up after discharge. Participants were treated in 12 forensic clinics according to section 63 of the German penal code. A patient was classified as a criminal recidivist when the patient or the aftercare reported that the patient was delinquent at follow-up. Patients without criminal recidivism were patients for which both perspectives (patient and aftercare) reported no delinquency at follow-up. Mann–Whitney U-tests and Fisher's exact tests were performed. Data to classify patients were available for N = 249 patients. Fifteen patients (6%) were classified as criminal recidivists. The follow-up was M = 12.58 (SD = 1.84) months, and the criminal acts occurred M = 6.00 (SD = 5.55) months after discharge. Differences between patients with and without criminal recidivism were found in pretreatment (young age at first crime, early onset of mental disorder, previous forensic treatments), treatment-related (disorder due to psychoactive substance use, gradual release abuses, outbreaks, assaults against staff, criminal act during treatment, type of discharge, outcome ratings), as well as follow-up variables (no specified housing situation, not being abstinent from psychoactive substances, inpatient readmission, course of outpatient treatment, course of mental disorder) (all < 0.05). To conclude, it is important to consider variables related to the time before the current treatment, treatment-related variables, and variables related to the follow-up to identify the patients at risk of criminal recidivism after discharge from forensic treatment.  相似文献   

14.
There is only a small amount of experimental data about whether the TASER X26, a nonlethal weapon that delivers a series of brief electrical pulses to cause involuntary muscular contraction to temporarily incapacitate an individual, can initiate ventricular fibrillation to cause sudden cardiac arrest either immediately or sometime after its use. Therefore, this paper uses the fundamental law of electrostimulation and experimental data from the literature to estimate the likelihood of such events. Because of the short duration of the TASER pulses, the large duration of the cardiac cell membrane time constant, the small fraction of current from electrodes on the body surface that passes through the heart, and the resultant high pacing threshold from the body surface, the fundamental law of electrostimulation predicts that the TASER pulses will not stimulate an ectopic beat in the large majority of normal adults. Since the immediate initiation of ventricular fibrillation in a normal heart requires a very premature stimulated ectopic beat and the threshold for such premature beats is higher than less premature beats, it is unlikely that TASER pulses can immediately initiate ventricular fibrillation in such individuals through the direct effect of the electric field generated through the heart by the TASER. In the absence of preexisting heart disease, the delayed development of ventricular fibrillation requires the electrical stimuli to cause electroporation or myocardial necrosis. However, the electrical thresholds for electroporation and necrosis are many times higher than that required to stimulate an ectopic beat. Therefore, it is highly unlikely that the TASER X26 can cause ventricular fibrillation minutes to hours after its use through direct cardiac effects of the electric field generated by the TASER.  相似文献   

15.

Objectives

Despite its widespread adoption by more than two-thirds of police departments in the US, there has not been a single study examining the effects of the TASER on cognitive functioning. This inquiry is important for two reasons. First, research has consistently documented cognitive deficits following exposure to electricity (the TASER is an electrical device). Second, questions have emerged regarding whether TASER exposure impairs suspects’ ability to understand and waive their Miranda rights.

Methods

To explore this issue, the authors carried out a pilot study with 21 police recruits who received a TASER exposure as part of their training at the San Bernardino County (CA) Training Center. Each recruit was given a battery of cognitive tests 3–4 h before TASER exposure, within 5 min after exposure, and again 24 h after exposure.

Results

Recruits experienced statistically significant reductions in several measures of cognitive functioning following TASER exposure. However, all recruits had returned to their baseline levels of functioning within 24 h. Learning effects were documented in several of the cognitive tests.

Conclusions

The questions driving this study involve serious issues including constitutionally protected rights of the accused, use of force by police, and previously unexamined effects of the TASER on the human body. The pilot study represents a critical first step in exploring the effects of the TASER on cognitive functioning. Moreover, the results provided the authors with important information that will guide their larger study, a randomized controlled trial where healthy human volunteers will be randomly assigned to four groups, two of which receive a TASER exposure.  相似文献   

16.
Repeated exposure to electro-muscular incapacitating devices could result in repetitive, sustained muscle contraction, with little or no muscle recovery period. Therefore, rhabdomyolysis and other physiological responses, including acidosis, hyperkalaemia, and altered levels of muscle enzymes in the blood, would be likely to occur. Experiments were performed to investigate effects of repeated exposures of TASER International's Advanced TASER X26 on muscle contraction and resultant changes in blood factors in an anaesthetized swine model. A total of 10 animals were used. Six swine were exposed for 5 s, followed by a 5-s period of no exposure, repeatedly for 3 min. (In five of the animals, after a 1-h delay, a second 3-min exposure period was added.) The remaining four animals were used for an additional pilot study. All four limbs of each animal exhibited contraction even though the electrodes were positioned in areas at some distances from the limbs. The degree of muscle contraction generated during the second exposure period was significantly lower than that in the first exposure series. This finding was consistent with previous studies showing that prolonged activity in skeletal muscle will eventually result in a decline of force production. There were some similarities in blood sample changes in the current experiments with previous studies of muscular exercise. Thus problems concerning biological effects of repeated TASER exposures may be related, not directly to the "electric output" per se, but rather to the resulting contraction of muscles (and related interruption of respiration) and subsequent sequelae. Transient increases in hematocrit, potassium, and sodium were consistent with previous reports in the literature dealing with studies of muscle stimulation or exercise. It is doubtful that these short-term elevations would have any serious health consequences in a healthy individual. Blood pH was significantly decreased for 1h following exposure, but subsequently returned toward a normal level. Leg muscle contractions and decreases in respiration each appeared to contribute to the acidosis. Lactate was highly elevated, with a slow return (time course greater than 1 h) to baseline. Other investigators have reported profound metabolic acidosis during restraint-associated cardiac arrest. Since restraint often occurs immediately after TASER exposure, this issue should be considered in further development of deployment concepts. On the basis of the results of the current studies, the repeated use of electro-muscular incapacitating devices in a short period of time is, at least, feasible, with the caveat that some medical monitoring of subjects may be required (to observe factors such as lactate and acidosis).  相似文献   

17.
Minimum postmortem interval (mPMI) can be estimated with preceding mean ambient temperature models that predict carrion taxon pre‐appearance interval. But accuracy has not been compared with using summary statistics (mean ± SD of taxon arrival/departure day, range, 95% CI). This study collected succession data from ten experimental and five control (infrequently sampled) pig carcasses over two summers (n = 2 experimental, n = 1 control per placement date). Linear and exponential preceding mean ambient temperature models for appearance and departure times were constructed for 17 taxa/developmental stages. There was minimal difference in linear or exponential model success, although arrival models were more often significant: 65% of linear arrival (r2 = 0.09–0.79) and exponential arrival models (r2 = 0.05–81.0) were significant, and 35% of linear departure (r2 = 0.0–0.71) and exponential departure models (r2 = 0.0–0.72) were significant. Performance of models and summary statistics for estimating mPMI was compared in two forensic cases. Only summary statistics produced accurate mPMI estimates.  相似文献   

18.
The effects of dose–death interval on the detection of acute fentanyl exposure in fresh and decomposed skeletal tissues (marrow and bone), by automated enzyme-linked immunosorbent assay (ELISA) are described. Rats (n = 14) were administered fentanyl acutely at a dose of 0 (n = 2) or 60 μg/kg (n = 12) by intraperitoneal injection, and euthanized within 20, 45, 135, or 225 min. Femora and tibiae were extracted from the fresh corpses and marrow was isolated from the femoral and tibial medullary cavities. The remains were then allowed to decompose outdoors to the point of complete skeletonization, and vertebrae, pelvi and miscellaneous (humeri and scapulae) were recovered for analysis. In all cases, bones were cleaned in alkaline solution and then ground into a fine powder. Marrow was homogenized in alkaline solution. Fentanyl was extracted from ground bone by methanolic extraction. Extracts were adjusted to pH 6 and analyzed by ELISA. Perimortem heart blood was also collected and diluted in phosphate buffer prior to screening by ELISA. The effect of tissue type on ELISA response was examined through determination of binary classification test sensitivity and the relative decrease in absorbance (%DA, drug-positive tissues vs. drug-free controls) in each tissue type. Overall, the %DA varied significantly between extracts from different skeletal tissues at a given dose–death interval, according to the general order of marrow > decomposed bone > fresh bone. Binary classification test sensitivity values for fentanyl in marrow, fresh epiphyseal (femoral and tibial) bone, fresh diaphyseal (femoral and tibial) bone, decomposed vertebrae, decomposed pelvic bone, and decomposed miscellaneous bone were 67–100%, 0–33%, 0–33%, 0–67%, 0–67% and 0–33%, respectively, over all dose–death intervals. Although group mean %DA values showed a strong negative correlation with dose–death interval in marrow, fresh epiphyseal bone, decomposed vertebrae, pelvic and miscellaneous bone (r = ?0.989, ?0.930, ?0.955, ?0.903, and ?0.974, respectively), the high variability in both fresh and decomposed bone precluded differentiation of the dose–death intervals based on %DA value alone. Overall, the results suggested that the type of skeletal tissue sampled may not be as important as the amount of residual marrow remaining in skeletonized remains.  相似文献   

19.
The identification of hypothermia as cause of the death was always quite problematic in the field of forensic medicine. The aim of the present study was to verify the determination of calcium content in post-mortem liver, heart, and skeletal muscle samples as the biochemical marker defining hypothermia as the cause of death. The study involved 43 autopsy cases in which the circumstances of death indicated the effects of overcooling. The control group consisted of material collected from the corpses of 30 persons who were not exposed to low temperatures but died due to technical injuries (n = 5), asphyxia (n = 6), intoxication with ethanol and other substances (n = 8), and acute myocardial infarction/ischemia (n = 11). The concentration of calcium in autopsy samples was determined applying flame atomic absorption spectroscopy. Our study showed no significant differences of calcium content in tissues of persons who died due to hypothermia, over those who died in normothermic conditions.  相似文献   

20.
Concern has been raised over the infection risk of the TASER electrical weapon since the probes penetrate the skin. The manufacturing process produces unsterilized probes with a 5% rate of Staphylococcus aureus contamination. Voluntary recipients (n = 208) of probe exposures were surveyed and there were no self‐observations of infection. With over 3.3 million probe landings, there have been 10 case reports of penetrations of sensitive tissue with no reported infections. The electrical field was modeled and found that the electrical pulses generate a field of over 1200 V/mm on the dart portion. This is sufficient to sterilize the dart via electroporation. Electrical weapon probes appear to have a very low (possibly zero) rate of infection. The factors leading to this low infection rate appear to be a manufacturing process producing a low rate of bacterial contamination and the pulses sterilizing the dart via electroporation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号