首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
《Science & justice》2014,54(1):3-21
An LTQ-Orbitrap FTMS is a new (hybrid) mass spectrometric (MS) analyzer. It allows for the acquisition of full scan MSn (n-stage fragmentations, n = 1  n) spectra with the linear ion trap detector (LTQ) at high speed and/or with the Fourier Transform-detector (Orbitrap) with ultra high mass resolution (> 60,000 at m/z < 400 amu) and high mass accuracy (≤ 1 ppm with internal calibration). In addition it may be coupled with liquid chromatography (LC) with photo diode array (PDA) detection.Two methods for the forensic screening and confirmation of all common trace explosives in post-blast residues have been developed on this instrument using atmospheric pressure chemical ionization (APCI). In one run, the nitrogen-containing explosives are analyzed with the combination of “LC-(PDA)-APCI(−)-LTQ MS2/Orbitrap FTMS” (Method 1). In another run, peroxide explosives are analyzed with “LC-APCI(+)-LTQ MS2/Orbitrap FTMS” (Method 2).The performance of both methods has been validated according to procedures defined in the EU COMMISSION DECISION implementing Council Directive 96/23/EC concerning the performance of analytical methods and the interpretation of results (DC 2002/657/EC) and other standards (NEN 17025 and NEN 7777). The methods are highly selective due to the simultaneous utilization of the Orbitrap FTMS and LTQ MS2, both of which are highly selective detectors Tested explosive compounds can be detected in the molecular ion form by the Orbitrap analyzer with minimal mass interference in different matrices when using an extremely narrow mass tolerance detection window (≤ 2 ppm). The identification of a detected compound follows an identification point system. Experimental results show that almost all explosive compounds meet the confirmation criteria (minimum 4 points) required for the positive identification by the DC 2002/657/EC.  相似文献   

2.
《Science & justice》2014,54(2):141-145
The implications of the recent recommendations of the Law Commission regarding the use of admissibility tests have the potential to be far reaching for forensic disciplines that rely on the expertise of highly qualified expert witnesses. These disciplines will need a concomitant body of peer-reviewed experiments that provides a basis for the interpretations of such evidence presented in court. This paper therefore, presents such results from two experiments which were undertaken to address specific issues that were raised in cases presented in the British courtroom. These studies demonstrate that there is a variability in the persistence of Lily, Daffodil and Tulip pollen when exposed to high temperatures between 0.5 min and 1440 min (24 h). It was possible to identify all three pollen types after 30 min of exposure to 400 °C, and after shorter time frames the threshold for successful identification was 700 °C after 0.5 min for all pollen types tested and 500 °C for Daffodil and Lily after 5 min of heat exposure. Over longer time periods (18 h (1080 min)) the different pollen types were found to persist in a viable form for identification at 300 °C (Lily), 200 °C (Daffodil) and 50 °C (Tulip). These findings, albeit from a small sample of pollen types, provide empirical contextual information that would contribute to such evidence having sufficient scientific weight to meet admissibility criteria and be viable evidence for a court. These studies demonstrate the value in seeking pollen evidence from even such extreme crime scenes as encountered in vehicular fires.  相似文献   

3.
A novel application of visible wavelength hyperspectral image analysis has been applied to determine the age of blood stains up to 30 days old. Reflectance spectra from selected locations within the hyperspectral image, obtained from a portable instrument, were subjected to spectral pre-processing. This was followed by the application of a linear discriminant classification model, making estimations possible with an average error of ± 0.27 days for the first 7 days and an overall average error of ± 1.17 days up to 30 days. This is also the first reported study of the determination of the age of fresh blood stains (less than one day old) with an error of ± 0.09 h. The studies have been made under controlled conditions and represent, at this stage, proof of concept results but also are the most accurate age estimation results for measurements between 0 and 30 days reported to date. The results are consistent with well-established kinetic processes suggesting that the pre-processing stages described are revealing spectroscopic changes which are reliably following the time dependent oxidation of HbO2. The potential for parameterisation of environmental factors to make the method generally applicable at crime scenes is discussed, along with the developments required to further improve classification and to make the instrument genuinely portable.  相似文献   

4.
Although poaching is a common wildlife crime, the high and prohibitive cost of specialised animal testing means that many cases are left un-investigated. We previously described a novel approach to wildlife crime investigation that looked at the identification of human DNA on poached animal remains (Tobe, Govan and Welch, 2011). Human DNA was successfully isolated and amplified from simulated poaching incidents, however a low template protocol was required which made this method unsuitable for use in many laboratories. We now report on an optimised recovery and amplification protocol which removes the need for low template analysis.Samples from 10 deer (40 samples total — one from each leg) analysed in the original study were re-analysed in the current study with an additional 11 deer samples. Four samples analysed using Chelex did not show any results and a new method was devised whereby the available DNA was concentrated. By combining the DNA extracts from all tapings of the same deer remains followed by concentration, the recovered quantity of human DNA was found to be 29.5 pg ± 43.2 pg, 31 × greater than the previous study. The use of the Investigator Decaplex SE (QIAGEN) STR kit provided better results in the form of more complete profiles than did the AmpF?STR® SGM Plus® kit at 30 cycles (Applied Biosystems). Re-analysis of the samples from the initial study using the new, optimised protocol resulted in an average increase of 18% of recovered alleles. Over 17 samples, 71% of the samples analysed using the optimised protocol showed sufficient amplification for comparison to a reference profile and gave match probabilities ranging from 7.7690 × 10? 05 to 2.2706 × 10? 14.The removal of low template analysis means this optimised method provides evidence of high probative value and is suitable for immediate use in forensic laboratories. All methods and techniques used are standard and are compatible with current SOPs. As no high cost non-human DNA analysis is required the overall process is no more expensive than the investigation of other volume crime samples. The technique is suitable for immediate use in poaching incidents.  相似文献   

5.
Allele frequency distributions for 24 short tandem repeat (STR) loci were determined using the PowerPlexR Fusion System (Promega) in 407 Japanese samples. The most informative locus among the 22 STR loci, excluding Amelogenin and DYS391, was Penta E (power of discrimination (PD) = 0.98), while the least informative was TPOX(PD = 0.831). The 22 loci combined matching probability (MP) was calculated to be 4.13 × 10−26. These parameters indicated the usefulness of this 24 STR analysis in forensic personal identification and parentage testing among Japanese population.  相似文献   

6.
7.
A continual challenge in the field of forensic DNA analysis is the amplification and interpretation of degraded and low-copy number (LCN) DNA obtained from amounts of limited biological evidence. It has been well established that DNA profiles obtained from the amplification of low quality, degraded, and/or LCN DNA samples are often of limited value due to the frequent occurrence of preferential amplification during polymerase chain reaction (PCR). The by-products of preferential PCR amplification are often observed as inter- and intra-locus peak imbalance, allelic dropout, and/or locus dropout. These are all artifacts that are identified during the interpretation phase of analysis rather than by improving the quality of the DNA present. While it is theoretically possible to obtain a complete DNA profile from a single cell, in reality, profiles obtained from suboptimal amounts of DNA are difficult to interpret and frequently inconsistent when replicated. Inspired by advances in next-generation sequencing techniques, we propose a methodology for simultaneously normalizing the abundance of PCR products across all short tandem repeat (STR) loci using the DNA exonuclease, duplex-specific nuclease (DSN). DSN is an enzyme isolated from the hepatopancreas of Red King (Kamchatka) crab that possesses a strong affinity for digesting double stranded DNA (dsDNA) and has limited activity toward single stranded DNA (ssDNA). Degraded DNA known to display peak imbalance and allele dropout was amplified using AmpFlSTR® Identifiler® Plus for 28 cycles. Following amplification, samples were denatured at 99.9 °C for 5 min and incubated with one unit of DSN at 62 °C in a 28 μl volume for 1 min. Nuclease activity was terminated through the addition of equal volume of 10 mM EDTA and 95 °C incubation for 2 min. Following DSN treatment, 21 of 30 alleles within the known profile exhibited some improvement in peak height balance. The findings obtained support the potential use of DSN treatment as a method for normalizing STR profiles and improving the quality of data from degraded and low quantity DNA samples.  相似文献   

8.
Age estimation of an individual whether living or dead is an intimidating task in forensic investigations. Since teeth are more resistant to most peri- and post-mortem changes, they are frequently used for identification and age estimation when skeletal remains are in poor condition. However, most methods are destructive and warrant extraction of teeth which is not feasible in living individuals. Cameriere's et al. put forth a radiographic method of age estimation by pulp to tooth area ratio (AR) in canines and revealed a linear regression between age and the AR. In the present study, we estimated the AR in 456 canines (upper, lower and both) in an Indian sample (114 males and 114 females) using radiovisiography technique. Linear regression equations were derived for upper canine, lower canine and both using the AR to estimate chronological age. Additionally, the efficacy of these equations was also evaluated in younger age group (<45 years). The formulas derived, i.e., age = 96.795 ? 513.561x1 (Eq. (1)) for upper canine, age = 88.308 ? 458.137x2 (Eq. (2)) for lower canine and age = 99.190 ? 283.537x1 ? 306.902x2 + 400.873x1x2 (Eq. (3)) for both the canines were applied to predict the chronological age. The mean value of residuals using these regression equations ranged from 4.28 to 6.39 years with upper canine equation generally giving a precise result. When these equations were applied for younger ages (<45 years), the regression equation derived from both canines gave a better result (mean residual 2.70 years). Overall these equations were better able to predict the age in younger ages, i.e., up to 45 years.  相似文献   

9.
In post-mortem work, blood is a potential source of external contamination of hair. The present study was carried out to investigate the amount of drug absorbed into hair which has been contaminated with blood containing either cocaine or BE. Solutions were prepared containing 0.05, 0.1, 0.2, 0.5 and 3.0 μg/mL of either cocaine or BE in human blood. Samples of approximately 3.2 g of drug-free hair were contaminated by soaking in the blood solutions for 5 min. They were then removed and left at room temperature. Approximately 0.5 g of hair was collected from each of the blood soaked hair samples at 6 h, 1, 2, 4 and 7 days after contamination. As each hair sample was collected it was shampoo-washed to prevent further drug absorption. Hair samples were analysed in triplicate using a fully validated method described previously. EME and cocaethylene were also measured in order to find out if cocaine or BE was breaking down to these compounds. Both cocaine and BE were absorbed into hair in significant concentrations when the concentration in the blood was 0.5 μg/mL or greater; cocaine was more readily absorbed than BE. Cocaine broke down to EME (<LOQ) at 0.5 μg/mL and to EME (>LOQ) and BE (<LOQ) at 3.0 μg/mL. When the blood concentration of cocaine was 0.5 μg/mL or less, there was no evidence of it breaking down to form BE. From the samples soaked in blood containing BE, there was no evidence of the BE breaking down. The absorption of drug into hair did not increase as the contamination period increased from 6 h to 7 days.  相似文献   

10.
Recently, different portable hand-held and battery-powered dental X-ray units have become available. Especially for forensic odontological purposes, they offer diverse advantages such as for use in disaster areas and crime-scene locations as also in autopsy rooms and mortuaries. For any application, the most important feature of these hand-held devices is the delivered image quality. The aim of this study is to evaluate the radiographic image quality acquired by two portable X-ray devices in combination with two types of image receptors and to compare the findings with the image quality of a standard intra-oral X-ray device.Eleven samples consisting of eight teeth, two dry skeletal specimens and one formalin-fixed mandible part were mounted on blocks for standardised (re)positioning. Radiological images were acquired with two hand-held (AnyRay® 60 kVp, 0.02–4.00 mAs and NOMAD® 60 kVp, 0.023–2.277 mAs) and one wall-mounted (MinRay® 60/70 kVp 0.14–22.4 mAs) X-ray device combined with two image receptor systems (VistaScan® phosphor storage plate (PSP) and SIGMA® M CMOS Active Pixel technology sensor). The effect of X-ray source-to-object distance (SOD) was checked at 20 cm in conjunction with object to image receptor distances (OIDs) of 0.8 and 2.5 cm. For each parameter setup, the exposure times were run from low till high. An expert consent statement was achieved by agreement of four expert observers selecting the optimal images based on a developed four point quality rating system. Next, a selection of the images was assembled in a set of 198 observation screens and scored by seven observers. The observation screens were designed to compare observer scores, relations between devices, receptors and OIDs and images obtained from the different devices at equal exposure levels (mAs). All results were statistically analysed.Radiological image quality was significantly higher for phosphor plate compared with the CMOS digital receptor system (p < 0.0001). Furthermore, a significantly superior image quality was obtained for OID = 0.8 than for OID = 2.5 (p = 0.039). A significant difference in image quality between the three devices was also established (p = 0.02). The present study demonstrated the feasibility of portable X-ray systems for forensic odontological applications based on rendering optimal image quality, provided an in vitro guideline of optimal parameter settings and offered a radiological image database usable in further research.  相似文献   

11.
Many scientists of varying clinical backgrounds have described the phenomenon of spermaturia in animals, adolescents as well as fertile and infertile men. Nevertheless, research for an expert opinion on a law case in the field of forensic medicine revealed a lack of valid information about the longevity of spermatozoa in post-ejaculatory urine (PEU) of fertile men.Our goal was to measure the appearance of vivid sperm in PEU while considering the factor of time in order to predict a realistic interval, in which positive sperm findings might occur. Therefore ten healthy, young men donated their sperm for fertility analysis and a urine sample prior to and after ejaculation. The time intervals between ejaculation and the first micturition were preset ranging between 30 min and maximal 11 h. Each ejaculate underwent a semen analysis. The pre- and post-ejaculatory urine samples were screened for the presence of viable and motile spermatozoa. Semen parameters were determined and related to the sperm findings in the precipitate of the urine samples. The amount, the viability and motility status of the detected spermatozoa were recorded after each preset time interval.The results showed that none of the 10 participants had sperm in their urine samples prior to ejaculation. The average sperm concentration was 50.1 ± 25.8 million/ml. After a time span of 30 min 59.5% of the first fractions of PEU samples were sperm positive, after 2 and 4 h still 70%, and after 5 h sperm were no longer detected. The last motile spermatozoa could be found after 4.5 h. It seems that remaining sperm in the urethra are washed out with the first micturition in the majority of fertile men, however, the conclusion as to whether sperm findings >5 h after ejaculation are improbable needs to be confirmed by further investigations.  相似文献   

12.
A gas chromatography–mass spectrometry (GC–MS) method was developed and validated for the simultaneous qualification and quantification of methamphetamine (MA), amphetamine (AP), 3,4-methylenedioxy-N-methylamphetamine (MDMA), 3,4-methylenedioxy-N-amphetamine (MDA), ketamine (KET) and norketamine (NKT) in fingernails. Fingernail samples (20 mg) were washed with distilled water and methanol, digested with 1.0 M sodium hydroxide at 95 °C for 30 min, and then extracted with ethyl acetate. Extract solutions were evaporated to dryness, derivatized using heptafluorobutyric anhydride (HFBA) at 60 °C for 30 min, and analyzed by GC–MS. The linear ranges were 0.1–20.0 ng/mg for AP, MDMA and NKT, 0.2–20.0 ng/mg for MA and MDA, and 0.4–20.0 ng/mg for KET, with the coefficients of determination (r2  0.9989). The intra- and inter-day precisions were within 7.1% and 10.6%, respectively. The intra- and inter-day accuracies were ?10.9% to 0.8% and ?4.3% to 4.5%, respectively. The limits of detections (LODs) and the limits of quantifications (LOQs) for each analyte were lower than 0.094 ng/mg and 0.314 ng/mg, respectively. The recoveries were in the range of 72.3–94.9%. The average fingernail growth rates of two subjects for three years and six subjects for two months were 3.12 mm/month and 3.16 mm/month, respectively. The method proved to be suitable also for the simultaneous detection and quantification of MA, MDMA, KET and their metabolites in fingernails.  相似文献   

13.
《Science & justice》2014,54(6):451-458
Textile fibres were transferred to the hands of ten living subjects and their persistence was determined after hand washing. Average number of fibres transferred was 300 ± 133 (female 288 ± 92, male 311 ± 163) per 100 cm2 hand area in the 100 experiments. However the number of fibres transferred was not gender dependent but individual dependent. The hand texture of subjects was compared with the number of fibres transferred but the relationship was not observed. The number of fibres transferred varied significantly for the 10 repeated experiments performed under the same conditions for the same subject.The subjects were then asked to wash their hands with water. One test group washed their hands with standing water, and the other with running tap water. Afterwards, the number of fibres remaining on the test subjects' hands were investigated. Migration of the fibres on the surface of the observed hands did occur but total loss of transferred fibre after hand washing did not occur. The average number of fibres remaining per 100 cm2 hand area was 14 ± 10 (range = 3–72) for hand washing with standing water, and 10 ± 12 (range = 0–79) for washing with running tap water. The results of this study show the possibility of finding fibres on the hands of a person involved in a criminal case even after hand washing before fibre collection.  相似文献   

14.
Chemical etching, which is the most sensitive method to recover obliterated serial numbers on metal surfaces, has been practised quite successfully in forensic science laboratories all over the world. A large number of etchants suitable for particular metal surfaces based on empirical studies is available in the literature. This article reviews the sensitivity and efficacy of some popular etchants for recovering obliterated marks on medium carbon steel (0.31% C with ferrite–pearlite microstructure) used in automobile parts. The experiments involved engraving these carbon steel plates with some alphanumeric characters using a computer controlled machine “Gravograph” and erasing them to several depths below the bottom of their engraving depth. Seven metallographic reagents of which most of them were copper containing compounds were chosen for etching. The erased plates were etched with every one of these etchants using swabbing method. The results have revealed that Fry’s reagent comprising cupric chloride 90 g, hydrochloric acid 120 mL and water 100 mL provided the necessary contrast and was concluded to be the most sensitive. The same reagent was recommended by earlier workers for revealing strain lines in steel surfaces. Earlier, another reagent containing 5 g copper sulphate, 60 mL water, 30 mL (conc.) ammonium hydroxide, and 60 mL (conc.) hydrochloric acid was proved to be more sensitive to restore erased marks on low carbon steel (0.1% C with ferrite–pearlite structure) [M.A.M. Zaili, R. Kuppuswamy, H. Harun, Restoration of engraved marks on steel surfaces by etching technique, Forensic Sci. Int. 171 (2007) 27–32]. Thus the sensitivity of the etching reagent on steel surfaces appeared to be dependent on the content of carbon in the steel.  相似文献   

15.
PurposeTo construct an empirically rigorous typology of multiple homicide offenders (MHOs).MethodThe current study conducted latent class analysis of the official records of 160 MHOs sampled from eight states to evaluate their criminal careers.ResultsA 3-class solution best fit the data (?2LL = ?1123.61, Bayesian Information Criterion (BIC) = 2648.15, df = 81, L2 = 1179.77). Class 1 (n = 64, class assignment probability = .999) was the low-offending group marked by little criminal record and delayed arrest onset. Class 2 (n = 51, class assignment probability = .957) was the severe group that represents the most violent and habitual criminals. Class 3 (n = 45, class assignment probability = .959) was the moderate group whose offending careers were similar to Class 2.ConclusionA sustained criminal career with involvement in versatile forms of crime was observed for two of three classes of MHOs. Linkages to extant typologies and recommendations for additional research that incorporates clinical constructs are proffered.  相似文献   

16.
This work evaluates cocaine purity and the concentration ranges of adulterants and inorganic constituents for 31 street cocaine samples seized in two different regions of Brazil from July 2008 to May 2010. Cocaine and adulterants, such as caffeine, lidocaine and benzocaine, were quantified by Gas chromatography–mass spectrometry (GC–MS), and the inorganic constituents were determined by Inductively Coupled Plasma-Optical Emission Spectrometry (ICP-OES) and ion chromatography (IC). The cocaine concentrations in the samples seized in the Amazonas state (AM samples) ranged from 154 to 978 mg g? 1, and these samples did not contain any of the adulterants studied. The cocaine concentrations in the samples seized in the Minas Gerais state (MG samples) ranged from 63.9 to 753 mg g? 1. Caffeine was the main adulterant found in 76% of the MG samples, ranging in concentration from 5.5 to 645.3 mg g? 1. Lidocaine was found in 66.7% of the MG samples, with concentrations ranging from 16.3 to 576.7 mg g? 1. Benzocaine was found in only one MG sample, at a concentration of 84.8 mg g? 1. Fourteen elements were identified by ICP-OES, and a wide variation was observed in the concentrations of Ca, Mg, Na, P, Al, Fe, Mn and Zn. Pearson Product–moment Correlations between the analytes allowed the constituents to be associated with the chemicals used in the manufacturing of cocaine and with some common diluents. The study of the purity of cocaine and the presence and concentration of adulterants and inorganic constituents is important because the latter can have deleterious effects on health.  相似文献   

17.
《Science & justice》2022,62(4):411-417
Forensic anthropology in South Africa is well developed in the higher education sector, with advanced training and research programmes. Despite this and decades of academic involvement in casework, forensic anthropology still lacks a defined framework and mandate at a governmental level. Therefore, the involvement of forensic anthropologists’ expertise varies markedly between cases, provinces, and among various stakeholders within the country, to the detriment of dispensation of social and criminal justice. The lack of clearly defined guidelines for the rendering of the service was exemplified and demonstrated through a recent forensic case. Here, contextual information was absent, and the remains posed a challenge to analyse, ostensibly due to missing information. Numerous questions were raised during the analysis of the remains, and broader concerns about the investigative involvement of a forensic anthropologist within South African casework were brought to the fore. Through the analysis of this case, we describe the deductive processes that led to the formation of an opinion that the skeletal linear defects were the result of taphonomic changes. In addition, we highlight how these efforts where constrained and each step in the process unnecessarily hindered. Finally, we demonstrate the capacity and willingness of forensic anthropology practitioners to be involved, and how, without governmental support, it is a great potential lamentably untapped.  相似文献   

18.
PCR amplification of tetrameric short tandem repeats (STRs) can lead to Taq enzyme slippage and artefact products typically one repeat unit less in size than the parent STR. These back stutter or n ? 4 amplification products are low-level relative to the amplification of the parent STR but are widely seen in the forensic community where tetrameric STRs are employed in the generation of DNA profiles. To aid the interpretation of DNA mixtures where minor contributor(s) might be present in comparable amounts to the back stutter products, the typical amounts of back stutter generated have been well characterised and guidelines for interpretation are in place. However, further artefacts thought to be Taq enzyme slippage leading to products with one repeat unit greater than the parent sequence (n + 4 or forward stutter) or two repeats less (n ? 8 or double back stutter) also occur, but these have not been well characterised despite their potential influence in mixture interpretations. Here we present findings with respect to these additional artefacts from a study of 10,000 alleles and include guidelines for interpretation.  相似文献   

19.
Previous studies have documented gender-related differences in a number of aspects of the pharmacology of opiates, including their analgesic activity, stimulative properties and generation of physical dependence. The current experiments were carried out with the aim to examine whether male–female differences exist in the blood and brain levels of opiates attained after their intraperitoneal injection to male and female Wistar rats. The tests were performed 5, 15, 45 and 120 min after the animal treatment with seized heroin. Gas chromatography–mass spectrometry (GC–MS) method was developed to quantitatively determine opiate alkaloids in blood and brain regions (known for their high concentration of μ-opiate receptors): cortex, brainstem, amygdala and basal ganglia. Maximal contents of opiates in blood of animals of both genders were found in the second measurement time (15 min), the values measured in the males being significantly higher, which suggests a faster passage of the opiates from blood to brain tissue in female animals. The highest content of opiates in the brain tissue of female animals was measured 15 min and with male animals 45 min after the treatment, which also indicates faster distribution of opiates from blood to brain in the female compared to male rats. The highest proportion of opiates was found in the basal ganglia of the animals of both genders. The obtained results offer the possibility of selecting this part of the brain tissue of both males and females as a representative sample for identifying and assessing contents of opiates.  相似文献   

20.
This study investigated the ability of individuals with experience in gait analysis to identify people by observing features of gait recorded by closed circuit television cameras (CCTV). Seven experienced analysts each viewed five samples of footage. Each sample showed a “target walker” and five “suspect walkers.” The task of the experienced analysts was to determine which, if any, of the “suspect walkers” was the “target walker.” All of the participant “walkers” wore identical loose fitting clothing to mask anatomical and body contour features, and balaclavas to obscure facial features. The overall results showed that the experienced analysts made a correct decision in 124 of 175 cases (71%), significantly better than would have been expected to have occurred by chance (p < 0.05). A significant variation in correct decisions (p < 0.05) was shown to occur between the various angles from which the footage was recorded, footage recorded in the saggital plane showing the highest number of correct decisions. Significantly more correct decisions (p < 0.05) were also shown to occur when the footage of the “target walker” and that of the “suspect walker” were taken from the same angle. The results suggest that individuals with experience in gait analysis perform well in the comparative identification of suspects from CCTV footage, and therefore do have a role to play as expert witnesses in this field.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号