首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
The use of a direct analysis in real time (DART) mass spectrometer (MS) instrument was optimized for 22 compounds of organic explosive residues to provide a guide for DART‐MS users in rapid screening of explosive compounds. Samples were introduced as neat solutions and sequential dilutions to determine optimal instrument conditions and lowest concentration detectable. Most compounds were optimized to 250°C in the negative ion mode, and several compounds benefited from the addition of a chloride dopant from methylene chloride (amino‐dinitrotoluenes, RDX, EGDN, and PETN). Few compounds were more sensitive in the positive ion mode (TEGDN, DEGDN, HNS, and DMNB). Mixtures of compounds were detected using clean room wipes, directly from their surfaces and from subsequent extractions. Compounds from the mixtures were also successfully detected in soil and from swipes of spiked surfaces. The instrument showed merit in detection of pg/μL solutions for most of the compounds and among the substrates tested.  相似文献   

2.
Gamma-Hydroxybutyric acid (GHB) is a CNS depressant that has been abused recreationally for its purported euphoric and relaxation effects and for the purposes of drug facilitated sexual assault due to its sedative and amnesic effects at higher doses. The dramatic increase in the abuse of GHB and association in criminal investigations over the past decade has created the need for forensic laboratories to develop analytical methods to detect GHB in a variety of matrices. The method developed in this work used solid-phase microextraction (SPME) to extract GHB from aqueous samples followed by on-fiber derivatization and analysis by gas chromatography/mass spectrometry (GC/MS). This method detected GHB in aqueous matrices with good sensitivity, high precision, excellent linearity from 0.01 mg/mL to 0.25 mg/mL, and without the need for sample manipulation that could cause interconversion between GHB and its lactone, GBL. The method was successfully applied for detection of GHB in spiked water and beverage samples.  相似文献   

3.
化学显色法快速筛选饮料及尿液中γ-羟基丁酸和γ-丁内酯   总被引:1,自引:0,他引:1  
Zhang SY  Huang ZP 《法医学杂志》2006,22(6):424-427,F0004
目的建立化学显色法快速筛选饮料及尿液中γ-羟基丁酸(GHB)及其前体γ-丁内酯(GBL)的方法。方法在酸性条件下GHB转化为GBL,GBL和盐酸羟胺在碱性条件下生成γ-羟基丁酰羟胺,γ-羟基丁酰羟胺在酸性条件下和三氯化铁反应,生成紫红色的络合物。结果饮料中GHB最低检出浓度为0.5~2mg/mL,低于常见滥用质量浓度。该方法也可以用于尿液分析,最低检出质量浓度为0.5mg/mL。考察了常见有机溶剂和麻醉镇静药物的干扰。结论该方法简单、安全、快速,为临床和法庭科学实验室快速筛选GHB和GBL提供了便利。  相似文献   

4.
A novel approach for the analysis of inkjet inks is being reported. A time‐of‐flight mass spectrometer, coupled with a Direct Analysis in Real Time (DART?) ion source (AccuTOF? DART?), was used to determine if inkjet inks from various manufacturers and models of printers could be reliably differentiated, characterized, and identified. A total of 217 ink standards were analyzed. As inkjet printing often involves the use of multiple colors (e.g., cyan, magenta, yellow, and black) to form an image or text, two different approaches to creating a library of standards and sampling methods were evaluated for implementation in a standard operating procedure. This research will show that a microscopic examination of the region of interest is requisite to identify what colors were utilized during the printing process, prior to comparing with known standards. Finally, blind testing was administered with 10 unknown samples to assess the validity and accuracy of the methodology.  相似文献   

5.
A 1H nuclear magnetic resonance (1H NMR) method for the determination of gamma-hydroxybutyric acid (GHB) and gamma-hydroxybutyrolactone (GBL) in human serum and urine using spiked samples has been developed. The method gives linear responses (correlation coefficients of 0.99 or greater) over the concentration range 0.01 mg/mL to 4.0 mg/mL in urine and 0.3 mg/mL to 2.0 mg/mL in serum. No sample pretreatment is required. Studies of the chemical interconversion of GBL and GHB showed hydrolysis of GBL to be rapid at pH 11.54, slower and less complete (30% hydrolysis) at pH 2.54 and slowest at pH 7.0, reaching 30% hydrolysis in about 40 days. No esterification of GHB was observed at any pH.  相似文献   

6.
Two hundred and forty-seven serum samples which have been collected by police during roadside testing and have been found positive for amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA) and/or 3,4-methylenedioxyethamphetamine (MDE) were analyzed for gamma-hydroxybutyrate (GHB). Serum samples were spiked with deuterated GHB as internal standard and acetonitrile was added to achieve dilution and protein precipitation. Samples were analyzed with a LC-MS/MS system operated in the multiple reaction monitoring mode (MRM) using a TurboIonSpray source. Chromatographic separation was achieved using a Synergi Polar RP column applying a gradient elution with a runtime of 15 min. To differentiate between endogenous and exogenously administered GHB a cut-off concentration of 10 microg/mL was applied. Five samples exceeded this concentration and were found positive for GHB. These samples were only found positive for amphetamine but no other amphetamine derivatives were detected, while in three samples THC and in one sample cocaine, benzoylecgonine and ethanol were found.  相似文献   

7.
The intentional or unintentional adulteration of baby formula with drugs of abuse is one of the many increasingly complex samples forensic chemists may have to analyze. This sample type presents a challenge because of a complex matrix that can mask the detection of trace drug residues. To enable screening of baby formula for trace levels of drugs, the use of solid‐phase microextraction (SPME) coupled with direct analysis in real‐time mass spectrometry (DART‐MS) was investigated. A suite of five drugs was used as adulterants and spiked into baby formula. Samples were then extracted using SPME fibers which were analyzed by DART‐MS. Development of a proof‐of‐concept method was completed by investigating the effects of the DART gas stream temperature and the linear speed of the sample holder. Optimal values of 350°C and 0.2 mm/s were found. Once the method was established, representative responses and sensitivities for the five drugs were measured and found to be in the range of single ng/mL to hundreds ng/mL. Additional studies found that the presence of the baby formula matrix increased analyte signal (relative to methanolic solutions) by greater than 200%. Comparison of the SPME‐DART‐MS method to a traditional DART‐MS method for trace drug detection found at least a factor of 13 improvement in signal for the drugs investigated. This work demonstrates that SPME‐DART‐MS is a viable technique for the screening of complex matrices, such as baby formula, for trace drug residues and that development of a comprehensive method is warranted.  相似文献   

8.
Abstract:  The Direct Analysis in Real Time (DART) ion source is a relatively new mass spectrometry technique that is seeing widespread use in chemical analyses world-wide. DART studies include such diverse topics as analysis of flavors and fragrances, melamine in contaminated dog food, differentiation of writing inks, characterization of solid counterfeit drugs, and as a detector for planar chromatography. Validation of this new technique for the rapid screening of forensic evidence for drugs of abuse, utilizing the DART source coupled to an accurate mass time-of-flight mass spectrometer, was conducted. The study consisted of the determination of the lower limit of detection for the method, determination of selectivity and a comparison of this technique to established analytical protocols. Examples of DART spectra are included. The results of this study have allowed the Virginia Department of Forensic Science to incorporate this new technique into their analysis scheme for the screening of solid dosage forms of drugs of abuse.  相似文献   

9.
Recently, much attention has been given to benzodiazepines and gamma-hydroxybutyric acid (GHB) related compounds owing to their alleged widespread use as date-rape drugs. Toxicologists would greatly benefit from a screening method that allows for the simultaneous detection of both groups of substances. A new capillary electrophoresis (CE) method has been developed in the micellar mode to accomplish this separation in under 16 min using a sodium dodecyl sulfate (SDS)/sodium tetraborate/boric acid buffer with an acetonitrile organic modifier. Optimization of SDS and organic modifier concentration, along with pH, were performed on a set of standards containing eight benzodiazepines, GHB, gamma-butyrolactone, and the internal standard, sulfanilic acid. The method was shown to have a detection limit of less than 2 microg/ml for five out of eight benzodiazepines with a linear range of 2.5-100 microg/ml. The detection limit for GHB was 32 mg/ml with a linear range to 2500 microg/ml. This method was applied to the rapid analysis of spiked beverages. GHB spiked beverages were monitored after using a series of simple dilutions to determine the effects of time on the drug analysis. Possible interfering peaks from drugs of abuse and artifacts from a variety of different drink combinations were also studied in detail. A one-step liquid-liquid extraction was the only necessary sample pretreatment.  相似文献   

10.
The in vitro production of GHB was observed in freshly collected, untreated whole blood samples using glass BD-Vacutainers and polypropylene S-monovettes. GHB concentrations were determined daily over a period of one week and after 3, 6 and 9 weeks again. Furthermore, the GHB concentration in 40 untreated random whole blood samples stored at 4°C for a longer period of time (10 samples 12 month, 10 samples 24 month and 20 samples 36 month) was also determined. For comparison, the in vitro production of GHB in freshly collected and prepared serum samples was observed. GHB serum concentrations were determined three times over a period of one week and once again after six weeks. Sample preparation was performed by means of methanolic extraction following the precipitation of whole blood and serum samples. A methanolic standard calibration was done in a low range of 0.005-0.1 μg/mL (LOD: 0.004, LLOQ: 0.013). For quantification a spiked blood bank serum with a determined GHB concentration of 0.09 μg/mL was used. Corrected calibrations in the range of 0.09-5.09 μg/mL were used (LOD: 0.08 μg/mL, LLOQ: 0.30 μg/mL), recovery: 91.3% (high level: 4.09 μg/mL) 50.5% (low level: 0.19 μg/mL). RESULTS: Relevant elevation of GHB was observed in all whole blood samples stored in liquid form (4°C or room temperature). In two of the 40 whole blood samples stored over a longer period of time at 4°C, GHB concentrations in the range of 13 μg/mL were even determined. These findings constitute grounds for caution. Even a GHB cut-off level of 5 μg/mL cannot be considered as "absolutely positive" proof of a case of exogenous administration, at least in untreated liquid blood samples in long time storage. However, no significant elevations of GHB were otherwise observed in any of the serum samples independently of storage temperature nor in the whole blood samples that were frozen for storage. CONCLUSIONS: The results suggest that the cut-off for exogenous GHB of 5 μg/mL could be lowered significantly, with the consequence of winning valuable time for the potential victim, but only if serum is collected for GHB determination or if the whole blood sample is frozen immediately after collection and the procedure well documented.  相似文献   

11.
Direct analysis in real time mass spectrometry (DART‐MS) served as a method for rapid high‐throughput screening of six commercially available “Spice” products, detecting various combinations of five synthetic cannabinoids. Direct analysis in real time is an ambient ionization process that, along with high mass accuracy time‐of‐flight (TOF)‐MS to 0.0001 Da, was employed to establish the presence of cannabinoids. Mass spectra were acquired by simply suspending a small portion of sample between the ion source and the mass spectrometer inlet. The ability to test minute amounts of sample is a major advantage when very limited amounts of evidentiary material are available. In addition, reports are widespread regarding the testing backlogs that now exist because of the large influx of designer drugs. This method circumvents time‐consuming sample extraction, derivatization, chromatographic, and other sample preparative steps required for analysis by more conventional mass spectrometric methods. Accordingly, the synthetic cannabinoids AM‐2201, JWH‐122, JWH‐203, JWH‐210, and RCS‐4 were identified in commercially available herbal Spice products, singly and in tandem, at concentrations within the range of 4–141 mg/g of material. Direct analysis in real time mass spectrometry decreases the time necessary to triage analytical evidence, and therefore, it has the potential to contribute to backlog reduction and more timely criminal prosecution.  相似文献   

12.
目的使用实时直接分析-串联质谱,建立快速检测人血中的JWH-018、JWH-250和AM-2201的方法。方法用乙腈-甲醇(4:1)沉淀蛋白的方法对血样进行简单前处理,采用DART 12Dip-it自动进样系统,以正离子、MRM模式进行分析。结果血液中JWH-018、JWH-250、AM-2201可以得到有效检测,在0.02-5.00μg/m L线性关系良好,相关系数均大于0.99,检出限分别为0.016μg/m L,0.003μg/m L和0.017μg/m L,日内、日间RSD均小于15%。结论本文所建方法灵敏度高,准确性较好,方法省时省力,可用于实际案例血液中合成大麻素JWH-018、JWH-250、AM-2201的分析。  相似文献   

13.
A simple method of detection was developed for gamma-hydroxybutyrate (GHB). The method involves the derivatization of GHB using a hexyl-chloroformate procedure in aqueous media (such as water or urine), extraction of the derivatization product directly from the sample using solid-phase microextraction, and subsequent separation and detection with gas chromatography quadrupole ion trap mass spectrometry. The deuterated form of GHB (GHB-D6) is used as an internal standard for quantitation. The method was linear for GHB-spiked pure water samples from 2 to 150 microg/mL GHB with a detection limit of 0.2 microg/mL. Spiked urine samples showed linearity from 5 to 500 microg/mL GHB with a detection limit of 2 microg/mL. The SPME-GC/MS method is applied to actual case samples, and the results are compared to those values obtained using a conventional GC/MS method. Sensitivity and linearity are comparable to those seen using traditional methods of separation, yet the SPME method is superior due to the simplicity, speed of analysis, reduction in solvent waste, and ability to differentiate between GHB and gamma-butyrolactone (GBL).  相似文献   

14.
Abstract: Thin layer chromatography (TLC) is a technique that is commonly employed in the forensic drug analysis of pharmaceutical preparations. Detection is typically accomplished using various visualization spray reagents. Conventional gas chromatography–mass spectrometry (GC‐MS) analysis is typically performed to confirm the TLC results. Depending on the drugs tested and the instrument conditions required, this confirmation can take up to an hour to complete. Direct analysis in real time (DART?) is an ionization source, coupled to an accurate‐mass time‐of‐flight mass spectrometer that has the capability to ionize materials under ambient conditions. To streamline analysis, the combination of TLC with DART? detection is proposed to screen and subsequently identify drug compounds, all from the same TLC plate. DART? confirmations of TLC analyses take <10 min to complete and compare favorably to GC‐MS in sensitivity and selectivity. This study validates the use of TLC‐DART in the forensic identification of the components of several pharmaceutical preparations.  相似文献   

15.
Conventional Gas Chromatography‐Mass Spectrometry (GC‐MS) methods for the analysis of ignitable liquids (ILs) are usually time‐consuming, and the data produced are difficult to interpret. A fast IL screening method using direct analysis in real time mass spectrometry (DART‐MS) is proposed in this study. GC‐MS, QuickStrip DART‐MS, and thermal desorption DART‐MS methods were used to analyze neat ILs and thermal desorption DART‐MS without extraction was used to analyze ILs on five substrates (e.g., carpet, wood, cloth, sand, and paper). Compared to GC‐MS, DART‐MS methods generated different spectral profiles for neat ILs with more peaks in the higher mass range and also provided better detection of less volatile compounds. ILs on substrates were successfully classified (98 ± 1%) using partial least squares discriminant analysis (PLS‐DA) models based on thermal desorption DART‐MS data. This study shows that DART‐MS has great potential for the high‐throughput screening of ILs on substrates.  相似文献   

16.
Blood, brain, and hair GHB concentrations following fatal ingestion   总被引:1,自引:0,他引:1  
Despite the increasing incidence of illicit use of gamma-hydroxybutyrate (GHB), little information is available documenting levels of the drug in GHB fatalities. We measured GHB levels in postmortem blood, brain and hair specimens from a suspected overdose case by gas chromatography/mass spectrometry (GC/MS) following solid phase extraction (SPE) and derivatization with bis(trimethyl-silyl) trifluoroacetamide (BSTFA). Examination found 330 microg/mL GHB in femoral blood and 221 ng/mg GHB in frontal cortex brain tissue, values higher than those typically reported in the literature. The hair shaft was negative for GHB whereas the plucked root bulbs with outer root sheath attached (2,221 ng/mg) and root bulbs after washing and removal of the outer root sheath (47 ng/mg) contained the drug. Our results are consistent with an acute single dose of GHB and, as the toxicology screen was negative for other drugs of abuse, emphasize the significant danger of this drug.  相似文献   

17.
The endogenous nature of the drug of abuse gamma hydroxybutyric acid (GHB) has caused various interpretative problems for toxicologists. In order to obtain data for the presence of endogenous GHB in humans and to investigate any factors that may affect this, a volunteer study was undertaken. The GHB concentrations in 119 urine specimens from GHB-free subjects and 25 urine specimens submitted for toxicological analysis showed maximal urinary GHB concentrations of 3mg/l. Analysis of 15 plasma specimens submitted for toxicological analysis detected no measurable GHB (less than 2.5mg/l). Studies in a male and female volunteer in which different dietary food groups were ingested at weekly intervals, showed significant creatinine-independent intra-individual fluctuation with overall urine GHB concentrations between 0 and 2.55, and 0 and 2.74mg/l, respectively. Urinary concentrations did not appear to be affected by the particular dietary groups studied.The concentrations measured by gas chromatography with flame ionisation detection (GC-FID) and gas chromatography with mass spectrometry (GC-MS) lend further support to the proposed urinary and plasma interpretative cut-offs of 10 and 4mg/l, respectively, where below this it is not possible to determine whether any GHB detected is endogenous or exogenous in nature.  相似文献   

18.
The use of amphetamine and 'ecstasy' (MDMA) has increased exponentially in many European countries since the late nineties, leading to a rapid growth in the number of clinical and forensic analyses. Therefore, a rapid screening procedure for these substances in biological specimens has become an important part of routine toxicological analysis in forensic laboratories. The objective of this study was to evaluate the Cozart amphetamine enzyme-linked immunosorbent assay (ELISA) for the screening of plasma samples and oral fluid samples (collected with the Intercept device). Authentic plasma samples from drivers (n=360) were screened, using an 1:5-fold dilution. True positive, true negative, false positive and false negative results were determined relative to the in-house routine GC-MS analysis. Samples consisted of 144 amphetamine-only positives, 141MDMA/MDA-only positives, and 74 negatives when using the limit of quantitation as the cut-off level for confirmation (10 ng/mL). Using these results, receiver operating characteristic (ROC) curves were generated and optimal cut-off values for the screening assay were calculated. Analysis showed that the ELISA is able to predict the presence of either amphetamine or *MDMA/MDA (*MDMA as its metabolite MDA) in plasma samples with 98.3% sensitivity and 100% specificity at a cut-off value of 66.5 ng/mL d-amphetamine equivalents. A similar analysis was conducted on 216 oral fluid specimens collected from a controlled double blind study. Subjects received placebo or a high (100 mg) or low (75 mg) dose of MDMA. Oral fluid samples were collected at 1.5 and 5.5h after administration. Combined results of the analysis of the high and low dose oral fluid samples indicated a screening cut-off of 51 ng/mL d-amphetamine equivalents with both a sensitivity and specificity of 98.6% (using a LC-MS/MS confirmation cut-off of 10 ng/mL). In conclusion, these data indicate that the Cozart AMP EIA plates constitute a fast and accurate screening technique for the identification of amphetamine and MDMA/MDA positive plasma samples and oral fluid specimens (collected with Intercept. It should be emphasized that method validation should be performed for each type of biological matrix.  相似文献   

19.
A solid-phase enzyme immunoassay involving microtiter plates was recently proposed by International Diagnostic Systems corporation (IDS) to screen for buprenorphine in human serum. The performance of the kit led us to investigate its applicability in other biological matrices such as urine or blood, and also hair specimens. Low concentrations of buprenorphine were detected with the ELISA test and confirmed by HPLC/MS (buprenorphine concentrations measured by HPLC/MS: 0.3 ng/mL in urine, 0.2 ng/mL in blood, and 40 pg/mg in hair). The intra-assay precision values were 8.7% at 1 ng/mL of urine (n = 8), 11.5% at 2 ng/mL in serum (n = 8), and 11.5% at 250 pg/mg of hair (n = 8), respectively. The immunoassay had no cross-reactivity with dihydrocodeine, ethylmorphine, 6-monoacetylmorphine, pholcodine, propoxyphene, dextromoramide, dextrometorphan at 1 and 10 mg/L, or codeine, morphine, methadone, and its metabolite EDDP. A 1% cross-reactivity was measured for a norbuprenorphine concentration of 50 ng/mL. Finally, the immunoassay was validated by comparing authentic specimens results with those of a validated HPLC/MS method. From the 136 urine samples tested, 93 were positive (68.4%) after the ELISA screening test (cutoff: 0.5 ng/mL) and confirmed by HPLC/MS (buprenorphine concentrations: 0.3-2036 ng/mL). From the 108 blood or serum samples screened, 27 were positive (25%) after the ELISA test with a cutoff value of 0.5 ng/mL (buprenorphine concentrations: 0.2-13.3 ng/mL). Eighteen hair specimens were positive (72%) after the screening (cutoff: 10 pg/mg) and confirmed by LC/MS (buprenorphine concentrations: 40-360 pg/mg). The ELISA method produced false positive results in less than 21% of the cases, but no false negative results were observed with the immunological test. Four potential adulterants (hypochloride 50 mL/L, sodium nitrite 50 g/L, liquid soap 50 mL/L, and sodium chloride 50 g/L) that were added to 10 positive urine specimens (buprenorphine concentrations in the range 5.3-15.6 ng/mL), did not cause a false negative response by the immunoassay.  相似文献   

20.
The first case involving an alleged sexual assault linked to the use of gamma-hydroxybutyric acid (GHB) in Oklahoma is reported. A-48-year-old Caucasian woman taking amitriptyline was known to have voluntarily ingested a sports drink containing a relaxing health product. She purportedly experienced unconsciousness that persisted for approximately 4 h. The toxicological testing on urine identified GHB, amitriptyline, and nortriptyline using a capillary Hewlett-Packard 6890 gas chromatograph coupled to a Hewlett-Packard 5973 mass selective detector (MSD). The GHB concentration in urine was 26.9 microg/mL. Urine concentrations of amitriptyline and nortriptyline were not determined. The analytical method used for identifying and quantitating GHB can be applied to matters of forensic interests.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号